System Setup and Software Installation Guide for Cisco NCS 1014, IOS XR Releases 26.x.x

PDF

System Setup and Software Installation Guide for Cisco NCS 1014, IOS XR Releases 26.x.x

Display alarms on Cisco NCS 1014

Want to summarize with AI?

Log in

Verify the alarms active on Cisco NCS 1014 by displaying them with the appropriate show alarms command.


Use this task to review and check active alarms on Cisco NCS 1014 to monitor system health and diagnose issues.

The show alarms command displays current and historical alarm details on Cisco NCS 1014, allowing you to assess the system status in either brief or detailed formats.

The show alarms command supports the following syntax:

Procedure

Run the show alarms brief card location location active command to display the active alarms for the card at the specified location in brief format.

Example:

RP/0/RP0/CPU0:ios#show alarms brief card location 0/RP0/CPU0 active

------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location        Severity     Group            Set Time                   Description
------------------------------------------------------------------------------------
0/0             Major        Ethernet         11/21/2023 11:11:35 UTC    HundredGigECtrlr0/0/0/2 - Carrier Loss On The LAN
0/3             Major        Ethernet         11/21/2023 11:11:37 UTC    HundredGigECtrlr0/3/0/2 - Remote Fault
0/0             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/0/0/4 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/3/0/3 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/3/0/4 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/0/0/5 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/0/0/6 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/0/0/7 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:39 UTC    HundredGigECtrlr0/3/0/5 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:39 UTC    HundredGigECtrlr0/3/0/6 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:38 UTC    HundredGigECtrlr0/3/0/7 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:11:43 UTC    HundredGigECtrlr0/0/0/3 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:57 UTC    HundredGigECtrlr0/3/0/8 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:57 UTC    HundredGigECtrlr0/3/0/9 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:59 UTC    HundredGigECtrlr0/3/0/12 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:11:59 UTC    HundredGigECtrlr0/3/0/13 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:03 UTC    HundredGigECtrlr0/0/0/9 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/0/0/8 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/0/0/10 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/0/0/11 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/0/0/12 - Local Fault
0/0             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/0/0/13 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:12:04 UTC    HundredGigECtrlr0/3/0/11 - Local Fault
0/3             Major        Ethernet         11/21/2023 11:12:05 UTC    HundredGigECtrlr0/3/0/10 - Local Fault
RP/0/RP0/CPU0:RINode1#show alarms brief card location 0/RP0/CPU0 active
Mon Feb 24 14:27:49.802 IST

------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location        Severity     Group            Set Time                   Description
------------------------------------------------------------------------------------
0               Major        Environ          02/21/2025 14:29:21 IST    Power Group Redundancy lost
0/3             Minor        Environ          02/21/2025 14:29:46 IST    TEMP_DX_PCB: Invalid sensor read error.
0/3             Minor        Environ          02/21/2025 14:29:46 IST    TEMP_DX_ZYNQ: temperature alarm
0/0/NXR0        Minor        Software         02/21/2025 14:29:58 IST    Ots0/0/0/0 - Neighbour not found
0/0             Minor        Controller       02/21/2025 14:29:58 IST    Ots0/0/0/0 - OTDR Reflectance Exceeded Absolute Threshold - Receive Direction
0/RP0/CPU0      Minor        Software         02/21/2025 14:30:30 IST    SW Upgrade is still allowed as SIA Grace Period is remaining
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_85V: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_2V: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_8V: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_2_5V: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_3_3V: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_85V_MGT: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_9V_MGT: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_2V_MGT: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_8V_MGT: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    PGOOD_VTT: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VIN_7_0V_ST: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VAUX_3_3V_ST: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VIN_12V_MOD: low voltage alarm
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_15V_CDR: low voltage alarm
Note

In the maintenance mode, all the alarms are suppressed and the show alarms command does not display the alarm details. Run the show controllers controller-type R/S/I/P command to view the client and trunk alarms.

The system displays all active alarms for the specified card location. You can use this information to verify the system’s operational status and diagnose issues.