Use this procedure to configure the threshold value for the maximum acceptable differential group delay (DGD) on trunk optics controllers.
Use this task to configure the threshold value for the maximum acceptable differential group delay (DGD) on the trunk optics controllers.
-
The DGD alarm is raised if DGD exceeds this value.
-
The range is 0–18000 (in the units of 0.01 ps).
Procedure
-
Run the controller opticsR/S/I/Pdgd-high-thresholddgd-value command to configure to configure the maximum acceptable DGD.
Example:
This sample configures the minimum acceptable DGD on the controller optics.
RP/0/RP0/CPU0:ios#configure RP/0/RP0/CPU0:ios(config)#controller optics 0/0/0/7 RP/0/RP0/CPU0:ios(config-Optics)#dgd-high-threshold 30 RP/0/RP0/CPU0:ios(config-Optics)#commitThis sample shows the maximum acceptable DGD configured on the controller optics.
RP/0/RP0/CPU0:ios#show controllers optics 0/0/0/7 Fri Nov 12 10:58:50.595 UTC Controller State: Up Transport Admin State: In Service Laser State: On LED State: Yellow Optics Status Optics Type: CIM8 DWDM DWDM carrier Info: C BAND, MSA ITU Channel=61, Frequency=193.10THz, Wavelength=1552.524nm Alarm Status: ------------- Detected Alarms: HIGH-RX-PWR LOW-TX-PWR HIGH-DGD LOS/LOL/Fault Status: Alarm Statistics: ------------- HIGH-RX-PWR = 1 LOW-RX-PWR = 0 HIGH-TX-PWR = 0 LOW-TX-PWR = 1 HIGH-LBC = 0 HIGH-DGD = 6 OOR-CD = 0 OSNR = 0 WVL-OOL = 0 MEA = 0 IMPROPER-REM = 1 TX-POWER-PROV-MISMATCH = 0 Laser Bias Current = 0.0 % Actual TX Power = 0.97 dBm RX Power = -0.53 dBm RX Signal Power = -1.20 dBm Frequency Offset = 63 MHz Performance Monitoring: Enable THRESHOLD VALUES ---------------- Parameter High Alarm Low Alarm High Warning Low Warning ------------------------ ---------- --------- ------------ ----------- Rx Power Threshold(dBm) -2.0 -3.0 0.0 0.0 Tx Power Threshold(dBm) 4.0 2.0 0.0 0.0 LBC Threshold(mA) N/A N/A 0.00 0.00 LBC High Threshold = 55 % Configured Tx Power = 1.00 dBm Configured CD High Threshold = 2400 ps/nm Configured CD lower Threshold = -2400 ps/nm Configured OSNR lower Threshold = 0.40 dB Configured DGD Higher Threshold = 0.30 ps Baud Rate = 63.1394679230 GBd Bits per Symbol = 3.0000000000 bits/symbol Modulation Type: 8QAM Chromatic Dispersion 0 ps/nm Configured CD-MIN -48000 ps/nm CD-MAX 48000 ps/nm Polarization Mode Dispersion = 0.0 ps Second Order Polarization Mode Dispersion = 29.00 ps^2 Optical Signal to Noise Ratio = 36.10 dB SNR = 17.50 dB Polarization Dependent Loss = 0.50 dB Polarization Change Rate = 0.00 rad/s Differential Group Delay = 1.00 ps Transceiver Vendor Details Form Factor : CIM8 Name : CISCO-ACACIA Part Number : 10-3500-01 Rev Number : 01 Serial Number : ACA24480037 PID : CIM8-C-K9 VID : VES1 Date Code(yy/mm/dd) : 23/11/10 Fiber Connector Type: LC Otn Application Code: Not Set Sonet Application Code: Not Set Ethernet Compliance Code: Not set Transceiver Temperature : 46 Celsius AINS Soak : None AINS Timer : 0h, 0m AINS remaining time : 0 seconds -
Run the commit command to apply the changes.