Configuring Volume Metering
Follow the procedure given below to configure volume metering:
Procedure
| Command or Action | Purpose | |
|---|---|---|
|
Step 1 |
configure terminal Example:
|
Enters global configuration mode. |
|
Step 2 |
ap profile profile-name Example:
|
Configures an AP profile and enters ap profile configuration mode. |
|
Step 3 |
dot11 24ghz reporting-interval reporting-interval Example:
|
Configures the dot11 parameters. |
|
Step 4 |
dot11 5ghz reporting-interval reporting-interval Example:
|
Configures the dot11 parameters. |
|
Step 5 |
exit Example:
|
Returns to global configuration mode. |
|
Step 6 |
aaa accounting update periodic interval-in-minutes Example:
|
Sets the time interval (in minutes) at which the controller sends interim accounting updates of the client to the RADIUS server. |
|
Step 7 |
exit Example:
|
Exits configuration mode and returns to privileged EXEC mode. |
Feedback