Configure, verify, and prepare a Cisco NCS 1014 line card for operation, including physical installation, operational checks, environmental verification, and FPD upgrade.
Install the Cisco NCS 1014 line card and ensure it becomes fully operational within the chassis.
Procedure
-
Insert the line card into the slot.
-
Wait until the line card LED turns green.
-
Check that the PID is in OPERATIONAL status using the show platform command.
Example:
CCMD-16-C and CCM-16-L line cards:
RP/0/RP0/CPU0:ios#show platform Fri Sep 22 06:56:28.653 UTC Node Type State Config state -------------------------------------------------------------------------------- 0/RP0/CPU0 NCS1K14-CNTLR-K9(Active) IOS XR RUN NSHUT,NMON 0/PM0 NCS1K4-AC-PSU OPERATIONAL NSHUT,NMON 0/FT0 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT1 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT2 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/0/NXR0 NCS1K14-CCMD-16-L OPERATIONAL NSHUT,NMON 0/2/NXR0 NCS1K14-CCMD-16-C OPERATIONAL NSHUT,NMON 0/3/NXR0 NCS1K14-CCMD-16-C OPERATIONAL NSHUT,NMONExample:
2.4T line card:
RP/0/RP0/CPU0:ios#show platform Fri Sep 22 06:56:28.653 UTC Node Type State Config state -------------------------------------------------------------------------------- 0/RP0/CPU0 NCS1K14-CNTLR-K9(Active) IOS XR RUN NSHUT,NMON 0/PM0 NCS1K4-AC-PSU OPERATIONAL NSHUT,NMON 0/FT0 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT1 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT2 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/2/NXR0 NCS1K14-2.4T-K9 OPERATIONAL NSHUT,NMON 0/3/NXR0 NCS1K14-BLANK PRESENT NSHUT,NMONExample:
2.4TX line card:
RP/0/RP0/CPU0:ios#show platform Node Type State Config state -------------------------------------------------------------------------------- 0/RP0/CPU0 NCS1K14-CNTLR-K9(Active) IOS XR RUN NSHUT,NMON 0/PM0 NCS1K4-AC-PSU-2 OPERATIONAL NSHUT,NMON 0/FT0 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT1 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT2 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/0/NXR0 NCS1K14-2.4T-X-K9 OPERATIONAL NSHUT,NMON 0/1/NXR0 NCS1K14-2.4T-X-K9 OPERATIONAL NSHUT,NMON 0/2/NXR0 NCS1K14-2.4T-X-K9 OPERATIONAL NSHUT,NMON 0/3/NXR0 NCS1K14-2.4T-X-K9 OPERATIONAL NSHUT,NMONExample:
EDFA2 line card:
RP/0/RP0/CPU0:sanity_176#show platform Node Type State Config state -------------------------------------------------------------------------------- 0/RP0/CPU0 NCS1K14-CNTLR-K9(Active) IOS XR RUN NSHUT,NMON 0/PM0 NCS1K4-AC-PSU-2 OPERATIONAL NSHUT,NMON 0/PM1 NCS1K4-AC-PSU-2 OPERATIONAL NSHUT,NMON 0/FT0 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT1 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT2 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/0/NXR0 NCS1K14-BLANK PRESENT NSHUT,NMON 0/1/NXR0 NCS1K4-1.2T-K9 OPERATIONAL NSHUT,NMON 0/2/NXR0 NCS1K14-BLANK PRESENT NSHUT,NMON 0/3/NXR0 NCS1K14-EDFA2 OPERATIONAL NSHUT,NMON 0/4 NCS1K-MD-32O-CE OPERATIONAL NSHUT,NMON 0/5 NCS1K-MD-32E-CE OPERATIONAL NSHUT,NMONExample:
2.4TA line card:
RP/0/RP0/CPU0:ios#show platform Mon Jan 12 11:36:27.652 UTC Node Type State Config state -------------------------------------------------------------------------------- 0/RP0/CPU0 NCS1K14-CNT-B-K9(Active) IOS XR RUN NSHUT,NMON 0/PM1 NCS1K4-AC-PSU OPERATIONAL NSHUT,NMON 0/FT0 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT1 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/FT2 NCS1K14-FAN OPERATIONAL NSHUT,NMON 0/0/NXR0 NCS1K14-BLANK PRESENT NSHUT,NMON 0/1/NXR0 NCS1K14-2.4T-A-K9 OPERATIONAL NSHUT,NMON 0/2/NXR0 NCS1K14-2.4T-A-K9 OPERATIONAL NSHUT,NMON 0/3/NXR0 NCS1K14-BLANK PRESENT NSHUT,NMON -
Check the line card environment parameters using the show environment [ power | voltage | current | temperature ] [ location location] command.
Example:
RP/0/RP0/CPU0:ios#show environment power ================================================================================ CHASSIS LEVEL POWER INFO: 0 ================================================================================ Total output power capacity (Group 0 + Group 1) : 2500W + 0W Total output power required : 1636W Total power input : 637W Total power output : 568W Power Group 0: ================================================================================ Power Supply ------Input---- ------Output--- Status Module Type Volts Amps Volts Amps ================================================================================ 0/PM1 NCS1K4-AC-PSU-2 227.5 2.8 12.1 47.0 OK Total of Group 0: 637W/2.8A 568W/47.0A ================================================================================ Location Card Type Power Power Status Allocated Used Watts Watts ================================================================================ 0/RP0/CPU0 NCS1K14-CNTLR-K9 73 20 ON 0/FT0 NCS1K14-FAN 170 167 ON 0/FT1 NCS1K14-FAN 170 85 ON 0/FT2 NCS1K14-FAN 170 159 ON 0/0/NXR0 NCS1K14-2.4T-L-K9 460 38 ON 0/2/NXR0 NCS1K14-2.4T-X-K9 410 0 ON 0/3/NXR0 NCS1K14-CCMD-16-C 110 16 ON 0/Rack NCS1014 73 14 ONNote
-
Insert a filler into any unused slot to ensure proper airflow and optimal system temperature.
-
Insert a clip into any unused port to maintain optimal card temperature.
-
Tighten the top and bottom screws to secure the line card in the chassis.
-
-
Upgrade the FPDs of the line card depending on the output of the show hw-module location 0/line-card-slot fpd command.