Table Of Contents
Symbols - Numerics - A - B - C - D - E - F - G - H - I - J - L - M - N - O - P - R - S - T - V - W -
Index
Symbols
+24 VDC power supply 2-67, 2-68, 8-202, 8-203, 8-204
Numerics
Cisco ASR 1002-F Router 9-256
Cisco ASR 1002 Router 8-210, 11-336
Cisco ASR 1004 Router 7-175
Cisco ASR 1006 Router 6-140, 10-297
1 GB flash token memory stick 13-417
24V DC power supply 8-230, 13-458
A
AC power supply
removing 13-427, 13-441, 13-448, 13-465
replacing 13-428, 13-442, 13-449, 13-467
airflow
cautions 7-166, 8-207, 9-252, 10-287, 11-333
exhaust 1-10
monitoring 1-10
alarms, DB-25 connector 2-46
alarms, route processor, how they work 2-46
altitude 5-107
ASR1000 Embedded Services Processor 10G Non Crypto Capable feature 3-81
ASR1000-ESP10-N 3-81
ASR1000-RP1 DIMM Memory 13-391
ASR1000-RP2 DIMM Memory 13-396, 13-400, 13-406
ASR1000 Series features 1-3
ASR1006-PWR-AC 2-49, 2-50, 6-127, 6-149, 13-429
ASR1006-PWR-DC 2-33, 2-49, 2-53, 6-151, 6-154, 6-156, 13-427, 13-431, 13-433, 13-435, 13-438
ASR1013/06-PWR-AC 2-49, 2-50, 2-70, 2-71, 2-75, 6-150, 13-430
ASR1013/06-PWR-DC 2-49, 2-70, 2-75, 6-152, 6-155, 6-157, 13-427, 13-432, 13-434, 13-436, 13-439
auxiliary connector 8-222, 9-266, 11-346
auxiliary port cables 6-146, 7-181, 8-222, 9-266, 10-304, 11-346
B
baud rate 6-146, 7-182, 8-222, 9-266, 10-305, 11-346
C
cable length, factors determining 5-112
cable-management kit using 6-131, 7-166, 8-207, 9-252, 10-287, 11-333
cables
auxiliary port 6-146, 7-181, 8-222, 9-266, 10-304, 11-346
connecting port adapter 6-145, 7-181, 8-222, 9-266, 10-303, 11-346
console port 6-146, 7-181, 8-222, 9-266, 10-304, 11-346
crossover 6-158, 7-190, 8-238, 9-275, 10-313, 11-347
Fast Ethernet Management port 6-146, 7-182, 10-305
RJ-45 pinout A-489, A-492, A-493, A-496, A-497, A-498, A-501, A-502, B-505, B-506, B-507
specifications A-487
chassis
air circulation 7-166, 8-207, 9-252, 10-287, 11-333
clearance 1-10
connecting ESD wrist strap to 5-118
connecting to ground 6-143, 7-177, 8-219, 9-263, 10-302, 11-343
dimensions 9-253
flush-mounting (19 in. rack) 6-140, 7-175, 8-216, 9-261, 10-297, 11-341
ground connection description 5-110
ground connection procedure 5-105, 5-106, 6-138, 6-144, 7-173, 7-178, 8-214, 8-219, 9-259, 9-264, 10-294, 10-302, 11-338, 11-344
non-rack installation 6-131, 7-167, 8-208, 9-253, 10-288, 11-334
preventing overheating 5-115, 7-166, 8-207, 9-252, 10-287, 11-333
rack-mounting procedures 6-134, 7-169, 8-210, 9-255, 10-291, 11-336
circuit breaker warning 11-355, 13-480
Cisco ASR1000-RP1 2-38
Cisco ASR1000-RP2 2-38
Cisco ASR 1000 Series Embedded Services Processor (ESP) 3-79
Cisco ASR 1000 Series Route Processor 2-37
Cisco ASR 1000 Series Route Processors, differences 2-38
Cisco ASR 1000 Series Router SPA Interface Processors 4-89
Cisco ASR1002
front panel 8-194
Cisco ASR1002-F, rack-mounting 9-255
Cisco ASR1002-F Router 9-241
Cisco ASR1002-F Router,front view 9-242
Cisco ASR1004
front panel 7-162
rear view 7-163
Cisco ASR1006
front panel 6-126, 9-242, 10-281
rear view 6-127, 9-243, 10-283
specifications A-487, A-491, A-494, A-500, A-503, B-505, B-507, B-508, B-509
Cisco ASR 1013 Router 10-279
Cisco Documentation DVD ii-xxviii
Cisco IOS documentation ii-xxviii
clearance chassis 1-10
coaxial cable 5-111
commands
show environment table 1-13, 1-16
show interfaces 1-9
show running-config 12-369
show startup-config 12-369
configuring
global parameters 12-368
reviewing changes 12-369
connecting
ESD wrist strap to chassis 5-118
connecting power 6-147, 7-182, 9-268, 10-305
console connector 8-222, 9-266, 11-346
console port 12-368
console port cables 6-146, 7-181, 8-222, 9-266, 10-304, 11-346
console port kit product number A-494, A-503
console port specifications A-490, A-492, A-493, A-496, A-497, A-501, A-502, B-506, B-508
CPLD field programmable upgrade 2-35
CPLD Upgrade 2-36
D
DB-25 alarm connector 2-46
DB-25 connector 2-46
DCE device 6-146, 7-181, 10-304
DC power shutdown 1-11
DC power supply
removing 13-432, 13-444, 13-452, 13-457, 13-468
dimensions and weight of ASR1002 chassis 8-207, 11-333
dimensions and weight of ASR1004 chassis 7-167
dimensions and weight of ASR1006 chassis 6-131, 10-288
dimensions and weight of chassis 9-253
dimensions of router A-487, A-491, A-495, A-500, A-504
E
electrical wiring requirements 5-110
electromagnetic interference shielding 5-116
electromagnetic pulse
Embedded USB memory 13-410
EMI 5-106
EMI, shielding 5-116
EMP, avoiding 5-112
Encryption services 3-81
environmental monitoring and reporting
description 1-10
show commands 1-12
environmental monitoring error message C-516
ESD
prevention guidelines 5-117
wrist strap 5-117
eUSB flash field-replaceable unit 13-410
exhaust air 1-10
F
faceplate 6-126, 7-162, 8-194, 9-242, 10-281
faceplates 5-106
fan failures, shutdown 1-11
Fast Ethernet Management port 1-4
Fast Ethernet Management port cables 6-146, 7-182, 10-305
front panel 6-126, 7-162, 8-194, 9-242, 10-281
G
Gigabit Ethernet ports 2-77, 6-126, 6-129, 6-130, 7-162, 7-165, 8-194, 9-242, 10-281, 10-286, 11-350, 13-475
global parameters, configuring 12-368
ground connection
procedure 5-105, 5-106, 6-138, 6-144, 7-173, 7-178, 8-214, 8-219, 9-259, 9-264, 10-294, 10-302, 11-338, 11-344
warning 5-105, 6-144, 7-178, 8-219, 9-264, 10-302, 11-344
ground wire cable lug 6-153, 10-310
H
hardware address 1-8
hardware configuration combinations 2-30
high availability hardware configurations 2-34
humidity 5-107
I
I/O panel 6-126, 7-162, 8-194, 9-242, 10-281
IDC-4XGE D-525
IDC-CHT1/E1 D-526
IDC-HD80G D-525
IDC-OC3POS D-525
installation
connecting port adapter cables 6-145, 7-181, 8-222, 9-266, 10-303, 11-346
connecting power 6-147, 7-183, 8-225, 9-268
grounding the chassis 5-105, 5-106, 6-138, 6-144, 7-173, 7-178, 8-214, 8-219, 9-259, 9-264, 10-294, 10-302, 11-338, 11-344
starting the router 12-363
installing
general guidelines 6-130, 7-166, 8-207, 9-252, 10-286, 11-333
lifting chassis 5-121
IP, router address 12-368
J
jewelry, avoiding for safety 5-101
L
LED indicators at startup C-513
LINK/ACTV (activity) 2-40
PWR (power) OK 2-40, 2-44, 3-88, 8-198, 11-330
STATUS 2-40, 2-44, 3-88, 8-198, 11-330
line cards, making connections 7-192
LINK/ACTV (activity) LED 2-40
M
management port, Fast Ethernet 1-4
messages, environmental 1-12
MIBs D-525
mode-conditioning patch cord description A-488, A-492, A-496, A-501
modem connections 6-160, 7-192, 8-239, 9-277, 10-314, 11-348
modifications to configuration, reviewing 12-369
N
Non Crypto Capable feature 3-81
NVRAM log 1-11
O
OC-3c/STM-1 POS SPA
faceplate (figure) 9-248
LEDs 9-248
online insertion and removal 2-38
overheating, monitoring 1-11
P
password, recovering lost C-519
pinouts, RJ-45 A-489, A-492, A-493, A-496, A-497, A-498, A-501, A-502, B-505, B-506, B-507
port adapter
connecting cables 6-145, 7-181, 8-222, 9-266, 10-303, 11-346
troubleshooting C-516
port pinouts, Gigabit Ethernet RJ-45 A-488, A-492, A-496, A-501
ports, Gigabit Ethernet 2-77, 6-126, 6-129, 6-130, 7-162, 7-165, 8-194, 9-242, 10-281, 10-286, 11-350, 13-475
power
connections 6-147, 7-182, 9-268, 10-305
cord 5-101
surge suppression 5-112
power distribution unit 6-152, 10-309
power subsystem for troubleshooting C-514
power supply
disabled 1-11
shutdown 1-11
power supply zone 10-306
Power Zone 0 10-285
Power Zone 1 10-285
procedures
connecting port adapter cables 6-145, 7-181, 8-222, 9-266, 10-303, 11-346
connecting power 6-147, 7-183, 8-225, 9-268
grounding the chassis 5-105, 5-106, 6-138, 6-144, 7-173, 7-178, 8-214, 8-219, 9-259, 9-264, 10-294, 10-302, 11-338, 11-344
replacing or recovering a lost password C-519
starting the router 12-363
processor shutdown 1-11
product disposal 5-103
PWR (power) OK LED 2-40, 2-44, 3-88, 8-198, 11-330
R
rack dimensions, ASR1002-F chassis 9-256
rack-mounting
front mounted 6-135, 6-137, 7-171, 7-172, 7-175, 7-177, 7-180, 8-212, 8-213, 8-216, 8-217, 8-219, 9-257, 9-258, 9-260, 9-262, 10-290, 10-293, 11-338, 11-340, 11-342, 11-343
verifying rack dimensions 6-134, 7-170, 8-211, 9-256, 10-291, 11-336
remove Cisco ASR1000-ESPs 13-421
remove Cisco ASR1000-RP1 13-374
remove Cisco ASR1000-RP2 DIMMs 13-397, 13-402, 13-407
removing a DC power supply 13-432, 13-444, 13-452, 13-457, 13-468
removing an AC power supply 13-427, 13-441, 13-448, 13-465
replace Cisco ASR1000-ESPs 13-421
replace Cisco ASR1000-RP1 13-375
replace Cisco ASR1000-RP2 DIMMs 13-398, 13-404, 13-408
replacing an AC power supply 13-428, 13-442, 13-449, 13-467
replacing or recovering a lost password C-519
reviewing changes to configuration 12-369
RJ-45, cable A-489, A-492, A-493, A-496, A-497, A-498, A-501, A-502, B-505, B-506, B-507
RJ-45 connectors 5-112
ROMmon (rom-monitor) upgrades C-516
route processor memory design 13-390
RS-232 asynchronous data 5-112
S
safety guidelines
electricity 5-119
preventing electrostatic discharge damage 5-116
sample configurations, global parameters 12-368
servicing equipment warning 11-355, 13-480
shielded cables 8-222, 9-266, 11-346
shielded Ethernet cable 8-223, 9-267, 11-346
show commands
show environment 1-12
show environment table 1-13, 1-16
show interfaces 1-9
show running-config 12-369
show startup-config 12-369
show environment command 5-115
shutdown
power supply 1-11
processor 1-11
site requirements, rack-mounting 5-114
slot/port numbers for interfaces 1-8
slot numbering
Cisco ASR1002-F Router 4-94, 4-97
Cisco ASR1002 Router 4-94
Cisco ASR1004 Router 4-92, 4-95, 4-97
Cisco ASR1006 Router 4-92, 4-95
specifications
console port A-490, A-492, A-493, A-496, A-497, A-501, A-502, B-506, B-508
dimensions A-487, A-491, A-495, A-500, A-504
Gigabit Ethernet RJ-45 port pinouts A-488, A-492, A-496, A-501
processor and memory A-488, A-492, A-501, A-504
startup system 12-363
STATUS LED 2-40, 2-44, 3-88, 8-198, 11-330
subsystems for troubleshooting power C-514
superslot 10-286
supported platforms 2-29
system management functions 1-4
T
temperature 5-107
terminal server connections 12-368
troubleshooting
port adapter C-516
power subsystem C-514
ROMmon upgrades C-516
V
verifying the equipment rack dimensions 6-134, 7-170, 8-211, 9-256, 10-291, 11-336
W
warning
chassis grounding 6-153, 7-187, 8-229, 8-231, 9-273, 10-310, 13-437, 13-446, 13-454, 13-459, 13-471
circuit breaker 11-355, 13-480
definition 5-103, 6-128, 7-161, 7-164, 8-206, 9-252, 10-285, 11-332
equipment installation ii-xxvii, 13-374
exposed DC wire 11-356, 13-481
ground connection 5-105, 6-144, 7-178, 8-219, 9-264, 10-302, 11-344
ground connection order 5-104
installation instructions 5-103
product disposal 5-103
qualified personnel 5-104
removing power from DC circuit 5-104, 11-355, 13-480
safety information 6-128, 7-161, 7-165, 8-206, 9-252, 10-285, 11-332
servicing equipment 11-355, 13-431, 13-480
trained personnel 13-374
two-person lifting 6-132, 7-168, 8-209, 9-254, 11-334
work during lightening activity 5-120