This topic describes the show commands used to verify the CFM configuration, including commands to display configuration errors and a list of local maintenance points.
To verify the CFM configuration, use one or more of the following commands:
| Command |
Purpose |
|---|---|
| show ethernet cfm configuration-errors [domain domain-name] [interface interface-path-id ] |
Displays information about errors that are preventing configured CFM operations from becoming active, as well as any warnings that have occurred. |
| show ethernet cfm local maintenance-points domain name [service name] | interface type interface-path-id] [mep | mip] |
Displays a list of local maintenance points. |
After you configure CFM, the error message, cfmd[317]: %L2-CFM-5-CCM_ERROR_CCMS_MISSED : Some received CCMs have not been counted by the CCM error counters, may display. This error message does not have any functional impact and does not require any action from you.