Use this procedure to provision ODU circuit in Cisco Optical Site Manager. Both unprotected and protected ODU connections or OTNXC circuits that are created in CTC will be available in the Cisco Optical Site Manager.
Use this task to provision odu circuit.
Use this task to provision ODU circuit created through NETCONF client, in the OTNXC mode of the 400G-XP card.
Both unprotected and protected ODU connections or OTNXC circuits that are created in CTC will be available in the Cisco Optical Site Manager. The user interface after the NCS2000 device is upgraded from CTC to Cisco Optical Site Manager and the device sync is completed. The ODU connection data that is displayed in the Cisco Optical Site Manager user interface has the following discrepancies:
-
When ODU connections are discovered, Cisco Optical Site Manager autogenerates the connection name as "device-name/object index" (an integer number) and displays the connection name as Circuit ID.
-
CTC allows creating a protected ODU connection with two trunk ODU sources and one client ODU destination. But Cisco Optical Site Manager considers this protected ODU connection as invalid. Hence as part of discovery, Cisco Optical Site Manager recreates the protected ODU connection with one source client and two destination trunk ODUs, by swapping.
Use this task to provision ODU circuit created in the OTNXC mode of the 400G-XP card.
Before you begin
Follow these steps to provision odu circuit.
Procedure
-
Click the tabs.
The OTN Circuit tab displays the following information:
|
Field
|
Description
|
|
Circuit ID
|
Unique identifier for the end-to-end circuit.
|
|
Connection label
|
Unique identifier for ODU connections.
|
|
Bandwidth
|
Bandwidth of the circuit. Supported values are ODU4, ODU2, and ODU2e.
|
|
Direction
|
Only bidirectional is supported.
|
|
Source
|
Source ODU port.
|
|
Destination
|
Destination ODU port.
|
|
Protection Reference
|
Displays the protection port.
|
|
Admin State
|
Displays the admin state.
|
|
Service State
|
Displays the service state.
|
|
ILK Usage
|
Displays interlink port usage.
|
-
Click the plus icon to view the Protection Attributes of the circuit.
-
(Optional) Edit the Connection label and the Admin State.
-
(Optional) Click ODU Utilization to view ODU Utilization information.
An ODU utilization window for the 400G-XP-LC card is displayed where you can get information about the availability of each port for ODU circuit creation. All ODU ports are displayed according to the slice configuration that was configured. Each row represents 100G or ODU4 bandwidth. The client ports are listed first followed by the trunk ports. The ports that are already used by the ODU circuit are displayed in green, the ports that are available for circuit creation are displayed in orange and the ports that are not applicable nor configured are displayed in gray.
To view Bandwidth Utilization using the NETCONF client, use the following RPCs:
-
To show the utilization under odu-interface which is part of otn-xc connection:
<action xmlns="urn:ietf:params:xml:ns:yang:1">
<svo xmlns="http://cisco.com/yang/svo">
<odu-connection-commands>
<interface-otnxc-utilization>
<interface-name>1/3/11/1-1</interface-name>
</interface-otnxc-utilization>
</odu-connection-commands>
</svo>
</action>
-
To show card level utilization (You enter the shelf and slot info.):
<action xmlns="urn:ietf:params:xml:ns:yang:1">
<svo xmlns="http://cisco.com/yang/svo">
<odu-connection-commands>
<module-otnxc-utilization>
<uid>1</uid>
<module-id>3</module-id>
</module-otnxc-utilization>
</odu-connection-commands>
</svo>
</action>
-
Click Apply.
You can edit only the Admin State and the Connection label in the Cisco Optical Site Manager user interface. For protected ODU connection, Protection group Name, Revertive mode, and Revertive time can be edited from NETCONF, and web user interface (under the tabs in the shelf view). The other parameters such as Holdoff Timer can be edited only through the NETCONF client.
The provision odu circuit task is complete.