Install the Cisco NCS 1001 hardware according to the site bill of materials and the Cisco Optical Network Planner NFV and connection reports.
Before you begin
-
Prepare the site rack, grounding, power feeds, and fiber-management plan.
-
Install the Cisco NCS 1001 chassis in an EIA, ANSI, or ETSI 19-inch rack.
-
Prepare the Cisco NCS 1000 32-channel mux/demux patch panel.
Follow these steps to install Cisco NCS 1001 modules.
Procedure
-
Install the two power supply units.
Use either AC power supply units or DC power supply units. Do not mix AC and DC power supply units in the same chassis.
-
Connect AC or DC power to Cisco NCS 1001 according to the site power design.
-
Install the NCS1K-CNTLR2 control card with the NCS1K-SSD.
-
Install the optical modules in slots 1 through 3 according to the site design.
Supported optical modules include NCS1K-EDFA, NCS1K-PSM, and NCS1K-OTDR. For section-protected deployments, use slot 1 for the protect EDFA, slot 2 for the PSM, and slot 3 for the working EDFA.
-
Install the four NCS1K1-FAN modules in fan slots 0 through 3.
-
Install filler optical modules or filler power supply units in empty bays.
Fillers are required to maintain cooling and laser-safety compliance.
-
Install the OSC SFP pluggables on each EDFA OSC-RX and OSC-TX port.
Example pluggables include 1510 nm and 1610 nm CWDM optics, such as ONS-SC-Z3-1510 and ONS-SC-Z3-1610.
-
Optional: Install the NCS1K-OTDR module in any free slot and connect OTDR1 and OTDR2 to the OSC ports according to the design.
-
Install the required passive modules.
-
Use NCS1K-MD-32E-CE Even and NCS1K-MD-32O-CE Odd mux/demux patch panels for 32 channels each at 150 GHz spacing. Pair both panels for 64 channels at 75 GHz spacing.
-
Use the legacy N1K-MD-32E-C 32-channel Even mux/demux patch panel only for Cisco NCS 1001 deployments that do not use loopback.
-
Use the Cisco ONS 15216 4-channel OADM for low-channel-count edge sites when required by the design.
-
Connect the patch-panel COM ports to the EDFA COM-RX and COM-TX ports.
-
Connect the patch-panel inventory USB cable to a control-card USB port for automatic inventory discovery.
-
Loop the EDFA preamplifier COM-CHECK port back to the demux monitor port when COM-TX power can exceed 20 dBm.
This loopback is required for automatic power reduction and laser safety on long spans.
-
Use the Cisco Optical Network Planner NFV and connection report to complete per-site passive and fiber wiring.
The Cisco NCS 1001 hardware and passive modules are installed and ready for software bringup.