Verify the field-programmable device (FPD) firmware version running on each hardware component of Cisco NCS 1014 using the show hw-module fpd and show fpd package commands.
Use this task to confirm that the firmware that is running on each hardware component of Cisco NCS 1014 is compatible with the installed Cisco IOS XR image.
Cisco NCS 1014 hardware components require compatible firmware for proper operation. Using the show hw-module fpd command displays the current firmware version for each FPD, while show fpd package shows the firmware version bundled with the installed Cisco IOS XR software image.
Procedure
| 1. | Run the show hw-module fpd command.
Example:
|
|
| 2. | Run the show fpd package command to display the FPD image version that is available with the installed software release for each hardware component. Example:
|
What to do next
Upgrade all the FPDs by running the upgrade hw-module location all fpd all command in Cisco IOS XR EXEC mode. After the upgrade is complete, the Status column shows RLOAD REQ if the software requires a reload.
If a reload is required:
If the FPGA location is 0/RP0, run the admin hw-module location 0/RP0 reload command. This command reboots only the CPU. As a result, traffic is not impacted. If the FPGA location is 0/0, run the admin hw-module location all reload command. This command reboots the chassis. As a result, traffic is impacted. After the reload is complete, the new FPGA runs the current version.
If the firmware upgrade fails:
If the firmware upgrade fails, run the show logging command to view the details and upgrade the firmware again by using the preceding commands.
You can upgrade the firmware version of the power modules only when both the power modules are present and powered on.