View individual Raman pump values and related parameter details to verify current pump power, configured pump values, and safety controls.
-
Confirm composite Raman power and individual pump measured powers.
-
Verify Raman safety control mode, OSRI status, and APR state.
-
Compare configured pump values with measured values reported by the controller.
Raman pump values and parameter statistics help you assess amplifier health and safety conditions. The controller reports alarm statistics, measured pump powers, composite power, and the configured pump values. Use this task when troubleshooting Raman-related alarms, validating pump configuration, or confirming safety lock and OSRI status.
Follow these steps to view individual Raman pump values and related parameter details.
Procedure
|
Show Raman pump values and parameter details for the OTS controller.
The entries highlighted in bold show the Raman safety/OSRI status, composite power, and the measured pump powers. The configured pump values are shown in the Configured Parameters section.
Example:
/*View Raman pump values and other parameter details*/
RP/0/RP0/CPU0:ios#show controllers ots 0/0/0/0 raman-info
Fri Apr 1 06:40:33.849 UTC
Alarm Status:
-------------
Detected Alarms: None
Alarm Statistics:
-----------------
RAMAN-AUTO-POW-RED = 0
RAMAN-1-LOW-POW = 0
RAMAN-2-LOW-POW = 0
RAMAN-3-LOW-POW = 0
RAMAN-4-LOW-POW = 0
RAMAN-5-LOW-POW = 0
RAMAN-1-HIGH-POW = 1
RAMAN-2-HIGH-POW = 0
RAMAN-3-HIGH-POW = 0
RAMAN-4-HIGH-POW = 0
RAMAN-5-HIGH-POW = 0
Parameter Statistics:
---------------------
Raman Safety Control mode = auto
Raman Osri = OFF
Raman Force Apr = OFF
Composite Raman Power = 886.60 mW
RAMAN Pump Info:
---------------------
Instance Wavelength(nm) Power(mW)
1 1424.00 257.60
2 1438.00 255.10
3 1457.00 71.60
4 1470.00 127.50
5 1495.00 170.10
Configured Parameters:
-------------
Raman Safety Control mode = auto
Raman Osri = OFF
Raman Force Apr = OFF
RAMAN Pump Info:
---------------------
Instance Power(mW)
1 45.00
2 40.00
3 40.00
4 40.00
5 35.00
|
The command displays alarm statistics, parameter statistics (including safety and OSRI state), measured individual pump powers, and configured pump values.