Adding SFP Modules to Step 7TIA

Supported Small Form-Factor Pluggables

This document describes how to add Small Form-Factor Pluggable (SFP) modules to the SIMATIC STEP7 or TIA Portal automation applications to enable these applications to recognize the SFP modules in the PROFINET environment.

The following SFPs are supported for the switch and the fiber ports expansion module and can be added to the STEP 7 or TIA Portal Automation application installed on the supervisor:

  • GLC-T

  • GLC-TE

  • GLC-T-RGD

  • GLC-FE-100FX-RGD

  • GLC-FE-100LX-RGD

  • GLC-SX-MM-RGD

  • GLC-LX-SM-RGD

  • GLC-FE-100FX

  • GLC-FE-100LX

  • GLC-SX-MMD

  • GLC-LH-SMD

  • GLC-SX-MM

  • GLC-LH-SM

Adding SFPs to the Hardware Configuration in SS7/TIA

Follow this procedure to add SFPs to the hardware configuration in STEP7 or TIA.

Before you begin

Install the latest GSD file for your IE switches in STEP7 or TIA (see Configuring the Switch with STEP7/TIA for more information). The GSD file is not backward compatible. Combination ports do not have defaults and must be re-created in STEP7 or TIA with the new GSD file.

Procedure


Step 1

In STEP7 or TIA, open the project containing the Cisco IE switch, and double-click Devices & networks in the Project tree.

Step 2

From the Hardware catalog in the devices and network editor, select the Device Access Point (DAP) name for your switch.

Step 3

Double-click the DAP name to go to Device view tab (see callout 1).

Step 4

Expand the PN-IO row (see callout 2) in Device overview section if the port list is not displayed.

Step 5

Select the modules that you have installed in the switch from the Hardware catalog and drag them to the appropriate rows in the table area of Device view: Appropriate SFP module for port type (combo port or fiber-only port)

The following figure shows the Device view and Hardware catalog with SFP modules. There is an uplink module for Gi SFP. The device in TIA is now ready to compile and download.

The following figure shows the Device view and Hardware catalog with SFP modules for IE3400 with the Fiber expansion module that has downlink SFP port Gi2/1-8, and where SFP GLC-FE-100FX-RGD is dragged to uplink port Gi2/8. The device in TIA is now ready to compile and download.