Lists the show commands that you can use for PTP and provides examples of their output.
This reference lists the show commands that you can use for PTP and examples of their output.
-
show PTP clock
switch#show ptp clock PTP CLOCK INFO PTP Device Type: End to End transparent clock - Multiple Vlan PTP Device Profile: Default Profile Clock Identity: 0x68:C8:EB:FF:FE:0:25:C0 Clock Domain: 0 Number of PTP ports: 10 Time Transfer: Linear Filter Offset From Master(ns): 0 Mean Path Delay(ns): 0 TTL Value: 1 DSCP Value for Event Messages: 59 DSCP Value for General Messages: 47 Delay Mechanism: End to End Local clock time: 21:38:35 UTC Mar 21 2023 -
show PTP parent
switch#show ptp parent PTP PARENT PROPERTIES Local Clock: Clock Identity: 0xC:75:BD:FF:FE:C8:66:80 Local Port Number: 1 Parent Clock: Parent Clock Identity: 0x0:0:0:0:0:0:0:1 Parent Port Number: 1 Observed Parent Offset (log variance): N/A Observed Parent Clock Phase Change Rate: N/A Grandmaster Clock: Grandmaster Clock Identity: 0x0:0:0:0:0:0:0:1 Grandmaster Clock Quality: Class: 6 Accuracy: Within 25ns Offset (log variance): 0 Priority1: 128 Priority2: 128 -
show PTP port gigabitEthernet 1/1
switch#show ptp port gigabitEthernet 1/1 PTP PORT DATASET: GigabitEthernet1/5 Port identity: clock identity: 0xC:75:BD:FF:FE:C8:66:80 Port identity: port number: 1 PTP version: 2 Port state FAULTY: FALSE Sync fault limit: 500000 Port PTP VLAN Id: 200 -
show PTP port gigabitEthernet 2/3
switch#show ptp port gigabitEthernet 2/3 PTP PORT DATASET: GigabitEthernet2/3 Port identity: clock identity: 0xC:75:BD:FF:FE:C8:66:80 Port identity: port number: 13 PTP version: 2 Port state FAULTY: FALSE Sync fault limit: 500000 Port VLAN Id: 20 Rogue master block: False -
show run int gigabitEthernet 2/3
switch#show run int gigabitEthernet 2/3 Building configuration... Current configuration : 157 bytes ! interface GigabitEthernet2/3 switchport trunk native vlan 10 switchport trunk allowed vlan 10,20,30 switchport mode trunk ptp vlan 20 dlr ring 1 end