System Setup and Software Installation Guide for Cisco NCS 1001

PDF

System Setup and Software Installation Guide for Cisco NCS 1001

Verify inventory

Want to summarize with AI?

Log in

Use this procedure to verify the hardware inventory of the NCS 1001 using the show inventory command..


Ensure accurate hardware information is available for NCS 1001 devices.

The show inventory command displays hardware inventory details, including product IDs, version IDs, and serial numbers.

Follow these steps to verify the inventory for NCS 1001:

Procedure

1.

Enter the show inventory command to display inventory details in Cisco IOS XR EXEC mode.

Example:


RP/0/RP0/CPU0:ios# show inventory

Sun Mar  5  02:42:57.359 UTC

 Name: Rack 0                Descr: Network Convergence System 1001 line system 3 slots
 PID: NCS1001-K9             VID: V00                   SN: CAT2018B033

 Name: 0/0                   Descr: Network Convergence System 1001 line system 3 slots
 PID: NCS1001-K9             VID: V00                   SN: CAT2018B033

 Name: 0/3                   Descr: Network Convergence System 1000 amplifier module
 PID: NCS1K-EDFA             VID: V01                   SN: IIF2044002L

 Name: 0/RP0-SFP-PORT        Descr: Unqualified SFP Pluggable Optics Module
 PID: UNQUALIFIED-SFP        VID:                       SN:

 Name: 0/RP0                 Descr: Network Convergence System 1000 Controller 2
 PID: NCS1K-CNTLR2           VID: V01                   SN: CAT2051B0R5

 Name: 0/FT0                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT1                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT2                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT3                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/PM0                 Descr: Network Convergence System 1000 2KW AC PSU 2
 PID: NCS1K-2KW-AC2          VID: V01                   SN: POG2049JT21

 Name: 0/PM1                 Descr: Network Convergence System 1000 2KW AC PSU 2
 PID: NCS1K-2KW-AC2          VID: V01                   SN: POG2049JT01
NAME: "0/RP0-USB0", DESCR: "NCS 1000 32 chs Even Mux/Demux Patch Panel - 150GHz - C-band"
PID: NCS1K-MD-32E-CE   , VID: V00 , SN: ACW2804YJ23

NAME: "0/RP0-USB1", DESCR: "NCS 1000 32 chs Odd Mux/Demux Patch Panel - 150GHz - C-band"
PID: NCS1K-MD-32O-CE   , VID: V00 , SN: ACW2804YH08
NAME: "0/RP0-USB0", DESCR: "NCS 1000 4 Channel add drop multiplexer Module"
PID: 15216-FLD-4-55.7=   , VID: V00 , SN: OPL19380046
2.

Use the admin command to enter the System Admin EXEC mode.

Example:

RP/0/RP0/CPU0:router# admin
3.

Enter the show inventory command to display inventory information for all physical entities.

Example:

sysadmin-vm:0_RP0# show inventory 
Sun Mar  5  02:44:30.350 UTC

 Name: Rack 0                Descr: Network Convergence System 1001 line system 3 slots
 PID: NCS1001-K9             VID: V00                   SN: CAT2018B033

 Name: 0/0                   Descr: Network Convergence System 1001 line system 3 slots
 PID: NCS1001-K9             VID: V00                   SN: CAT2018B033

 Name: 0/3                   Descr: Network Convergence System 1000 amplifier module
 PID: NCS1K-EDFA             VID: V01                   SN: IIF2044002L

 Name: 0/RP0-SFP-PORT        Descr: Unqualified SFP Pluggable Optics Module
 PID: UNQUALIFIED-SFP        VID:                       SN:

 Name: 0/RP0                 Descr: Network Convergence System 1000 Controller 2
 PID: NCS1K-CNTLR2           VID: V01                   SN: CAT2051B0R5

 Name: 0/FT0                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT1                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT2                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/FT3                 Descr: Network Convergence System 1001 Fan
 PID: NCS1K1-FAN             VID: V01                   SN: N/A

 Name: 0/PM0                 Descr: Network Convergence System 1000 2KW AC PSU 2
 PID: NCS1K-2KW-AC2          VID: V01                   SN: POG2049JT21

 Name: 0/PM1                 Descr: Network Convergence System 1000 2KW AC PSU 2
 PID: NCS1K-2KW-AC2          VID: V01                   SN: POG2049JT01

In the above output, the significant fields are:

  • PID : Physical model name of the chassis or node.

  • VID : Physical hardware revision of the chassis or node.

  • SN : Physical serial number for the chassis or node.

The inventory output displays physical entity information for the NCS 1001 chassis, modules, fans, power modules, and connected passive modules.