Overview
Environmental specifications for the 32-core, 56-core, and 80-core third-generation Catalyst Center appliances.
Table 1 lists the environmental specifications for the 32-core, 56-core, and 80-core third-generation Catalyst Center appliances.
| Description |
Specification |
| Temperature, Operating |
Dry bulb temperature of 10°C to 35°C (50°F to 95°F) Maximum temperature change of 20°C (36°F) per hour (a temperature change within a specified period of time and not a rate of change) Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Reduce the maximum operating temperature by 1°C (33.8°F) per every 305 meters (1001 feet) of altitude above 900 meters (2953 feet) |
| Temperature, Extended Operating | 5°C to 40°C (41°F to 104°F) with no direct sunlight Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Reduce the maximum operating temperature by 1°C (33.8°F) per every 305 meters (1001 feet) of altitude above 900 meters (2953 feet) |
| Temperature, non-operating (when the server is stored or transported) |
Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F) |
| Humidity (RH), operating |
10% to 90% and 28°C (82.4°F) maximum dew-point temperature, non-condensing environment Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity |
| Humidity (RH), non-operating (when the server is stored or transported) |
5% to 93% relative humidity, non-condensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range. |
| Altitude, operating |
A maximum elevation of 3050 meters (10,006 feet) |
| Altitude, non-operating (when the server is stored or transported) |
An elevation of 0 to 12,000 meters (39,370 feet) |
| Maximum Operating Duration |
Unlimited |
| Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
| Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |