Catalyst 2900 User Guide
|
||||||||||
Confirming the Installation
![]() |
|||||||||||
Table of ContentsConfirming the InstallationUsing the Module LEDs
Using the ping Command Using the show system Command Using the show configuration Command Using the show port Command Confirming the InstallationThis section describes procedures used to confirm that the hardware and software installation and configuration procedures were successful. The following procedures are discussed:
Using the Module LEDsThis section describes the LEDs used to confirm and troubleshoot operation of the Catalyst 2900 modules. The LEDs on the supervisor engine module indicate the system power and processor status; LEDs on the switching modules indicate the status of the individual switching module and their interfaces. Status LEDsWhen the Catalyst 2900 is plugged in it runs a series of diagnostic tests. During this period, the status LED is orange. If the switch passes all the tests, the status LED is green. If any tests fail, the status LED turns red. The status LED will also be orange when it is explicitly disabled with the system software. Supervisor Engine Module LEDsThe LEDs on the supervisor engine module reflect how the system's various components are operating and are described in Table 7-1. For a description of the power supply shutdown conditions and threshold status levels, refer to the section "Environmental Monitoring" in the chapter "What Is the Catalyst 2900?." The supervisor engine module LEDs are shown in Figure 7-1. Figure 7-1: Supervisor Engine Module LEDs
Table 7-1: Supervisor Engine Module LEDs Switch Load MeterThe switch load-meter LEDs provide a visual indication (as an approximate percentage) of the current traffic load over the backplane. (See Figure 7-2.) Figure 7-2: Switch Load LED
10/100BaseTX LEDsThe LEDs provide status information for the module and individual 10/100 Mbps Fast Ethernet interface connections. The LEDs are shown in Figure 7-3 and described in Table 7-3. Figure 7-3: 10/100 Mbps Fast Ethernet Switching Module LEDs
Table 7-2: 10/100 Mbps Fast Ethernet Module LED Descriptions 100BaseFX 12 Port LEDsThe LEDs on the faceplate of the Fast Ethernet switching module (100BaseFX 12 port), shown in Figure 7-4, are described in Table 7-3. Figure 7-4: 100BaseFX LEDs
Table 7-3: 100BaseFX LED Descriptions Using the ping CommandEnter the ping command to send Internet Control Message Protocol (ICMP) echo request packets to another node on the network to confirm the connection to that node. ping -s host [packet_size] [packet_count]Syntax Description
Usage GuidelinesEnter Ctrl-C to stop pinging. Following are sample results of the ping command:
ExampleIn the following example, a host with IP alias elvis is pinged a single time, then pinged once per second until Ctrl-C is entered to stop pinging: Console> ping elvis elvis is alive Console> ping -s elvis ping elvis: 56 data bytes 64 bytes from elvis: icmp_seq=0. time=11 ms 64 bytes from elvis: icmp_seq=1. time=8 ms 64 bytes from elvis: icmp_seq=2. time=8 ms 64 bytes from elvis: icmp_seq=3. time=7 ms 64 bytes from elvis: icmp_seq=4. time=11 ms 64 bytes from elvis: icmp_seq=5. time=7 ms 64 bytes from elvis: icmp_seq=6. time=7 ms ^C ----elvis PING Statistics---- 7 packets transmitted, 7 packets received, 0% packet loss round-trip (ms) min/avg/max = 7/8/11 Console> Using the show system CommandEnter the show system command to display the power supply, fan, temperature alarm, system, and modem status; the number of days, hours, minutes, and seconds since the last system restart; the baud rate; the MAC address range; and the system name, location, and contact. ExampleIn the following example, the system status and other information is displayed: Console> show system PS-Status Fan-Status Temp-Alarm Sys-Status Uptime d,h:m:s --------- ---------- ---------- ---------- -------------- ok ok off ok 27,17:05:50 Modem Baud MAC-Address-Range -------- ----- ------------------------------------- disabled 9600 00-06-3c-e4-0a-00 to 00-60-3e-e4-0d-ff System Name System Location System Contact ------------------------ ------------------------ ---------------------- WBU-Catalyst-2900 5 Closet 202 1/F Luis x5529 Console> Using the show configuration CommandEnter the show config command to display the current system configuration: Console> show config begin set password $1$FMFQ$HfZR5DUszVHIRhrz4h6V70 set enablepass $1$FMFQ$HfZR5DUszVHIRhrz4h6V70 set prompt Console> ! #system set system baud 9600 set system modem disable set system name Catalyst 2900 set system location Sunnyvale, CA set system contact Bob Lewis ! #snmp set snmp rmon enable set snmp community read-only public set snmp community read-write private set snmp community read-write-all secret set snmp trap 171.69.194.181 public set snmp trap disable ! #vlan/trunk clear trunk all ! set vlan 1 1/1-2,2/1-24 ! #trunks ! #MAC filters clear filter all ! #cam set cam agingtime 0 ! #spantree #vlan 1 set spantree enable 1 set spantree fwddelay 20 1 set spantree hello 2 1 set spantree maxage 20 1 set spantree priority 45 1 set spantree portpri 1/1 32 set spantree portcost 1/1 100 set spantree portpri 1/2 32 set spantree portcost 1/2 100 set spantree portpri 2/1 32 set spantree portcost 2/1 100 . . . set spantree portpri 2/12 32 set spantree portcost 2/12 100 ! #vlan trunk/monitor ! #ip set interface sc0 192.122.174.220 255.255.255.0 192.122.174.255 set redirect enable set route 0.0.0.0 192.122.174.102 1 set arp agingtime 1200 ! #cdp set cdp 1/1 enable 60 set cdp 1/2 enable 60 set cdp 2/1 enable 60 set cdp 2/2 enable 60 set cdp 2/3 enable 60 . . . set cdp 2/12 enable 60 ! #ipalias set ipalias default 0.0.0.0 set ipalias cres 192.122.173.42 set ipalias calypso 171.69.194.181 ! #alias ! #port monitoring set monitor 1 1/1 both set monitor disable ! #module 1 set port enable 1/1 set port name 1/1 set port duplex 1/1 auto set port speed 1/1 10 set port level 1/1 auto set port enable 1/2 set port name 1/2 set port duplex 1/2 10 set port speed 1/2 100 set port level 1/2 auto ! #module 2 set module enable 2 ! set port enable 2/1 set port name 2/1 auto set port duplex 2/1 100 set port level 2/1 100 set port enable 2/2 set port name 2/2 set port duplex 2/2 10 set port level 2/2 auto . . set port enable 2/12 set port name 2/12 set port duplex 2/12 10 set port level 2/12 10 ! end Using the show port CommandEnter the show port command to display the current system configuration: Console> show port Port Name Status Vlan Level Duplex Speed Type ---- ----------- -------- -------- ------ ------ ------ ----------- 1/1 ready 1 normal half 100 100 BASE-TX 1/2 ready 1 normal half 100 100 BASE-TX 2/1 network ready 1 normal half 10 10 BASE-T 2/2 connect 1 normal half 10 10 BASE-T 2/3 connect 1 normal half 10 10 BASE-T 2/4 connect 1 normal half 10 10 BASE-T 2/5 connect 1 normal half 10 10 BASE-T 2/6 connect 1 normal half 10 10 BASE-T 2/7 connect 1 normal half 10 10 BASE-T 2/8 connect 1 normal half 10 10 BASE-T 2/9 connect 1 normal half 10 10 BASE-T 2/10 connect 1 normal half 10 10 BASE-T 2/11 connect 1 normal half 10 10 BASE-T 2/12 connect 1 normal half 10 10 BASE-T Port Align-Err FCS-Err Xmit-Err Rcv-Err ---- ---------- ---------- ---------- ---------- 1/1 0 0 0 0 1/2 0 0 0 0 2/1 0 0 0 0 2/2 0 0 0 0 2/3 0 0 0 0 2/4 0 0 0 0 2/5 0 0 0 0 2/6 0 0 0 0 2/7 0 0 0 0 2/8 0 0 0 0 2/9 0 0 0 0 2/10 0 0 0 0 2/11 0 0 0 0 2/12 0 0 0 0 Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Giants ---- ---------- ---------- ---------- ---------- ---------- ---------- 1/1 0 0 0 0 0 0 1/2 0 0 0 0 0 0 2/1 0 0 0 0 0 0 2/2 0 0 0 0 0 0 2/3 0 0 0 0 0 0 2/4 0 0 0 0 0 0 2/5 0 0 0 0 0 0 2/6 0 0 0 0 0 0 2/7 0 0 0 0 0 0 2/8 0 0 0 0 0 0 2/9 0 0 0 0 0 0 2/10 0 0 0 0 0 0 2/11 0 0 0 0 0 0 2/12 0 0 0 0 0 0 Last-Time-Cleared -------------------------- Fri Apr 28 1995, 16:34:25 Console> Console> (enable) show port Port Align-Err FCS-Err Xmit-Err Rcv-Err Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Giants Last-Time-Cleared |
|||||||||||
|
|