Configuration Guide for Cisco Optical Site Manager, IOS XR Release 26.x.x

PDF

Configuration Guide for Cisco Optical Site Manager, IOS XR Release 26.x.x

Provision FPD upgrade for the ports

Want to summarize with AI?

Log in

Use this procedure to provision FPD upgrade for the ports in Cisco Optical Site Manager. Each trunk port has separate upgrade alarm.


Use this task to provision FPD upgrade for the ports.

When the firmware version on the DCO trunk port is earlier than the NCS 2000 package firmware version, an alarm "FPD-UPG-REQUIRED" is raised on that trunk port in the Alarms tab. Each trunk port has separate upgrade alarm.

You can view the DCO running firmware version and the NCS 2000 package firmware version under the Maintenance > FPD upgrade tabs.

Use this task to upgrade DCO (trunk ports) on the 1.2T-MXP card with the latest firmware released as part of the NCS 2000 software release.

Before you begin

Follow these steps to provision FPD upgrade for the ports.

Procedure

  1. Click the Maintenance > FPD Upgrade tabs.

  2. Click FPD upgrade to perform firmware upgrade for the chosen ports.

    After the firmware upgrade is completed successfully, the "FPD-UPG-REQUIRED" alarm gets cleared in the Alarms tab and you can view the updated running firmware version in the FPD Upgrade table.

    Note

    Traffic affecting DCO upgrade is not supported in Release 12.2.

The provision FPD upgrade for the ports task is complete.