Verify the alarms active on Cisco NCS 1014 by displaying them with the appropriate show alarms command.
Use this task to review and check active alarms on Cisco NCS 1014 to monitor system health and diagnose issues.
The show alarms command displays current and historical alarm details on Cisco NCS 1014, allowing you to assess the system status in either brief or detailed formats.
The show alarms command supports the following syntax:
Procedure
|
Run the show alarms brief card location location active command to display the active alarms for the card at the specified location in brief format.
Example:
RP/0/RP0/CPU0:ios#show alarms brief card location 0/RP0/CPU0 active
------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location Severity Group Set Time Description
------------------------------------------------------------------------------------
0/0 Major Ethernet 11/21/2023 11:11:35 UTC HundredGigECtrlr0/0/0/2 - Carrier Loss On The LAN
0/3 Major Ethernet 11/21/2023 11:11:37 UTC HundredGigECtrlr0/3/0/2 - Remote Fault
0/0 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/0/0/4 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/3/0/3 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/3/0/4 - Local Fault
0/0 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/0/0/5 - Local Fault
0/0 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/0/0/6 - Local Fault
0/0 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/0/0/7 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:39 UTC HundredGigECtrlr0/3/0/5 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:39 UTC HundredGigECtrlr0/3/0/6 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:38 UTC HundredGigECtrlr0/3/0/7 - Local Fault
0/0 Major Ethernet 11/21/2023 11:11:43 UTC HundredGigECtrlr0/0/0/3 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:57 UTC HundredGigECtrlr0/3/0/8 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:57 UTC HundredGigECtrlr0/3/0/9 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:59 UTC HundredGigECtrlr0/3/0/12 - Local Fault
0/3 Major Ethernet 11/21/2023 11:11:59 UTC HundredGigECtrlr0/3/0/13 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:03 UTC HundredGigECtrlr0/0/0/9 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/0/0/8 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/0/0/10 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/0/0/11 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/0/0/12 - Local Fault
0/0 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/0/0/13 - Local Fault
0/3 Major Ethernet 11/21/2023 11:12:04 UTC HundredGigECtrlr0/3/0/11 - Local Fault
0/3 Major Ethernet 11/21/2023 11:12:05 UTC HundredGigECtrlr0/3/0/10 - Local Fault
RP/0/RP0/CPU0:RINode1#show alarms brief card location 0/RP0/CPU0 active
Mon Feb 24 14:27:49.802 IST
------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location Severity Group Set Time Description
------------------------------------------------------------------------------------
0 Major Environ 02/21/2025 14:29:21 IST Power Group Redundancy lost
0/3 Minor Environ 02/21/2025 14:29:46 IST TEMP_DX_PCB: Invalid sensor read error.
0/3 Minor Environ 02/21/2025 14:29:46 IST TEMP_DX_ZYNQ: temperature alarm
0/0/NXR0 Minor Software 02/21/2025 14:29:58 IST Ots0/0/0/0 - Neighbour not found
0/0 Minor Controller 02/21/2025 14:29:58 IST Ots0/0/0/0 - OTDR Reflectance Exceeded Absolute Threshold - Receive Direction
0/RP0/CPU0 Minor Software 02/21/2025 14:30:30 IST SW Upgrade is still allowed as SIA Grace Period is remaining
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_0_85V: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_1_2V: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_1_8V: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_2_5V: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_3_3V: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_0_85V_MGT: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_0_9V_MGT: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_1_2V_MGT: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_1_8V_MGT: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST PGOOD_VTT: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VIN_7_0V_ST: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VAUX_3_3V_ST: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VIN_12V_MOD: low voltage alarm
0/3 Critical Environ 02/21/2025 14:31:55 IST VMON_1_15V_CDR: low voltage alarm
Note
In the maintenance mode, all the alarms are suppressed and the show alarms command does not display the alarm details. Run the show controllers controller-type R/S/I/P command to view the client and trunk alarms.
|
The system displays all active alarms for the specified card location. You can use this information to verify the system’s operational status and diagnose issues.