This topic explains how fault profiles change default fault severities for system, node, slot, and port scopes so that generated faults use the severity values that match your operational requirements.
A fault profile is a user-defined fault configuration that
-
contains one or more fault identifiers with assigned severities,
-
overrides the default severity for matching faults when the profile is applied, and
-
uses precedence from the most specific scope to the least specific scope.
The default fault list captures all the fault types generated by the system and the default severity for each fault type. When no fault profile is defined or applied, the system uses the default severity value.
Fault profile precedence starts at the most specific scope. Port-level profiles have the highest precedence, and system-level profiles have the lowest precedence.
Severity levels
Fault profiles support these severity levels:
-
Critical
-
Major
-
Minor
-
Non-Faulted
-
Non-Reported
Fault profile actions
You can use fault profiles to
-
create or delete a fault profile,
-
add alarms to a fault profile,
-
remove alarms from a fault profile, and
-
change the severity of an alarm in an existing fault profile.