The Ethernet standard calls for a maximum bit-error rate of 10-8. The bit error-rate range is from 10-6 to 10-11. The bit error-rate input to the switch is a positive exponent. If you want to configure the bit error-rate of 10-9, enter the value 9 for the exponent. By default, the FCS bit error-rate is 10-8.
You can set the FCS error hysteresis threshold to prevent the toggle of the alarm when the actual bit-error rate fluctuates
near the configured rate. The hysteresis threshold is defined as the ratio between the alarm clear threshold to the alarm
set threshold, expressed as a percentage value.
For example, if the FCS bit error-rate alarm value is configured to 10-8, that value is the alarm set threshold. To set the alarm clear threshold at 5*10-10, the hysteresis, value h, is determined as follows:
h = alarm clear threshold / alarm set threshold
h = 5*10-10 / 10-8 = 5*10-2 = 0.05 = 5 percent
The FCS hysteresis threshold is applied to all ports on the switch. The allowable range is from 1 to 10 percent. The default
value is 10 percent. For more information, see the Configure FCS error threshold.