This section explains connection verification in Cisco Optical Site Manager. The connection verification process generates a specific probe signal from the Connection Verification Tunable Laser (CV-TL) located at COM-RX-2.
Cisco Optical Site Manager offers a connection verification process that checks the cabling between the OLT-C line card and passive modules in an NCS 1010 device, helping prevent miscabling during node installation.
The connection verification process generates a specific probe signal from the Connection Verification Tunable Laser (CV-TL) located at COM-RX-2. This probe signal is then detected on the following components:
-
The same OLT-C line card.
-
Passive modules (Mux/Demux panel or breakout panel) connected to the OLT-C line card.
-
A different OLT-C line card or passive module belonging to the same near-end (NE) node.
-
An optical interface (router ports or transponders) connected to the line card.