Brocade Network Tasks

This chapter contains the following sections:

Brocade Assign Port to Port Channel

Summary
Assign a Brocade NOS switch Ethernet port to a port channel.
Description
This task makes an Ethernet port a member of a port channel on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Port Channel Select Port Channel Infra​Network​Brocade​Port​Channel​Identity Y
Select Port Choose a port to be assigned to the port channel.​ For example: Ten​Gigabit​Ethernet 1/0/20, Forty​Gigabit​Ethernet 1/0/52.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​NET_​DEVICE_​BROCADE_​PORT_​CHANNEL_​IDENTITY Identity for Brocade port channel.​ Infra​Network​Brocade​Port​Channel​Identity

Brocade Copy Running To Startup Configuration

Summary
Copy a running configuration to a startup configuration.
Description
This task copies the running configuration of a Brocade Network OS (NOS) device to the startup configuration. Making this task the last task of a network configuration workflow makes the changes permanent to the device flash.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a Brocade device Infra​Network​Brocade​NOSDevice​Identity Y
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity

Brocade Switch Port Action

Summary
Configure a switch port to UP or DOWN on a Brocade NOS device.
Description
This task configures the administrative UP or DOWN state on a switch port on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Switch Port Select the switch port to act on Infra​Network​Brocade​Interface​Identity Y
Switch Port Action Choose the switch port action type: Up or Down.​ If this field is left blank, the default value is used.​ Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​NET_​DEVICE_​BROCADE_​INTERFACE_​IDENTITY Identity for Brocade interface.​ Infra​Network​Brocade​Interface​Identity

Configure Brocade Trunk

Summary
Configure a trunk on an Ethernet or port channel interface.
Description
This task configures a trunk on an ethernet or port channel interface on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a Brocade device Infra​Network​Brocade​NOSDevice​Identity Y
Select Port Choose a port to configure the trunk For example: Ten​Gigabit​Ethernet 1/0/20, Forty​Gigabit​Ethernet 1/0/52, port-channel 25.​ gen_​text_​input Y
Native VLAN ID Select a native VLAN ID vlan​ID
Allowed VLANs Provide one or more VLANs between 0 and 4094, separated with commas, to be allowed in trunk mode.​ gen_​text_​input Y
Type Choose any of the listed port types for spanning tree protocol: edgeport, autoedge or portfast.​ If not specified, the value defaults to edgeport.​ gen_​text_​input
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
No Outputs

Configure SAN Zoning

Summary
Configure SAN zones and associate zones with zonesets.
Description
This task configures zones with UCS vHBA and NetApp Fiber Channel adapters as members and then associate the zones with the active zoneset. If there is no active zoneset available on the switch, the task creates a new zoneset and actives it.
Inputs
Input Description Mappable To Type Mandatory
Activate Zone Set Check this option to activate the zone set after creation.​ By default, this field is checked.​
Commit Zone Check this option to commit the SAN zone after creation.​ By default, this field is unchecked.​
Server Account Type Choose the server type, UCS or CIMC.​ The default is UCS.​ gen_​text_​input
Service Profile Select a service profile.​ ucs​Service​Profile​Identity Y
CIMC Server Select a CIMC server.​ cimc​Server​Identity Y
Select v​HBA Choose a v​HBA for fabric-A configuration.​ For example: fabric_​A [10:20:ab:d3:78:h6:8k:99].​ gen_​text_​input Y
Device Alias Fab A v​HBA Enter a device alias name for the v​HBA.​ If the selected v​HBA and WWPN exist on the device, then the device alias is not created.​ gen_​text_​input
VLAN ID Enter the VLAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ vlan​ID
VSAN ID Provide a VSAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ gen_​text_​input
Zone Name Enter a zone A name.​ gen_​text_​input
Net​App Account Name (Primary) Choose a primary Net​App account for fabric A configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Primary) Choose a primary Net​App fiber channel adapter for fabric A configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ gen_​text_​input Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapters are available.​ gen_​text_​input
Configure Secondary Head Check this option to configure a secondary head.​ Default value is unchecked.​
Net​App Account Name (Secondary) Choose a secondary Net​App account for fabric A configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Secondary) Choose a primary Net​App fiber channel adapter for fabric A configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ gen_​text_​input Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapter is available.​ gen_​text_​input
Select Device Select device for Fabric A configuration gen_​text_​input Y
Select Source Port Choose a source port to which the server is connected.​ For example: ethernet1/1 or gigabitethernet2/4.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN to map the VLAN.​ Valid range is 2 to 4094.​ gen_​text_​input Y
Configure Fabric B Check this option to configure zones for fabric B.​ By default, this field is unchecked.​
Select v​HBA Choose a v​HBA for fabric B configuration.​ gen_​text_​input Y
Device Alias Fab B v​HBA Provide a device alias name for the fabric B v​HBA.​ If the provided v​HBA and WWPN exist in the device, the device alias is not created.​ gen_​text_​input
VLAN ID Provide the VLAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ vlan​ID
VSAN ID Provide the VSAN ID associated with the selected v​HBA.​ Valid range is 2 to 4094.​ gen_​text_​input
Zone Name Enter the zone B name.​ gen_​text_​input
Net​App Account Name (Primary) Choose a primary Net​App account for fabric B configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Primary) Choose a primary Net​App fiber channel adapter for fabric B configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ Cluster​Filer​Identity Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as prefix if multiple FC adapter is available.​ gen_​text_​input
Configure Secondary Head Check this option to configure a secondary head.​ Default value is unchecked.​
Net​App Account Name (Secondary) Choose a secondary Net​App account for fabric B configuration.​ Cluster​Filer​Identity Y
Net​App FC Adapter (Secondary) Choose a secondary Net​App fiber channel adapter for fabric B configuration.​ For example: Eng_​fcp [Current port = 0e\WWPN=1:a:23:fs:jk:89:76:kk:ll\Operation Status=down].​ Cluster​Filer​Identity Y
Device Alias FC Adapter Enter a device alias name for the FC adapter.​ This is used as a prefix if multiple FC adapters are available.​ gen_​text_​input
Select Device Select a networking device for fabric B configuration in the formate datacenter@device_​ip.​ For example: test​Pod@10.​23.​210.​20.​ gen_​text_​input Y
Select Source Port Choose a source port to which the server is connected.​ For example: ethernet1/1 or gigabitethernet2/4.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN to map the VLAN.​ Valid range is 2 to 4094.​ gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
FABRIC_​A_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric A gen_​text_​input
FABRIC_​A_​ZONE_​NAME Name of the zone that was created for fabric A gen_​text_​input
FABRIC_​A_​DEVICE_​IP Switch IP Address (Fabric A) networking_​device
FABRIC_​A_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
SAN_​ZONE_​A_​IDENTITY Identity for SAN Zone A gen_​text_​input
FABRIC_​A_​VDC_​NAME VDC Name (Fabric A) nxos​VDCIdentity
FABRIC_​B_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric B gen_​text_​input
FABRIC_​B_​ZONE_​NAME Name of the zone that was created for fabric B gen_​text_​input
FABRIC_​B_​DEVICE_​IP Switch IP Address (Fabric B) networking_​device
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
FABRIC_​B_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
SAN_​ZONE_​B_​IDENTITY Identity for SAN Zone B gen_​text_​input
FABRIC_​B_​VDC_​NAME VDC Name (Fabric B) nxos​VDCIdentity

Create Brocade Port Channel

Summary
Create a port channel on a Brocade NOS switch.
Description
This task creates and adds a description to a port channel on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select Device Infra​Network​Brocade​NOSDevice​Identity Y
Port Channel Number Provide a port channel number within the range 1 to 6144.​ gen_​text_​input Y
Description Provide a description for the port channel gen_​text_​input
Copy Running configuration to Startup configuration Select this option to copy running configuration to startup configuration
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​CHANNEL_​ID Port channel number gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​NET_​DEVICE_​BROCADE_​PORT_​CHANNEL_​IDENTITY Identity for Brocade port channel.​ Infra​Network​Brocade​Port​Channel​Identity

Create Brocade VLAN

Summary
Create a VLAN on a Brocade NOS device.
Description
This task creates a Virtual Local Area Network (VLAN) on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a Brocade device Infra​Network​Brocade​NOSDevice​Identity Y
VLAN ID Provide a VLAN ID between 1 and 3583 vlan​ID Y
VLAN Descrption Provide a VLAN description gen_​text_​input
No Shutdown Check this option to disable shutdown.​ By default, this field is unchecked.​ Boolean
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
VLAN_​NAME VLAN Name on which the selected operation was performed gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​DEVICE_​BROCADE_​VLAN_​IDENTITY Identity for Brocade VLAN Infra​Network​Brocade​VLANIdentity

Delete Brocade Port Channel

Summary
Delete a port channel on a Brocade NOS device.
Description
This task deletes a port channel on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Port Channel Select Port Channel Infra​Network​Brocade​Port​Channel​Identity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
PORT_​CHANNEL_​ID Port channel number gen_​text_​input
PORT_​CHANNEL_​NAME Port channel name gen_​text_​input
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​NET_​DEVICE_​BROCADE_​PORT_​CHANNEL_​IDENTITY Identity for Brocade port channel.​ Infra​Network​Brocade​Port​Channel​Identity

Delete Brocade VLAN

Summary
Delete a VLAN on a Brocade NOS device.
Description
This task deletes a virtual LAN (VLAN) on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
VLAN Select a Brocade VLAN to be deleted Infra​Network​Brocade​VLANIdentity Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
VLAN_​ID VLAN ID on which the selected operation was performed vlan​ID
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device
OUTPUT_​BROCADE_​NOS_​DEVICE_​IDENTITY Identity for Brocade NOS device.​ Infra​Network​Brocade​NOSDevice​Identity
OUTPUT_​DEVICE_​BROCADE_​VLAN_​IDENTITY Identity for Brocade VLAN Infra​Network​Brocade​VLANIdentity

Generic Configure SAN Zoning

Summary
Configure SAN zoning on a UCS CIMC or Nexus device.
Description
This task creates generic SAN zoning on a compute or network device.
Inputs
Input Description Mappable To Type Mandatory
Service Profile Type Choose a service profile type for SAN zoning
Service Profile Choose a service profile ucs​Service​Profile​Identity Y
Global Service Profile Choose a global service profile UCS_​CENTRAL_​SERVICE_​PROFILE_​IDENTITY Y
CIMC Server Choose a CIMC server IP cimc​Server​Identity Y
Configure One to One zones Check this to configure one to one zones
Activate Zone Set Check this to activate the zone set after creation
Commit Zone Check this to commit the zone set after creation
Device Alias Check this to enable device alias
Prefer Smart​Zoning if device supports Check this to enable smart zoning
Select v​HBA Choose the v​HBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx.​ For example: 20:00:00:25:B5:00:0A:1F.​ gen_​text_​input Y
Device Alias Fab A v​HBA Enter a device alias name for the v​HBA - fabric A gen_​text_​input
VSAN ID This is a non-editable field.​ It displays the VSAN associated with the v​HBA.​ gen_​text_​input
Zone Name Enter the zone name for configuration of fabric A gen_​text_​input
Storage Account Type Choose a storage account type: Net​App, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, Xtrem​IO/EMC, VPLEX/IBM Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller.​ By default no account type is selected.​ gen_​text_​input
Storage Account Name (Primary) Choose a primary storage account name for fabric A gen_​text_​input
Storage FC Adapter (Primary) Select a primary storage FC adapter for fabric A GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for the primary FC adapter.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Configure Secondary Head Check this to configure secondary head for fabric A.​ By default this field is unchecked.​
Storage Account Name (Secondary) Choose a secondary storage account name for fabric A gen_​text_​input
Storage FC Adapter (Secondary) Select a secondary storage FC adapter for fabric A GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for secondary FC adapter for fabric A.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Secondary Zone Name Enter the secondary zone name to configure for fabric A gen_​text_​input
Select Device Select device for Fabric A configuration infra​Net​Cisco​San​Device​Identity Y
Select Source Port Choose the source port for fabric A.​ gen_​text_​input Y
Select Mapping VSAN Choose a VSAN ID for fabric A between 2 and 4093 gen_​text_​input Y
Configure Fabric B Check this to configure fabric B.​ By default this field is unchecked.​ Boolean
Select v​HBA Choose the v​HBA for fabric A in this format: xx:xx:xx:xx:xx:xx:xx:xx.​ For example: 20:00:00:25:B5:00:0A:1F.​ gen_​text_​input Y
Device Alias Fab B v​HBA Enter the device alias name for the v​HBA - fabric B gen_​text_​input
VSAN ID This is a non-editable field.​ It displays the VSAN associated with the v​HBA - fabric B.​ gen_​text_​input
Zone Name Enter the zone name for configuring fabric B gen_​text_​input
Storage Account Type Choose a storage account type for fabric B: Net​App, ONTAP/EMC VNX, Block/EMC VNX, Unified/EMC, VNXe/EMC, VMAX/EMC, Xtrem​IO/EMC, VPLEX/IBM Storwize, V7000 Unified/IBM storage Array/IBM Storwize V7000/IBM SAN Volume controller.​ By default none is selected.​ gen_​text_​input
Storage Account Name (Primary) Choose a primary storage account name for fabric B gen_​text_​input
Storage FC Adapter (Primary) Select a primary storage FC adapter for fabric B GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for the primary FC adapter for fabric B.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Configure Secondary Head Check this to configure the secondary head of fabric B.​ By default this field is unchecked.​
Storage Account Name (Secondary) Choose a secondary storage account name for fabric B gen_​text_​input Y
Storage FC Adapter (Secondary) Select a secondary storage FC adapter for fabric B GENERIC_​FC_​ADAPTER_​LIST Y
Device Alias FC Adapter Enter the device alias name for secondary FC adapter for fabric B.​ If multiple FC adapters are available, the name is used as a prefix.​ gen_​text_​input
Zone Name Enter the secondary zone name to configure for the fabric B gen_​text_​input
Select Device Select device for Fabric B configuration infra​Net​Cisco​San​Device​Identity Y
Select Source Port Select the source port for fabric B gen_​text_​input Y
Select Mapping VSAN Select a VSAN ID for fabric B between 2 and 4093 gen_​text_​input Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
FABRIC_​A_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​1_​NAME Name of the zone1 that was created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​2_​NAME Name of the zone2 that was created for fabric A gen_​text_​input
FABRIC_​A_​DEVICE_​IP Switch IP Address (Fabric A) networking_​device
FABRIC_​A_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​1_​IDENTITY Identity for SAN Zone 1 created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​ZONE_​2_​IDENTITY Identity for SAN Zone 2 created for fabric A gen_​text_​input
FABRIC_​B_​ZONESET_​NAME Name of the zoneset on which the selected operation was performed for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​1_​NAME Name of the zone1 that was created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​2_​NAME Name of the zone2 that was created for fabric B gen_​text_​input
FABRIC_​B_​DEVICE_​IP Switch IP Address (Fabric B) networking_​device
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
FABRIC_​B_​VSAN_​ID VSAN ID on which the selected operation was performed gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​1_​IDENTITY Identity for SAN Zone 1 created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​ZONE_​2_​IDENTITY Identity for SAN Zone 2 created for fabric B gen_​text_​input
OUTPUT_​FAB_​A_​PRIMARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 1 created for fabric A gen_​text_​input
OUTPUT_​FAB_​A_​SECONDARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 2 created for fabric A gen_​text_​input
OUTPUT_​FAB_​B_​PRIMARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 1 created for fabric B gen_​text_​input
OUTPUT_​FAB_​B_​SECONDARY_​PORT_​LIST_​IDENTITY Port List Identity for SAN Zone 2 created for fabric B gen_​text_​input
FABRIC_​B_​VDC_​NAME VDC Name (Fabric B) nxos​VDCIdentity

Update Brocade Trunk

Summary
Add or remove allowed VLAN(s) on a trunk.
Description
This task edits which VLANs are allowed on a trunk on a Brocade Network OS (NOS) device.
Inputs
Input Description Mappable To Type Mandatory
Select Device Select a Brocade device Infra​Network​Brocade​NOSDevice​Identity Y
Select Port Provide one or more ports, separated with commas, to configure the trunk.​ For example: Ten​Gigabit​Ethernet 1/0/28, Ten​Gigabit​Ethernet 1/0/30.​ gen_​text_​input Y
Action Choose the action type: Add or Remove to add or remove the VLANs from port profile.​ If this field is left blank, the default value is used.​ gen_​text_​input
Select VLANs Choose one or more VLANs for the operation chosen vlan​ID Y
Copy Running configuration to Startup configuration Check this option to copy the running configuration to the startup configuration.​ By default, this field is checked.​
Outputs
Output Description Type
DATACENTER Name of the Datacenter on which the selected operation was performed datacenter​Name
DEVICE_​IP IP address of the device on which the selected operation was performed gen_​text_​input
ALLOWED_​VLAN_​IDS Allowed VLAN IDsf on which the selected operation was performed gen_​text_​input
PORT_​NAME Name of port on which selected operation was performed.​ gen_​text_​input
OUTPUT_​NETWORKING_​DEVICE Network device on which selected operation performed.​ networking_​device