Cisco Network Tasks

This chapter contains the following sections:

Activate SAN Zone Set

Summary
Activate a SAN zone set for a Nexus device.
Description
This task activates or de-activate a SAN zone set on a Nexus device. If the Activate option is enabled, then a rollback deactivates and removes the zone set from the ACTIVE list. Once the zone set is removed from the ACTIVE list, the device restarts the zone merge process. If the Disable Rollback option is selected, rollback is not permitted.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
SAN Zone Set Select one or more SAN Zone set network​SANZone​Set​Identity Y
Activate Check this option to activate a zone set.​ By default, this field is checked.​ Performing rollback reactivates the zone set
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​SET_​IDENTITY Identity for San Zone Set.​ network​SANZone​Set​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Add IP ACL Rule

Summary
Add an IP rule to an ACL.
Description
This task adds an IP rule to an access control list (ACL) on the device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
ACL Name Choose an ACL name gen_​text_​input Y
Action Choose a permit or deny action for the rule gen_​text_​input
Protocol Choose a protocol for the rule.​ Valid values are tcp, udp, ip and ipv6.​ gen_​text_​input
Source Type Choose a source type.​ Valid values are any, network prefix, network address and host.​ gen_​text_​input
Source Network Prefix Enter a source network prefix for IPv4 in the format A.​B.​C.​D/LEN or IPv6 in the format X:X:X:X:X:X:X:X/LEN.​ For example: 10.​23.​2.​4/8 or ab:23:45:fg:kj:ty:99:78/15 gen_​text_​input Y
Source Network Address Enter a source network address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Source Wildcard Bits Enter source wildcard bits in the format A.​B.​C.​D.​ Not applicable to IPv6.​ For example: 10.​20.​2.​3.​ gen_​text_​input Y
Source Host Address Enter a source host addres for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Destination Type Choose a destination type.​ Valid values are any, network prefix, network address and host.​ The default is any.​ gen_​text_​input
Destination Network Prefix Enter a destination network prefix for IPv4 in the format A.​B.​C.​D/LEN or IPv6 in the format X:X:X:X:X:X:X:X/LEN.​ For example: 10.​23.​2.​4/8 or ab:23:45:fg:kj:ty:99:78/15.​ gen_​text_​input Y
Destination Network Address Enter a destination network address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Destination Wildcard Bits Enter the destination wildcards in the format A.​B.​C.​D.​ Not applicable to IPv6.​ For example: 10.​20.​2.​3.​ gen_​text_​input Y
Destination Host Address Enter a destination host address for IPv4 n the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​IP_​ACL_​NAME_​IDENTITY ACL name ip on which selected operation performed.​ networking_​nxos_​ip_​acl_​info

Add MAC ACL Rule

Summary
Add a MAC rule to an ACL.
Description
This task adds a media access control (MAC) rule to an access control list (ACL) on the device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
ACL Name Choose an ACL name gen_​text_​input Y
Action Choose a permit or deny action for the rule.​ The default value is permit.​ gen_​text_​input
Source Type Chooose a source type.​ Valid values are any or source MAC address.​ The default value is any.​ gen_​text_​input
Source MAC address Enter a source MAC address.​ For example: E.​E.​E or EE-EE-EE-EE-EE-EE or EE:EE:EE:EE:EE:EE or EEEE.​EEEE.​EEEE.​ gen_​text_​input Y
Source wildcard bits Enter source wildcard bits.​ For example: E.​E.​E or EE-EE-EE-EE-EE-EE or EE:EE:EE:EE:EE:EE or EEEE.​EEEE.​EEEE.​ gen_​text_​input Y
Destination Type Choose the destination type.​ Valid values are any or destination MAC address.​ The default value is any.​ gen_​text_​input
Destination MAC address Enter a destination MAC address.​ For example: E.​E.​E or EE-EE-EE-EE-EE-EE or EE:EE:EE:EE:EE:EE or EEEE.​EEEE.​EEEE.​ gen_​text_​input Y
Destination wildcard bits Enter destination wildcard bits.​ For example: E.​E.​E or EE-EE-EE-EE-EE-EE or EE:EE:EE:EE:EE:EE or EEEE.​EEEE.​EEEE.​ gen_​text_​input Y
VLAN ID Choose a VLAN ID vlan​ID
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​MAC_​ACL_​NAME_​IDENTITY ACL name mac on which selected operation performed.​ networking_​nxos_​mac_​acl_​info

Add Member To SAN Zone

Summary
Add a member to a zones on a Nexus device.
Description
This task adds a member to the SAN zone on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
SAN Zone Select a SAN Zone network​SANZone​Identity Y
Type Choose any of the listed types: p​WWN, FCALIAS, devicealias.​ If this field is left blank, the value defaults to p​WWN.​ gen_​text_​input
Member Enter the value for the member in this format: hh:hh:hh:hh:hh:hh:hh:hh.​ For example: 11:11:11:11:11:11:11:11.​ gen_​text_​input Y
Prefer Smart​Zoning Zone Check this option if the device supports smartzoning to enable it in the VSAN.​ By default this field is unchecked
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​SANZONE_​MEMBER San Zone Member Configured.​ gen_​text_​input
OUTPUT_​SANZONE_​TYPE San Zone Type Configured.​ gen_​text_​input
OUTPUT_​SMARTZONE_​TYPE Smart Zone Type Configured.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​SAN_​FC_​ALIAS FC alias on which selected operation performed.​ FCAlias​Identity
OUTPUT_​SAN_​DEV_​ALIAS Device alias on which selected operation performed.​ networking_​san_​device_​alias_​identity

Add Physical Network Account

Summary
Add a physical network account.
Description
This task adds a physical network account.
Inputs
Input Description Mappable To Type Mandatory
Pod Name gen_​text_​input Y
Device Category Enter any of the listed device categories: Cisco ASA or Cisco Nexus OS.​ If this field is left blank, the value defaults to Cisco ASA gen_​text_​input
Device IP gen_​text_​input Y
Protocol gen_​text_​input Y
Port gen_​text_​input Y
Username gen_​text_​input Y
Password gen_​text_​input Y
Enable Password Provide an enable password for the network device
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
DEVICE_​INVENTORY_​STATUS Device Inventory Status gen_​text_​input

Add SAN Zone to Zone Set

Summary
Add a SAN zone to a zone set on a Nexus device.
Description
This task adds a zone to a SAN zone set on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
SAN Zone Set Select a SAN Zone set network​SANZone​Set​Identity Y
SAN Zone Select one or more SAN Zone network​SANZone​Identity Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Reactivate Zoneset during Rollback Check this option to reactivate zoneset during rollback.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​SET_​IDENTITY Identity for San Zone Set.​ network​SANZone​Set​Identity
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Add or Update Username and Password

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
User Name Provide a user name gen_​text_​input Y
Password Provide a password password Y
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​USERNAME Password Reset User Name password_​reset_​username

Allocate Port To VDC

Summary
Allocate a physical port to a VDC.
Description
This task allocates a physical port to a virtual data channel (VDC) on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VDC Name Select a VDC name nxos​VDCIdentity Y
Select Port Enter one or more ports to be allocated, separated with commas.​ For example: ethernet1/4, ethernet1/5.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Assign FC Port to VSAN

Summary
Assign an FC port to a VSAN.
Description
This task makes an FC (Fiber Channel) port a member of a virtual storage area network (VSAN) on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select FC Port Choose a FC port for VSAN assignment.​ For example: vfc1 or vfc2.​ gen_​text_​input Y
Select FC Port Select a FC port for VSAN assignment.​ fc_​port_​name
VSAN ID Choose the VSAN ID.​ Valid range is 2 to 4094.​ vsan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Assign Port to Port Channel

Summary
Assign an ethernet port to a port channel.
Description
This task adds an ethernet port to a port channel on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select Port Select a port to assign to a port channel.​ For example: Ethernet1/1.​ gen_​text_​input Y
Select Port Channel Name Select a port channel to assign port.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Assign Static MACAddress

Summary
Assign a static MAC address for a layer 3 interface on a Nexus device.
Description
This task assigns a static MAC address entry for a layer 3 interface on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Select a port networking_​device_​interface Y
MAC Address Select a MAC address networking_​device_​mac Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface
OUTPUT_​NETWORKING_​DEVICE_​MACADDRESS Network device MAC Address on which selected operation performed.​ networking_​device_​mac
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Assign VLAN to Group

Summary
Assign a VLAN to a UCS Director group.
Description
This task assigns a VLAN on a device to a UCS Director group.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VLAN ID Choose the VLAN ID.​ The valid range is between 1 and 3967 or 4048 and 4093.​ vlan​ID Y
Assign To Users Check this option to allow resource assignment to users.​ By default, this field is unchecked.​
User Group ID Choose the group to assign to VLAN user​Group Y
Comments Enter comments gen_​text_​input
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID

Assign VXLAN to PortProfile

Summary
Assign a VXLAN port profile to a Nexus device.
Description
This task assigns a VXLAN on the Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Select the domain name for the VXLAN bridge.​ gen_​text_​input Y
Select Port Profile Choose the port profile name.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name

Associate Private VLAN

Summary
Associate a private VLAN on a device.
Description
This task associates the primary and secondary VLAN on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Primary VLAN ID Choose the primary VLAN vlan​ID Y
Action Choose an action to perform on PVLAN: add or remove.​ Default is add.​ Y
Secondary VLAN ID Check one or more secondary VLANs vlan​ID Y
Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​ Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PRIMARY_​VLAN_​ID Primary VLAN ID on which the selected operation was performed vlan​ID
SECONDARY_​VLAN_​ID Secondary VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Associate VFC Interface

Summary
Associate a VFC on a Nexus device to a VSAN.
Description
This task associates a virtual fiber channel (VFC) to a VSAN on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VFC Id Choose the VFC ID gen_​text_​input Y
VSAN Id Enter the VSAN ID in this format: datacenter@device_​ip@vsan_​id.​ For example: Default​Pod@172.​29.​195.​162@10.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Associate VSAN to VLAN

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Vlan Select a VLAN ID vlan​ID Y
VSAN Id Enter the VSAN ID in this format: datacenter@device_​ip@vsan_​id.​ For example: Default​Pod@172.​29.​195.​162@10.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​DEVICE_​VLAN_​IDENTITY Identity for device vlan Infra​Network​VLANIdentity
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Clear SAN Zone Lock

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VSAN Id Select VSAN ID to clear zone lock vsan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure Access

Summary
Configure access on an ethernet or port channel interface.
Description
This task configures access on an ethernet or port channel interface on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select Port Select a port.​ networking_​device_​interface Y
Access VLAN Select an Access VLAN.​ vlan​ID Y
STP Port Type Choose a port type for spanning tree protocol use.​ Port types are edge, network and normal.​ The default is edge.​ gen_​text_​input
Description Enter an additional description to the configure access.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
ACCESS_​VLAN_​ID Access VLAN ID on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface

Configure Feature

Summary
Configure a feature on a Nexus MDS device.
Description
This task configures a feature on a Cisco Multilayer Director (MDS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Feature Check or uncheck this option to enable or disable the feature.​ By default, this field is unchecked.​ Y
Feature Name Select the name of the feature to configure networking_​device_​feature Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure Host Name

Summary
Configure a host name on a Nexus device.
Description
This task configures a host name on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Host Name Enter a Host Name.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
HOST_​NAME Host Name on which the selected operation was performed networking_​device_​host_​name
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure MACAddress Table

Summary
Configure MAC address table parameters.
Description
This task configures the MAC address table parameters, including aging time and learning mode.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Age Time Enter the agent time for the Mac address table in seconds.​ Enter 0 to disable.​ The range is from 120 to 918000 in increments of 5.​ For example: 255.​ gen_​text_​input Y
VLAN ID Select a VLAN ID Infra​Network​VLANIdentity
VLAN Learn mode.​ Choose the learning mode for the vlans gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure MST

Summary
Configure the MST mode of the spanning tree protocol for a Nexus device.
Description
This task configures multiple spanning tree (MST) mode for the spanning tree protocol on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Enable MST Check this option to enable or disable spanning tree MST mode.​ By default, this field is unchecked.​ Y
Name Specify the MST name to configure gen_​text_​input Y
Revision Enter the revision of the MST as an integer between 0 and 65535.​ gen_​text_​input Y
Hello Time Enter the hello time for the MST protocol.​ The valid range is 1 to 10.​ The hello time is the wait time in seconds between broadcast of configuration BPDUs.​ gen_​text_​input
Forward Time Enter the forward time for the MST between 4 and 30.​ The forward time is the forward delay timer period, in seconds.​ gen_​text_​input
Max Hop Count Enter the maximum hop count for the MST between 1 and 255 gen_​text_​input
Max Age in seconds Enter the maximum age for the MST between 6 and 40 gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure MST INSTANCE

Summary
Configure the MST Instance for the STP on a Nexus device.
Description
This task configures multiple spanning tree (MST) mode on an interface for the spanning tree protocol configuration on a PORT.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
MST Instance Provide an MST instance ID to be configured.​ The valid range is 1 to 4094.​ gen_​text_​input Y
VLAN Provide a VLAN ID or range.​ Valid values are between 1 and 4094.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure PVST

Summary
Configure the PVST mode of the spanning tree protocol for a Nexus device.
Description
This task configures per VLAN spanning tree (PVST) mode for the spanning tree protocol.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Enable PVST Check this option to enable or disable the spanning tree PVST mode.​ By default, this field is unchecked.​ Y
VLAN Provide a VLAN ID or range.​ Valid values are between 1 and 4094.​ gen_​text_​input
PVST Root Mode Check this option to enable or disable the spanning tree PVST in root mode.​ By default, this field is unchecked.​ Y
PVST Root Mode Primary Check this option to enable or disable the spanning tree PVST in root mode as primary.​ By default, this field is unchecked.​ Y
Diameter Enter the maximum number of bridges between any two end nodes.​ Valid range is 2 to 7.​ gen_​text_​input
Hello Time Enter the wait time in seconds between successive BPDU transmissions.​ Valid range is 1 to 10.​ gen_​text_​input
Priority Choose Priority for the PVST protocol gen_​text_​input
Path​Cost.​ Choose Path Cost for the PVST gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure Port

Summary
Configure a Port on a Nexus device.
Description
This task configures a port on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Choose a port.​ gen_​text_​input Y
Description Provide the port description gen_​text_​input
Enable Check or uncheck this option to enable or disable the port.​ By default, this field is checked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface

Configure Port License

Summary
Configure a port license for an MDS device.
Description
This task configures a port license for a Nexus multilayer director (MDS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Choose a port.​ gen_​text_​input Y
Acquire Check this option to acquire the license.​ By default, this field is checked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Configure Private VLAN Port

Summary
Configure a port with private VLANs.
Description
This task configures a port with a primary and secondary private VLAN.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select Port Choose the port to configure private VLAN.​ For example: Ethernet1/23.​ gen_​text_​input Y
Type Choose a private VLAN port type Y
Primary VLAN ID Choose the primary VLAN vlan​ID Y
Action Choose an action to perform on PVLAN: add or remove.​ By default add is selected.​ Y
Secondary VLAN ID Check one or more secondary VLAN vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure Private VLAN Port Profile

Summary
Configure a port profile with private VLANs.
Description
This task modifies a port profile with private primary and secondary VLANs configured on it.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Port Profile Name Enter the port profile name gen_​text_​input Y
Port Profile Type Choose a port profile type: Ethernet or Vethernet.​ By default Vethernet is selected.​ Y
Trunk Check this to create port profile in trunk mode.​ By default this field is unchecked.​
Private VLAN Type Choose a private VLAN port type Y
Primary VLAN ID Choose the primary VLAN vlan​ID Y
Action Choose an action to perform on PVLAN: add or remove.​ By default add is selected.​
Secondary VLAN ID Check one or more secondary VLAN vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure QOS on Nexus 1K

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Integrate with UCS QOS Policy Check this option to Integrate With UCS QOS system class policy.​ By default, this field is unchecked.​
UCS Account Name Select UCS account name ucs​Account​Name Y
Configure Platinum Class Check this option to configure platinum class parameters.​ By default, this field is unchecked.​
Platinum Class ACL Name Enter the ACLs for classifying platinum class traffic gen_​text_​input Y
Platinum Class COS Enter the platinum class COS level between 0 and 7 gen_​text_​input
Configure Gold Class Check this option to configure gold class parameters.​ By default, this field is unchecked.​
Gold Class ACL Name Enter the ACLs for classifying gold class traffic gen_​text_​input Y
Gold Class COS Enter the gold class COS level between 0 and 7 gen_​text_​input
Configure Silver Class Check this option to configure silver class parameters.​ By default, this field is unchecked.​
Silver Class ACL Name Enter the ACLs for classifying silver class traffic gen_​text_​input Y
Silver Class COS Enter the silver class COS level between 0 and 7 gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Request Approval Check this option to request approval to deliver commands to the device.​ By default, this field is unchecked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Configure QOS on Nexus 5K

Summary
Configure QOS policies on a Nexus 5k switch.
Description
This task configures quality of service (QOS) policies on a Nexus 5000 series switch.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Integrate with UCS QOS Policy Check this option to integrate with UCS QOS system class policy.​ By default, this field is unchecked.​
UCS Account Name Select UCS account name ucs​Account​Name Y
Configure Platinum Class Check this option to configure platinum class parameters.​ By default, this field is unchecked.​
Platinum Class ACL Name Choose an ACL name for classifying platinum class traffic gen_​text_​input Y
Platinum Class QOS Group Choose a QOS group.​ QOS group must be between 1 and 5.​ The default value is 1.​ gen_​text_​input
Platinum Class COS Choose a COS level.​ COS level must be between 1 and 7.​ The default value is 1.​ gen_​text_​input
Platinum Class MTU Enter an MTU value.​ MTU must be between 1500 and 9216.​ The default value is 1500.​ vlan​ID Y
Configure Gold Class Check this option to configure gold class parameters.​ By default, this field is unchecked.​
Gold Class ACL Name Choose an ACL name for classifying gold class traffic gen_​text_​input Y
Gold Class QOS Group Choose a QOS group.​ QOS group must be between 1 and 5.​ The default value is 1.​ gen_​text_​input
Gold Class BW Percentage Choose a bandwidth percentage.​ Bandwidth percentage must be between 1 and 100.​ The default value is 1.​ gen_​text_​input Y
Gold Class COS Choose a COS level.​ COS level must be between 1 and 7.​ The default value is 1.​ gen_​text_​input
Gold Class MTU Enter an MTU value.​ MTU must be between 1500 and 9216.​ The default value is 1500.​ vlan​ID Y
Configure Silver Class Check this option to configure silver class parameters.​ By default, this field is unchecked.​
Silver Class ACL Name Choose an ACL name for classifying silver class traffic gen_​text_​input Y
Silver Class QOS Group Choose a QOS group.​ QOS group must be between 1 and 5.​ The default value is 1.​ gen_​text_​input
Silver Class BW Percentage Choose a bandwidth percentage.​ Bandwidth percentage must be between 1 and 100.​ The default value is 1.​ gen_​text_​input Y
Silver Class COS Choose a COS level.​ COS level must be between 1 and 7.​ The default value is 1.​ gen_​text_​input
Silver Class MTU Enter an MTU value.​ MTU must be between 1500 and 9216.​ The default value is 1500.​ vlan​ID Y
Configure FC Class Check this option to configure FC class parameters.​ By default, this field is unchecked.​
FC Class BW Percentage Choose a bandwidth percentage.​ Bandwidth percentage must be between 1 and 100.​ The default value is 1.​ gen_​text_​input Y
Configure Default Class Check this option to configure default class parameters.​ By default, this field is unchecked.​
Defualt Class BW Percentage Choose a bandwidth percentage.​ Bandwidth percentage must be between 1 and 100.​ The default value is 1.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Request Approval Check this option to request approval to deliver commands to the device.​ By default, this field is unchecked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Configure QOS on Nexus 9K

Summary
Configure QOS policies on a Nexus 9K switch.
Description
This task configures quality of service (QOS) policies on a Nexus 9000 series switch.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Integrate with UCS QOS Policy Check this option to integrate with the UCS QOS system class policy.​ By default, this field is unchecked.​
UCS Account Name Select the UCS account name ucs​Account​Name Y
Configure Platinum Class Check this option to configure platinum class parameters.​ By default, this field is unchecked.​
Platinum Class ACL Name Enter ACLs for classifying platinum class traffic gen_​text_​input Y
Platinum Class QOS Group Enter the platinum class QOS group between 0 and 7 gen_​text_​input
Platinum Class COS Enter the platinum class COS level between 0 and 7 gen_​text_​input
Platinum Class MTU Enter the MTU value.​ Valid MTU range is 576 to 9216.​ MTU less than 1500 for COS 5-7 can bring down FEX port-channels.​ vlan​ID Y
Configure Gold Class Check this option to configure gold class parameters.​ By default, this field is unchecked.​
Gold Class ACL Name Enter the ACLs for classifying gold class traffic gen_​text_​input Y
Gold Class QOS Group Enter the gold class QOS group between 0 and 7 gen_​text_​input
Gold Class BW Percentage Enter the gold class bandwidth percentage within the range 1 to 100 gen_​text_​input Y
Gold Class COS Enter the gold class COS level between 0 and 7 gen_​text_​input
Gold Class MTU Enter an MTU value.​ Valid MTU range is 576 to 9216.​ MTU less than 1500 for COS 5-7 can bring down FEX port-channels.​ vlan​ID Y
Configure Silver Class Check this option to configure silver class parameters.​ By default, this field is unchecked.​
Silver Class ACL Name Select ACLs for classifying silver class traffic gen_​text_​input Y
Silver Class QOS Group Enter the silver class QOS group between 0 and 7 gen_​text_​input
Silver Class BW Percentage Enter the silver class bandwidth percentage within the range 1 to 100 gen_​text_​input Y
Silver Class COS Enter the silver class COS level between 0 and 7 gen_​text_​input
Silver Class MTU Enter an MTU value.​ Valid MTU range is 576 to 9216.​ MTU less than 1500 for COS 5-7 can bring down FEX port-channels.​ vlan​ID Y
Configure Default Class Check this option to configure default class parameters.​ By default, this field is unchecked.​
Default Class BW Percentage Select default class bandwidth percentage within the range 1 to 100 gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Request Approval Check this option to request approval to deliver commands to the device.​ By default, this field is unchecked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Configure Retention Setting

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Retention Period Value Enter a retention period value.​ This is the maximum age of the data that you want to retain.​ This value is combined with the retention period unit.​ For example if the retention period unit is Month(s), enter 3 if you want to retain data for a maximum of 3 months.​ gen_​text_​input
Retention Period Unit Choose a retention period unit.​ This is the unit of time for data retention.​ This value is combined with the retention period value.​ For example, if the retention period value is 3, choose Month(s) if you want to retain data for a maximum of 3 months.​ gen_​text_​input
Outputs
Output Description Type
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​PURGE_​SETTING_​DURATION Purge setting duration gen_​text_​input
OUTPUT_​PURGE_​SETTING_​FREQUENCY Purge setting duration gen_​text_​input

Configure SAN Zoning

Summary
Configure SAN zones and associate zones with zonesets.
Description
This task configures zones with UCS vHBA and NetApp Fiber Channel adapters as members and then associate the zones with the active zoneset. If there is no active zoneset available on the switch, the task creates a new zoneset and actives it.
Inputs
Input Description Mappable To Type Mandatory
Activate Zone Set Check this option to activate the zone set after creation.​ By default, this field is checked.​
Commit Zone Check this option to commit the SAN zone after creation.​ By default, this field is unchecked.​
Server Account Type Choose the server type, UCS or CIMC.​ The default is UCS.​ gen_​text_​input
Service Profile Select a service profile.​ ucs​Service​Profile​Identity Y
CIMC Server Select a CIMC server.​ cimc​Server​Identity Y
Select v​HBA Choose a v​HBA for fabric-A configuration.​ For example: fabric_​A [10:20:ab:d3:78:h6:8k:99].​ gen_​text_​input Y
Device Alias Fab A v​HBA Enter a device alias name for the v​HBA.​ If the selected v​HBA and WWPN exist on the device, then the device alias is not created.​ gen_​text_​input
VLAN ID Enter the VLAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ vlan​ID
VSAN ID Provide a VSAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ gen_​text_​input
Zone Name Enter a zone A name.​ gen_​text_​input
Net​App Account Name (Primary) Choose a primary Net​App account for fabric A configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Primary) Choose a primary Net​App fiber channel adapter for fabric A configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ gen_​text_​input Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapters are available.​ gen_​text_​input
Configure Secondary Head Check this option to configure a secondary head.​ Default value is unchecked.​
Net​App Account Name (Secondary) Choose a secondary Net​App account for fabric A configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Secondary) Choose a primary Net​App fiber channel adapter for fabric A configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ gen_​text_​input Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapter is available.​ gen_​text_​input
Select Device Select device for Fabric A configuration gen_​text_​input Y
Select Source Port Choose a source port to which the server is connected.​ For example: ethernet1/1 or gigabitethernet2/4.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN to map the VLAN.​ Valid range is 2 to 4094.​ gen_​text_​input Y
Configure Fabric B Check this option to configure zones for fabric B.​ By default, this field is unchecked.​
Select v​HBA Choose a v​HBA for fabric B configuration.​ gen_​text_​input Y
Device Alias Fab B v​HBA Provide a device alias name for the fabric B v​HBA.​ If the provided v​HBA and WWPN exist in the device, the device alias is not created.​ gen_​text_​input
VLAN ID Provide the VLAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ vlan​ID
VSAN ID Provide the VSAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ gen_​text_​input
Zone Name Enter the zone B name.​ gen_​text_​input
Net​App Account Name (Primary) Choose a primary Net​App account for fabric B configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Primary) Choose a primary Net​App fiber channel adapter for fabric B configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ Cluster​Filer​Identity Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapter is available.​ gen_​text_​input
Configure Secondary Head Check this option to configure a secondary head.​ Default value is unchecked.​
Net​App Account Name (Secondary) Choose a secondary Net​App account for fabric B configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Secondary) Choose a secondary Net​App fiber channel adapter for fabric B configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ Cluster​Filer​Identity Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as a prefix if multiple FC adapters are available.​ gen_​text_​input
Select Device Select a networking device for fabric B configuration in the formate datacenter@device_​ip.​ For example: test​Pod@10.​23.​210.​20.​ gen_​text_​input Y
Select Source Port Choose a source port to which the server is connected.​ For example: ethernet1/1 or gigabitethernet2/4.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN to map the VLAN.​ Valid range is 2 to 4094.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
FABRIC_​A_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric A gen_​text_​input
FABRIC_​A_​ZONE_​NAME Name of the zone that was created for fabric A gen_​text_​input
FABRIC_​A_​DEVICE_​IP Switch IP Address (Fabric A) networking_​device
FABRIC_​A_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
SAN_​ZONE_​A_​IDENTITY Identity for SAN Zone A gen_​text_​input
FABRIC_​A_​VDC_​NAME VDC Name (Fabric A) nxos​VDCIdentity
FABRIC_​B_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric B gen_​text_​input
FABRIC_​B_​ZONE_​NAME Name of the zone that was created for fabric B gen_​text_​input
FABRIC_​B_​DEVICE_​IP Switch IP Address (Fabric B) networking_​device
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
FABRIC_​B_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
SAN_​ZONE_​B_​IDENTITY Identity for SAN Zone B gen_​text_​input
FABRIC_​B_​VDC_​NAME VDC Name (Fabric B) nxos​VDCIdentity

Configure STP PORT

Summary
Configure PVST on an interface for the STP on a Nexus device.
Description
This task configures per VLAN spanning tree (PVST) on an interface for the spanning tree protocol configuration on a PORT.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Select a port networking_​device_​interface Y
VLAN Provide a VLAN ID or range.​ Valid values are between 1 and 4094.​ gen_​text_​input
Cost Auto Check this option to provide auto cost for the STP port.​ By default, this field is unchecked.​
Cost Provide a cost value within the range 1 to 200000000.​ gen_​text_​input
Hello Time Enter the wait time in seconds between successive BPDU transmissions.​ Valid range is 1 to 10.​ gen_​text_​input
Forward Time Enter the forward time for the MST between 4 and 30.​ The forward time is the forward delay timer period, in seconds.​ gen_​text_​input
Max Age Provide the maximum number of seconds the information in a BPDU is valid, between 6 and 40.​ gen_​text_​input
Link Type.​ Choose one of the link types for PVST: auto, point-to-point or shared.​ If this field is left blank, the default value is used.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NET_​DEVICE_​INTERFACE_​IDENTITY Identity for network interface.​ Infra​Network​Interface​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure Session Pool Properties

Summary
Configure session pool properties.
Description
This task configures session pool properties such as maximum active session and maximum wait time.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Maximum Active Sessions Enter the maximum active sessions count.​ A default value of 5 is set if this field is left blank.​
Maximum Wait Time Enter the maximum wait time in milliseconds.​ A default value of 15 seconds is set if this field is left blank.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​MAX_​ACTIVE_​SESSION Identity for Maximum Active Session.​ gen_​text_​input
OUTPUT_​WAIT_​TIME Identity for Maximum Wait Time.​ gen_​text_​input

Configure Smart Call Home Contact Information

Summary
Configure Smart Call Home contact information on a Nexus device.
Description
This task configures Smart Call Home contact information on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
SNMP sys​Contact Enter a SNMP system contact name.​ gen_​text_​input Y
Email Contact Enter an email address.​ For example: abc@xyz.​com.​ email_​address_​list Y
International Phone Number Enter an international phone number in international format, including country code.​ For example: +1-800-123-4567.​ gen_​text_​input Y
Street Address Enter a Street address.​ gen_​text_​input Y
Contract Number Enter a contract number.​ gen_​text_​input
Customer Number Enter a customer number.​ gen_​text_​input
Site Number Enter a site number.​ gen_​text_​input
Switch Priority Number Enter a switch priority number between 0 to 7.​ Default and highest priority value is 7.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Commit Check this option to commit.​ By default, this field is unchecked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SYS_​CONTACT SNMP sys​Contact.​ gen_​text_​input

Configure System Level HA

Summary
Configure system level HA on a Nexus 1oooV device.
Description
This task configures system level HA on a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Role Choose an HA supervisor role: Standalone, Primary or Secondary.​ By default Standalone is selected.​ setting is activated on next reload while changing the role from primary to secondary.​ gen_​text_​input Y
System Switchover Check this for manual switchover.​ By default this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​HA_​ROLE The High Availability Role that was configured.​ nexus_​vdc

Configure Trunk

Summary
Configure a trunk on an ethernet or port channel interface.
Description
This task configures a trunk on an ethernet or port channel interface on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Port Name Select a port to configure trunk.​ networking_​device_​interface Y
Description Enter additional description to the configured trunk.​ gen_​text_​input
Native VLAN ID Choose a native VLAN ID.​ vlan​ID Y
Allowed VLANs Select list of VLAN to be allowed in trunk mode gen_​text_​input Y
STP Port Type Choose a port type for spanning tree protocol use.​ Port types are edge, network and normal.​ default is edge.​ gen_​text_​input
MTU Enter a MTU range within the range 1500 to 9216.​ gen_​text_​input
Select Port Channel Select a port channel.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Force VLAN Check this option for Force VLAN.​ If checked the existing allowed VLANs associated with the interface get removed and only the newly selected allowed VLANs are added.​ By default, this field is unchecked.​ Boolean
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
NATIVE_​VLAN_​ID Native VLAN ID on which the selected operation was performed gen_​text_​input
ALLOWED_​VLAN_​IDS Allowed VLAN IDsf on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface
OUTPUT_​NET_​DEVICE_​INTERFACE_​IDENTITY Identity for network interface.​ Infra​Network​Interface​Identity

Configure VPC Domain

Summary
Configure a VPC domain.
Description
This task configures a virtual port channel (VPC) domain on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Domain ID Provide a domain ID as anumeric values between 1 and 1000.​ gen_​text_​input Y
Source Management IP Address Enter the source management IP address in the format i.​i.​i.​i.​ For example: 10.​20.​4.​5.​ ipaddress Y
Destination Management IP Address Enter the destination management IP address in the format i.​i.​i.​i.​ For example: 10.​20.​4.​5.​ ipaddress Y
Role Priority Provide a role priority as a numeric values between 1 and 65535.​ gen_​text_​input Y
System Priority Enter a system priority between 1 and 65535.​ gen_​text_​input
Delay Restore Enter the delay restore range between 1 and 3600.​ gen_​text_​input
Peer Gateway Check this option to provide a peer gateway.​ By default, this field is unchecked.​ Boolean
Auto Recovery Check this option to enable auto-recovery.​ By default, this field is unchecked.​ Boolean
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​ Boolean
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VPC_​DOMAIN_​ID VPC Domain ID gen_​text_​input
SOURCE_​MANAGEMENT_​IP Source management IP address on which selected operation was performed.​ gen_​text_​input
DESTINATION_​MANAGEMENT_​IP Destination management IP address on which selected operation was performed.​ gen_​text_​input
VPC_​DOMAIN_​ROLE_​PRIORITY Role priority of VPC domain on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure VPC PortChannel

Summary
Configure a vPC in a Nexus device.
Description
This task configures a vitual port channel (vPC) in a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Channel Name Select a port channel name Infra​Network​Interface​Identity Y
VPC Peer​Link Check this option to configure the port channel as a VPC peer link.​ By default, this field is checked.​
Enter Domain Id Enter a domain ID between 1 and 4096 gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​NET_​DEVICE_​VPC_​INTERFACE_​IDENTITY VPC Interface Configured.​ networking_​device_​vpc_​interface

Configure VTP

Summary
Configure the VTP for a Nexus device.
Description
This task configures the VLAN trunking protocol (VTP) for a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Enable VTP Feature Check this option to enable or disable the VTP feature.​ By default, this field is unchecked.​ Y
Domain Name Provide a domain name for the VTP protocol gen_​text_​input
VTP Version.​ Choose the VTP version gen_​text_​input
File Name Provide a file name for the VTP protocol gen_​text_​input
Password Provide a password for the VTP protocol gen_​text_​input
VTP mode.​ Enter any of the listed learning mode for the VLANs: client, server, transparent or off.​ If this field is left blank, the default value 'client' is used.​ gen_​text_​input
Pruning Check this to perform pruning for the VTP.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Configure VXLAN Range

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Configure VXLAN Check this to configure the VXLAN.​ By default this field is checked.​ Boolean
VXLAN Id Enter the VXLAN ID ranges between 4096 and 16777215.​ For example: 5089-10809.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VXLAN_​ID VXLAN ID on which the selected operation was performed vlan​ID

Convert To Smart Zone

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Type Choose one of the listed zone types: vsan, Fcalias, zone or zoneset.​ If this field is left blank, the value defaults to vsan.​ gen_​text_​input Y
VSAN Id Select the VSAN ID gen_​text_​input Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
SAN_​ZONE_​NAME SAN Zone Name on which the selected operation was performed gen_​text_​input
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Copy Running To Startup Configuration

Summary
Copies the running configuration to the startup configuration.
Description
This task copies the device's running configuration to its startup configuration. This task can be used as last task of network configuration workflow and make the configuration changes permanent to the device flash.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Outputs
No Outputs

Create ACL Entry

Summary
Create an ACL entry.
Description
This task creates an ACL entry.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
ACL Name Enter an ACL name gen_​text_​input Y
Type Choose an ACL entry type.​ Valid values are IP, IPv6 and MAC.​ The default is IP.​ gen_​text_​input
Action Choose a permit or deny action for the rule.​ The default is permit.​ gen_​text_​input
Protocol Choose a protocol for the rule.​ Valid values are tcp, udp, ip and ipv6.​ The default is ip.​ gen_​text_​input
Source Type Choose a source type.​ Valid values are any, network prefix, network address and host.​ The default is any.​ gen_​text_​input
Source Network Prefix Enter a source network prefix for IPv4 in the format A.​B.​C.​D/LEN or IPv6 in the format X:X:X:X:X:X:X:X/LEN.​ For example: 10.​23.​2.​4/8 or ab:23:45:fg:kj:ty:99:78/15.​ gen_​text_​input Y
Source Network Address Enter a source network address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78 gen_​text_​input Y
Source Wildcard Bits Enter source wildcard bits in the format A.​B.​C.​D.​ Not applicable to IPv6.​ For example: 10.​20.​2.​3.​ gen_​text_​input Y
Source Host Address Enter a source host address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Destination Type Choose a destination type.​ Valid values are any, network prefix, network address or host.​ The default is any.​ gen_​text_​input
Destination Network Prefix Enter a destination network prefix for IPv4 in the format A.​B.​C.​D/LEN or IPv6 in the format X:X:X:X:X:X:X:X/LEN.​ For example: 10.​23.​2.​4/8 or ab:23:45:fg:kj:ty:99:78/15.​ gen_​text_​input Y
Destination Network Address Enter a destination network address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Destination Wildcard Bits Enter destination wildcard bits in the format A.​B.​C.​D.​ Not applicable to IPv6.​ For example: 10.​20.​2.​3.​ gen_​text_​input Y
Destination Host Address Enter a destination host address for IPv4 in the format A.​B.​C.​D or IPv6 in the format X:X:X:X:X:X:X:X.​ For example: 10.​23.​2.​4 or ab:23:45:fg:kj:ty:99:78.​ gen_​text_​input Y
Description Enter a description for this ACL entry gen_​text_​input
Per ACL Entry stats collection Check this option to collect stats for each ACL entry.​ By default, this field is unchecked.​
Apply ACL to interface Check this option to apply ACL to the interface.​ By default, this field is unchecked.​
Select Interface Choose an interface name networking_​device_​interface
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create Device Alias

Summary
Create a device alias.
Description
This task creates a device alias on a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Device Alias Name Enter a device alias name gen_​text_​input Y
Enter port WWN Enter a port WWN of the form hh:hh:hh:hh:hh:hh:hh:hh.​ For example: 1a:2b:c3:4d:34:56:89:67.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​SAN_​DEV_​ALIAS Device alias on which selected operation performed.​ networking_​san_​device_​alias_​identity
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​MEMBER San Zone Member Configured.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create Device FCAlias

Summary
Create a device fcAlias.
Description
This task creates a fiber channel alias on a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
FC Alias Name Enter a FC alias name.​ gen_​text_​input Y
VSAN Id Select a VSAN ID.​ Valid range is 2 to 4094.​ vsan​ID Y
Member Type Choose a member type.​ Default member type is Device​Alias.​ networking_​device_​member_​type Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​SAN_​FC_​ALIAS FC alias on which selected operation performed.​ FCAlias​Identity

Create HSRP

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Interface Name Select Interface Name for HSRP Configuration.​ Infra​Network​Interface​Identity Y
Enabled HSRPV2 Check the box to enable hsrp version 2.​ By default, the check box is unchecked.​ Boolean
Description Provide Description for the selected Interface gen_​text_​input
Enable Interface Enable Interface.​
Interface IP Address Interface IP Address in Format i.​i.​i.​i.​ ipaddress
IP Network Mask IP network mask in format m.​m.​m.​m ipaddress
HSRP Group Number HSRP Group Number.​ gen_​text_​input Y
Authentication Text Authentication Text.​ password
Preempt Check the box to enable preempt.​ By default, the check box is checked.​ Boolean
Min Preempt Delay Time Min Preempt Delay Time.​ gen_​text_​input
Priority Priority.​ gen_​text_​input
Set Threshold If selected, given threshold values will set otherwise default threshold values will be set i.​e.​, lower :1 , upper : priority.​ Boolean
Lower Threshhold Time Lower Threshhold Time.​ gen_​text_​input
Upper Threshhold Time Upper Threshhold Time.​ gen_​text_​input
Hello Interval Hello Interval.​ gen_​text_​input
Hold Time Interval Hold Time Interval.​ gen_​text_​input
Virtual IP Address Virtual IP Address in Format i.​i.​i.​i.​ ipaddress
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​INTERFACE_​NAME The Interface Name set on the device.​ gen_​text_​input
OUTPUT_​NET_​DEVICE_​INTERFACE_​IDENTITY Identity for network interface.​ Infra​Network​Interface​Identity
OUTPUT_​DESCRIPTION The Interface Description set on the device.​ gen_​text_​input
OUTPUT_​IS_​ENABLE_​INTERFACE The Interface is enabled on the device.​ gen_​text_​input
OUTPUT_​INTERFACE_​IP The Interface IP Address set on the device.​ gen_​text_​input
OUTPUT_​GROUP_​NUMBER The HSRP Group Number set on the device.​ gen_​text_​input
OUTPUT_​HSRP_​GROUP_​NUMBER_​IDENTITY The HSRP Group Number Identity.​ HSRPGroup​Number​Identity
OUTPUT_​AUTHENTICATION_​TEXT The Authentication Text set on the device.​ password
OUTPUT_​PRIORITY The Priority set on the device.​ gen_​text_​input
OUTPUT_​MIN_​PREEMPT_​DELAY_​TIME The Min Preempt Delay Time set on the device.​ gen_​text_​input
OUTPUT_​LOWER_​THRESHHOLD_​PERIOD The Lower Threshhold Period set on the device.​ gen_​text_​input
OUTPUT_​UPPER_​THRESHHOLD_​PERIOD The Upper Threshhold Period set on the device.​ gen_​text_​input
OUTPUT_​HELLO_​INTERVAL The Hello Interval set on the device.​ gen_​text_​input
OUTPUT_​HOLD_​INTERVAL The Hold Interval set on the device.​ gen_​text_​input
OUTPUT_​VIRTUAL_​IP The Virtual IP Address set on the device.​ gen_​text_​input

Create IP Pool Template

Summary
Create an IP pool template on a Nexus 1000V device.
Description
This task creates an IP pool template on a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
IP Pool Template Name Enter the IP pool template name gen_​text_​input Y
Description Enter the IP pool template description gen_​text_​input
IP Address From Range Enter the IP address start as A.​B.​C.​D.​ For example: 2.​3.​4.​5.​ ipaddress Y
IP Address To Range Enter the IP address end as A.​B.​C.​D.​ For example: 4.​4.​5.​2.​ ipaddress Y
Network Address Enter the network IP address as A.​B.​C.​D.​ For example: 182.​4.​3.​22.​ ipaddress Y
Network Subnet Mask Enter the network subnet mask as A.​B.​C.​D.​ For example: 255.​255.​1.​1.​ ipaddress Y
Default Router Enter the Gateway for IP pool template as A.​B.​C.​D.​ For example: 172.​23.​23.​44.​ ipaddress
DNS Server Enter the DNS server IP as A.​B.​C.​D.​ For example: 12.​3.​4.​5.​ ipaddress
DNS Suffix Enter the DNS suffix gen_​text_​input
Netbios Name Server Enter the Net​Bios name server IP as A.​B.​C.​D.​ For example: 12.​3.​4.​5.​ ipaddress
Netbios Choose a Net​Bios state: enabled or disabled.​ By default state is disabled.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​IP_​POOL_​TEMPLATE IP Pool Template gen_​text_​input
HYPERV_​N1K_​IP_​POOL_​TEMPLATE_​IDENTITY IP Pool Template Identity Infra​Network​IPPool​Template​Identity

Create Logical Network

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Logical Network Name Enter the Logical network name gen_​text_​input Y
Logical Network Description Enter the Logical network description gen_​text_​input
No Mode Isolation Check this for No mode isolation: unchecked by default.​ configures HNV Logical network.​ Supported version: Nexus1000v Hyper​V 5.​2(1)SM3(1.​1) and later.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​LOGICALNETWORK Logical Network gen_​text_​input
HYPERV_​N1K_​LOGICALNETWORK_​IDENTITY Logical Network Identity hyperv_​n1k_​logical_​network_​identity
HYPERV_​LOGICAL_​NETWORK_​IDENTITY Hyper​V Logical Network Identity hyperv​Logical​Network​Identity

Create Loopback Interface

Summary
Create Loopback Interface
Description
This task creates a Loopback Interface.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Loopback Interface Number Enter a loopback interface number.​ gen_​text_​input Y
Description Provide Description gen_​text_​input
IP Address Eg: IPv4/Subnet <20.​20.​20.​0/8> gen_​text_​input
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
LOOPBACK_​INTERFACE_​NUMBER Loop Back Interface Number on which the selected operation was performed gen_​text_​input
OUTPUT_​NET_​DEVICE_​INTERFACE_​IDENTITY Identity for network interface.​ Infra​Network​Interface​Identity
LOOPBACK_​INTERFACE_​NUMBER_​IDENTITY Loop Back Interface Identity Loop Back Interface Identity

Create N1K HyperV Port Profile

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Port Profile Name Enter the port profile name gen_​text_​input Y
Description Enter the port profile description gen_​text_​input
Port Profile Type Choose a port profile type: Ethernet or Vethernet.​ By default Ethernet is selected.​ networking_​device_​port_​profile_​type Y
Channel Group Mode Choose a channel group mode: Sub-Group or MAC-Pinning.​ By default Sub-Group is selected.​ gen_​text_​input
Sub Group Type Choose a sub group type: CDP or Manual.​ By default CDP is selected.​ gen_​text_​input
Publish Port Profile Check this to publish port profile.​ By default this field is unchecked.​ gen_​text_​input
Publish Port Profile Name Enter the port profile name to publish gen_​text_​input
Mode Choose a mode of the port profile: Trunk or Access.​ By default trunk is selected.​ networking_​device_​port_​profile_​mode
Enable VXLAN Capability Check this to enable VXLAN capability.​ By default VXLAN is disabled.​ Boolean
Access VLAN Choose an access VLAN vlan​ID Y
Allowed VLANs Check one or more allowed VLANs vlan​ID Y
Add to System VLAN Check this to add the selected VLANs to system VLANs.​ By default this field is unchecked.​
System VLANs Check one or more system VLANs vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
VLAN_​ID_​LIST VLAN IDs on which the selected operation was performed vlan​ID
HYPERV_​PORT_​PROFILE_​IDENTITY Hyper​V Port Profile Identity hyperv​Vna​Port​Profile​Identity

Create N7K VDC

Summary
Create a VDC for a Nexus 7000 device.
Description
This task creates a virtual device context (VDC) for a Nexus 7000 device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VDC Name Provide a VDC name gen_​text_​input Y
Module Type Enter one or more of these module types, separated with commas: f1, f2, f2e, m1, m1x1 or m2x1.​ For example: f2e, m2x1.​ If this field is left blank, the default value is used.​ gen_​text_​input
HA Policy Check this option to enable the high availability policy.​ By default, this field is unchecked.​
Select Type Enter one of the listed HA types: dual-sup or single-sup.​ If this field is left blank, the value defaults to dual-sup.​ gen_​text_​input Y
Select HA Policy Action Enter an HA policy action: bringdown, reload or restart.​ If this field is left blank, the value defaults to bringdown.​ gen_​text_​input Y
VDC Number Provide a VDC number.​ Use only numbers in this field.​ If this field is left blank, the value defaults to the first available number.​ gen_​text_​input
VDC password Provide a VDC password password Y
VDC Template Name Enter the VDC template name.​ If no template is specified, the default resource template is used.​ gen_​text_​input
Select VDC Type Enter a VDC Type as storage if the VDC is a storage VDC.​ If this field is left blank, the VDC defaults to default VDC.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create Network Segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Network Segement Name Provide Network Segment Name gen_​text_​input Y
Network Segment Description Provide Network Segment Description gen_​text_​input
Network Segment Type Choose a network segment type: either Ethernet or Vethernet.​ By default none is selected.​ gen_​text_​input
IP Address / Subnet Enter the IP address and subnet in the format X.​X.​X.​X/Y.​ For example: 172.​23.​24.​1/32.​ gen_​text_​input
IP Pool Template Name Choose an IP Pool template Infra​Network​IPPool​Template​Identity
Network Segment Pool Name Choose a network segment Pool hyperv_​n1k_​network_​segment_​pool_​identity
Tenant VRF Name Choose a Tenant VRF hyperv_​n1k_​tenant_​vrf_​identity
System Network Segment Check this option to enable system network segmentt
Type Choose a segment type: VLAN, VXLAN or HNV.​ VLAN is selected by default.​ VXLAN and HNV Segment Types Supported Version: Nexus1000v Hyper​V 5.​2(1)SM3(1.​1) or later.​ gen_​text_​input Y
Vlan Enter a VLAN range between 1 and 4096 vlan​ID
Segement ID Enter the segment ID between 4097 and 16777215 gen_​text_​input
Private VLAN Type Choose a private VLAN type: Primary or Secondary.​ By default primary is selected.​ gen_​text_​input
Secondary VLAN Type Choose a secondary VLAN type: host or promiscuous.​ By default host is selected.​ gen_​text_​input
Host Type Choose a host type: Community or Isolated.​ By default Community is selected.​ gen_​text_​input
Primary VLAN Enter the primary VLAN details vlan​ID
Secondary VLAN Enter the secondary VLAN details vlan​ID
Publish Network Segment Check this to publish the network segment.​ By default this field is unchecked.​
Publish Network Segment Name Enter the publish network segment name gen_​text_​input
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​SEGMENT Network Segment gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​IDENTITY Network Segment Identity hyperv_​n1k_​network_​segment_​identity
HYPERV_​N1K_​IP_​POOL_​TEMPLATE IP Pool Template gen_​text_​input
HYPERV_​N1K_​IP_​POOL_​TEMPLATE_​IDENTITY IP Pool Template Identity Infra​Network​IPPool​Template​Identity
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL Network Segment Pool gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL_​IDENTITY Network Segment Pool Identity hyperv_​n1k_​network_​segment_​pool_​identity
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​DEVICE_​VLAN_​IDENTITY Identity for device vlan Infra​Network​VLANIdentity
PRIMARY_​VLAN_​ID Primary VLAN ID on which the selected operation was performed vlan​ID
SECONDARY_​VLAN_​ID Secondary VLAN ID on which the selected operation was performed vlan​ID
HYPERV_​LOGICAL_​NETWORK_​IDENTITY Hyper​V Logical Network Identity hyperv​Logical​Network​Identity
HYPERV_​LOGICALNETWORK_​DEF_​IDENTITY Hyper​V Network Segment Pool Identity hyperv​Logical​Network​Def​Identity
HYPERV_​IP_​POOL_​IDENTITY Hyper​V IP Pool Template Identity hyperv​Ip​Pool​Identity
HYPERV_​VM_​NETWORK_​IDENTITY Hyper​V VM Network Identity hyperv​VMNetwork​Identity

Create Network Segment Pool

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Network Segment Pool Name Enter the network segment Pool name gen_​text_​input Y
Logical Network Name Choose a Logical network hyperv_​n1k_​logical_​network_​identity
Segment Type Choose a segment type: VLAN, VXLAN or HNV.​ VLAN is selected by default.​ VXLAN and HNV Segment Types Supported Version: Nexus1000v Hyper​V 5.​2(1)SM3(1.​1) or later.​ gen_​text_​input
Multicast IP Enter the multicast ip in the format x.​x.​x.​x.​ For example: 239.​1.​1.​1.​ ipaddress
Intra Port Communication Check this for intra-port communication.​ By default this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​LOGICALNETWORK Logical Network gen_​text_​input
HYPERV_​N1K_​LOGICALNETWORK_​IDENTITY Logical Network Identity hyperv_​n1k_​logical_​network_​identity
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL Network Segment Pool gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL_​IDENTITY Network Segment Pool Identity hyperv_​n1k_​network_​segment_​pool_​identity

Create Port Channel

Summary
Create a port channel.
Description
This task creates a port channel on network device and adds a description to it.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Port Channel Number Enter a port channel number between 1 and 4096.​ Default value is 1.​ gen_​text_​input Y
Description Enter addition description to Port Channel.​ gen_​text_​input
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​CHANNEL_​ID Port channel number gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface

Create Port Profile

Summary
Create a port profile on a Nexus device.
Description
This task creates and enables a port profile on a Nexus device. The port profile is available as a distributed port group on vCenter if there is a connection between the VSM and vCenter.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Port Profile Name Enter name for port profile gen_​text_​input Y
Description Enter description for this port profile gen_​text_​input
Type Select the type of port profile networking_​device_​port_​profile_​type
Mode Select the mode of port profile networking_​device_​port_​profile_​mode
Enable VXLAN Capability Enable / Disable the VXLAN Capability.​
IP address IP address in format i.​i.​i.​i ipaddress
IP network mask IP network mask in format m.​m.​m.​m ipaddress
IP next-hop address IP next-hop address in format i.​i.​i.​i ipaddress
Access VLAN Select VLAN vlan​ID Y
Allowed VLANs Select list of VLAN to be allowed in trunk mode vlan​ID Y
QOS Policy Map Select input QOS policy map gen_​text_​input
Add to System VLAN Select this option to add the selected VLANs to System VLAN
System VLANs Select list of Allowed VLANs to be added to system VLAN vlan​ID Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
VLAN_​ID_​LIST VLAN IDs on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​NAME Network device name on which selected operation is performed.​ networking_​device_​name
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​SGT_​IDENTITY SGT Identity.​ security​Grouptag​ID
PORT_​PROFILE_​TYPE Name of the port profile type networking_​device_​port_​profile_​type
PORT_​PROFILE_​MODE Name of the port profile mode networking_​device_​port_​profile_​mode

Create Private VLAN

Summary
Create a private VLAN on a Nexus device.
Description
This task creates a primary or secondary private VLAN on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VLAN ID Enter a valid VLAN ID between 1 and 3967 or 4048 and 4093.​ vlan​ID Y
Private VLAN Type Choose the private VLAN type: primary or secondary.​ Primary is the default.​ Y
Overwrite Existing Private VLAN Check this to overwrite the existing private VLAN.​ By default this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create SAN Zone

Summary
Create a SAN zone on a Nexus device to VSAN.
Description
This task creates a SAN zone on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Zone Name Enter the Zone Name gen_​text_​input Y
VSAN Id Select the VSAN ID gen_​text_​input Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
SAN_​ZONE_​NAME SAN Zone Name on which the selected operation was performed gen_​text_​input
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create SAN Zone Set

Summary
Create a SAN zone set on a Nexus device to VSAN.
Description
This task creates a SAN zone set on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Zone Set Name Enter the Zone set name gen_​text_​input Y
VSAN Id Select the VSAN ID gen_​text_​input Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
SAN_​ZONE_​SET_​NAME SAN Zone Set Name on which the selected operation was performed gen_​text_​input
OUTPUT_​SANZONE_​SET_​IDENTITY Identity for San Zone Set.​ network​SANZone​Set​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create SVI

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
VLAN Interface Number VLAN Interface Number gen_​text_​input Y
VRF Name Provide VRF Context Name networking_​vrf_​identity
ICMP Redirect Check the box to enable ICMP Redirect.​ By default, the check box is unchecked.​ Boolean
IP Address Eg: IPv4/Subnet 10.​10.​10.​0/255.​255.​255.​0,20.​20.​20.​0/8 or IPv6/Subnet X:X:X:X::X/(0-128),Y:Y::/(0-128),Z:Z:Z:Z:Z:Z:Z:Z/(0-128) gen_​text_​input
Description Provide Description gen_​text_​input
OSPF Check the box to enable OSPF.​ By default, the check box is unchecked.​ Boolean
Passive-interface Check the box to enable passive-interface.​ By default, the check box is unchecked.​ Boolean
OSPF Priority Enter an OSPF priority range between (0-255).​ gen_​text_​input
OSPF Process ID Enter a OSPF process id gen_​text_​input
Area Enter a area as an integer or ip address in the format A.​B.​C.​D or (0-4294967295) gen_​text_​input
Multi-Area Enter a multi area as an integer or ip address in the format A.​B.​C.​D or (0-4294967295) gen_​text_​input
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VLAN_​INTERFACE_​NUMBER VLAN Interface Number on which the selected operation was performed gen_​text_​input
OUTPUT_​NET_​DEVICE_​INTERFACE_​IDENTITY Identity for network interface.​ Infra​Network​Interface​Identity
OUTPUT_​DESCRIPTION The Interface Description set on the device.​ gen_​text_​input
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input
OUTPUT_​CREATE_​VRF_​IDENTITY Create VRF Identity created on the device.​ networking_​vrf_​identity

Create SXP Connection Peer

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Enable Device Tracking Check this option to enable device tracking.​ By default, this field is unchecked.​
Delete Hold Period Enter the delete hold timer period within the range (0-64000) gen_​text_​input
Enable SXP Check this option to enable SXP.​ By default, this field is checked.​
Default Source IP Address Enter the default SXP connection peer source IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4.​ ipaddress
Default Password Enter the default password password
Peer IP Address Enter the SXP Connection Peer IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4 ipaddress Y
Source IP Address Enter the SXP connection peer source IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4 ipaddress
Password Option Choose one of the listed password options: default, None or Required.​ If this field is left blank, the value defaults to None.​ gen_​text_​input Y
Required Password Enter the Required password password Y
Mode Enter one of the listed modes: Speaker or Listener.​ If this field is left blank, the default value 'Listener' is used gen_​text_​input Y
VRF Enter the VRF name gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​ISDEVICE_​TRACKING_​ENABLE The Device Tracking enabled on the device.​ gen_​text_​input
OUTPUT_​DELETE_​HOLD_​PERIOD The Delete Hold Timer set on the device.​ gen_​text_​input
OUTPUT_​ISSXP_​ENABLE The SXP is enabled on the device.​ gen_​text_​input
OUTPUT_​DEFAULT_​SOURCE_​IP The Default Source IP created on the device.​ ipaddress
OUTPUT_​DEFAULT_​PASSWORD The Default Password created on the device.​ password
OUTPUT_​PEER_​IP The Peer IP created on device.​ ipaddress
OUTPUT_​SXP_​CONNECTION_​PEER_​IDENTITY The SXP Connection Peer Identity.​ Sxp​Connection​Peer​Identity
OUTPUT_​SOURCE_​IP The Source IP created on the device.​ ipaddress
OUTPUT_​PASSWORD_​OPTION The Password Option created on the device.​ gen_​text_​input
OUTPUT_​REQUIRED_​PASSWORD The Required Password created on the device.​ password
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input

Create Static MACAddress

Summary
Create a static MAC address on a Nexus device.
Description
This task creates a static MAC address entry on a Nexus device. An existing VLAN ID is required.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Select a port networking_​device_​interface Y
MAC Address Enter a MAC address in one of these formats: E.​E.​E, EE-EE-EE-EE-EE-EE, EE:EE:EE:EE:EE:EE or EEEE.​EEEE.​EEEE.​ For example: 00-15-E9-2B-99-3C gen_​text_​input Y
VLAN ID Select a VLAN ID Infra​Network​VLANIdentity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​MACADDRESS Network device MAC Address on which selected operation performed.​ networking_​device_​mac
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create Tenant VRF

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Tenant VRF Name Enter the Tenant VRF name gen_​text_​input Y
Description Enter the Tenant VRF description gen_​text_​input
Logical Network Name Choose a Logical network hyperv_​n1k_​logical_​network_​identity
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​TENANT_​VRF Tenant VRF gen_​text_​input
HYPERV_​N1K_​NETWORK_​TENANT_​VRF_​IDENTITY Tenant VRF Identity hyperv_​n1k_​tenant_​vrf_​identity
HYPERV_​N1K_​LOGICALNETWORK Logical Network gen_​text_​input
HYPERV_​N1K_​LOGICALNETWORK_​IDENTITY Logical Network Identity hyperv_​n1k_​logical_​network_​identity

Create Uplink Network

Create VFC Interface

Summary
Create a VFC on a Nexus device.
Description
This task creates a virtual fiber channel (VFC) interface on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VFC Id Provide a VFC ID between 1 and 8192 gen_​text_​input Y
Select Port Enter a port in this format: datacenter@device_​ip@hardware@interface.​ For example: Default​Pod@172.​29.​195.​162@1000/10000 Ethernet@Ethernet1/10.​ gen_​text_​input Y
Switch Port Mode Enter a switch port mode: E or F.​ If this field is left blank, the value defaults to E.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
VFC_​INTERFACE_​NAME VFC Interface name gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create VLAN

Summary
Create a VLAN.
Description
This task creates a virtual LAN (VLAN) on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
VLAN ID Provide VLAN ID range between 1 and 3967 or 4048 and 4093.​ vlan​ID Y
VLAN Name Enter a VLAN name.​ gen_​text_​input
Overwrite Existing VLAN Check this option to overwrite any existing VLAN configuration.​
No Shutdown Check this option to enable the VLAN.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
VLAN_​NAME VLAN Name on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​DEVICE_​VLAN_​IDENTITY Identity for device vlan Infra​Network​VLANIdentity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create VRF

Summary
Create a VRF.
Description
This task creates a VPN routing and forwarding (VRF).
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
VRF Name Enter a VRF context name gen_​text_​input Y
Domain Name Enter the domain name gen_​text_​input
DNS Servers Enter one or more DNS servers separated with commas or spaces.​ No more than 6 DNS servers are allowed for one VRF.​ For example: cisco.​com, VMware.​org.​ gen_​text_​input
Route Enter a route in this format: A.​B.​C.​D/LEN.​ or example: 13.​2.​3.​1/32.​ gen_​text_​input
Gateway Enter a gateway IP as A.​B.​C.​D.​ For example: 142.​23.​1.​1.​ ipaddress
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input
OUTPUT_​VRF_​IDENTITY The VRF Identity created on the device.​ gen_​text_​input
OUTPUT_​CREATE_​VRF_​IDENTITY Create VRF Identity created on the device.​ networking_​vrf_​identity
OUTPUT_​DOMAIN_​NAME The VRF created on the device.​ gen_​text_​input

Create VSAN

Summary
Create a VSAN.
Description
This task creates a virtual storage area network (VSAN) on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
VSAN ID Provide a VSAN ID between 2 and 4093.​ vsan​ID Y
VSAN Name Enter a VSAN name.​ gen_​text_​input
Enhance Check this option to Enhance the VSAN.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
VSAN_​NAME VSAN Name on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Create VXLAN

Summary
Create a VXLAN on a Nexus 1000V device.
Description
This task creates a VXLAN on a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Provide a domain name for VXLAN bridge gen_​text_​input Y
VXLAN Id Provide a VXLAN ID in the range 4096 to 16000000 gen_​text_​input Y
Mode Unicast Check this option to set the unicast mode for the VXLAN.​ By default, this field is checked.​
VXLAN Group IP Address Provide the multicast IP address for the VXLAN in the format i.​i.​i.​i.​ For example: 224.​0.​0.​5.​ ipaddress Y
Distribution learning MAC Check this option to set floodless learning using the MAC.​ By default, this field is checked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VXLAN_​ID VXLAN ID on which the selected operation was performed vlan​ID
VXLAN_​DOAMIN_​NAME VXLAN Domain Name on which the selected operation was performed gen_​text_​input

Create VXLAN Encapsulate segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Select the domain name for the VXLAN bridge.​ gen_​text_​input Y
Encapsulation profile Segment Enter the encapsulation profile segment gen_​text_​input Y
VLAN ID Select the VLAN ID Infra​Network​VLANIdentity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME Name of the encapsulation profile segment on which the selected operation was performed gen_​text_​input
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME_​IDENTITY Name of the encapsulation profile segment on which the selected operation was performed infra_​network_​encapsulation_​profile_​segment_​name

Delete ACL Entry

Summary
Delete an ACL entry.
Description
This task deletes an ACL entry.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
ACL Name Choose an ACL name for deletion gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Associate Private VLAN

Summary
Delete an associated private VLAN.
Description
This task deletes the association of the primary VLAN to a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Primary VLAN ID Enter a VLAN ID between 1 and 3967 or 4048 and 4093 to delete the association.​ vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Device Alias

Summary
Delete a device alias.
Description
This task deletes a device alias on a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Device Alias Name Select one or more device alias name(s).​ networking_​san_​device_​alias_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​SAN_​DEV_​ALIAS Device alias on which selected operation performed.​ networking_​san_​device_​alias_​identity
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Device FCAlias

Summary
Delete a device fcAlias.
Description
This task deletes a fiber channel alias from a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
FC Alias Name Choose an FC alias name FCAlias​Identity
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Host Name

Summary
Delete a host name on a Nexus device.
Description
This task deletes a host name on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Host Name Select Host Name to be deleted networking_​device_​host_​name Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
HOST_​NAME Host Name on which the selected operation was performed networking_​device_​host_​name
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete IP ACL Rule

Summary
Delete an IP ACL Rule from a Nexus 1000V device.
Description
This task deletes an IP access control list (ACL) rule for Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select IP ACL Rule Choose an IP ACL rule for deletion networking_​nxos_​ip_​acl_​info Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input

Delete IP Pool Template

Summary
Delete an IP pool template on a Nexus 1000V device.
Description
This task deletes an IP pool template from a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Select IP Pool Template Name Choose an IP Pool template to delete Infra​Network​IPPool​Template​Identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​IP_​POOL_​TEMPLATE IP Pool Template gen_​text_​input
HYPERV_​N1K_​IP_​POOL_​TEMPLATE_​IDENTITY IP Pool Template Identity Infra​Network​IPPool​Template​Identity

Delete Inherit Port Profile

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Network Uplink Choose a network uplink to delete the associated port profile hyperv_​n1k_​network_​uplink_​identity Y
Port Profile Choose a port profile Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
HYPERV_​N1K_​NETWORK_​UPLINK Network Uplink gen_​text_​input
HYPERV_​N1K_​NETWORK_​UPLINK_​IDENTITY Network Uplink Identity hyperv_​n1k_​network_​uplink_​identity

Delete Logical Network

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Logical Network Name Choose a Logical network to delete hyperv_​n1k_​logical_​network_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​LOGICALNETWORK Logical Network gen_​text_​input
HYPERV_​N1K_​LOGICALNETWORK_​IDENTITY Logical Network Identity hyperv_​n1k_​logical_​network_​identity

Delete Loopback Interface

Summary
Delete Loopback Interface.
Description
This task deletes a Loopback Interface.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Loopback Interface Select a loopback interface to be deleted.​ Loop Back Interface Identity Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Delete MAC ACL Rule

Summary
Delete a MAC ACL Rule from a Nexus 1000V device.
Description
This task deletes a MAC access control list (ACL) rule from a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select MAC ACL Rule Choose a MAC ACL rule for deletion networking_​nxos_​mac_​acl_​info Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​ACL_​NAME ACL on which selected operation performed.​ gen_​text_​input

Delete N9K QOS Profile

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Platinum Class Check this option to configure platinum class parameters.​ By default, this field is unchecked.​
Configure Gold Class Check this option to configure gold class parameters.​ By default, this field is unchecked.​
Configure Silver Class Check this option to configure silver class parameters.​ By default, this field is unchecked.​
Configure Default Class Check this option to configure default class parameters.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Request Approval Check this option to request approval to deliver commands to the device.​ By default, this field is unchecked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Delete NAT

Summary
Delete a NAT table.
Description
This task deletes a NAT table from a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select NAT Select a NAT to be deleted.​ asa_​device_​nat_​context Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​SECURITY_​CONTEXT_​NAME Security Context name on which selected operation performed.​ networking_​security_​context_​name
OUTPUT_​NAT_​REAL_​INTERFACE_​IDENTITY ASA NAT REAL INTERFACE IDENTITY Network​Named​Interface​Identity
OUTPUT_​NAT_​MAPPED_​INTERFACE_​IDENTITY ASA NAT MAPPED INTERFACE IDENTITY Network​Named​Interface​Identity
OUTPUT_​NAT_​SOURCE_​REAL_​OBJECT_​IDENTITY NAT SOURCE REAL NETWORK OBJECT IDENTITY NATSource​Or​Destination​Identity
OUTPUT_​NAT_​SOURCE_​MAPPED_​OBJECT_​IDENTITY NAT SOURCE MAPPED NETWORK OBJECT IDENTITY NATSource​Or​Destination​Identity

Delete NTP Configurations

Summary
Delete an NTP configuration from a Nexus device.
Description
This task deletes an NTP configurations from a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
NTP Server IP Select a NTP server IP to be deleted.​ networking_​ntp_​peer_​identity
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NTP_​SERVER_​IP NTP server IP ipv4Address

Delete Network Element

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Delete Network Segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a Networking device networking_​device Y
Network Segment Choose a network segment to delete hyperv_​n1k_​network_​segment_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​SEGMENT Network Segment gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​IDENTITY Network Segment Identity hyperv_​n1k_​network_​segment_​identity

Delete Network Segment Pool

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Network Segment Pool Name Choose a network segment pool to delete hyperv_​n1k_​network_​segment_​pool_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL Network Segment Pool gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL_​IDENTITY Network Segment Pool Identity hyperv_​n1k_​network_​segment_​pool_​identity

Delete Port Channel

Summary
Delete a port channel.
Description
This task deletes a port channel from a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select Port Channel Name Select a port channel for deletion.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Port Profile

Summary
Delete the port profile from a Nexus device.
Description
This task deletes a port profile from a Nexus switch.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Select Port Profile Select a port profile for deletion infra_​network_​port_​profile_​name Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Private VLAN

Summary
Delete a private VLAN from a device.
Description
This task delete a private VLAN from a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VLAN ID Choose a private VLAN to delete vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete SAN Zone

Summary
Delete a SAN zone.
Description
This task deletes a zone under a VSAN on a networking device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select the networking device.​ networking_​device Y
SAN Zone Select a SAN zone.​ network​SANZone​Identity Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
SAN_​ZONE_​NAME SAN Zone Name on which the selected operation was performed gen_​text_​input
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete SAN Zone Set

Summary
Delete a SAN zone set on a Nexus device.
Description
This task deletes a SAN zone set on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
SAN Zone Set elect one or more SAN Zone set network​SANZone​Set​Identity Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
SAN_​ZONE_​NAME SAN Zone Name on which the selected operation was performed gen_​text_​input
OUTPUT_​SANZONE_​SET_​IDENTITY Identity for San Zone Set.​ network​SANZone​Set​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete Tenant VRF

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Tenant VRF Name Choose a Tenant VRF to delete hyperv_​n1k_​tenant_​vrf_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​TENANT_​VRF Tenant VRF gen_​text_​input
HYPERV_​N1K_​NETWORK_​TENANT_​VRF_​IDENTITY Tenant VRF Identity hyperv_​n1k_​tenant_​vrf_​identity

Delete Uplink Network

Delete VFC Interface

Summary
Delete a VFC interface.
Description
This task deletes a Virtual Fiber Channel (VFC) interface from a configurable fiber channel on ethernet (FCoE) Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select VFC Interface Choose the VFC interface name gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VFC_​INTERFACE_​NAME VFC Interface name gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete VLAN

Summary
Delete a VLAN.
Description
This task deletes a virtual LAN (VLAN) from a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
VLAN ID Choose a VLAN ID to be deleted.​ vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
VLAN_​NAME VLAN Name on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete VRF

Summary
Delete a VRF.
Description
This task removes a VPN routing and forwarding (VRF).
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
VRF Name Choose a VRF context to delete networking_​vrf_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input
OUTPUT_​VRF_​IDENTITY The VRF Identity created on the device.​ gen_​text_​input
OUTPUT_​CREATE_​VRF_​IDENTITY Create VRF Identity created on the device.​ networking_​vrf_​identity

Delete VSAN

Summary
Delete a VSAN.
Description
This task deletes a virtual storage area network (VSAN) on network devices.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
VSAN ID Choose a VSAN ID to be deleted.​ vsan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
VSAN_​NAME VSAN Name on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Delete VXLAN Encapsulate segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
encapsulation profile Segment Select the encapsulation profile segment infra_​network_​encapsulation_​profile_​segment_​name Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME Name of the encapsulation profile segment on which the selected operation was performed gen_​text_​input
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME_​IDENTITY Name of the encapsulation profile segment on which the selected operation was performed infra_​network_​encapsulation_​profile_​segment_​name

Enable SmartZone

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
VSAN ID Choose a VSAN ID to be associated.​ vsan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VSAN_​ID VSAN ID on which the selected operation was performed vsan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Encapsulate VXLAN Port Profile with Segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Profile Choose the port profile name.​ gen_​text_​input Y
encapsulation profile Segment Select the encapsulation profile segment infra_​network_​encapsulation_​profile_​segment_​name Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME Name of the encapsulation profile segment on which the selected operation was performed gen_​text_​input
ENCAPSULATION_​PROFILE_​SEGMENT_​NAME_​IDENTITY Name of the encapsulation profile segment on which the selected operation was performed infra_​network_​encapsulation_​profile_​segment_​name

Encapsulate VXLAN PortProfile

Summary
Encapsulate a VXLAN to a VLAN.
Description
This task encapsulates a VXLAN into a VLAN in a port profile.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Select the domain name for the VXLAN bridge.​ gen_​text_​input Y
Select Port Profile Choose the port profile name.​ gen_​text_​input Y
VLAN ID Select the VLAN ID Infra​Network​VLANIdentity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name

Execute Network Device CLI

Summary
Execute CLI commands on a network device.
Description
This task executes CLI commands on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device(s) Choose a networking device networking_​device Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
CLI Commands Enter the list of commands to execute on the network device Y
Undo CLI Commands Enter the undo CLI commands to execute on the network device
Error Enter the list of error string needs to check on the device response
Outputs
Output Description Type
OUTPUT_​SSH_​COMMAND External service request ID.​ gen_​text_​input

Generic Configure SAN Zoning

Summary
Configure SAN zoning on a UCS CIMC or Nexus device.
Description
This task creates generic SAN zoning on a compute or network device.
Inputs
Input Description Mappable To Type Mandatory
Service Profile Type Choose a service profile type for SAN zoning
Service Profile Choose a service profile ucs​Service​Profile​Identity Y
Global Service Profile Choose a global service profile UCS_​CENTRAL_​SERVICE_​PROFILE_​IDENTITY Y
CIMC Server Choose a CIMC server IP cimc​Server​Identity Y
Configure One to One zones Check this to configure one to one zones
Activate Zone Set Check this to activate the zone set after creation
Commit Zone Check this to commit the zone set after creation
Device Alias Check this to enable device alias
Prefer Smart​Zoning if device supports Check this to enable smart zoning
Select v​HBA Choose the v​HBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx.​ For example: 20:00:00:25:B5:00:0A:1F.​ gen_​text_​input Y
Device Alias Fab A v​HBA Enter a device alias name for the v​HBA - fabric A gen_​text_​input
VSAN ID This is a non-editable field.​ It displays the VSAN associated with the v​HBA.​ gen_​text_​input
Zone Name Enter the zone name for configuration of fabric A gen_​text_​input
Storage Account Type Choose a storage account type: Net​App, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, Xtrem​IO/EMC, VPLEX/IBM Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller.​ By default no account type is selected.​ gen_​text_​input
Storage Account Name (Primary) Choose a primary storage account name for fabric A gen_​text_​input
Storage FC Adapter (Primary) Select a primary storage FC adapter for fabric A GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for the primary FC adapter.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Configure Secondary Head Check this to configure secondary head for fabric A.​ By default this field is unchecked.​
Storage Account Name (Secondary) Choose a secondary storage account name for fabric A gen_​text_​input
Storage FC Adapter (Secondary) Select a secondary storage FC adapter for fabric A GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for secondary FC adapter for fabric A.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Secondary Zone Name Enter the secondary zone name to configure for fabric A gen_​text_​input
Select Device Select device for Fabric A configuration infra​Net​Cisco​San​Device​Identity Y
Select Source Port Choose the source port for fabric A.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN ID for fabric A between 2 and 4093 gen_​text_​input Y
Configure Fabric B Check this to configure fabric B.​ By default this field is unchecked.​ Boolean
Select v​HBA Choose the v​HBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx.​ For example: 20:00:00:25:B5:00:0A:1F.​ gen_​text_​input Y
Device Alias Fab B v​HBA Enter the device alias name for the v​HBA - fabric B gen_​text_​input
VSAN ID This is a non-editable field.​ It displays the VSAN associated with the v​HBA - fabric B.​ gen_​text_​input
Zone Name Enter the zone name for configuring fabric B gen_​text_​input
Storage Account Type Choose a storage account type for fabric B: Net​App, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, Xtrem​IO/EMC, VPLEX/IBM Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller.​ By default none is selected.​ gen_​text_​input
Storage Account Name (Primary) Choose a primary storage account name for fabric B gen_​text_​input
Storage FC Adapter (Primary) Select a primary storage FC adapter for fabric B GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for the primary FC adapter for fabric B.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Configure Secondary Head Check this to configure the secondary head of fabric B.​ By default this field is unchecked.​
Storage Account Name (Secondary) Choose a secondary storage account name for fabric B gen_​text_​input Y
Storage FC Adapter (Secondary) Select a secondary storage FC adapter for fabric B GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for secondary FC adapter for fabric B.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Zone Name Enter the secondary zone name to configure for the fabric B gen_​text_​input
Select Device Select device for Fabric B configuration infra​Net​Cisco​San​Device​Identity Y
Select Source Port Select the source port for fabric B gen_​text_​input Y
Select Mapping VSAN Select a VSAN ID for fabric B between 2 and 4093 gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
FABRIC_​A_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​1_​NAME Name of the zone1 that was created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​2_​NAME Name of the zone2 that was created for fabric A gen_​text_​input
FABRIC_​A_​DEVICE_​IP Switch IP Address (Fabric A) networking_​device
FABRIC_​A_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​1_​IDENTITY Identity for SAN Zone 1 created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​2_​IDENTITY Identity for SAN Zone 2 created for fabric A gen_​text_​input
FABRIC_​B_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​1_​NAME Name of the zone1 that was created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​2_​NAME Name of the zone2 that was created for fabric B gen_​text_​input
FABRIC_​B_​DEVICE_​IP Switch IP Address (Fabric B) networking_​device
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
FABRIC_​B_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​1_​IDENTITY Identity for SAN Zone 1 created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​2_​IDENTITY Identity for SAN Zone 2 created for fabric B gen_​text_​input
OUTPUT_​FAB_​A_​PRIMARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 1 created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​SECONDARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 2 created for fabric A gen_​text_​input
OUTPUT_​FAB_​B_​PRIMARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 1 created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​SECONDARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 2 created for fabric B gen_​text_​input
FABRIC_​B_​VDC_​NAME VDC Name (Fabric B) nxos​VDCIdentity

Inherit Port Profile

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Network Uplink Choose a network uplink hyperv_​n1k_​network_​uplink_​identity Y
Port Profile Choose a port profile infra_​network_​port_​profile_​name Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
HYPERV_​N1K_​NETWORK_​UPLINK Network Uplink gen_​text_​input
HYPERV_​N1K_​NETWORK_​UPLINK_​IDENTITY Network Uplink Identity hyperv_​n1k_​network_​uplink_​identity

Modify Service Policy

Summary
Modify a Service Policy.
Description
This task modifies a Service Policy on a network device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select Interface Select an interface.​ networking_​device_​interface Y
Service Policy type Choose a service policy type as QOS or queuing.​ The default is QOS.​ Y
Service Policy direction Choose a service policy direction as input or output.​ The default is input.​
Select Policy Map Select a service policy map.​ ucs​Policy​Map​Identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​SERVICE_​POLICY_​TYPE Name of service policy on which selected operation was performed.​ gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​POLICY_​MAP Name of policy map on which selected operation was performed.​ gen_​text_​input

Provision Network

Summary
Perform network configuration related to vmWare.
Description
This task configures the VLAN and access control list (ACL) on a device based on the network provisioning policy. When the Network Provisioning Policy is defined with a private VLAN, this task configures both primary and secondary VLANs. If an ESX(i) host is selected, this task configures the VLAN and ACL on a network device associated with the ESX(i) host and creates vSwitches on the host. If network devices are selected, the VLAN and ACL are configured on the device itself. If a Nexus 1000V switch is selected, this task configures port profiles on it.
Inputs
Input Description Mappable To Type Mandatory
Use v​DC Check this option to set the provisioning network v​DC hosts.​ By default, this field is unchecked.​
Select Devices Choose one or more networking devices.​ device​Multi​Select Y
Select v​DC Choose the v​DC to associate with the network.​ v​DC Y
Network Provisioning Policy Enter a network provisioning policy name.​ gen_​text_​input Y
VLAN ID Enter a VLAN ID.​ A value of 0 causes the system to automatically assign an available VLAN ID.​ The valid range is 2 to 4094.​ vlan​ID
v​Switch Name Enter the name of the Vswitch to be created on the selected VMware hosts.​ v​Switch​Name
Outputs
Output Description Type
VLAN_​ID VLAN ID that was created gen_​text_​input
PORT_​GROUP Port group that was created gen_​text_​input
KERNEL_​PORT_​GROUP Kernel Port group that was created gen_​text_​input
OUTPUT_​HOST_​LIST Comma-separated hosts on which network provision is done.​ vm​Host

Publish to SCVMM

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Network Object Choose a network object type to publish gen_​text_​input
Network Uplink Choose a network uplink to publish hyperv_​n1k_​network_​uplink_​identity Y
Port Profile Choose a port profile infra_​network_​port_​profile_​name Y
Network Segment Choose a network segment hyperv_​n1k_​network_​segment_​identity Y
Publish Name Enter the publish name gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
HYPERV_​N1K_​NETWORK_​SEGMENT Network Segment gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​IDENTITY Network Segment Identity hyperv_​n1k_​network_​segment_​identity
HYPERV_​N1K_​NETWORK_​UPLINK Network Uplink gen_​text_​input
HYPERV_​N1K_​NETWORK_​UPLINK_​IDENTITY Network Uplink Identity hyperv_​n1k_​network_​uplink_​identity
HYPERV_​LOGICAL_​NETWORK_​IDENTITY Hyper​V Logical Network Identity hyperv​Logical​Network​Identity
HYPERV_​LOGICALNETWORK_​DEF_​IDENTITY Hyper​V Network Segment Pool Identity hyperv​Logical​Network​Def​Identity
HYPERV_​IP_​POOL_​IDENTITY Hyper​V IP Pool Template Identity hyperv​Ip​Pool​Identity
HYPERV_​VM_​NETWORK_​IDENTITY Hyper​V VM Network Identity hyperv​VMNetwork​Identity
HYPERV_​NETWORK_​UPLINK_​IDENTITY Hyper​V Network Uplink Identity hyperv​Up​Link​Port​Profile​Identity
HYPERV_​PORT_​PROFILE_​IDENTITY Hyper​V Port Profile Identity hyperv​Vna​Port​Profile​Identity

Purge Network Device Configuration Data

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Purge Type Choose a purge type.​ The purge types are date and size, default value is date.​ gen_​text_​input
Date Type Choose a date type.​ The date types are Before Date, After Date and Between Date.​ The default is Before Date.​ gen_​text_​input
Size Type Choose a size type.​ The size types are Greater (size),Lesser (size) and Between (size).​ The default is Greater (size).​ gen_​text_​input
Delete Before Provide a before date.​ date_​time
Delete After Provide an after date.​ date_​time
From Date Provide a from date.​ date_​time
To Date Provide a to date.​ date_​time
Greater Size (Byte) Enter an upper size at which to purge network device configuration data.​ gen_​text_​input
Lesser Size (Byte) Enter a lower size at which purge network device configuration data.​ gen_​text_​input
Between Size (Byte) Enter a size as a range.​ For example: 10-20.​ Network device configuration data that are in this range will be purged.​ gen_​text_​input
Show Report Check this option to show a report.​ By default, this field is unchecked.​ gen_​text_​input
Purge Data Report Select one or more rows to show report.​ gen_​text_​input
Outputs
Output Description Type
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Push NTP Configurations

Summary
Push an NTP configuration to a Nexus device.
Description
This task pushes a network time protocol (NTP) configuration to a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
NTP Server IP Enter an NTP server IP in the format i.​i.​i.​i.​ ipv4Address
NTP Stratum number Enter a stratum number between 1 and 15.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NTP_​SERVER_​IP NTP server IP ipv4Address
OUTPUT_​NTP_​STRATUM_​NUMBER NTP Stratum number.​ gen_​text_​input
OUTPUT_​NTP_​SERVER_​IP_​IDENTITY NTP server IP Identity networking_​ntp_​peer_​identity

Remove HSRP

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
HSRP Group Number HSRP Group Number.​ HSRPGroup​Number​Identity Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove Member From SAN Zone

Summary
Remove a member from a SAN zone on a Nexus device.
Description
This task removes a member from a SAN zone on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
SAN Zone Select a SAN Zone network​SANZone​Identity Y
Type Choose one of the listed type members: p​WWN, FCALIAS or devicealias.​ If this field is left blank, the value defaults to p​WWN.​ gen_​text_​input
FCALIAS Choose one or more FCALIAS FCAlias​Identity
Member Enter the value for the member in this format: hh:hh:hh:hh:hh:hh:hh:hh.​ For example: 11:11:11:11:11:11:11:11.​ gen_​text_​input Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​SANZONE_​MEMBER San Zone Member Configured.​ gen_​text_​input
OUTPUT_​SANZONE_​TYPE San Zone Type Configured.​ gen_​text_​input
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove N7K VDC

Summary
Remove a VDC from a Nexus 7000 device.
Description
This task removes a virtual device context (VDC) from a Nexus 7000 device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VDC Name Select a VDC name nxos​VDCIdentity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove Port From VDC

Summary
Remove a port from a VDC.
Description
This task de-allocates a port from a virtual device channel (VDC).
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VDC Name Select a VDC name nxos​VDCIdentity Y
Select Port Enter a port in this format: datacenter@device_​ip@hardware@interface.​ For example: Default​Pod@172.​29.​195.​162@1000/10000 Ethernet@Ethernet1/10.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove Private VLAN Ports

Summary
Remove private VLANs from a port.
Description
This task removes the private VLANs from a port.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select Port Provide the port to remove private VLAN.​ For example: Ethernet1/23.​ gen_​text_​input Y
Type Choose a private VLAN port type Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove SVI

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VLAN Interface Select the VLAN Interface networking_​vlan_​interface_​identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Remove SXP Connection Peer

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Disable Device Tracking Check this option to disable device tracking.​ By default, this field is unchecked
Remove Delete Hold Period Check this option to remove the delete hold timer period.​ By default, this field is unchecked.​ gen_​text_​input
Disable SXP Check this option to disable SXP.​ By default, this field is unchecked
Remove Default Source IP Address Check this option to remove the default source IP address.​ By default, this field is unchecked Default Source IP Address.​
Remove Default Password Check this option to remove the default password.​ By default, this field is unchecked
Peer IP Address Select the SXP connection peer IP address to be removed.​ Sxp​Connection​Peer​Identity Y
Source IP Address Enter the SXP connection peer source IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4 ipaddress
Password Option Choose one of the listed password options: default, None or Required.​ If this field is left blank, the value defaults to None.​ gen_​text_​input
Required Password Enter the Required password password
Mode Enter one of the listed modes: Speaker or Listener.​ If this field is left blank, the default value 'Listener' is used gen_​text_​input
VRF Enter the VRF name gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove San Zone From Zone Set

Summary
Remove SAN zone from zone set for the Nexus device.
Description
This task removes a SAN zone from a SAN zone set on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
SAN Zone Set Select a SAN Zone Set network​SANZone​Set​Identity Y
SAN Zone Select one or more SAN Zone network​SANZone​Identity Y
Commit San Zone Check this option if the SAN zone mode is enhanced.​ By default, this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​SANZONE_​SET_​IDENTITY Identity for San Zone Set.​ network​SANZone​Set​Identity
OUTPUT_​SANZONE_​IDENTITY Identity for San Zone.​ network​SANZone​Identity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove Static MACAddress

Summary
Remove static MAC address from a Nexus device.
Description
This task removes a static MAC address entry from a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
MAC Address Select a MAC address networking_​device_​mac Y
VLAN ID This field shows the VLAN ID of the selected MAC address.​ This field cannot be modified.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​MACADDRESS Network device MAC Address on which selected operation performed.​ networking_​device_​mac
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove System VLAN Undo Configuration

Summary
Remove VLANs from a trunk on a Nexus 1000V device.
Description
This task removes system VLANs from a trunk on a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Port Profile Name Select the port profile name gen_​text_​input Y
System VLANs Enter a list of system VLANs to be removed between 0 and 4094, separated by commas.​ For example: 5, 30.​ vlan​ID Y
Select N1K Uplink Switch A Select the N1K Uplink Switch A Device networking_​device Y
Select Trunk Interface Select one or more trunk interface from which control vlan need to be removed.​ gen_​text_​input Y
Control VLAN ID Select Control VLAN ID to be removed from the trunk vlan​ID Y
Select N1K Uplink Switch B Select a N1K Uplink Switch B Device
Select Uplink Switch B Select Uplink Switch B Device networking_​device Y
Select Trunk Interface Select trunk interface from which control vlan need to be removed.​ gen_​text_​input Y
Control VLAN ID Select one or more Control VLAN ID to be removed from the trunk vlan​ID Y
Outputs
No Outputs

Remove System VLAN from Port Profile

Summary
Remove system VLANs from a port profile.
Description
This task removes system VLANs from a port profile on a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Select Port Profile Select the port profile name gen_​text_​input Y
Select VLANs Enter a list of system VLANs to be removed between 0 and 4094, separated by commas.​ For example: 5, 30.​ vlan​ID Y
Select N1K Uplink Switch A Select the N1K Uplink Switch A Device networking_​device Y
Select Trunk Interface Select one or more trunk interface from which control vlan need to be removed.​ gen_​text_​input Y
Control VLAN ID Select Control VLAN ID to be removed from the trunk vlan​ID Y
Select N1K Uplink Switch B Check this option to enable the N1K uplink switch B device.​ By default, this field is unchecked
Select N1K Uplink Switch B Select the N1K Uplink Switch B Device networking_​device Y
Select Trunk Interface Select one or more trunk interface from which control vlan need to be removed.​ gen_​text_​input Y
Control VLAN ID Select Control VLAN ID to be removed from the trunk vlan​ID Y
Outputs
No Outputs

Remove VPC PortChannel

Summary
Remove VPC PortChannel.
Description
This task removes a virtual port channel (VPC) from a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Channel Name Enter a port channel name in this format: datacenter@device_​ip@port_​channel_​number@peer_​link@v​PC_​domain_​id.​ For example: Default​Pod@172.​29.​195.​162@Po14@No@15.​ gen_​text_​input Y
VPC Peer​Link Check this option to configure the port channel as a VPC peer link.​ By default, this field is checked.​
Domain Id This field shows the domain ID of the configured v​PC port channel.​ This field cannot be modified.​ Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Remove VXLAN

Summary
Remove a VXLAN from a Nexus 1000V device.
Description
This task removes a VXLAN from a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Select the domain name for the VXLAN bridge.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

Reset Password

Summary
Reset a password.
Description
This task resets a password on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select User Name Select user name password_​reset_​username Y
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​USERNAME Password Reset User Name password_​reset_​username

Switch Port Action

Summary
Configure a switch port to UP or DOWN.
Description
This task configures the administrative UP or DOWN state on a switch port.
Inputs
Input Description Mappable To Type Mandatory
Select Switch Port Choose a switch port.​ switch​Port Y
Switch Port Action Choose a switch port action, either Up or Down.​ The default value is Up.​ Y
Outputs
No Outputs

UnAssign MACAddress Port

Summary
Remove a static MAC address from the layer 3 interface on a Nexus device.
Description
This task removes the static MAC address entry from a layer 3 interface on a Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Select a port networking_​device_​interface Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NETWORKING_​DEVICE_​INTERFACE Network device interface on which selected operation performed.​ networking_​device_​interface
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

UnAssign VXLAN PortProfile

Summary
Remove the assignment of a VXLAN from a PortProfile Nexus device.
Description
This task removes the assignment of a VXLAN from a PortProfile Nexus device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Select Port Profile Choose the port profile name.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device

UnAssociate VSAN from VLAN

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Vlan Select a VLAN ID vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​DEVICE_​VLAN_​IDENTITY Identity for device vlan Infra​Network​VLANIdentity
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Unassign VLAN from Group

Summary
Unassign a VLAN from a UCS Director group.
Description
This task unassigns a VLAN from a UCS Director group.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
VLAN ID Choose the VLAN ID.​ The valid range is between 1 and 3967 or 4048 and 4093.​ vlan​ID Y
Comments Enter comments gen_​text_​input
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID

Update Device FCAlias

Summary
Update a device fcAlias.
Description
This task updates a fiber channel alias on a device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
FC Alias Name Choose an FC alias name FCAlias​Identity Y
Members list Provide one or more member details that can be associated with the FC alias Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​SAN_​FC_​ALIAS FC alias on which selected operation performed.​ FCAlias​Identity

Update HSRP

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
HSRP Group Number HSRP Group Number.​ HSRPGroup​Number​Identity Y
Enabled HSRPV2 Check the box to enable hsrp version 2.​ By default, the check box is unchecked.​ Boolean
Authentication Text Enter the authentication text.​ The text must be no more than 8 characters long.​ password
Preempt Check the box to enable preempt.​ By default, the check box is checked.​ Boolean
Min Preempt Delay Time Min Preempt Delay Time.​ gen_​text_​input
Priority Priority.​ gen_​text_​input
Lower Threshhold Time Lower Threshhold Time.​ gen_​text_​input
Upper Threshhold Time Upper Threshhold Time.​ gen_​text_​input
Hello Interval Hello Interval.​ gen_​text_​input
Hold Time Interval Hold Time Interval.​ gen_​text_​input
Virtual IP Address Virtual IP Address in Format i.​i.​i.​i.​ ipaddress
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​INTERFACE_​NAME The Interface Name set on the device.​ gen_​text_​input
OUTPUT_​GROUP_​NUMBER The HSRP Group Number set on the device.​ gen_​text_​input
OUTPUT_​HSRP_​GROUP_​NUMBER_​IDENTITY The HSRP Group Number Identity.​ HSRPGroup​Number​Identity
OUTPUT_​AUTHENTICATION_​TEXT The Authentication Text set on the device.​ password
OUTPUT_​PRIORITY The Priority set on the device.​ gen_​text_​input
OUTPUT_​MIN_​PREEMPT_​DELAY_​TIME The Min Preempt Delay Time set on the device.​ gen_​text_​input
OUTPUT_​LOWER_​THRESHHOLD_​PERIOD The Lower Threshhold Period set on the device.​ gen_​text_​input
OUTPUT_​UPPER_​THRESHHOLD_​PERIOD The Upper Threshhold Period set on the device.​ gen_​text_​input
OUTPUT_​HELLO_​INTERVAL The Hello Interval set on the device.​ gen_​text_​input
OUTPUT_​HOLD_​INTERVAL The Hold Interval set on the device.​ gen_​text_​input
OUTPUT_​VIRTUAL_​IP The Virtual IP Address set on the device.​ gen_​text_​input

Update Ip Pool Template

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
Select IP Pool Template Name Choose an IP pool template to update Infra​Network​IPPool​Template​Identity Y
IP Address From Range Enter the IP address start as A.​B.​C.​D.​ For example: 2.​3.​4.​5.​ ipaddress Y
IP Address To Range Enter the IP address end as A.​B.​C.​D.​ For example: 4.​4.​5.​2.​ ipaddress Y
Network Address Enter the network IP address as A.​B.​C.​D.​ For example: 182.​4.​3.​22.​ ipaddress Y
Network Subnet Mask Enter the network subnet mask as A.​B.​C.​D.​ For example: 255.​255.​1.​1.​ ipaddress Y
Description Enter the IP pool template description gen_​text_​input
Default Router Enter the Gateway for IP pool template as A.​B.​C.​D.​ For example: 172.​23.​23.​44.​ ipaddress
DNS Server Enter the DNS server IP as A.​B.​C.​D.​ For example: 12.​3.​4.​5.​ ipaddress
DNS Suffix Enter the DNS suffix gen_​text_​input
Netbios Name Server Enter the Net​Bios name server IP as A.​B.​C.​D.​ For example:12.​3.​4.​5.​ ipaddress
Select Netbios Type Choose a Net​Bios state: enabled or disabled.​ By default state is disabled.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​IP_​POOL_​TEMPLATE IP Pool Template gen_​text_​input
HYPERV_​N1K_​IP_​POOL_​TEMPLATE_​IDENTITY IP Pool Template Identity Infra​Network​IPPool​Template​Identity

Update N1K HyperV Port Profile

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Port Profile Name Choose a port profile infra_​network_​port_​profile_​name Y
Description Enter the port profile description gen_​text_​input
Port Profile Type By default port profile type is ethernet.​ This field is not editable.​ networking_​device_​port_​profile_​type Y
Channel Group Mode Choose a channel group mode: Sub-Group or MAC-Pinning.​ By default Sub-Group is selected.​ gen_​text_​input
Sub Group Type Choose a sub group type: CDP or Manual.​ By default CDP is selected.​ gen_​text_​input
Publish Port Profile Select to Publish VEthernet Port Profile gen_​text_​input
Publish Port Profile Name Select to Publish VEthernet Port Profile Name gen_​text_​input
Mode Select Mode Type as Trunk or Access networking_​device_​port_​profile_​mode
Enable VXLAN Capability Enable / Disable the VXLAN Capability.​ Boolean
Access VLAN Select VLAN vlan​ID Y
Action Select action to add or remove VLANs from port profile gen_​text_​input
System VLAN Check this to add the selected VLANs to system VLANs.​ By default this field is unchecked.​
Allowed VLANs Select list of VLAN to be allowed in trunk mode vlan​ID Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
VLAN_​ID_​LIST VLAN IDs on which the selected operation was performed vlan​ID
HYPERV_​PORT_​PROFILE_​IDENTITY Hyper​V Port Profile Identity hyperv​Vna​Port​Profile​Identity

Update N7K VDC

Summary
Update the VDC for a Nexus 7000 device.
Description
This task updates a virtual device context (VDC) for a Nexus 7000 device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
VDC Name Select a VDC name nxos​VDCIdentity Y
Module Type Enter one or more of these module types, separated with commas: f1, f2, f2e, m1, m1x1 or m2x1.​ For example: f2e, m2x1.​ If this field is left blank, the default value is used.​ gen_​text_​input
HA Policy Check this option to enable the high availability policy.​ By default, this field is unchecked.​
Select Type Enter one of the listed HA types: dual-sup or single-sup.​ If this field is left blank, the value defaults to dual-sup.​ gen_​text_​input Y
Select HA Policy Action Enter an HA policy action: bringdown, reload or restart.​ If this field is left blank, the value defaults to bringdown.​ gen_​text_​input Y
VDC Template Name Enter the VDC template name.​ If no template is specified, the default resource template is used.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Update Network Segment

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Network Segment Choose a network segment to update hyperv_​n1k_​network_​segment_​identity Y
Network Segment Description Enter the network segment description gen_​text_​input
Network Segment Type This field is not-editable.​ Type is set based on the network segment selected.​ gen_​text_​input
IP Address / Subnet Enter the IP address/Subnet in the format X.​X.​X.​X/Y.​ For example: 172.​23.​24.​1/32.​ gen_​text_​input
IP Pool Template Name Choose an IP pool template Infra​Network​IPPool​Template​Identity
Network Segment Pool Name Choose a network segment pool hyperv_​n1k_​network_​segment_​pool_​identity
Tenant VRF Name Choose a tenant VRF hyperv_​n1k_​tenant_​vrf_​identity
System Network Segment Check this option to enable the system network segment.​ By default this field is unchecked.​
Type Choose a segment type: VLAN, VXLAN or HNV.​ VLAN is selected by default.​ gen_​text_​input Y
Vlan Enter the VLAN ID between 1 and 4096.​ vlan​ID
Segement ID Enter the bridge domain ID between 4097 and 16777215.​ gen_​text_​input
Private VLAN Type Choose a private VLAN type: Primary or Secondary.​ By default primary is selected.​ gen_​text_​input
Secondary VLAN Type Choose a secondary VLAN type: Host or Promiscuous.​ By default host is selected.​ gen_​text_​input
Host Type Choose a host type: Community or Isolated.​ By default Community is selected.​ gen_​text_​input
Primary VLAN Enter the primary VLAN details vlan​ID
Secondary VLAN Enter the secondary VLAN details vlan​ID
Publish Network Segment Check this to publish network segment.​ By default this field is unchecked.​ gen_​text_​input
Publish Network Segment Name Enter the publish network segment name gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​NETWORK_​SEGMENT Network Segment gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​IDENTITY Network Segment Identity hyperv_​n1k_​network_​segment_​identity
HYPERV_​N1K_​IP_​POOL_​TEMPLATE IP Pool Template gen_​text_​input
HYPERV_​N1K_​IP_​POOL_​TEMPLATE_​IDENTITY IP Pool Template Identity Infra​Network​IPPool​Template​Identity
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL Network Segment Pool gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL_​IDENTITY Network Segment Pool Identity hyperv_​n1k_​network_​segment_​pool_​identity
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​DEVICE_​VLAN_​IDENTITY Identity for device vlan Infra​Network​VLANIdentity
PRIMARY_​VLAN_​ID Primary VLAN ID on which the selected operation was performed vlan​ID
SECONDARY_​VLAN_​ID Secondary VLAN ID on which the selected operation was performed vlan​ID
HYPERV_​LOGICAL_​NETWORK_​IDENTITY Hyper​V Logical Network Identity hyperv​Logical​Network​Identity
HYPERV_​LOGICALNETWORK_​DEF_​IDENTITY Hyper​V Network Segment Pool Identity hyperv​Logical​Network​Def​Identity
HYPERV_​IP_​POOL_​IDENTITY Hyper​V IP Pool Template Identity hyperv​Ip​Pool​Identity
HYPERV_​VM_​NETWORK_​IDENTITY Hyper​V VM Network Identity hyperv​VMNetwork​Identity

Update Network Segment Pool

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Network Segment Pool Name Choose a network segment Pool hyperv_​n1k_​network_​segment_​pool_​identity Y
Logical Network Name Choose a Logical network hyperv_​n1k_​logical_​network_​identity
Segment Type Choose a segment type: VLAN, VXLAN or HNV.​ VLAN is selected by default.​ VXLAN and HNV Segment Types Supported Version: Nexus1000v Hyper​V 5.​2(1)SM3(1.​1) or later.​ gen_​text_​input
Multicast IP Enter the multicast ip in the format x.​x.​x.​x.​ For example: 239.​1.​1.​1.​ ipaddress
Intra Port Communication Check this for intra port communication.​ By default this field is unchecked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
HYPERV_​N1K_​LOGICALNETWORK Logical Network gen_​text_​input
HYPERV_​N1K_​LOGICALNETWORK_​IDENTITY Logical Network Identity hyperv_​n1k_​logical_​network_​identity
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL Network Segment Pool gen_​text_​input
HYPERV_​N1K_​NETWORK_​SEGMENT_​POOL_​IDENTITY Network Segment Pool Identity hyperv_​n1k_​network_​segment_​pool_​identity

Update Port Profile

Summary
Add or remove one or more VLANs from a port profile on a Nexus device.
Description
This task updates and enables a port profile on a Nexus switch. VLANs can be added or removed from the port profile. If the port profile is in access mode, the task can change the access VLAN. If the port profile is in trunk mode, the task can add or remove VLANs to or from the trunk.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device networking_​device Y
Port Profile Name Select port profile name.​ infra_​network_​port_​profile_​name Y
Description Enter description for this port profile gen_​text_​input
Type Select the type of port profile networking_​device_​port_​profile_​type
Mode Select the mode of port profile networking_​device_​port_​profile_​mode
Enable VXLAN Capability Enable / Disable the VXLAN Capability.​
IP address IP address in format i.​i.​i.​i ipaddress
IP network mask IP network mask in format m.​m.​m.​m ipaddress
IP next-hop address IP next-hop address in format i.​i.​i.​i ipaddress
Access VLAN Select VLAN vlan​ID Y
Action Select action to add or remove VLANs from port profile gen_​text_​input
Allowed VLANs Allowed VLANs vlan​ID Y
Add to System VLAN Select this option to add the selected VLANs to System VLAN
Primary VLAN ID Primary VLAN vlan​ID Y
Secondary VLAN ID Secondary VLAN IDs to associate vlan​ID Y
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​PROFILE_​NAME Name of the port profile on which the selected operation was performed infra_​network_​port_​profile_​name
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​SGT_​IDENTITY SGT Identity.​ security​Grouptag​ID
PORT_​PROFILE_​TYPE Name of the port profile type networking_​device_​port_​profile_​type
PORT_​PROFILE_​MODE Name of the port profile mode networking_​device_​port_​profile_​mode

Update SXP Connection Peer

Summary
Description
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose a networking device networking_​device Y
Enable Device Tracking Check this option to enable device tracking.​ By default, this field is unchecked
Delete Hold Timer Period Enter the delete hold timer period within the range (0-64000) gen_​text_​input
Enable SXP Check this option to enable SXP.​ By default, this field is checked
Default Source IP Address Enter the default SXP connection peer source IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4 ipaddress
Default Password Enter the default password password
Source IP Address Enter the SXP connection peer source IP address in format i.​i.​i.​i.​ For example: 1.​2.​3.​4 ipaddress
Password Option Choose one of the listed password options: default, None or Required.​ If this field is left blank, the value defaults to None.​ gen_​text_​input Y
Required Password Enter the Required password password Y
VRF Enter the VRF name gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity
OUTPUT_​ISDEVICE_​TRACKING_​ENABLE The Device Tracking enabled on the device.​ gen_​text_​input
OUTPUT_​DELETE_​HOLD_​PERIOD The Delete Hold Timer set on the device.​ gen_​text_​input
OUTPUT_​ISSXP_​ENABLE The SXP is enabled on the device.​ gen_​text_​input
OUTPUT_​DEFAULT_​SOURCE_​IP The Default Source IP created on the device.​ ipaddress
OUTPUT_​DEFAULT_​PASSWORD The Default Password created on the device.​ password
OUTPUT_​PEER_​IP The Peer IP created on device.​ ipaddress
OUTPUT_​SXP_​CONNECTION_​PEER_​IDENTITY The SXP Connection Peer Identity.​ Sxp​Connection​Peer​Identity
OUTPUT_​SOURCE_​IP The Source IP created on the device.​ ipaddress
OUTPUT_​PASSWORD_​OPTION The Password Option created on the device.​ gen_​text_​input
OUTPUT_​REQUIRED_​PASSWORD The Required Password created on the device.​ password
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input

Update Trunk

Summary
Add or remove allowed VLANs on a trunk.
Description
This task adds or removes one or more VLANs to or from the list of allowed VLANs on a trunk.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a networking device.​ networking_​device Y
Select Port Select a port on which to update trunk.​ Infra​Network​Interface​Identity Y
Action Choose an action, either add or remove VLANs from the port profile.​ The default is add.​ gen_​text_​input
Allowed VLANs Choose one or more VLAN to be allowed in trunk mode.​ vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
ALLOWED_​VLAN_​IDS Allowed VLAN IDsf on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​NEXUS_​VDC The VDC created on the Nexus 7000 devices.​ nxos​VDCIdentity

Update Uplink Network

Update VRF

Summary
Update a VRF.
Description
This task updates a VPN routing and forwarding (VRF).
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a device networking_​device Y
VRF Name Choose a VRF context to update networking_​vrf_​identity Y
Add/Delete Route​IP and Gateway Check this option to add or delete a route IP and gateway.​ By default this field is unchecked.​
Route Enter a Route as A.​B.​C.​D/LEN.​ For example: 13.​2.​3.​1/32.​ gen_​text_​input
Gateway Enter a Gateway IP as A.​B.​C.​D.​ For example: 142.​23.​1.​1.​ ipaddress
Route & Gateway Select a route and gateway to delete gen_​text_​input
Domain Name Enter the domain name gen_​text_​input
DNS Servers Enter one or more DNS servers separated with commas or spaces.​ No more than 6 DNS servers are allowed for one VRF.​ For example: cisco.​com,VMware.​org.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​VRF The VRF created on the device.​ gen_​text_​input
OUTPUT_​VRF_​IDENTITY The VRF Identity created on the device.​ gen_​text_​input
OUTPUT_​DOMAIN_​NAME The VRF created on the device.​ gen_​text_​input

Update VXLAN

Summary
Update a VXLAN for a Nexus 1000V.
Description
This task updates a VXLAN for a Nexus 1000V device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Choose the networking device networking_​device Y
Bridge Name Select the domain name for the VXLAN bridge.​ gen_​text_​input Y
VXLAN Id Provide a VXLAN ID in the range 4096 to 16000000 gen_​text_​input Y
Mode Unicast Check this option to set the unicast mode for the VXLAN.​ By default, this field is checked.​
VXLAN Group IP Address Provide the multicast IP address for the VXLAN in the format i.​i.​i.​i.​ For example: 224.​0.​0.​5.​ ipaddress Y
Distribution learning MAC Check this option to set floodless learning using the MAC.​ By default, this field is checked.​
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
VXLAN_​ID VXLAN ID on which the selected operation was performed vlan​ID
VXLAN_​DOAMIN_​NAME VXLAN Domain Name on which the selected operation was performed gen_​text_​input