Cisco Catalyst SD-WAN Rugged Series Router Configuration Guide, Release 26.x and Later

PDF

Cisco Catalyst SD-WAN Rugged Series Router Configuration Guide, Release 26.x and Later

Configure WIM on Cisco Catalyst IR1800 Rugged Routers in CAPWAP Mode

Want to summarize with AI?

Log in

Configures WIM on Cisco Catalyst IR1800 Rugged Routers in CAPWAP Mode using CLI templates in Cisco SD-WAN Manager . CLI templates execute commands in global config mode.


For more information about using CLI templates, see CLI Add-on Feature Templates and CLI Templates .

Note

By default, CLI templates execute commands in global config mode.

Procedure

  1. Create a VLAN interface dedicated only to the layer 2 interface:

    Example:

    interface Vlanid 

    The following example shows how to create a VLAN interface:

    interface Vlan 50,100-200
  2. Assign the layer 2 interface to the VLAN that you created:

    Example:

    interfaceWlan-GigabitEthernet0/1/4 switchport accessvlan id
      switchport trunk native vlanvlan id switchport modetrunk 

    The following example shows how to assign a layer 2 interface to the created VLAN

    interface Wlan-GigabitEthernet0/1/4 switchport access vlan id
                      switchport access vlan 50,100-200
                      switchport trunk native vlan vlan 50,100-200
                      switchport mode trunk
  3. Create a DHCP pool for the VLAN:

    Example:

    ip dhcppoolvlan id 
     networkip subnetip mask  
    default-routerrouter ip address 

    The following example shows how to create a DHCP pool for the VLAN:

    ip dhcp pool vlan 50,100-200
               network 255.255.255.0 255.0.0
               default-router 192.0.2.1
    Note

    Skip this step if you are using an external DHCP server.