Environmental specifications

The following table shows the server's environmental specifications.

Table 1. Environmental specifications

Environment

Specification

Temperature

Ambient operating temperature

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Humidity

Ambient operating humidity

8 to 80%

Ambient nonoperating

5 to 95%

Ambient operating altitude

0 to 10,000 feet (0 to 3,048 meters)

For China, 6,562 ft (2000 m)

Ambient nonoperating

-1000 to 30,000 feet (-304 to 15,150 meters)

* The Cisco Nexus switch functions in operating temperatures of up to 40°C at sea level. For every 300 meters (1000 ft) above sea level, the maximum temperature is reduced by 1°C. For more details on environmental requirements, see the Cisco Datasheet.

Switch dimensions

The following table shows the server's switch dimensions.

Table 2. Switch dimensions

Switch

Width

Depth

Height

Cisco Nexus 9396T12C-SE1 switch

17.41 inches (44.23 cm)

18.53 inches (47.06cm)

3.4 inches (8.6 cm) (2 RU)

Switch and Module Weights and Quantities

The following table shows the server's switch and module weights and quantities.

Table 3. Switch and module weights and quantities

Component

Weight per Unit

Quantity

Cisco Nexus 9396T12C-SE1 chassis (N9396T12C-SE1)

40 lb (18.8kg)

1

Fan Module

– 2 Port-side exhaust (blue) (NXASFAN-160CFM2PE)

– 2 Port-side intake (red) (NXASFAN-160CFM2PI)

1.3 lb (0.59 kg)

1.3 lb (0.59 kg)

3

Power Supply module

– 1400-W AC port-side exhaust (blue) (NXA-PAC-1400W-PE)

– 1400-W AC port-side intake (red) (NXA-PAC-1400W-PI)

– 2000-W DC port-side intake (red) (NXA-PDC-2KW-PI)

2.64 lb (1.2 kg)

2.64 lb (1.2 kg)

2.42 lb (1.1 kg)

2 (1 for operations and 1 for redundancy)

Switch Power Input Requirements

This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions.


Note


Some power supplies have capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed here.


Table 4. Switch power input requirements
Switch Typical Power Consumption (AC or DC) Maximum Power Consumption (AC or DC) Heat Dissipation Requirement

Cisco Nexus 9396T12C-SE1

583.5 W

794 W

2763.84 BTUs per hour

Specifications for power supplies and power cords

These sections describe the 1400W AC and 2000W DC power supply specifications and the supported AC and DC power cords.

1400-W AC-input power supply specifications

This section describes the specifications of NXA-PAC-1400W-PI and NXA-PAC-1400W-PE.

Table 5. 1400-W AC power supply specifications
Property Specification

Input Voltage Range

100 VAC to 127 VAC

200 VAC to 240 VAC

Input Frequency

50 to 60 Hz

Efficiency

90% or greater (20 to 100% load)

Output Power

1,000 W/36 W

100-127 VAC

1,400 W/36 W

200-240 VAC

Redundancy Modes

1 +1

RoHS Compliance

Yes

Hot Swappable

Yes

AC power cords for 1400W AC power supply units

This table lists the specifications for the AC power cords that are available for the 1400W AC-input power supply.

Table 6. Power Cable Specifications for AC Power Supplies
Power Type Power Cord Part Number Cord Set Description

CAB-C13-C14-2M

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

CAB-C13-CBN

Cabinet jumper power cord, 250 VAC, 10 A, C14-C13 connectors, 2.3 feet (0.7 m)

Argentina

CAB-250V-10A-AR

250 V, 10 A, 8.2 feet (2.5 m)

Australia

CAB-9K10A-AU

250 VAC, 10 A, 3112 plug, 8.2 feet (2.5 m)

Brazil

CAB-250V-10A-BR

250 V, 10 A, 6.9 feet (2.1 m)

European Union

CAB-9K10A-EU

250 VAC, 10 A, CEE 7/7 plug, 8.2 feet (2.5 m)

India

CAB-IND-10A

10 A, 8.2 feet (2.5 m)

India

CAB-C13-C14-2M-IN

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

India

CAB-C13-C14-3M-IN

Power Cord Jumper, C13-C14 Connectors, 9.8 feet (3.0 m)

Israel

CAB-250V-10A-IS

250 V, 10 A, 8.2 feet (2.5 m)

Italy

CAB-9K10A-IT

250 VAC, 10 A, CEI 23-16/VII plug, 8.2 feet (2.5 m)

Japan

CAB-C13-C14-2M-JP

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

North America

CAB-9K12A-NA

125 VAC, 13 A, NEMA 5-15 plug, 8.2 feet (2.5 m)

North America

CAB-AC-L620-C13

NEMA L6-20-C13, 6.6 feet (2.0 m)

Peoples Republic of China

CAB-250V-10A-CN

250 V, 10 A, 8.2 feet (2.5 m)

South Africa

CAB-250V-10A-ID

250 V, 10 A, 8.2 feet (2.5 m)

Switzerland

CAB-9K10A-SW

250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m)

United Kingdom

CAB-9K10A-UK

250 VAC, 10 A, BS1363 plug (13 A fuse), 8.2 (2.5 m)

All except Argentina, Brazil, and Japan

NO-POWER-CORD

No power cord included with switch

2000-W DC-input power supply specifications

This section describes the specifications of NXA-PDC-2KW-PI.

Table 7. 2000-W DC Power Supply Specifications
Property Specification

Power

2000 W

Input Voltage Range

Nominal: -48 to -60 VDC

Frequency

-

Efficiency

90% or greater (20 to 100% load)

Output Power

2000W (36W standby)

Redundancy Modes

1+1

RoHS Compliance

Yes

Hot Swappable

Yes

DC power cords for 2000W DC power supply units

This table lists the specifications for the DC power cords that are available for the 2000W DC-input power supply.

Table 8. DC Power Cable Callout Table

Part ID Number

Description

Photo

NXA-PDC-2KW-PI

The 2000W DC power supply (NXA-PDC-2KW-PI) is not shipped with a connector. You must purchase the cable (PWR-2KW-DC-CBL) separately.

Regulatory Standards Compliance Specifications

This table lists the regulatory standards compliance for the switch.

Table 9. Regulatory Standards Compliance: Safety and EMC

Specification

Description

Regulatory compliance

Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC.

Safety

  • IEC 62368-1 3rd Edition

  • UL 60950-1, Second Edition

  • UL 62368-1 3rd Edition

  • AS/NZS 62368-1 3rd Edition

  • CAN/CSA-C22.2 No.60950-1-07

  • CAN/CSA-C22.2 No.62368-1-19 3rd Edition

  • CNS15598-1:2020

EMC: Emissions

  • 47 CFR Part 15:2016

  • CISPR32:2012:Ed:1

  • CISPR32:2015:Ed:2

  • CNS 15936:2016

  • EN 55032:2012

  • EN 55032:2015

  • EN 55032:2015/A11:2020

  • EN 61000-3-3:2013+A1:2019

  • EN IEC 61000-3-2:2019+A1:2020

  • EN300 386:2012:V1.6.1

  • EN300 386:2021:V2.1.23

  • ICES-003:2020:Iss:7

  • KS C 9610-3-2:2020

  • KS C 9610-3-3:2020

  • KS C 9832:2019

  • VCCI-CISPR 32:2016

EMC: Immunity

  • CISPR24:2010+A1:2015

  • CISPR35:2016:Ed:1

  • EN 55035:2017

  • EN 55035:2017/A11:2020

  • EN IEC61000-6-1:2019

  • EN300 386:2012:V1.6.1

  • EN300 386:2021:V2.1.23

  • EN61000-6-1:2007

  • EN61000-6-2:2005

  • EN61000-6-2:2019

  • IEC61000-6-1:2016:Ed:3

  • IEC61000-6-2:2016:Ed:3

  • KS C 9835:2019

RoHS

The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors.