Cisco C9550 Series Smart Switches Hardware Installation Guide

PDF

Cisco C9550 Series Smart Switches Hardware Installation Guide

Environmental specifications

Want to summarize with AI?

Log in

Environmental specifications of the switch, power supply modules, and fans.


This section describes the environmental specifications for the Cisco C9550 Series Smart switches, power supply modules, and fans.

Table 1. Environmental specifications for the switch

Environmental ranges

Operating temperature

  • With C9550-FAN-1U-F: -5°C to +35°C (23° to 95°F)

  • With C9550-FAN-1U-R: -5°C to +45°C (23° to 113°F)

  • With C9550-FAN-2U-F: -5°C to +35°C (23° to 95°F)

  • With C9550-FAN-2U-R: -5°C to +45°C (23° to 113°F)

Storage temperature

-40°C to 70°C (-40° to 158°F)

Relative humidity

  • Operating: 10% to 85% (noncondensing)

  • Non-Operating: 0% to 95% (noncondensing)

Operating altitude

Up to 6,000 feet (1,800 m)

Storage altitude

Up to 10,000 feet (3,000 m)

Heat dissipation (in British Thermal Units [BTU])

1000 BTU/hr = 293W

  • C9550-24L4CD: 1,880 BTU/hr

  • C9550-32C: 2,200 BTU/hr

  • C9550-48L4CD: 2,000 BTU/hr

  • C9550-64C-XL: 3,754 BTU/hr

  • C9550-96L4D: 3,200 BTU/hr

Acoustic measurements

This section lists the acoustic measurements for the different switch models.

Switch model

Sound power level

C9550-24L4CD

  • Maximum value: Not greater than 87.2 LWAd dB

  • Typical value: 60.4LWAd dB at 27C

C9550-48L4CD

  • Maximum value: Not greater than 85.7 LWAd dB

  • Typical value: 61LWAd dB at 27C

C9550-96L4D

  • Not greater than 89.3 LWAd dB