Overview

Teaches you how to modify side properties. Follow these detailed step-by-step instructions carefully to ensure the specific configuration is applied correctly and securely within your network.

Table 1. Feature History

Feature Name

Release Information

Feature Description

Colorless Add/Drop Configuration with SMR-9 Card

Cisco ONP Release 24.3.1

In addition to the SMR-20 card, the colorless Add/Drop configuration can now be added to both SSON and non-SSON networks using the SMR-9 card, providing more flexibility to use the available SMR-9 ports for add/drop functionality.

Table 2. Feature History

Feature Name

Release Information

Feature Description

NCS2K-RMN-CTP-C+L support

Cisco ONP Release 5.0

Cisco ONP now supports the passive module, NCS2K-RMN-CTP-C+L (C- and L-band counterpropagating Raman amplifier), starting from the NCS 2000 system release 12.3.1 for SSON and non-SSON networks.

Table 3. Feature History

Feature Name

Release Information

Feature Description

Support for NCS2K-MF-CL-SC (C and L-band combiner and splitter)

Cisco ONP Release 4.2

Cisco ONP supports the passive module, NCS2K-MF-CL-SC (C and L-band combiner and splitter), starting from the NCS 2000 system release 12.2 for SSON and non-SSON networks. This feature enables combining C and L band wavelengths.

Use this procedure to modify the properties of a side in a site.

Procedure

1.

Open the network where you want to modify the side properties of a site.

2.

Choose Network > Entity Editor.

3.

In the Entity Editor window, navigate to Sites > Site > Side.

4.

Modify the side properties as required. See these references for the property descriptions.

5.

Click Update.


General side properties

This table describes various general properties for the sides of a site.

Options

Platform

Description

Label

NCS 2000

NCS 1010

NCS 1001

Displays the label of the side.

Editable for NCS 1001.

Note

For L-band nodes, the suffix L is added to the side label.

—

—

Type

NCS 2000

NCS 1010

NCS 1001

Displays the type of the side. You cannot edit this property.

—

—

Omni Variant

NCS 1010

Select the type of omnidirectional add/drop stage.

  • Dual OLT

  • 4x4 COFS (supports only C-band Omni colorless)

    You can choose 4x4 COFS only if the Structure under the Sites properties is Line.

Note

In a site, all Omni edges must have the same Omni Variant. Changing the Omni Variant for one edge updates the variant for all edges.

Dual OLT

Omni Directional Ports

NCS 1010

Enter the number of omnidirectional ports.

It is applicable only for the 4x4COFS Omni variant. The available values range from 1 through 4, with a default value of 4.

—

—

Node Address

NCS 1010

NCS 1001

Enter the node address

—

—

MPO Cable

NCS 1010

Choose the MPO cable.

  • Auto

  • 16MPO-MPO

  • 24MPO-MPO

Auto

Colorless Ports (Displayed for Line side)

NCS 2000

Enter the number of colorless ports.

From Release 24.3.1, this property is enabled for the SMR-9 card.

—

—

Contentionless Ports (Displayed for Contentionless side)

NCS 2000

Choose the number of contentionless ports.

1-16

16

Enable C+L Band S/C (Displayed for Line side type)

NCS 2000

Cisco ONP supports the following passive modules:

  • NCS2K-MF-CL-SC (C and L-band combiner and splitter), starting from the NCS 2000 system release 12.2 for SSON and non-SSON networks. Check this check box to enable the NCS2K-MF-CL-SC card. This card is supported for ROADM, OLA, and traffic nodes, but not on the passthrough node.

    Note

    When you enable this option on a side:

    • It is automatically enabled on the side that is connected to the selected side through a fiber.

    • The fiber property Raman Amplified is automatically disabled, and the opposite way.

    • This card introduces a certain amount of attenuation and insertion loss that is reflected in the ANS parameters.

    The NCS2K-MF-CL-SC module does not appear in the layout.

  • NCS2K-RMN-CTP-C+L (C- and L-band counterpropagating Raman amplifier), starting from the NCS 2000 system release 12.3 for SSON and non-SSON networks. Check this check box to enable the NCS2K-RMN-CTP-C+L card.

    Note

    When you enable this option on a side:

    • If you enable the fiber property Raman Amplified, then the NCS2K-RMN-CTP-C+L card is automatically forced.

    • If you disable the fiber property Raman Amplified, then the NCS2K-MF-CL- SC card is automatically forced.

    • Fiber property Raman Amplified is automatically disabled for NCS 2000 system release 12.2.

    The NCS2K-RMN-CTP-C+L module appears in the layout.

—

—

Band Type

NCS 1010

NCS 1001

Choose the required band type.

  • C-Band

  • C+L Futuristic

C-Band

NCS 1010 Line Card

NCS 1010

Choose whether the Line Card faceplate is Standard Faceplate or Enhanced Faceplate.

Note
If you assigned a Scalable Upto Degree value that is supported for both standard and enhance at the site level, then you can select Standard Faceplate in one side and Enhanced Faceplate in another side.
  • Standard Faceplate

  • Enhanced Faceplate

Standard Faceplate

Probe Channel

NCS 1014

The Probe channel pluggable option that you selected at the network level applies to all the edges of all sites in the network. This field is noneditable.

—

—

OTDR Pluggable

NCS 1014

The OTDR pluggable option that you selected at the network level applies to all the edges of all sites in the network. This field is noneditable.

—

—

OSC Pluggable

NCS 1001

Choose the type of OSC pluggable.

  • CWDM-SFP-1510

  • CWDM-SFP-1610

  • ONS-SC-Z3-1510

  • ONS-SC-Z3-1610

  • ONS-SE-155-1510

CWDM-SFP-1510

NCS 1014

Choose the type of OSC pluggable. The available option is:

ONS-SC-PTP-1510

ONS-SC-PTP-1510


Bill of materials and layout properties for sides

This table describes various bill of materials and layout properties for the sides of a site.

Table 4. Bill of materials and layout properties for sides

Options

Platform

Description

Bill of Material

License Suite

NCS 1010

Choose whether the License Suite is Essential (RTU +SIA3) or Advanced (RTU +SIA3).

NCS 1014

The default option is RTU + SIA3. It is noneditable.

Layout

Power Supply

NCS 1010

NCS 1001

Choose the type of Power Supply. The available options are Auto, AC Power, and DC Power.

The default option is Auto.

With the Auto option, the default power supply is selected as DC Power.

Chassis Type

NCS 1010

Choose the type of chassis. The available options are:

  • NCS 1010

  • NCS 1020

NCS1014 Grouping

NCS 1014

This check box is enabled by default. If you enabled NCS 1014 grouping at the site level, then this check box becomes noneditable.

Controller Card

NCS 1010

Choose the type of the controller card. The available options are:

  • Auto

  • NCS1010-CNTRL-K9

  • NCS1010-CNTRL-B-K9

NCS 1001

NCS1K-CNTLR2 is default.

Redundant Controller Card

NCS 1010

NCS 1001

Displays the redundant controller card, if any. Else displays No.

UTS AC Power Cables

NCS 1010

NCS 1001

Choose the type of cables to be used for the AC power supply. You can choose the cables when the Power Supply is set as AC Power or DC Power.

Redundant Power Scheme

NCS 1010

NCS 1001

Choose the redundant power scheme from the drop-down list to configure the number of working and protected power units for the chassis. The available options are Auto, 1+0, and 1+1.

MF Unit

NCS 1010

NCS 1001

Choose the mechanical frame for the passive optical modules from the drop-down list. The options available are Auto, MF-1RU, and MF-4RU.

Direct LC Add/Drop

NCS 1010

Choose the number of LC ports to reserve for Direct Add/Drop connection. The range of values is 0–14. This property appears for networks from R7.10.1.

The chosen option will not be used for Degree Connection.


Enhanced face plate properties for sides

This table describes various enhanced face plate properties for the sides of a site.

Table 5. Enhanced face plate properties for sides

Options

Platform

Description

Available options

Default

Degree Priority

NCS 1010

Choose the port type for interconnect degree priority.

Note
This field appears only when you select NCS 1010 Line Card as Enhanced Faceplate.
  • LC Ports

  • MPO Group

LC Ports

Direct LC Add/Drop

NCS 1010

Choose the number of LC ports to reserve for Direct Add/Drop connection. This property appears for networks from R7.10.1.

The chosen option will not be used for Degree Connection.

The range of values is 0–14.