Service Profile Type |
Choose a service profile type for SAN zoning |
|
|
Service Profile |
Choose a service profile |
ucsServiceProfileIdentity |
Y |
Global Service Profile |
Choose a global service profile |
UCS_CENTRAL_SERVICE_PROFILE_IDENTITY |
Y |
CIMC Server |
Choose a CIMC server IP |
cimcServerIdentity |
Y |
Configure One to One zones |
Check this to configure one to one zones |
|
|
Activate Zone Set |
Check this to activate the zone set after creation |
|
|
Commit Zone |
Check this to commit the zone set after creation |
|
|
Device Alias |
Check this to enable device alias |
|
|
Prefer SmartZoning if device supports |
Check this to enable smart zoning |
|
|
Select vHBA |
Choose the vHBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx. For example: 20:00:00:25:B5:00:0A:1F. |
gen_text_input |
Y |
Device Alias Fab A vHBA |
Enter a device alias name for the vHBA - fabric A |
gen_text_input |
|
VSAN ID |
This is a non-editable field. It displays the VSAN associated with the vHBA. |
gen_text_input |
|
Zone Name |
Enter the zone name for configuration of fabric A |
gen_text_input |
|
Storage Account Type |
Choose a storage account type: NetApp, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, XtremIO/EMC, VPLEX/IBM
Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller. By default no account type is selected.
|
gen_text_input |
|
Storage Account Name (Primary) |
Choose a primary storage account name for fabric A |
gen_text_input |
|
Storage FC Adapter (Primary) |
Select a primary storage FC adapter for fabric A |
GENERIC_FC_ADAPTER_LIST |
Y |
Device Alias FC Adapter |
Enter the device alias name for the primary FC adapter. If multiple FC adapters are available, the name is used as a prefix. |
gen_text_input |
|
Configure Secondary Head |
Check this to configure secondary head for fabric A. By default this field is unchecked. |
|
|
Storage Account Name (Secondary) |
Choose a secondary storage account name for fabric A |
gen_text_input |
|
Storage FC Adapter (Secondary) |
Select a secondary storage FC adapter for fabric A |
GENERIC_FC_ADAPTER_LIST |
Y |
Device Alias FC Adapter |
Enter the device alias name for secondary FC adapter for fabric A. If multiple FC adapters are available, the name is used
as a prefix.
|
gen_text_input |
|
Secondary Zone Name |
Enter the secondary zone name to configure for fabric A |
gen_text_input |
|
Select Device |
Select device for Fabric A configuration |
infraNetCiscoSanDeviceIdentity |
Y |
Select Source Port |
Choose the source port for fabric A. |
gen_text_input |
Y |
Select Mapping VSAN |
Choose a VSAN ID for fabric A between 2 and 4093 |
gen_text_input |
Y |
Configure Fabric B |
Check this to configure fabric B. By default this field is unchecked. |
Boolean |
|
Select vHBA |
Choose the vHBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx. For example: 20:00:00:25:B5:00:0A:1F. |
gen_text_input |
Y |
Device Alias Fab B vHBA |
Enter the device alias name for the vHBA - fabric B |
gen_text_input |
|
VSAN ID |
This is a non-editable field. It displays the VSAN associated with the vHBA - fabric B. |
gen_text_input |
|
Zone Name |
Enter the zone name for configuring fabric B |
gen_text_input |
|
Storage Account Type |
Choose a storage account type for fabric B: NetApp, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, XtremIO/EMC,
VPLEX/IBM Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller. By default none is selected.
|
gen_text_input |
|
Storage Account Name (Primary) |
Choose a primary storage account name for fabric B |
gen_text_input |
|
Storage FC Adapter (Primary) |
Select a primary storage FC adapter for fabric B |
GENERIC_FC_ADAPTER_LIST |
Y |
Device Alias FC Adapter |
Enter the device alias name for the primary FC adapter for fabric B. If multiple FC adapters are available, the name is used
as a prefix.
|
gen_text_input |
|
Configure Secondary Head |
Check this to configure the secondary head of fabric B. By default this field is unchecked. |
|
|
Storage Account Name (Secondary) |
Choose a secondary storage account name for fabric B |
gen_text_input |
Y |
Storage FC Adapter (Secondary) |
Select a secondary storage FC adapter for fabric B |
GENERIC_FC_ADAPTER_LIST |
Y |
Device Alias FC Adapter |
Enter the device alias name for secondary FC adapter for fabric B. If multiple FC adapters are available, the name is used
as a prefix.
|
gen_text_input |
|
Zone Name |
Enter the secondary zone name to configure for the fabric B |
gen_text_input |
|
Select Device |
Select device for Fabric B configuration |
infraNetCiscoSanDeviceIdentity |
Y |
Select Source Port |
Select the source port for fabric B |
gen_text_input |
Y |
Select Mapping VSAN |
Select a VSAN ID for fabric B between 2 and 4093 |
gen_text_input |
Y |
Copy Running configuration to Startup configuration |
Check this option to copy the running configuration to the startup configuration. By default, this field is checked. |
|
|