Cisco NCS 1010 and NCS 1020 Datapath Configuration Guide, IOS XR Releases 26.x.x

PDF

OMS controller

Want to summarize with AI?

Log in

This section provides details about OMS controllers created by default for Mux/Demux and breakout panels, including supported interfaces, status and parameter commands, sample outputs, and insertion loss values for supported patch panels.


When nodes with Mux/Demux panels and breakout panels are brought up, OMS controllers are created by default. The OMS controllers for the patch panels are:

Table 1. Supported interfaces

Patch panel

Port type

OMS ports

Interfaces

NCS1K-BRK-8

MPO Ports

8

oms R/S/I/8 to oms R/S/I/15

NCS1K-BRK-24

MPO Ports

8

oms R/S/I/24 to oms R/S/I/31

NCS1K-MD-32O/E-C

LC Ports

1

oms R/S/I/32

Note

R/S/I/P stands for Rack/Slot/Instance/Port.

To view the status of the OMS controller, use this command:

RP/0/RP0/CPU0:ios#show controller description

This output shows the status of the OMS controller.

Tue Apr 12 17:17:51.306 UTC

Interface                   Status          Description
--------------------------------------------------------------------------------
Och0/1/0/0                  up
Och0/1/0/1                  up
Och0/1/0/2                  up
.
.
Output snipped
.
.
Och0/1/0/29                 up
Och0/1/0/30                 up
Och0/1/0/31                 up
Oms0/1/0/32                 up
Och0/3/0/0                  up
Och0/3/0/1                  up
.
.
Output snipped
.
.
Och0/3/0/29                 up
Och0/3/0/30                 up
Och0/3/0/31                 up
Oms0/3/0/32                 up

To view the parameters of the OMS controller for the BRK-24 panel, use this command:

RP/0/RP0/CPU0:ios#show controllers oms 0/1/0/25

This output shows the parameters of the OMS controller for the BRK-24 panel.

Thu Jul 14 11:05:50.419 UTC

 Controller State: Down 

 Transport Admin State: Automatic In Service 

 LED State: Red 

         Alarm Status:
         -------------
         Detected Alarms: 
                 RX-LOS-P    

         Alarm Statistics:
         -----------------
         RX-LOS-P = 1         
         TX-POWER-FAIL-LOW = 0

         Parameter Statistics:
         ---------------------
         TX Power = -7.40 dBm 
         RX Power = -50.00 dBm

To view the parameters of the OMS controller for the Mux/Demux panel, use this command:

RP/0/RP0/CPU0:ios#show controllers oms 0/3/0/32 

This output shows the parameters of the OMS controller for the Mux/Demux panel.

Tue May 10 11:28:02.856 UTC

 Controller State: Down 

 LED State: Red 

         Alarm Status:
         -------------
         Detected Alarms: 
                 RX-LOS-P    

         Alarm Statistics:
         -----------------
         RX-LOS-P = 1          
         TX-POWER-FAIL-LOW = 0          

         Parameter Statistics:
         ---------------------
         TX Power = -50.00 dBm 
         RX Power = -50.00 dBm 

Insertion loss for each port is calculated and the power values are displayed on the OMS controller for NCS1K-BRK-8 and OCH controller for NCS1K-BRK-24. Insertion loss per port for NCS1K-BRK-24 is 5.9 dBm and NCS1K-BRK-8 is 0.6 dBm. The NCS1K-MD-32O/E-C panels have a maximum insertion loss of 6.2 dBm for the respective Mux and Demux sections.