Cisco Catalyst Center Third-Generation Appliance Installation Guide, Release 3.1.x

PDF

Power supply specifications

Want to summarize with AI?

Log in

Overview

Provides links to the specifications for the Catalyst Center appliance's power supplies.

The specifications for the power supplies provided with the Catalyst Center appliance are listed in these topics. All versions of the third-generation appliance ship with two 2300 W power supplies (Cisco part number UCSC-PSU1-2300W).

Click the appropriate link to view the power supply specifications for your appliance.

Note

32-core and 56-core appliances

Parameter Specification

Input Connector

IEC320 C20

Input Voltage Range (Vrms)

100 to 240

Maximum Allowable Input Voltage Range (Vrms)

90 to 264

Frequency Range (Hz)

50 to 60

Maximum Allowable Frequency Range (Hz)

47 to 63

Maximum Rated Output (W)

2300

Limited to 1200 W when operating at low-line input voltage (100-127 V)

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (Vrms)

100

120

208

230

Nominal Input Current (Arms)

13

11

12

10.8

Maximum Input at Nominal Input Voltage (W)

1338

1330

2490

2480

Maximum Input at Nominal Input Voltage (VA)

1351

1343

2515

2505

Minimum Rated Efficiency (%)

This is the minimum rating required to achieve 80PLUS platinum certification. For certified values, see the test reports published at http://www.80plus.org/.

92

92

93

93

Minimum Rated Power Factor

This is the minimum rating required to achieve 80PLUS platinum certification. For certified values, see the test reports published at http://www.80plus.org/.

0.99

0.99

0.97

0.97

Maximum Inrush Current (A peak)

30

Maximum Inrush Current (ms)

0.2

Minimum Ride-Through Time (ms)

Time output voltage remains within regulation limits at 100% load during input voltage dropout.

12


80-core appliance

Parameter Specification

Input Connector

IEC320 C20

Input Voltage Range (Vrms)

100 to 240

Maximum Allowable Input Voltage Range (Vrms)

90 to 264

Frequency Range (Hz)

50 to 60

Maximum Allowable Frequency Range (Hz)

47 to 63

Maximum Rated Output (W)

2300

Limited to 1200 W when operating at low-line input voltage (100-127 V)

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (Vrms)

100

120

208

230

Nominal Input Current (Arms)

13

11

12

10.8

Maximum Input at Nominal Input Voltage (W)

1338

1330

2490

2480

Maximum Input at Nominal Input Voltage (VA)

1351

1343

2515

2505

Minimum Rated Efficiency (%)

This is the minimum rating required to achieve 80PLUS platinum certification. For certified values, see the test reports published at http://www.80plus.org/.

92

92

93

93

Minimum Rated Power Factor

This is the minimum rating required to achieve 80PLUS platinum certification. For certified values, see the test reports published at http://www.80plus.org/.

0.99

0.99

0.97

0.97

Maximum Inrush Current (A peak)

30

Maximum Inrush Current (ms)

0.2

Minimum Ride-Through Time (ms)

Time output voltage remains within regulation limits at 100% load during input voltage dropout.

12