Server Management
The following table lists the server management BIOS settings that you can configure through a BIOS policy or the default BIOS settings:
|
Name |
Description |
Supported Attributes |
|||
|---|---|---|---|---|---|
|
Versions |
Platforms |
Values |
Dependencies |
||
| Baud Rate |
What Baud rate is used for the serial port transmission speed. If you disable Console Redirection, this option is not available. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
9.6k, 19.2k, 38.4k, 57.6k, 115.2k |
This setting must match the setting on the remote terminal application. |
| CDN Control |
Consistent Device Naming allows Ethernet interfaces to be named in a consistent manner. This makes Ethernet interface names more uniform, easy to identify, and persistent when adapter or other configuration changes are made. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Enabled, Disabled |
|
| Adaptive Memory Training |
When this token is enabled, the BIOS saves the memory training results (optimized timing/voltage values) along with CPU/memory configuration information and reuses them on subsequent reboots to save boot time. The saved memory training results are used only if the reboot happens within 24 hours of the last save operation. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, B200 M6, C220 M6, C240 M6, X210c M6, C220 M7, C240 M7, X210c M7, X410c M7, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Enabled, Disabled |
|
| BIOS Techlog Level |
This option denotes the type of messages in BIOS tech log file. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Maximum, Minimum, Normal
|
|
| OptionROM Launch Optimization |
The Option ROM launch is controlled at the PCI Slot level, and is enabled by default. In configurations that consist of a large number of network controllers and storage HBAs having Option ROMs, all the Option ROMs may get launched if the PCI Slot Option ROM Control is enabled for all. However, only a subset of controllers may be used in the boot process. When this token is enabled, Option ROMs are launched only for those controllers that are present in boot policy. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Enabled, Disabled |
|
| Console Redirection |
Allows a serial port to be used for console redirection during POST and BIOS booting. After the BIOS has booted and the operating system is responsible for the server, console redirection is irrelevant and has no effect |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Disabled, COM 0, COM 1
|
If you enable this option, you also disable the display of the Quiet Boot logo screen during POST. |
| Flow Control |
Whether a handshake protocol is used for flow control. Request to Send / Clear to Send (RTS/CTS) helps to reduce frame collisions that can be introduced by a hidden terminal problem. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
None, RTC-CTS |
This setting must match the setting on the remote terminal application. |
| FRB 2 Timer |
Whether the FRB2 timer is used for recovering the system if it hangs during POST. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5 , B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7 C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Enabled, Disabled |
|
| OS Boot Watchdog Timer |
Whether the BIOS programs the watchdog timer with a predefined timeout value. If the operating system does not complete booting before the timer expires, the CIMC resets the system and an error is logged. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Enabled, Disabled |
|
| OS Boot Watchdog Timer Policy |
What action the system takes if the watchdog timer expires. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
Power-off, Reset |
|
| OS Watchdog Timer Timeout |
What timeout value the BIOS uses to configure the watchdog timer. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
5 minutes, 10 minutes, 15 minutes, 20 minutes |
|
|
Serial Mux |
Enables or disables the serial mux configuration. |
4.3(4a) and later |
C245 M6, C225 M6 |
Enabled, Disabled |
|
| Terminal Type |
What type of character formatting is used for console redirection. |
4.2(1) and later |
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5, B200 M6, C220 M6, C240 M6, X210c M6, C225 M6, C245 M6, C220 M7, C240 M7, X210c M7, X410c M7, C225 M8, C245 M8, X215c M8, C220 M8, C240 M8, X210c M8, XE1X0M8 |
PC-ANSI, VT100, VT100-PLUS, VT-UTF8 |
This setting must match the setting on the remote terminal application. |
|
GPU Direct CPU1 |
When enabled, ACS is disabled for GPUs on the specified CPU in systems using the UCXS-580P. |
6.0(1.250229) |
X210 M8, X410 M8 |
Enabled, Disabled |
|
|
GPU Direct CPU2 |
When enabled, ACS is disabled for GPUs on the specified CPU in systems using the UCXS-580P. |
6.0(1.250229) |
X210 M8, X410 M8 |
Enabled, Disabled |
|
|
GPU Direct CPU3 |
When enabled, ACS is disabled for GPUs on the specified CPU in systems using the UCXS-580P. |
6.0(1.250229) |
X210 M8, X410 M8 |
Enabled, Disabled |
|
|
GPU Direct CPU4 |
When enabled, ACS is disabled for GPUs on the specified CPU in systems using the UCXS-580P. |
6.0(1.250229) |
X210 M8, X410 M8 |
Enabled, Disabled |
|
Feedback