Server Specifications
This appendix lists the physical, environmental, and power specifications for the server.
Physical Specifications
The following table lists the physical specifications for the server versions.
Description |
Specification |
Height |
3.42 in. (86.9 mm) |
Width |
16.9 in. (429.3 mm) |
Depth (length) |
Server only: 30.5 in. (775 mm) Server with slide rail: 30.5 in. (775 mm) Server with bezel: 31.5 in. (800 mm) |
Server weight |
|
Environmental Specifications
As a Class A2 product, the server has the following environmental specifications.
Description |
Specification |
Temperature, Operating |
Dry bulb temperature of 10°C to 35°C (50°F to 95°F) Maximum temperature change of 20°C (36°F) per hour (a temperature change within a specified period of time and not a rate of change) Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, Extended Operating |
5°C to 40°C (41°F to 104°F) with no direct sunlight Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, non-operating (when the server is stored or transported) |
Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F) |
Humidity (RH), operating |
10% to 90% and 28°C (82.4°F) maximum dew-point temperature, non-condensing environment Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity |
Humidity (RH), non-operating (when the server is stored or transported) |
5% to 93% relative humidity, non-condensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range. |
Altitude, operating |
A maximum elevation of 3050 meters (10,006 feet) |
Altitude, non-operating (when the server is stored or transported) |
An elevation of 0 to 12,000 meters (39,370 feet) |
Maximum Operating Duration |
Unlimited |
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |