Table of Contents
Technical Specifications
Table A-1 lists specifications for the Cisco IAD1101 integrated access device.
Table A-1: Cisco IAD1101 Specifications
|
| Description |
Specifications |
|
Physical Characteristics of the Chassis
|
Dimensions: (HxWxD) 1.75 x 17.5 x 12 in.
Weight: 11 lb
|
|
Environmental
|
Operating Temperature: 0 to +40oC
Operating Humidity: 10 to 85% noncondensing
|
|
Storage Environmental
|
Storage Temperature: -20 to +65oC
Storage Humidity: 5 to 95% noncondensing
|
|
AC input voltage range
|
100 to 120 VAC (60Hz)
200 to 240 VAC (50Hz)
|
|
AC current rating (input)
|
Maximum current: 1.5A
|
|
DC input voltage ranges
|
-42.5 to -56 VDC, 5A fused
|
|
DC current rating (input)
|
Maximum current: 1.2A
|
Table A-2 lists regulatory approval requirements for the Cisco IAD1101.
Table A-2: Cisco IAD1101 Regulatory Approval Requirements
|
| Regulatory Requirement |
Approval Agency |
|
Safety
|
UL1950, CSA C22.2
|
|
Emission
|
FCC Part 15, Class B
|
|
Telcordia Technologies (formerly Bellcore)
|
GR-303, GR-308, TR-57, GR-253, GR-63, SR-3580, GR-1089, GR-436, GR-1244, TR-487, ANSI T1.101
|
|
NEBS
|
NEBS compliant
|
A single battery box contains four 12 VDC batteries connected in series, generating -48 VDC. The resulting current is used for backup power to the Cisco IAD1101 chassis.
Table A-3: Battery Box Specifications
|
|
Physical Characteristics
|
Dimensions: (HxWxD) 8.8 x 8.3 x 6.2 in.
Weight: 49 lb
|
|
Nominal Voltage
|
12V
|
|
Rated Capacity
|
12 Ah
|
|
Internal Resistance
|
14 Mohm
|
|
Maximum short-duration discharge current
|
180A
|
|
Maximum charging current
|
600 mA
|
|
Charging voltage
|
Standby: 13.5 to 13.8 V (-20V/oC)
Cyclic: 14.4 to 15.0 V (-30V/oC)
|
|
Battery backup time
|
Maximum 8 hr (24 FXS circuits at 18 CCS)
|
|
Battery charge time
|
24 hr
|