Unified Computing Systems

Diagnostics

Environment

Switch Diagnostics / Environment / Syslogs

Cisco UCS C-Series Rack-Mount Servers

Diagnostics

Environment

Cisco Unified Communications Manager (CUCM)

Environment

Performance

Diagnostics

ASR 1000

Syslogs

Diagnostics

Environment

ASR 5000

Diagnostics

Environment

ASR 9000

Environment

Syslogs

ASA 5500

Diagnostics

Environment

Syslogs

Catalyst 2000/3000

Diagnostics

Environment

Syslogs

Catalyst 4500 and 4900

Diagnostics

Environment

Syslogs

Catalyst 6500 and 7600

Diagnostics

Environment

Syslogs

Error Counters - Register Name

Catalyst 7200 and 7300

Environment

Syslogs

Carrier Routing System (CRS)

Syslogs

GSR 12000

Environment

Syslogs

ISR Series

Environment

Syslogs

MDS 9000

Diagnostics

Environment

Syslogs

Nexus 7000

Diagnostics

Environment

Syslogs

Nexus 5000 and FEX

N5K Diagnostics

N5K Environment

N5K Syslogs

FEX Diagnostics

FEX Environment

Nexus 4000

Diagnostics

Syslogs

Environment

Nexus 3000

Diagnostics

Environment

Syslogs

UBR

Syslogs

Generic Syslogs

Syslogs


Monitoring Details for Cisco SMARTnet Service


Overview

Cisco® Smart Call Home is an award-winning, embedded support feature available in a broad range of Cisco products. Smart Call Home enabled devices continuously perform proactive diagnostics on their own components to provide real-time alerts and remediation advice when an issue is detected. Spend less time monitoring your network. Speed issue resolution. Gain automated access to the expertise and knowledge of our industry-leading technical support engineers. Rely on Smart Call Home to help you achieve higher network availability and increased operational efficiency.

Cisco SMARTnet® with Smart Call Home includes embedded diagnostics for the Cisco Unified Computing System, Cisco Nexus® Series Switches, and Cisco Integrated Services Routers (ISR), to name a few. This offers an important benefit to your converged network by identifying and resolving problems more quickly, more accurately, and with fewer resources. Spend less time troubleshooting, experience a speedier resolution to network issues, and gain higher network availability.

For additional resources for Smart Call Home, please see the Technical Support Resources section of this document.

Cisco.com Technical Support Resources for Users of Smart Call Home

The Cisco website offers a full range of online resources to help you use Smart Call Home. Please be sure to visit the award-wiNing support website and support community.

Visit the Smart Call Home Product Page for Smart Call Home Information

The Smart Call Home product page on Cisco.com is your starting point for learning about and using Smart Call Home. You can see which Cisco products support Smart Call Home and find links to technical content that will help you design, configure, maintain, troubleshoot and optimize your network with Smart Call Home.

Visit the Cisco Support Website for Smart Call Home Technical Resources

The Cisco Support Website is your comprehensive base of technical knowledge and tools to help you design, operate and troubleshoot your Smart Call Home products and technologies. The website offers robust features that enable you to:

Find technical content

Explore the library of 90,000+ documents (like the Smart Call Home User Guide) and use troubleshooting tools to diagnose and resolve technical issues quickly

Personalize your support

Customize the My Cisco web portal to be your central hub for viewing modular information on your products, notifications, Service Requests, and more

Download software

Find your software and the related product information from one location; save time by storing your software choices in the download cart

Use the Cisco Support Community for Technical Questions on Smart Call Home

Join the Cisco Support Community to learn more about Smart Call Home by interacting with networking peers and experts worldwide. The community offers a variety of resources that help you:

Connect with peers

Ask questions, get answers and share insights in the discussion forums (such as the Network Infrastructure forum)

Learn from Cisco experts

Learn about specific networking topics via online Ask the Expert discussions, interactive webinars and archived sessions; or explore expert blogs and videos (like Smart Call Home Configuration on UCS)

Share knowledge

Collaborate with peers to post wiki content, and share documents through social media outlets like Facebook or Twitter

Call or Email the Smart Services Bureau for Technical Questions on Smart Call Home

Smart Call Home customers can contact the Smart Services Bureau for help with registration, device configuration, help navigating the Smart Call Home portal, or any other assistance needed while using Smart Call Home. This resource is included with the service and available globally, 24 hours per day, 5 days per week.

Abbreviations

Product Name
Abbreviation
CAT6500
Catalyst 6500 Series Switches
CAT7600

Catalyst 7600 Series Switches

Nexus 5000

Nexus 5000 Series Switches

Nexus 7000

Nexus 7000 Series Switches

MDS9000

Multiservice Modular Switch

UCS 6100 SAM

Unified Computing System

ASR 1000

Aggregation Services Routers

ISR Series

Integrated Services Routers

ASA

Adaptive Security Appliance

UBR7000

Universal Broadband Router

GSR 12000

Gigabyte Switch Router

CRS-1

Carrier Routing System

CUCM

Cisco Unified Communications Manager


Monitoring Details by Product

The following table provides a quick look at the types of alarms for devices with Smart Call Home. The additional tables that follow provide specific details for each diagnostic, environmental, and syslog alarm, by device. For navigational convenience, those tables are linked to the product names in the first table.

Product
Minimum Version of Smart Call Home
Supported OS
Number of alarms per type
Alarm
Report
Proactive alarms embedded in listed Cisco devices covered by SMARTnet with Smart Call Home.
Unified Computing Systems (UCSM and switch)

3.0

NX OS 4.0

UCS OS 1.0

UCSM:
Diagnostics - 32 Environment - 20
Switch:
Diagnostics - 9
Environment - 6
Syslogs - 4 (Severity 4=4)

Y

Y

3.2

UCS 1.4(2b)

Diagnostics - 10 Environment - 5

Y

Y

Cisco Unified Communications Manager (CUCM)

3.2

CUCM 8.2

Diagnostics - 3
Environment - 1 Performance - 8

Y

Y

ASR 1000

3.1

2.6.0

Diagnostics - 18 Environment - 7
Syslogs - 40 (Severity 0=40)

Y

Y

3.2

12.0

Diagnostics - 36 Environment - 16

Y

Y

3.2

IOS XR 4.1.0

Environment - 11
Syslogs - 230

Y

Y

3.1

8.2(2)

Diagnostics - 41 Environment - 30
Syslogs - 1 (Severity 5=1)

Y

Y

3.2

IOS 12.2(58)SE

Diagnostics - 7
Environment - 7
Syslogs - 44

Y

Y

3.0

12.2(52)SG

Diagnostics - 7
Environment - 14
Syslogs - 56

Y

Y

2.1

Catalyst 6500=12.2(33)SXH Catalyst 7600=12.2(33)SRC

GOLD - 69(
Boot-up - 30
On-Demand - 10
Online Health - 29 )
Error Counter - 158 Environment - 47
Syslogs - 371
Error Counters - Register Names=153

Y

Y

3.0

12.4(24)T

Environment - 14
Syslogs - 25

Y

Y

3.2

IOS-XR

Syslogs - 187

Y

Y

3.2

IOS-XR 4.1.0

Environment - 27
Syslogs - 187

Y

Y

3.1

IOS 15.1(1)T

Environment - 59
Syslogs - 91

Y

Y

2.3

NX OS 4.1.1SAN OS 1.0

Diagnostics - 14Environment - 7S
yslogs - 104

Y

Y

2.2

NXOS 4.0

GOLD - 17
Diagnostics - 6
Environment - 8
Syslogs - 4 (Severity 4=4)

Y

Y

2.2

Nexus 5000 = NX OS 4.0 Nexus 2000 = NX OS 4.1(2)E1(1) Nexus 5000:

Diagnostics - 9 Environment - 6
Syslogs - 4 (Severity 4=4)
Nexus 2000 (FEX): Diagnostics - 4
Environment - 10

Y

Y- Nexus 5000N - Nexus 2000 (FEX)

Nexus 4000

3.1

NX OS 4.1(2)E1(1)

Diagnostics - 5
Environment - 3
Syslogs - 4

Y

Y

 
NX OS

Diagnostics - 13
Environment - 7S
yslogs - 4

Y

Y

UBR

12.2(33)SE UBR

Syslogs - 92

Y

Y

Generic Syslogs

 

All IOS

Syslogs - 74

Y

Y


Unified Computing Systems

Diagnostics

Environment

Switch Diagnostics / Environment / Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

sam:dme:fltMemoryUnitInoperable - The DIMM id/id on server chassisld/slotld is inoperable.

Y

Y

Diagnostics

sam:dme: fltProcessorUnitInoperable - The CPU on the Server Blade has failed.

Y

Y

Diagnostics

sam:dme: fltComputePhysicalInoperable - A compute server has become inoperable or has lost all communications with UCS Manager.

Y

Y

Diagnostics

sam:dme:fltComputePhysicalIdentityUnestablishable - The Server [ID] cannot establish identity because of an illegal FRU. This fault typically occurs because Cisco UCS Manager has detected an unsupported server or CPU.

Y

Y

Diagnostics

sam:dme:fltComputePhysicalBiosPostTimeout - The Server [ID] BIOS failed power-on-self-test due to bios-post-timeout.

Y

Y

Diagnostics

sam:dme:fltEquipmentIOCardIdentity - The side fabric extender chassisld/id has a malformed FRU and its identity could not be established.

Y

Y

Diagnostics

sam:dme:fltComputeBladeBiosPostTimeout - The Server chassisId/slotId (service profile assignedToDn) BIOS failed power-on self test due to bios-post-timeout .

Y

Y

Diagnostics

sam:dme:fltEquipmentChassisIdentity - The Chassis id has a mismatch between FRU identity reported by the Fabric IntercoNect against the FRU identity reported by the Chassis Management Controller.

Y

Y

Diagnostics

sam:dme:fltEquipmentFanModuleIdentity - The Fan Module id/tray-id has a malformed FRU ID and its identity could not be established.

Y

Y

Diagnostics

sam:dme:fltEquipmentPsuIdentity - The Power supply id on chassis id has a malformed FRU ID and its identity could not be established.

Y

Y

Diagnostics

sam:dme:fltAdaptorUnitAdaptorReachability - Adapter ID on Server ID is unreachable. Cisco UCS cannot access the adapter.

Y

N

Diagnostics

sam:dme:fltComputeBladeAssignedInaccessible - Server ID inaccessible.

Y

Y

Diagnostics

sam:dme:fltComputeBladeUnassignedInaccessible - Server ID is inaccessible.

Y

Y

Diagnostics

sam:dme:fltEquipmentChassisInoperable

Y

Y

Diagnostics

sam:dme:fltEquipmentIOCardInaccessible

Y

Y

Diagnostics

sam:dme:fltEquipmentIOCardPost-failure

Y

Y

Diagnostics

sam:dme:fltNetworkElementInoperable

Y

Y

Diagnostics

sam:dme:fltMgmtEntityDegraded

Y

Y

Diagnostics

sam:dme:fltMgmtEntityDown

Y

Y

Diagnostics

sam:dme:fltMgmtEntityElection-failure

Y

Y

Diagnostics

sam:dme:fltMgmtEntityManagement-services-failure

Y

Y

Diagnostics

sam:dme: fltMgmtEntityManagement-services-unresponsive

Y

Y

Diagnostics

sam:dme:fltMgmtEntityVersion-incompatible

Y

Y

Diagnostics

sam:dme:fltLsServerConfigFailure

Y

Y

Diagnostics

sam:dme:fltLsServerAssociationFailed

Y

N

Diagnostics

sam:dme: fltMemoryUnitDegraded

Y

Y

Diagnostics

sam:dme:fltPortPIoLink-down

Y

N

Diagnostics

sam:dme: fltPortPIoHardware-failure

Y

N

Diagnostics

sam:dme:fltPortPIoFailed

Y

N

Diagnostics

sam:dme: fltStorageRaidBatteryInoperable

Y

Y

Diagnostics

sam:dme: fltComputeRtcBatteryInoperable

Y

N

Diagnostics

sam:dme: fltEquipmentChassisSeeprom-inoperable

Y

Y

Diagnostics

sam:dme: fltExtmgmtIfMgmtifdown

Y

Y


Other Related Links

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

sam:dme: fltComputeBoardPowerError

Y

Y

Environment

sam:dme: fltComputePhysicalPowerProblem

Y

Y

Environment

sam:dme: fltEquipmentFanDegraded

Y

N

Environment

sam:dme: fltLicenseInstanceGracePeriodWarning7

Y

N

Environment

sam:dme:fltEquipmentChassisThermalThresholdCritical - The Temperature on chassis id is either at a upper-critical or at a lower-critical state.

Y

N

Environment

sam:dme:fltEquipmentChassisThermalThresholdNonRecoverable - The Temperature on chassis id is either at a upper-non-recoverable or at a lower-non-recoverable state.

Y

Y

Environment

sam:dme:fltEquipmentFanInoperable - The Fan id on module id/tray-id is inoperable.

Y

Y

Environment

sam:dme: fltEquipmentPsuInoperable - The system lost one of the four power supplies.

Y

Y

Environment

sam:dme: fltEquipmentIOCardThermal - The side fabric extender chassisId/id reported a thermal-problem on the Fabric Extender I/O module.

Y

N

Environment

sam:dme: fltEquipmentPsuThermalThresholdCritical - This message indicates a potential overheating in the power- supply unit. If the system has four power supplies then the system will operate on reduced capacity.

Y

N

Environment

sam:dme: fltEquipmentPsuThermalThresholdNonRecoverable - The Power supply id in chassis id temperature has reached either an upper-non-recoverable or a lower-non-recoverable state.

Y

Y

Environment

sam:dme: fltEquipmentPsuVoltageThresholdCritical - The power supply is currently operational but might fail if this condition persists.

Y

N

Environment

sam:dme: fltEquipmentPsuVoltageThresholdNonRecoverable - Power supply id has failed. If there is not enough power available, Server Blades may not power up, or will be shut down if previously powered.

Y

Y

Environment

sam:dme: fltMemoryUnitThermalThresholdCritical - The Memory unit id/id on chassis chassisId/slotId temperature has reached either an upper-critical or a lower-critical state.The Cooling algorithm is supposed to speed up to cool the blade.

Y

N

Environment

sam:dme: fltMemoryUnitThermalThresholdNonRecoverable - The Memory unit id/id on chassis chassisId/slotId temperature has reached either an upper-non-recoverable or a lower-non-recoverable state.

Y

Y

Environment

sam:dme:fltProcessorUnitThermalThresholdCritical - The processer may be reaching an overheated condition.

Y

N

Environment

sam:dme: fltProcessorUnitThermalThresholdNonRecoverable - The CPU id on chassis chassisId/slotId temperature has reached either an upper-non-recoverable or a lower-non-recoverable state. The processor will shutdown to protect itself.

Y

Y

Environment

sam:dme:fltEquipmentChassisPowerProblem

Y

Y

Environment

sam:dme:fltPsuPowerSupplyProblem

Y

N


Environment

Other Related Links

Diagnostics

Switch Diagnostics / Environment / Syslogs

Switch Diagnostics / Environment / Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Switch Diagnostics

TestFabricPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring. The system has shut down the affected ports.

Y

Y

Switch Diagnostics

TestForwardingEngine - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring. The system has shut down the affected ports.

Y

Y

Switch Diagnostics

TestForwardingEnginePort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring. The system has shut down the affected ports.

Y

Y

Switch Diagnostics

TestFrontPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring. The system has shut down the affected ports.

Y

Y

Switch Diagnostics

TestInbandPort - Inband CoNectivity to switch CPU is experiencing failure.

Y

Y

Switch Diagnostics

TestFabricEngine - Fabric ASIC has reported major failure. CoNectivity among all ports depends on Fabric ASIC.

Y

Y

Switch Diagnostics

TestSPROM - The Module (module #) caNot be brought online as the module type is unidentified.

Y

Y

Switch Diagnostics

TestOBFL - The Onboard Fault Logging flash itself has failed.

Y

Y

Switch Diagnostics

TestLED - LED control is done via the same transport mechanism to control other key components on a module. If LED control fails, it is likely that there will be other failures.

Y

N

Switch Environment

Temperature Alarm - The Temperature of device has exceeded major\minor threshold value.

Y

N

Switch Environment

PowerSupplyFailure - The device is currently working with only one power-supply unit.

Y

Y

Switch Environment

TEMPERATURE_ALARM --- Sensor - An access failure to Temperature Sensor is recorded on the device.

Y

Y

Switch Environment

TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm - Status of system and power supply fans.

Y

N

Switch Environment

Multiple fans missing or failed - The device recorded an alarm due to multiple fan failure.

Y

N

Switch Environment

One fan missing or failed - The device recorded an alarm due to a single fan failure / missing.

Y

N

Switch Syslogs

No license installed for feature, is on grace license, will expire in D H - The feature will be disabled on expiry of the grace period.

Y

N

Switch Syslogs

License for feature, will expire in H M - The evaluation license installed for the <package> will expire in <show_license_usage:comments> and will be disabled soon.

Y

N

Switch Syslogs

License has expired for feature - The evaluation license installed for the <feature> has expired and is disabled.

Y

N

Switch Syslogs

License file is missing for feature - The previously installed permanent license file for <feature_name> is missing from the device configuration storage. This feature will be disabled.

Y

N


Other Related Links

Environment

Diagnostics

Cisco UCS C-Series Rack-Mount Servers

Diagnostics

Environment

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostic

sam:dme:fltMemoryUnitInoperable: The DIMM id/id on server chassisId/slotId is inoperable.

Y

Y

Diagnostic

sam:dme: fltProcessorUnitInoperable: The Processor id on Server id is inoperable. The CPU on the Server has failed.

Y

Y

Diagnostic

sam:dme: fltComputePhysicalInoperable: The Server Id (profile assignedToDn) is inoperable.

Y

Y

Diagnostic

sam:dme:fltComputePhysicalIdentityUnestablishable: The Server Id (profile assignedToDn) cannot establish identity because of an illegal-FRU.

Y

Y

Diagnostic

sam:dme:fltComputePhysicalBiosPostTimeout: The Server Id (service profile assignedToDn) BIOS failed power-on self test due to bios-post-timeout.

Y

Y

Diagnostic

sam: dme:fltAdaptorUnitAdaptorReachability: Adapter id on Server id is unreachable.

Y

N

Diagnostic

sam:dme:fltComputePhysicalAssignedInaccessible: Server Id inaccessible.

Y

Y

Diagnostic

sam:dme:fltComputePhysicalUnassignedInaccessible: Server Id (no profile) is inaccessible.

Y

N

Diagnostic

sam:dme:fltLsServerConfigFailure: Service profile name configuration failed.

Y

N

Diagnostic

sam:dme:fltLsServerAssociationFailed: Service profile name association failed. Service profile could not be associated with the server.

Y

N


Related Links

Environment

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

sam:dme: fltMemoryUnitThermalThresholdCritical: The temperature, on memory unit id/id on server id, has reached either an upper-critical or a lower-critical state.

Y

N

Environment

sam:dme: fltMemoryUnitThermalThresholdNonRecoverable: The temperature, on memory unit id/id on server id, has reached either an upper-non-recoverable or a lower-non-recoverable state.

Y

Y

Environment

sam:dme:fltProcessorUnitThermalThresholdCritical: The host side of the Server will be shutdown automatically if the temperature of the processor reaches the non-recoverable threshold.

Y

N

Environment

sam:dme: fltProcessorUnitThermalThresholdNonRecoverable: The temperature, on CPU Id on server Id, has reached either an upper-non-recoverable, or a lower-non-recoverable state. The processor will shutdown to protect itself.

Y

Y

Environment

sam:dme:fltComputePhysicalThermalProblem: The server Id has reported thermal-problem operational status. This fault typically occurs when the server thermal sensors have detected a problem.

Y

N


Related Link

Environment

Cisco Unified Communications Manager (CUCM)

Diagnostics

Environment

Performance

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

HardwareFailure: A hardware failure event (disk drive, power suppy, others) has occurred.

Y

N


Diagnostics

Performance

Performance

Alarm Type
Alarm message information
Notify
Create Service Request
Performance

CPUPegging: CPU usage is monitored based on configured thresholds. Alert is generated if threshold exceeded.

Y

N

Performance

LowAvailableVirtualMemory: Virtual memory is low.

Y

N

Performance

LowSwapPartitionAvailableDiskSpace: Available disk space on swap partition is low.

Y

N

Performance

CallProcessingNodeCPUPegging: Percentage of CPU load on a call processing server exceeds the configured percentage for the configured time.

Y

N

Performance

CodeYellow: The AverageExpectedDelay counter represents the current average expected delay to handle any incoming message. If the value exceeds the value that is specified in Code Yellow Entry Latency service parameter, the Code Yellow alarm is generated.

Y

N

Performance

LowActivePartitionAvailableDiskSpace: The percentage of available disk space on the active partition is lower than the configured value.

Y

N

Performance

MediaListExhausted: The number of MediaListExhausted events exceeds the configured threshold during the configured time interval.

Y

N

Performance

RouteListExhausted: The number of RouteListExhausted events exceeds the configured threshold during the configured time interval.

Y

N


Diagnostics

Environment

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics
CoreDumpFileFound: A core dump file exists in the system.
Y
N
Diagnostics

CriticalServiceDown: The service status equals down.

Y

N

Diagnostics

DBReplicationFailure: Indicates a failure in IDS replication and requires database administration intervention.

Y

N


Diagnostics

ASR 1000

Diagnostics

Environment

Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

%CMCC-0-CPLD_INITIALIZATION: The SIP CPLD has failed initialization - A Session Initiation Protocol (SIP) Complex Programmable Logic Device (CPLD) failed to initialize.

Y

N

Syslogs

%CMCC-0-CPLD_IOCTL : A CPLD driver I/O control has failed because [chars] - A complex programmable logic device (CPLD) I/O driver control has failed.

 

Y

Syslogs

%CMCC-0-SERDES_INITIALIZATION : The SIP Serial Bridge ASIC has failed initialization because [chars] - The Session Initiation Protocol (SIP) serial bridge ASIC failed to initialize.

Y

N

Syslogs

%CMCC-0-SERDES_IOCTL : A Serial Bridge driver I/O control has failed because [chars] - A Serial Bridge driver I/O control has failed.

Y

N

Syslogs

%CMCC-0-HT_INITIALIZATION : The SIP HyperTransport has failed initialization because [chars] - SIP HyperTransport has failed.

Y

N

Syslogs

%CMCC-0-HT_IOCTL : A SIP HyperTransport driver I/O control has failed because [chars] - A physical layer interface module (PLIM) HyperTransport (HT) driver I/O has failed.

Y

N

Syslogs

%CMCC-0-PLIM_INITIALIZATION : The PLIM has failed initialization because [chars] - The physical layer interface module (PLIM) failed to initialize.

Y

N

Syslogs

%CMCC-0-HTDP_ENABLE : The HTDP initialization has failed because [chars] - The Hypertransort datapath (HTDP) failed to initialize.

Y

N

Syslogs

%CMCC-0-CPLD_INTR_ENABLE : The CPLD initialization has failed because [chars] - The Complex Programmable Logic Devices (CPLD) interrupted enable failed to initialize.

Y

N

Syslogs

%CMCC-0-PLIM_IOCTL : A PLIM driver I/O control has failed because [chars] - A physical layer interface module (PLIM) driver I/O has failed.

Y

N

Syslogs

%CMCC-0-PLIM_HALT : A PLIM driver has critical error [chars], [int], param [int] param [int] - A physical layer interface module (PLIM) HyperTransport (HT) driver I/O has failed.

Y

N

Syslogs

%CMCC-0-CHASSIS_TYPE : The chassis type [chars] is invalid - The system has detected an invalid chassis type.

Y

N

Syslogs

%CMCC-0-CHASFS_OBJECT_CREATE : Failed to create chassis filesystem object [chars] because [chars] - The system failed to create a chassis filesystem object.

Y

N

Syslogs

%CMCC-0-CHASFS_PROPERTY_CREATE : Failed to create chassis filesystem object [chars] property [chars] because [chars].

Y

N

Syslogs

%CMCC-0-CHASFS_PROPERTY_GET : Failed to read chassis filesystem object [chars] property [chars] because [chars] - The system failed to create a chassis filesystem object.

Y

N

Syslogs

%CMCC-0-CHASFS_PROPERTY_SET : Failed to write chassis filesystem object [chars] property [chars] because [chars] - The system failed to read a chassis file system object property.

Y

N

Syslogs

%CMCC-0-CHASFS_OBJECT_WATCH : Failed to watch chassis filesystem object [chars] because [chars] - Failed to watch a chassis filesystem object.

Y

N

Syslogs

%CMCC-0-CHASFS_OBJECT_NOT_PRESENT : Expected chassis filesystem object [chars][chars] not present - The system was unable to find an expected chassis filesystem object.

Y

N

Syslogs

%CMCC-0-CHASFS_PROPERTY_NOT_PRESENT : Expected chassis filesystem object [chars] property [chars] not present - The system caNot locate a chassis filesystem object property.

Y

N

Syslogs

%CMCC-0-CHASFS_LOCATION_TRANSLATE : Failed to translate a location to a chasfs object name because [chars] - The system failed to translate a data sensor location to the chassis filesystem (CHASFS) module.

Y

N

Syslogs

%CMCC-0-PEER_INVALID - An invalid state occurred in a peer table entry.

Y

N

Syslogs

%CMCC-0-UIPEER_CREATE : Failed to create user interface peer.

Y

N

Syslogs

%CMCC-0-SERVICES_INITIALIZATION : Failed to initialize general application services because [chars].

Y

N

Syslogs

%CMCC-0-IPC_INITIALIZATION : IPC initialization failed because [chars].

Y

N

Syslogs

%CMCC-0-IPC_CONECT_MASTER : IPC coNection to the active RP failed because [chars].

Y

N

Syslogs

%CMCC-0-IPC_CONECTION_INVALID : An IPC coNection has invalid state.

Y

N

Syslogs

%CMFP-0-SPI4_MUX_HALT : SPI4 MUX driver has detected a critical error [chars].

Y

N

Syslogs

%CMRP-0-CPLD_INITIALIZATION : The RP CPLD has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-CPLD_IOCTL : A CPLD driver I/O control has failed because [chars].

Y

N

Syslogs

%CMRP-0-I2C_INITIALIZATION : The RP I2C has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-BITS_INITIALIZATION : The RP BITS E1/T1 interface has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-WANPLL_INITIALIZATION : The RP WAN PLL has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-DDR_INITIALIZATION : The RP DDR has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-SERDES_INITIALIZATION : The RP Serial Bridge ASIC has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-SERDES_IOCTL : A Serial Bridge driver I/O control has failed because [chars].

Y

N

Syslogs

%CMRP-0-SERDES_INTERRUPT_DISPATCH : Serial Bridge interrupt dispatch error: [chars].

Y

N

Syslogs

%CMRP-0-HT_INITIALIZATION : The RP HyperTransport has failed initialization because [chars].

Y

N

Syslogs

%CMRP-0-HT_IOCTL : A RP HyperTransport driver I/O control has failed because [chars].

Y

N

Syslogs

%CMRP-0-EHSA_INITIALIZATION : EHSA initialization has failed because [chars].

Y

N

Syslogs

%CMRP-0-EHSA_STATE_GET : Failed to get EHSA state because [chars].

Y

N


Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

esi_underrun_cnt (RE =0) - This ASIC number and Register number combination indicates the elasticity FIFO was read when empty, caused by clock drift. The underrun errors indicate the number of times that the transmitter has been ruNing faster than the router can handle.

Y

N

Diagnostics

esi_overrun_cnt (RE =1) - This ASIC number and Register number combination indicates the elasticity FIFO was written when already full, caused by clock drift. The overrun errors indicate the number of times that the receiver hardware was incapable of handing received data to a hardware buffer because the input rate exceeded the receiver's capability to handle the data.

Y

N

Diagnostics

esi_reframe_cnt (RE =2) - This ASIC number and Register number combination indicates that the link layer has gone from link in sync to link out of sync.

Y

N

Diagnostics

esi_disparity_cnt (RE =3) - This ASIC number and Register number combination indicates an unknown packet separator was received.

Y

N

Diagnostics

spi_rx_discard_bytes (RE =4) - This ASIC number and Register number combination indicate the count of SPI rx bytes discarded.

Y

N

Diagnostics

spi_rx_discard_pkts (RE =5) - This ASIC number and Register number combination indicate the count of SPI rx packets discarded.

Y

N

Diagnostics

spi_rx_los_cnt (RE =6) - A Count of SPI rx loss of sync errors.

Y

N

Diagnostics

spi_tx_cal_parity_err_cnt (RE =7) - A count of SPI tx cal parity errors.

Y

N

Diagnostics

in_undersize (RE =0) - This ASIC number and Register number combination points to the total frames received with a length of less than 64 octets but with a valid FCS.

Y

N

Diagnostics

in_oversize (RE =1) - This ASIC number and Register number combination points to the total frames received with a length of more than MaxSize octets but with a valid FCS.

Y

N

Diagnostics

in_fragments (RE =2) - This ASIC number and Register number combination points to the total frames received with a length of less than 64 octets but with an invalid FCS.

Y

N

Diagnostics

in_jabber (RE =3) - This ASIC number and Register number combination points to the total frames received with a length of more than MaxSize octets but with an invalid FCS.

Y

N

Diagnostics

in_rx_err (RE =4) - This ASIC number and Register number combination points to the total frames received with an RxErr signal from the PHY.

Y

N

Diagnostics

in_fcs_err (RE =5) - This ASIC number and Register number combination points to the total frames received with an CRC error not counted in InFragments, InJabber or InRxErr.

Y

N

Diagnostics

Collisions (RE =6) - This ASIC number and Register number combination points to the number of collision events seen by the MAC not including those counted in Single, Multiple, Excessive or Late.

Y

N

Diagnostics

Late (RE =7) - This ASIC number and Register number combination points to the number of times a collision is detected later than 512 bits-times into the transmission of a frame.

Y

N

Diagnostics

in_bad_octets (RE =8) - This ASIC number and Register number combination points to the sum of the lengths of all the bad Ethernet frames that were received.

Y

N

Diagnostics

out_fcs_err (RE =9) - This ASIC number and Register number combination points to the number of frames transmitted with an invalid FCS.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature Alarm - sensorcrossedthresholdmajor - Operating temperature has risen above the Critical threshold value.

Y

N

Environment

Temperature Alarm - sensorfailedmajor - A Temperature Sensor failure is recorded on the device.

Y

N

Environment

Temperature Alarm - sensorrecoveryminor - The device has recovered from an earlier temperature alarm at <Inlet on slot R0 Sensor >.

Y

N

Environment

Power Supply Failure - External power supply has failed or one PEM has failed/been removed.

Y

N

Environment

Power Supply Failure - Recovery - The device has recovered from an earlier alarm on one of the power entry modules.

Y

N

Environment

Fan failure - The router's cooling fans fan # failed.

Y

N

Environment

Fan failure - Recovery - The device has recovered from an earlier alarm on one of the fans.

Y

N


Environment

ASR 5000

Diagnostics

Environment

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

Card Locked: Triggered whenever a card is physically locked by sliding the card latch into the locked position.

Y

N

Diagnostics

Card Unlockied (for HAT): Triggered whenever a card is physically unlocked by sliding the card latch into the unlocked position.

Y

N

Diagnostics

Card Removal Cancelled (Relocked): A card is locked, unlocked, and again locked, without being pulled.

Y

N

Diagnostics

Card Ready for Removal: Indicates that a card can now safely be removed from the chassis.

Y

N

Diagnostics

Card Pulled When Not Ready: A card is physically removed from the chassis and was not ready for removal.

Y

N

Diagnostics

Card Pulled When Ready: A card is physically removed from the chassis and it was ready for removal.

Y

N

Diagnostics

Card Failed (for HAT): A card failed.

Y

Y

Diagnostics

Card Not Usable: A card is not usable due to failure, unknown type, etc.

Y

Y

Diagnostics

Card Initialized:The NPUMGR on an application card (SPC/PAC/TAC) finished initializing hardware.

Y

N

Diagnostics

Card Initialization Failed: The NPUMGR on an application card (SPC/PAC/TAC) does not finish initializing hardware within the timout period.

Y

Y

Diagnostics

Card Became Active: The card is active.

Y

N

Diagnostics

Card missing Required Daughter Card: The card is missing required daughter card.

Y

Y

Diagnostics

Card Type Invalid For Redundancy Mode: The card installed is not valid for redundancy mode.

Y

Y

Diagnostics

Card Type Invalid For Framing Mode: The card installed is not valid for framing mode that is being configured on the card.

Y

Y

Diagnostics

Card Has Entered Low Power Mode: The card has entered a low power mode.

Y

Y

Diagnostics

Card Has Left Low Power Mode: The card has recovered from an earlier error condition of low power mode.

Y

N

Diagnostics

Unsupported Card Insert: The newly inserted card is not supported on the chassis.

Y

N

Diagnostics

Unsupported Card Locked: An unsupported card is physically locked by sliding the card latch into the locked position.

Y

N

Diagnostics

Unsupported Card Unlocked: An unsupported card is phycially unlocked by sliding the card latch into the unlocked position.

Y

N

Diagnostics

Unsupported Card Ready for Removal: The unsupported card can now safely be removed from the chassis.

Y

N

Diagnostics

Unsupported Card Pulled: An unsupported card is physically removed from the chassis.

Y

N

Diagnostics

Unsupported Card Shutdown Issued: An unsupported card's administrative state is set to disabled because of a 'shutdown' command.

Y

N

Diagnostics

Warning: Card Unlocked [for CSP-Card Slot Port]: Triggered whenever a card is physically unlocked by sliding the card latch into the unlocked position.

Y

N

Diagnostics

Card Failed [for CSP]: A card has failed.

Y

Y

Diagnostics

IDEEPROM Failed: When a CSP subsystem detects an IDEEPROM failure; when it fails to read it, CSP notifies HATSYSTEM (High Availability Task - this is a software task that manages the operational state of the system).

Y

Y

Diagnostics

CPU Failed: The CPU has failed.

Y

Y

Diagnostics

Memory failed: Too many memory ECC unrecoverable errors occur. The device will automatically try to reboot the card, and if this fails, a card failure alert will be triggered.

Y

N

Diagnostics

RCC Switch Fabric Failed: The RCC VC3002 switch fabric has failed.

Y

Y

Diagnostics

FPGA Failed on a Card: A FPGA failure is detected.

Y

Y

Diagnostics

GE Switch Failed: A Gigabit Ethernet switch on the Switch Processor Card (SPC)/System Management Card (SMC) SPC or Packet Services Cards (PSC/PAC) has failed.

Y

Y

Diagnostics

Vitesse Switch Fabric Failed: The Vitesse Switch Fabric has failed on SPC or PAC.

Y

Y

Diagnostics

NPU Subsystem Failed: Network Processing Unit manager (NPUMGR) detects NPUT component failure, which leads to the NPU subsystem failure, and wants to take card recovery action. The device will automatically try to reboot the card, and if this fails, a card failure alert will be triggered.

Y

N

Diagnostics

LC Failed: NPUMGR reports that a line card failed.

Y

Y

Diagnostics

Card Failed Recovery Attempt Failed: A card failure recovery attempton High Availability Task (HAT) request by CSP fails.

Y

Y

Diagnostics

Card Error Detected: A recoverable error has occurred on a card.

Y

Y

Diagnostics

Crash: A crash has occurred in the device.

Y

Y


Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment
Temperature Recovery of a Card Completed: Temperature of a card drops to normal after an overtemp event.
Y
N
Environment

Temperature Failed: HATCPU detects a card failed because of over temperature.

Y

N

Environment

Card Temperature Under 20C Degrees: A card is experiencing an under temperature condition. The safe operating range for the chassis and its subcomponents is 0 - 55ºC. The device is powered off at 0ºC, allowed to reach equilibrium, then is powered back up.

Y

N

Environment

Card Temperature over 71C Degrees: Temperature of a card is experiencing a high temperature condition.

Y

N

Environment

Multiple Cards Over 71C Degree Temperature Failure: Multiple over temperature conditions have occurred in the chassis.

Y

N

Environment

Fan Failed: A fan failure is identified on the device.

Y

N

Environment

Fan Tray Inserted

Y

N

Environment

Fan Tray Removed

Y

N

Environment

Mismatched Power Control States: Standby HATSYSTEM power control map does not match with that on primary HATSYSTEM and overwrites its value with that of primary HATSYSTEM state.

Y

N

Environment

Power Control Failure: Any of the four power sources fluctuate beyond specified limits.

Y

N

Environment

Power Applied from Power Filter: Power is applied from a DC power filter in the chassis.

Y

N

Environment

Power Remoted from Power Filter: Power is removed from a DC power filter in the chassis.

Y

N

Environment

Card Sensor Access Failure: The sensor on a card is inaccessible. The card will be shut down by the system.

Y

N


ASR 9000

Environment

Syslogs

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment
SPA Over-Temperature: temperature exceeds normal value in Shared Port Adapter.
Y
N
Environment

SPA Overtemp Shutdown: SPA has been shut down because of over temperature

Y

Y

Environment

Chassis Overtemp: An over temperature condition is detected in the chassis.

Y

N

Environment

Card Overtemp: An over temperature condition is detected in the card.

Y

N

Environment

Card Overtemp Shutdown: The card has been shut down because of over temperature.

Y

Y

Environment

Fantray Fail: A failure in the fantray.

Y

Y

Environment

Fan Fail

Y

Y

Environment

Card Voltage Alarm: A alarm, such as temperature or voltage, occurs in the fantray.

Y

Y

Environment

Fantray Alarm: Triggered when there is an alarm in the fantray, such as temperature.

Y

Y

Environment

Fantray Comm Fail: There is a communication failure in the fantray.

Y

Y

Environment

All Fantrays Missing: The fantray is not detected or missing.

Y

Y


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog

%CMCC-0-CHASFS_LOCATION_TRANSLATE

Y

N

Syslog

%CMCC-0-CHASFS_OBJECT_CREATE

Y

N

Syslog

%CMCC-0-CHASFS_OBJECT_NOT_PRESENT

Y

N

Syslog

%CMCC-0-CHASFS_OBJECT_WATCH

Y

N

Syslog

%CMCC-0-CHASFS_PROPERTY_CREATE

Y

N

Syslog

%CMCC-0-CHASFS_PROPERTY_GET

Y

N

Syslog

%CMCC-0-CHASFS_PROPERTY_NOT_PRESENT

Y

N

Syslog

%CMCC-0-CHASFS_PROPERTY_SET

Y

N

Syslog

%CMCC-0-CHASSIS_TYPE

Y

N

Syslog

%CMCC-0-CPLD_INITIALIZATION

Y

N

Syslog

%CMCC-0-CPLD_INTR_ENABLE

Y

N

Syslog

%CMCC-0-CPLD_IOCTL

Y

N

Syslog

%CMCC-0-HT_INITIALIZATION

Y

N

Syslog

%CMCC-0-HT_IOCTL

Y

N

Syslog

%CMCC-0-HTDP_ENABLE

Y

N

Syslog

%CMCC-0-IPC_CONNECT_MASTER

Y

N

Syslog

%CMCC-0-IPC_CONNECTION_INVALID

Y

N

Syslog

%CMCC-0-IPC_INITIALIZATION

Y

N

Syslog

%CMCC-0-PEER_INVALID

Y

N

Syslog

%CMCC-0-PLIM_HALT

Y

N

Syslog

%CMCC-0-PLIM_INITIALIZATION

Y

N

Syslog

%CMCC-0-PLIM_IOCTL

Y

N

Syslog

%CMCC-0-SERDES_INITIALIZATION

Y

N

Syslog

%CMCC-0-SERDES_IOCTL

Y

N

Syslog

%CMCC-0-SERVICES_INITIALIZATION

Y

N

Syslog

%CMCC-0-UIPEER_CREATE

Y

N

Syslog

%CMFP-0-SPI4_MUX_HALT

Y

N

Syslog

%CMRP-0-BITS_INITIALIZATION

Y

N

Syslog

%CMRP-0-CPLD_INITIALIZATION

Y

N

Syslog

%CMRP-0-CPLD_IOCTL

Y

N

Syslog

%CMRP-0-DDR_INITIALIZATION

Y

N

Syslog

%CMRP-0-EHSA_INITIALIZATION

Y

N

Syslog

%CMRP-0-EHSA_STATE_GET

Y

N

Syslog

%CMRP-0-HT_INITIALIZATION

Y

N

Syslog

%CMRP-0-HT_IOCTL

Y

N

Syslog

%CMRP-0-I2C_INITIALIZATION

Y

N

Syslog

%CMRP-0-SERDES_INITIALIZATION

Y

N

Syslog

%CMRP-0-SERDES_INTERRUPT_DISPATCH

Y

N

Syslog

%CMRP-0-SERDES_IOCTL

Y

N

Syslog

%CMRP-0-WANPLL_INITIALIZATION

Y

N

Syslog

%ENVIRONMENTAL-1-ALERT Temp

N

N

Syslog

%FABRIC-FABQ-0-PRP3_FAULT_RECOVERY_ERR

Y

N

Syslog

%FABRIC-FABRICQ-1-ERR_ASIC_GENERIC

Y

N

Syslog

%FABRIC-FIA-0-ASIC_FATAL_FAULT

Y

Y

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_0

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_0

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-SUSTAINED_CRC_ERR

Y

Y

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_0

Y

N

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_1

Y

N

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_RACK_RELOAD

Y

N

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_ROUTER_RELOAD

Y

N

Syslog

%FABRIC-FSDB-0-FABRIC_LOSS_LC_RELOAD

Y

Y

Syslog

%FABRIC-FSDB-1-ERR_PLANE_CONFIG

Y

N

Syslog

%FABRIC-FSDB-1-FABRIC_UPDOWN

Y

N

Syslog

%FABRIC-FSDB-1-PLANE_UPDOWN

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_ASIC_GENERIC\[\]

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_INIT\[\]

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERROR_HW_ACCESS\[\]Error

Y

N

Syslog

%HA-HA_WD-1-ABORTING\[\]\,Aborting\.

Y

N

Syslog

%HA-HA_WD-1-CPU_HOG_5

Y

N

Syslog

%HA-HA_WD-1-CURRENT_STATE

Y

N

Syslog

%HA-HA_WD-1-DISK_ALERT

Y

N

Syslog

%HA-REDCON-1-STANDBY_NOT_READY

Y

N

Syslog

%HA-REDCON-1-STANDBY_READY

Y

N

Syslog

%INFRA-SUB_UTIL-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%IP-PLATFORM_IPV4-1-DLERR\[\]

Y

N

Syslog

%L2-ATM_RM-1-SYSDB_ERR\[\]

Y

N

Syslog

%L2-EGRESSQ_HW_DLL-3-SBE_THR

Y

Y

Syslog

%L2-ether_spa_mac_error-1-RECOVERY_FAILED

Y

N

Syslog

%L2-LC-0-TESTEMERG

Y

N

Syslog

%L2-SPA_ETHER-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%L2-VPA_8P_GE-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-BADDEVOPEN

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-INIT_FAILED

Y

N

Syslog

%MGBL-CONFIG-0-INIT_FAILURE

Y

N

Syslog

%MGBL-CONFIG-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%MGBL-TTY-0-ISSU_STDBY_CON_AVAILABLE STANDBY

Y

N

Syslog

%OS-QNET-0-EMG

Y

N

Syslog

%OS-SYSLOG-0-LOG_EMERG

Y

N

Syslog

%OS-SYSLOG-0-LOG_EMERG_OWNER_PLANE

Y

N

Syslog

%PKT_INFRA-spp-0-EMERG

Y

N

Syslog

%PLATFORM-ASM-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-ASM-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_0

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_O

Y

N

Syslog

%PLATFORM-CARD-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_A_FAILED

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_PWR_SEQ_FAILED

Y

Y

Syslog

%PLATFORM-CBC-1-SLOT_ID_CHANGE

Y

N

Syslog

%PLATFORM-CBC-1-VERSION_ERROR

Y

N

Syslog

%PLATFORM-CHP-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_BOARD_RELOAD\[\]\[\[\]\]

Y

Y

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_RELOAD_SYS\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_SHUTDOWN_BOARD\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-CIH-1-ASIC_ERROR_RELOAD_BOARD

Y

N

Syslog

%PLATFORM-COMMON-0-LC_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-COMMON-0-RSP_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700_DLL-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-EVT_INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INTR_INIT_ERROR

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK0

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK1

Y

N

Syslog

%PLATFORM-CROSSBAR-1-OUT_MEM_ERROR_LNK1

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK0

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK1

Y

N

Syslog

%PLATFORM-DIAGS-0-LC_NP_LOOPBACK_FAILED

Y

Y

Syslog

%PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED

Y

Y

Syslog

%PLATFORM-DISCOVERY-0-ERR ASIC-ERR

Y

N

Syslog

%PLATFORM-DSC-1-ERR_LOST_ALL_FABRIC_RACKS

Y

N

Syslog

%PLATFORM-ENVMON-0-CARD_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-0-CHASSIS_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-1-CANTSHUT

Y

N

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAILURE

Y

Y

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAULT

Y

Y

Syslog

%PLATFORM-ENVMON-1-FAN_REMOVE

Y

N

Syslog

%PLATFORM-ENVMON-1-PEM_REMOVE

Y

N

Syslog

%PLATFORM-ENVMON-1-SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-1-SPA_CANTSHUT

Y

Y

Syslog

%PLATFORM-ENVMON-1-SPA_SHUTDOWN

Y

Y

Syslog

%PLATFORM-FABARBITER-1-SERDES_ERROR

Y

N

Syslog

%PLATFORM-FABMGR-1-ARB_SERDES_FAIL

Y

N

Syslog

%PLATFORM-FABMGR-1-BAD_XBAR

Y

N

Syslog

%PLATFORM-FABMGR-1-PERSISTENT_SERDES_FAIL

Y

N

Syslog

%PLATFORM-FAN-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_E7_INFO

N

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_INFO

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-TW_INFO

N

N

Syslog

%PLATFORM-FFQ-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-I2C_MASTERSHIP-0-ARBITRATION_LOCK_UNAVAILABLE

Y

Y

Syslog

%PLATFORM-I2C-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_ACT_ERROR

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_PRESENT_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-0-FATAL_ERR_INTR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_PAR_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-CPU_PAR_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-DEV_VERSION_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_0

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_1

Y

N

Syslog

%PLATFORM-MCE-2-L2CACHE_ERR

Y

N

Syslog

%PLATFORM-NFEA_PAL-1-FLOWEXP_LIMIT

Y

N

Syslog

%PLATFORM-NP-0-INIT_ERR

Y

N

Syslog

%PLATFORM-NP-0-NP_INIT_FAILURE

Y

Y

Syslog

%PLATFORM-NP-0-PEX_PARITY

Y

Y

Syslog

%PLATFORM-NP-0-TOP_INACTIVITY_WATCHDOG

Y

Y

Syslog

%PLATFORM-NP-0-TOP_PERSISTANT_LOCKUP_ERROR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-0-NO_ACTIVE_RSP

Y

Y

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_DIP4

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_PROT_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_CRC_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_DELM_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_CRC_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-LBUS_PARITY_ERR

Y

N

Syslog

%PLATFORM-PFM-0-CARD_RESET_ABORTED

Y

N

Syslog

%PLATFORM-PFM-0-CARD_RESET_REQ

Y

Y

Syslog

%PLATFORM-PFM-0-GRACEFUL_CARD_RESET_TIMED_OUT

Y

N

Syslog

%PLATFORM-POWERMGR-1-POWER_MODE_WARN

Y

Y

Syslog

%PLATFORM-PRP_HW-1-NVRAM_LOW_BATTERY_ERROR

Y

Y

Syslog

%PLATFORM-PRP_HW-1-OIR_OUT

Y

N

Syslog

%PLATFORM-PSARB-1-WRONG_SLOT

Y

Y

Syslog

%PLATFORM-PWR_SUPPLY-0-FAULT

Y

N

Syslog

%PLATFORM-PWRMON-1-IDPROM_INVALID

Y

N

Syslog

%PLATFORM-PWRMON-1-ZERO_CAPACITY

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP0_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP1_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_0

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_1

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_CHAIN

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_ERR_CMD

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_INVALID_CMD

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_OFLOW

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_PROTO

Y

N

Syslog

%PLATFORM-REDDRV-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%PLATFORM-RSP_CPUCTRL-0-BOARD_SEATING_ERROR

Y

Y

Syslog

%PLATFORM-SHELFMGR-0-CHASSIS_SHUTDOWN

Y

Y

Syslog

%PLATFORM-SHELFMGR-1-ALL_FANTRAYS_OFF

Y

N

Syslog

%PLATFORM-SHELFMGR-1-BOTH_FC_REMOVED

Y

N

Syslog

%PLATFORM-SHELFMGR-1-NO_POWER_AVAIL

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-0-FATAL_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-ERP_ERROR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-MBIT_ECC_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-PARITY_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPA_FATAL_ISR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS1_ERROR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS3_ERROR

Y

N

Syslog

%PLATFORM-SYSLDR_RP-1-NODE_RELOAD_NOW

Y

N

Syslog

%PLATFORM-SYSLDR-1-PING_FAILURE

Y

N

Syslog

%PLATFORM-SYSLDR-1-PING_FAILURE_BOOT

Y

N

Syslog

%PLATFORM-SYSLDR-1-SELF_PING_FAILURE

Y

N

Syslog

%PLATFORM-TFQ-0-SW_INIT_ERR

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-ALM_EMERG

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-GRP_ALM_EMERG

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-ALM_ALERT

Y

N

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-GRP_ALM_ALERT

Y

N

Syslog

%SUBSCRIBER-DATABASE-0-INIT_FAILURE

Y

Y

Syslog

%SUBSCRIBER-DATABASE-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

CLEAR-[0-9]*-COUNTERS

N

N

Syslog

CLEAR-[0-9]*-COUNTERS

Y

N

Syslog

L2-PLIM-1-ERR_HW_THRESHOLD_RELOAD_NODE

Y

N


ASA 5500

Diagnostics

Environment

Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

Trace-back - Assertion - The device crashed due to an assertion error.Y

Y

 
Diagnostics

Trace-back - Assertion w/ block corruption - The device crashed due to block corruption.Y

Y

 
Diagnostics

Trace-back - Checkheaps - The device crashed because of memory corruption.Y

Y

 
Diagnostics

Trace-back - Page Fault - The device crashed when accessing an invalid memory address Y

Y

 
Diagnostics

Trace-back - Watchdog Timeout - The device crashed because a process was stuck, usually because of deadlock.

Y

Y

Diagnostics

Mini-Dump - ASA Crash Recovery Dump - The device recovered from an internal error.N

N

 
Diagnostics

Failover - Set by the config command: A CLI command was issued causing a failover switch from active or standby.

Y

N

Diagnostics

Failover - Failover state check: The failover state changed because the failover states of both units were not in a stable state.

N

N

Diagnostics

Failover - Failover interface become OK: The failover state changed because the failed/down interfaces are now back on-line.

N

N

Diagnostics

Failover - HELLO not heard from mate: The failover state changed because the device lost its coNections with the peer unit.

Y

N

Diagnostics

Failover - Other unit has different software version: The ASA failover pair do not have matched software images.

Y

N

Diagnostics

Failover - Other unit operating mode is different: The ASA failover pair do not have matched operating mode (one is in single mode and the other is in multiple mode).

Y

N

Diagnostics

Failover - Other unit license is different: The ASA failover pair do not have matched licenses.

Y

N

Diagnostics

Failover - Other unit chassis configuration is different: The ASA failover pair are not the same model.

Y

N

Diagnostics

Failover - Other unit card configuration is different: The ASA failover pair do not have the same software module card or interface card.

Y

N

Diagnostics

Failover - Other unit wants me Active: The "no failover active" command was issued on the peer device in order to switch the peer to standby and make this ASA become active.

Y

N

Diagnostics

Failover - Other unit wants me Standby: The "failover active" command was issued on the peer unit to switch the peer to active and make this ASA become standby.

Y

N

Diagnostics

Failover - Other unit reports that I am failed: The failover peer device did not receive the failover message because this ASA device is too busy to answer failover traffic.

Y

Y

Diagnostics

Failover - Other unit reports that it is failed: The failover peer unit experienced a hardware failure.

Y

Y

Diagnostics

Failover - Configuration mismatch: The ruNing configurations on the two ASA failover peer units are not synced.

N

N

Diagnostics

Failover - Detected an Active mate: A peer unit was detected.

N

N

Diagnostics

Failover - No Active unit found: Failover peer was not found.

N

N

Diagnostics

Failover - Recovered from communication failure: The failover pair re-established communication.

N

N

Diagnostics

Failover - Incomplete configuration synchronization: Configuration sync is not completed and configuration on the standby unit is not synchronized.

Y

N

Diagnostics

Failover - Configuration synchronization failed: Configuration synchronization failed and configuration is not able to get synced from the active unit.

Y

N

Diagnostics

Failover - Interface check: The interface check failed on this device; the interfaces were either down or failed.

Y

N

Diagnostics

Failover - ACK not received for failover message: An acknowledgement for a failover message sent by this device was not received from peer unit.

Y

N

Diagnostics

Failover - Other unit got stuck in learn state after sync: The peer unit of the failover group is stuck in config sync.

Y

N

Diagnostics

Failover - No failover cable: The failover serial cable does not exist.

Y

N

Diagnostics

Failover - HA state progression failed: The failover state transition failed.

Y

N

Diagnostics

Failover - Detect service card failure: The service card has failed on this device.

Y

N

Diagnostics

Failover - Service card in other unit has failed: The service card has failed on the peer unit of the failover group.

N

N

Diagnostics

Failover - My service card is as good as peer: The service card becomes operational, or the peer unit's service card failed.

N

N

Diagnostics

Failover - LAN Interface become un-configured: Failover LAN interface is not configured.

N

N

Diagnostics

Failover - Peer unit just reloaded: The peer unit just reloaded.

N

N

Diagnostics

Failover - Switch from Serial Cable to LAN-Based fover Switched from serial cable to LAN-based failover.

N

N

Diagnostics

Failover - Auto-Update request: The auto-update module requested the failover state change.

N

N

Diagnostics

[Primary] Failover switched from Bulk Sync to Standby Ready. Reason: No Error

N

N

Diagnostics

[Primary] Failover switched from Not Detected to Disabled. Reason: No Error

N

N

Diagnostics

[Secondary] Failover group 1 switched from Bulk Sync to Standby Ready. Reason: No Error

N

N


Environment

Alarm Type
Alarm Message Information
Notify
Create Service Request
Environment
Memory Module 1 Temperature OK: 170 C
Y
N
Environment

Memory Module 5 Voltage OK: 187 Volts

Y

N

Environment

Power Supply 2 Cooling Fan OK: 0 RPM

Y

N

Environment

Power Supply 2 Voltage OK: 139 Volts

Y

N

Environment

Mainboard 6 Voltage OK: 130 Volts

Y

N

Environment

Power Supply 2 Cooling Fan Failure Detected

Y

Y

Environment

Power Supply 2 Voltage Critical

Y

N

Environment

Mainboard 6 Voltage Critical

Y

N

Environment

Memory Module 5 Voltage Critical

Y

N

Environment

Health - Cooling Fan x Fail: Cooling fan x has failed.

Y

Y

Environment

Health - Cooling Fan x OK: Cooling fan x has been restored to normal operation.

N

N

Environment

Health - Cooling Fan Redundancy Lost: This message is accompanied by a cooling fan failure. Cooling Fan unit redundancy has been lost.

Y

Y

Environment

Health - Cooling Fan Redundancy OK: Cooling Fan redundancy has been restored.

N

N

Environment

Health - Power Supply Redundancy Lost :This message is accompanied by a power supply failure. Power supply unit redundancy has been lost.

Y

N

Environment

Health - Power Supply Redundancy OK: Power supply unit redundancy has been restored.

N

N

Environment

Health - CPU x Temperature Critical: CPU x has reached a critical temperature.

Y

Y

Environment

Health - CPU x Temperature Warm: CPU x is near the critical value, but is still within a functioning range.

Y

Y

Environment

Health - CPU x Temperature OK: CPU x has returned to normal operating temperature.

N

N

Environment

Health - Chassis x Temperature Critical: Chassis x temperature has reached a critical level.

Y

Y

Environment

Health - Chassis x Temperature Warm: Chassis x temperature is near critical value, but is still within operating range.

Y

Y

Environment

Health - Chassis x Temperature OK: Chassis x has returned to normal operating temperature.

N

N

Environment

Health - Power Supply x Temperature Critical: Power supply x has reached a critical level.

Y

Y

Environment

Health - Power Supply x Temperature Warm: Power supply x is near critical value but still within a functional range.

Y

Y

Environment

Health - Power Supply x Temperature OK: Power supply x has returned to a normal operating temperature.

N

N

Environment

Health - Power Supply x Failure Detected: Power supply x has been lost or the power supply has failed.

Y

Y

Environment

Health - Power Supply x OK: Power supply x has been restored to normal operation.

N

N

Environment

Resource - Memory Usage High: Memory usage is higher than configured threshold (default 90%).

Y

Y

Environment

Resource - Memory Usage OK: Memory usage is back to normal (default 85% or lower).

N

N

Environment

Resource - CPU Usage High: CPU usage is higher than configured threshold (default 90%).

Y

Y

Environment

Resource - CPU Usage OK: CPU usage is back to normal (default 85% or lower).

N

N


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslogs
ASA-5-711005: Traceback: This syslog message is logged on the device because of an internal software error.
N
N

Catalyst 2000/3000

Diagnostics

Environment

Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostic

TestPortAsicStackPortLoopback - The device failed the TestPortAsicStackPortLoopback test; this is a non-disruptive test.

Y

N

Diagnostic

TestPortAsicLoopback - The device failed the TEstPortAsicLoopback test; this is a disruptive on-demand test. The switch will reload after test completion.

Y

Y

Diagnostic

TestPortAsicCam - The device failed the TestPortAsicCam test; this is a disruptive on-demand test. This test will cause the switch under test to reload.

Y

Y

Diagnostic

TestPortAsicRingLoopback - The device failed the TestPortAsicRingLoopback test; this is a disruptive on-demand test. The test will cause the switch under test to reload.

Y

N

Diagnostic

TestMicRingLoopback - The device failed the TestMicRingLoopback test; this is a disruptive on-demand test. This test will cause the switch under test to reload. If the switch under test is in a stack and a test causes the switch to lose stack connectivity, the switch will reload when it rejoins the stack.

Y

N

Diagnostic

TestPOrtAsicMem - The device failed the TestPortAsicMem test; this is a disruptive on-demand test. The test will cause the switch under test to reload. If the switch under test is in a stack and a test causes the switch to lose stack connectivity, the switch will reload when it rejoins the stack.

Y

N

Diagnostic

TestInlinePwrCtlr - The device failed the TestInlinePwrCtlr test; this is a disruptive on-demand test. The test will cause the switch under test to reload. If the switch under test is in a stack and a test causes the switch to lose stack connectivity, the switch will reload when it rejoins the stack.

Y

Y


Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment
TempHigh - The operating temperature has risen above the <yellow/red> threshold value.
Y
N
Environment

CriticalTemp - The operating temperature has risen above the <yeloow/red> threshold value.

Y

N

Environment

PowerSupplyBad - The device recorded a power supply alarm.

Y

N

Environment

PowerSupplyFanBad - The device recorded an alarm on fan in the power supply.

Y

N

Environment

InlinePowerSupplyBad - The device recorded an alert condition on the power supply.

Y

N

Environment

RedundantPowerSupplyFailure - The device recorded a power supply alarm.

Y

N

Environment

FanTrayBad - The device recorded an alert condition on the fans.

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog
%PORT_SECURITY-2-PSECURE_VIOLATION_VLAN
N
N
Syslog

%SPANTREE-2-BLOCK_BPDUGUARD_VP

Y

N

Syslog

%SPANTREE_VLAN_SW-2-MAX_INSTANCE

Y

Y

Syslog

%SPANTREE-2-RECV_1Q_NON_1QTRUNK

Y

N

Syslog

%CFGMGR-1-UNABLE_TO_SEND_RUN_CFG

Y

Y

Syslog

%ACLMGR-2-NOVMR

Y

N

Syslog

%VQPCLIENT-2-TOOMANY

Y

N

Syslog

%PLATFORM_ENV-1-FRU_PS_SIGNAL_OK

Y

N

Syslog

%UDLD-0-STOPPED

Y

Y

Syslog

%PM-2-NOMEM

Y

Y

Syslog

%PM-2-VLAN_ADD

Y

N

Syslog

%SPANTREE-2-BLOCK_BPDUGUARD

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_BLOCK

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_UNBLOCK

Y

N

Syslog

%SPANTREE-2-ROOTGUARD_CONFIG_CHANGE

N

N

Syslog

%VQPCLIENT-2-CHUNKFAIL

Y

Y

Syslog

%CARDMGR-2-SYNC_CHECK_FAIL

N

N

Syslog

%PLATFORM_RPC-0-RESOURCE_CRASH

Y

Y

Syslog

%WCCP-1-CACHELOST

Y

N

Syslog

%ACLMGR-2-NOVLB

Y

N

Syslog

%SPANTREE-2-BLOCK_PVID_LOCAL

Y

N

Syslog

%SPANTREE-2-ROOTGUARD_BLOCK

Y

N

Syslog

%ENVIRONMENT-2-FAN_FAULT

Y

N

Syslog

%BSPATCH-1-RELOAD

Y

N

Syslog

%FRNTEND_CTRLR-1-MGR_TXQ_FULL

Y

Y

Syslog

%ACLMGR-2-NOMAP

Y

Y

Syslog

%FRNTEND_CTRLR-2-SUB_INACTIVE

Y

Y

Syslog

%SPANTREE-2-PVSTSIM_FAIL

Y

Y

Syslog

%SPANTREE-2-ROOTGUARD_UNBLOCK

N

N

Syslog

%PLATFORM-1-CRASHED

Y

Y

Syslog

%PM-2-LOW_SP_MEM

Y

N

Syslog

%PORT_SECURITY-2-PSECURE_VIOLATION

Y

N

Syslog

%SPANTREE-2-BLOCK_PVID_PEER

Y

N

Syslog

%SPANTREE-2-CHNL_MISCFG

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_CONFIG_CHANGE

Y

N

Syslog

%SPANTREE-2-UNBLOCK_CONSIST_PORT

N

N

Syslog

%RTD-1-ADDR_FLAP

Y

Y

Syslog

%CFGMGR-1-UNABLE_TO_SEND_STARTUP_CFG

Y

Y

Syslog

%ACLMGR-2-NOVLB

Y

N

Syslog

%PLATFORM_PBR-2-NO_RMAP

Y

N

Syslog

%SPANTREE-2-PVSTSIM_OK

N

N

Syslog

%SPANTREE-2-RECV_PVID_ERR

Y

Y

Syslog

%VQPCLIENT-2-DENY

N

N

Syslog

%BSPATCH-1-RELOAD

Y

N


Catalyst 4500 and 4900

Diagnostics

Environment

Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

Supervisor-bootup - Runs only on Supervisor modules as part of POST and performs CPU, traffic, system, system memory, and feature tests.

Y

Y

Diagnostics

Packet-memory-bootup - Boot time memory test performing diagnostics on SRAM and runs for all Supervisor modules to check if the packet-memory is initialized properly.

Y

Y

Diagnostics

Packet-memory-ongoing - This test performs diagnostics on SRAM and runs all the time on all Supervisor modules to ensure that packet-memory has valid data and that the data has not been corrupted.

Y

Y

Diagnostics

Linecard-online-diag - Verifies that all ports on a linecard are working correctly.

Y

Y

Diagnostics

Online-diag-tdr - Uses the Time Domain Reflectometer (TDR) feature to determine if the network cabling is at fault.

Y

N

Diagnostics

Stub-rx errors - Tests the data path from the supervisor to the line cards.

Y

Y

Diagnostics

Supervisor-rx-errors: Tests the data path from the supervisort to the line cards.

Y

Y


Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment
Redundancy Power Supply Failure - The second power supply installed on the switch, the backup, is detected and determined to be incompatible with the primary power supply.
Y
N
Environment

No Sufficient Power failure.

Y

N

Environment

Fan Assembly failure.

Y

N

Environment

System Alarms exceed critical or warning threshold.

Y

N

Environment

Bad Power Supply failure.

Y

N

Environment

Module major alarm on Module x All Module Temp Sensors failed.

Y

N

Environment

Module warning alarm on Module x Some Module Temp Sensors failed.

Y

N

Environment

Power warning alarm on Power Supply x Inline Power failed.

Y

N

Environment

Power warning alarm on Power Supply x Power Supply decreased.

Y

N

Environment

Power warning alarm on Power Supply x Power Supply Fan failed.

Y

N

Environment

System major alarm on Fan Tray bad.

Y

N

Environment

System warning alarm on Fan Tray Fan Assembly failure: partial.

Y

N

Environment

System warning alarm on Fan Tray Partial failure.

Y

N

Environment

Module major alarm on Module x All Module Temp Sensors failed.

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog
%SPANTREE-2-BLOCK_PVID_LOCAL
Y
N
Syslog

%C4K_IOSSYSMAN-0-FATALERRORCRASH

Y

Y

Syslog

%PM-2-LOW_SP_MEM

Y

Y

Syslog

%SPANTREE-2-LOOPGUARD_BLOCK

Y

N

Syslog

%SPANTREE-2-RECV_BAD_TLV

Y

N

Syslog

%C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD

Y

Y

Syslog

%SPANTREE-2-UNBLOCK_CONSIST_PORT

Y

N

Syslog

%C4K_CHASSIS-2-INSUFFICIENTPOWERDETECTED

Y

Y

Syslog

%C4K_CHASSIS-2-SUPERVISORINCOMPATIBLE

Y

Y

Syslog

%C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET

Y

N

Syslog

%PM-2-VLAN_ADD

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_CONFIG_CHANGE

Y

N

Syslog

%C4K_CHASSIS-2-ALLCHASSISSEEPROMSINVALID

Y

Y

Syslog

%C4K_SUPERVISOR-2-CHASSISSEEPROMINVALID

Y

Y

Syslog

%C4K_CHASSIS-2-INSUFFICIENTFANSSHUTDOWN

Y

Y

Syslog

%C4K_CHASSIS-2-INSUFFICIENTPOWERDETECTED

Y

Y

Syslog

%SPANTREE-2-PVSTSIM_FAIL

Y

N

Syslog

%SPANTREE-2-ROOTGUARD_BLOCK

Y

N

Syslog

%C4K_CHASSIS-2-INSUFFICIENTFANSSHUTDOWN

Y

Y

Syslog

%C4K_CHASSIS-3-ALLMODULETEMPERATURESENSORSFAILED

Y

Y

Syslog

%C4K_HWFLOWMAN-3-NFEINTERRUPTSTATUS

Y

N

Syslog

%C4K_IOSMODPORTMAN-2-MODULESHUTDOWNTEMP

Y

N

Syslog

%SPANTREE-2-RECV_PVID_ERR

Y

N

Syslog

%SPANTREE-2-ROOTGUARD_UNBLOCK

Y

N

Syslog

%C4K_SYSMAN-2-POWERONSELFTESTFAIL

Y

Y

Syslog

%C4K_CHASSIS-2-INSUFFICIENTPOWERSHUTDOWN

Y

Y

Syslog

%C4K_IOSIPROUTEMAN-3-ADJMANNOMOREADJS

Y

Y

Syslog

%SPANTREE-2-PVSTSIM_FAIL

Y

N

Syslog

%C4K_SUPERVISOR-2-FPGASOFTERROR:

Y

N

Syslog

%C4K_CHASSIS-2-INSUFFICIENTFANSDETECTED

N

N

Syslog

%SPANTREE-2-ROOTGUARD_CONFIG_CHANGE

Y

N

Syslog

%C4K_BUFFERMANAGER-2-OUTOFVBUFS

Y

N

Syslog

%SYS-3-P2_ERROR

Y

N

Syslog

%C4K_CHASSIS-2-INSUFFICIENTPOWERSHUTDOWN

Y

Y

Syslog

%C4K_CHASSIS-2-INSUFFICIENTFANSDETECTEDPOWERDOWN:

Y

Y

Syslog

%C4K_REDUNDANCY-2-IOS_VERSION_CHECK_FAIL

Y

N

Syslog

%SPANTREE-2-CHNL_MISCFG

Y

N

Syslog

%SPANTREE-2-RX_PORTFAST

Y

N

Syslog

%C4K_SUPERVISOR-2-MUXBUFFERNOTPRESENT

Y

Y

Syslog

%FIB-3-NOMEM

Y

Y

Syslog

%SPANTREE-2-BLOCK_PVID_PEER

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_UNBLOCK

Y

Y

Syslog

%SPANTREE-2-LOOPGUARD_BLOCK

Y

Y

Syslog

%SPANTREE-2-ROOTGUARD_BLOCK

Y

N

Syslog

%C4K_CHASSIS-2-INSUFFICIENTPOWERSHUTDOWN

Y

Y

Syslog

%C4K_CHASSIS-2-OVERHEATINGSHUTDOWN

Y

N

Syslog

%PM-2-NOMEM

Y

Y

Syslog

%C4K_REDUNDANCY-2-NON_SYMMETRICAL_REDUNDANT_SYSTEM

Y

N

Syslog

%SPANTREE_VLAN_SW-2-MAX_INSTANCE

Y

N

Syslog

%C4K_STORE-2-OUTOFCHUNKS

Y

Y

Syslog

%C4K_BUFFERMANAGER-2-OUTOFVBUFS

Y

N

Syslog

%C4K_CHASSIS-2-INLINEPOWEROFF

Y

Y

Syslog

%FIB-2-FIBDOWN

Y

Y

Syslog

%SPANTREE-2-LOOPGUARD_UNBLOCK

Y

N

Syslog

%C4K_REDUNDANCY-2-INCOMPATIBLE_SUPERVISORS

Y

N

Syslog

%C4K_IOSMODPORTMAN-2-MODULETEMPUNDERSHUTDOWN

Y

N

Syslog

%C4K_HWACLMAN-4-PARITYERROR:

Y

N

Syslog

%C4K_REDUNDANCY-3-PEER_RELOAD:

Y

Y

Syslog

%C4K_SWITCHINGENGINEMAN-4-VFERPINTERRUPT:

Y

Y


Catalyst 6500 and 7600

Diagnostics

Environment

Syslogs

Error Counters - Register Name

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

TestSPRPInbandPing - This test fails when the Switch Processor (SP) is not properly communicating with the Route Processor (RP) on the Supervisor module.

Y

Y

Diagnostics

TestScratchRegister - Monitors the health of the application-specific integrated circuits (ASICs) by writing values into registers then reading them back.

Y

Y

Diagnostics

TestMacNotification - Verifies the data and control path between the DFC modules.

Y

Y

Diagnostics

TestNonDisruptiveLoopback - Verifies the data path between the supervisor and the network ports of a line card.

Y

Y

Diagnostics

TestUnusedPortLoopback - A health monitoring test and runs every 60 seconds on admin-down ports.

Y

Y

Diagnostics

TestAsicSync - Periodically tests the status of bus and port synchronization ASICs.

Y

Y

Diagnostics

TestLoopback - Verifies the data path between the supervisor and the network ports of a line card.

Y

Y

Diagnostics

TestEarlMemOnBoot-up: An exhaustive test that tests all the bits and locations of EARL memories, supported by Generic Memory Testing Logic (GMTL); runs as a boot-up test.

Y

Y

Diagnostics

TestMgmtPortsLoopback: Tests layer 3 connectivity from the supervisor's in-band port to the Firewall/NAM service module to verify the health of the longest data path in the module.

Y

Y

Diagnostics

TestDataportLoopback: Tests layer 3 connectivity from the supervisor inbound port to one of the data ports on the service module.

Y

N

Diagnostics

TestDCPLoopback: Checks the data plane data path.

Y

N

Diagnostics

TestCCPLoopback: Checks the control plane data path.

Y

N

Diagnostics

TestNPLoopback: Verifies the data path between supervisor engine and four different NPs on ACE30.

Y

Y

Diagnostics

TestActiveToStandbyLoopback - Verifies the data path between the active supervisor and the network ports of the standby supervisor.

Y

N

Diagnostics

TestTransceiverIntegrity - Performed on the transceiver during transceiver Online Insertion and Removal (OIR) or card bootup to make sure the transceiver is supported.

Y

N

Diagnostics

TestNetflowInlineRewrite - Verifies netflow operation, ACL permit/deny, inline rewrite capabilities of the ASIC.

Y

Y

Diagnostics

TestNewIndexLearn - Makes sure that existing MAC address table entries can be updated.

N

N

Diagnostics

TestDontConditionalLearn - Verifies that the new source MAC addresses are not populated in the MAC address table when they should not be learned.

N

N

Diagnostics

TestBadBpdu - Verifies that the Trap feature of the Layer 2 forwarding engine is working properly.

N

N

Diagnostics

TestBadBpduTrap - Verifies the Trap feature of the Layer 2 forwarding engine.

N

N

Diagnostics

TestMatchCapture - Verifies the ability to match on specific Layer 2 protocols in the Layer 2 forwarding engine.

N

N

Diagnostics

TestStaticEntry - Verifies the ability to populate static entries in the Layer 2 MAC address table.

Y

Y

Diagnostics

TestDontLearn - Verifies the Don't Learn feature of the Layer 2 forwarding engine.

N

N

Diagnostics

TestNewLearn - Verifies the Layer 2 source MAC address learning functionality of the Layer 2 forwarding engine.

Y

Y

Diagnostics

TestIndexLearn - Verifies the Index Learn feature of the Layer 2 forwarding engine.

Y

Y

Diagnostics

TestConditionalLearn - Verifies the ability to learn a Layer 2 source MAC address under specific conditions.

N

N

Diagnostics

TestTrap - Verifies the Trap feature of the Layer 2 forwarding engine.

N

N

Diagnostics

TestBpduTrap - this test is a combination of TestBpdu and TestTrap. TestTrap verifies the ability to trap or redirect packets to the CPU. TestBpdu verifies the ability to redirect BPDU packets to the CPU.

Y

Y

Diagnostics

TestProtocolMatchChannel - Verifies the ability to match on specific Layer 2 protocols in the Layer 2 forwarding engine.

Y

Y

Diagnostics

TestCapture - Verifies the Capture (cap1) feature of the Layer 2 forwarding engine.

N

N

Diagnostics

TestFibDevices - Verifies whether the Forwarding Information Base (FIB) ternary content addressable memory (TCAM) and adjacency devices are functional.

Y

Y

Diagnostics

TestPortSecurity - Verifies the ability to redirect packets to the switch processor, if a secure MAC address is transmitting the packets from a different port.

Y

Y

Diagnostics

TestAclRedirect - Verifies the ACL redirect feature of the layer 3 forwarding engine (Supervisor Engine 2T).

   
Diagnostics

TestRBAcl - Verifies the role based ACL feature of the layer 3 forwarding engine (Supervisor Engine 2T).

Y

Y

Diagnostics

TestDQUP - Verifies the policer update packets can be generated when diagnostic packets hit QoS entry (Supervisor Engine 2T).

Y

Y

Diagnostics

TestInbandEdit - Verifies the inband edit packets of the layer 3 forwarding engine (Supervisor Engine 2T).

Y

Y

Diagnostics

TestIPv4FibShortcut - Verifies the IPV4 Forwarding Information Base (FIB) forwarding of the Layer 3 forwarding engine.

N

N

Diagnostics

TestNATFibShortcut - Verifies the ability to rewrite a packet based on network address translation (NAT) adjacency information (rewrite destination IP address).

N

N

Diagnostics

TestAclPermit - Verifies the access control list (ACL) permit functionality.

Y

Y

Diagnostics

TestNetflowShortcut - Verifies the Netflow forwarding of the Layer 3 forwarding engine.

N

N

Diagnostics

TestQos - Verifies whether the Quality of Service (QoS) input/output ternary content addressable memory (TCAM) is functional.

N

N

Diagnostics

TestIPv6FibShortcut - Verifies the IPV6 Forwarding Information Base (FIB) forwarding of the Layer 3 forwarding engine.

N

N

Diagnostics

TestMPLSFibShortcut - Verifies that the MPLS forwarding of the Layer 3 forwarding engine is working properly.

N

N

Diagnostics

TestL3Capture2 - Verifies the Layer 3 Capture (Capture 2) feature of the Layer 3 forwarding engine.

N

N

Diagnostics

TestL3TcamMonitoring - Enabled by default as a health monitoring test, verifies L3 packet switching (Supervisor Engine 2T).

Y

Y

Diagnostics

TestL2CTSLoopback - provides encapsulation for Layer 2 Ethernet packets sent from the supervisor engine inband port to each port inside the Ganita ASIC. The test sends back the Layer 2 Ethernet packet to the supervisor engine inband port after decapsulation with its original content.

Y

Y

Diagnostics

TestL3CTSLoopback - provides encapsulation for Layer 3 IPv4 packets sent from the supervisor engine inband port to each port inside the Ganita ASIC and sends back the Layer 3 IPv4 packet to the supervisor engine inband port after decapsulation with its original content.

Y

Y

Diagnostics

TestAclDeny - Verifies the access control list (ACL) deny feature of the Layer 2 and Layer 3 forwarding engine.

N

N

Diagnostics

TestL3VlanMet - Verifies the multicast functionality of the replication engine.

Y

Y

Diagnostics

TestIngressSpan - Ensures that the port application-specific integrated circuit (ASIC) is able to tag packets for ingress Switched Port Analyzer (SPAN).

N

N

Diagnostics

TestEgressSpan - Verifies the proper operation of the egress Switched Port Analyzer (SPAN) replication functionality of the rewrite engine for both SPAN queues.

N

N

Diagnostics

TestFabricVlanLoopback - a non-disruptive test supported for supervisors and line cards that have fabric switching ASIC. Tests the data path between the in-band port of the card under test and the local fabric port responsible for switching the traffic from and to the in-band port.

Y

Y

Diagnostics

TestFabricInternalSnake - Internal snake test.

Y

Y

Diagnostics

TestFabricSnakeBackward - External snake test.

Y

Y

Diagnostics

TestSynchedFabChaNel - Sends a Serial Control Protocol (SCP) control message to the line card and fabric to query the synch status.

Y

Y

Diagnostics

TestFabricCh0Health - Constantly monitors the health of the ingress and egress data paths for fabric channel #0 on 10G line cards.

Y

Y

Diagnostics

TestFabricCh1Health - Constantly monitors the health of the ingress and egress data paths for fabric channel #1 on 10G line cards.

Y

Y

Diagnostics

TestFibTcamSSRAM - Exhaustive memory test that checks the Forwarding Information Base (FIB) ternary content addressable memory (TCAM) and Layer 3 adjacency static random access memory (SSRAM).

Y

Y

Diagnostics

TestFibTcam - Exhaustive memory test that checks the Forwarding Information Base (FIB) ternary content addressable memory (TCAM) (Supervisor Engine 2T).

Y

Y

Diagnostics

TestAsicMemory - Exhaustive memory test that checks all memories on a module (supervisor or line card) using the MarchC test algorithm.

Y

Y

Diagnostics

TestAclQosTcam - Tests all the bits and locations of both access control lists (ACLs) and Quality of Service (QoS) Ternary Content Addressable Memory (TCAMs) on PFC3BXL, PFC3B, and Supervisor Engine 2T.

Y

Y

Diagnostics

TestNetflowTcam - Tests all the bits and locations of Netflow ternary content addressable memory (TCAM).

Y

Y

Diagnostics

TestQoSTcam - Exhaustive memory tests for Quality of Service (QoS) ternary content addressable memory (TCAM) devices.

Y

Y

Diagnostics

TestIPSecClearPkt - Verifies that encryption is not performed on sent packets.

N

N

Diagnostics

TestHapiEchoPkt - Sends a Hapi Echo packet to the crypto engine using the control path to get a packet echoed back from the crypto engine.

N

N

Diagnostics

TestIPSecEncryptDecryptPkt - Verifies that the encryption and decryption processes are working correctly.

Y

N

Diagnostics

TestTrafficStress - Stress test the system by using all the line cards on the chassis and ensuring that no packets get dropped.

N

N

Diagnostics

TestEobcStressPing - Stress-test a particular line card's Ethernet out-of-band chaNel (EOBC) link with the supervisor.

Y

Y

Diagnostics

ScheduleSwitchover - Allows the customer to trigger switch over at a desired date/time.

N

N

Diagnostics

TestFirmwareDiagStatus - Displays the result of power-on diag tests run by firmware during line card bring-up.

Y

Y

Diagnostics

TestOBFL - Verifies the on-board failure logging capabilities.

N

N

Diagnostics

TestCFRW - Performs a read write test on inserted compact flash (CF) card.

Y

N

Diagnostics

TestL3HealthMonitoring - Health monitoring test that runs periodically to check ASIC (Earl) error conditions.

Y

Y

Diagnostics

TestVslLocalLoopback - Verifies the hardware functionality of each port on a Vsl card before the Vsl link interface is up.

Y

Y

Diagnostics

TestVslStatus - Reports the status change detected by VSLP protocol.

Y

Y

Diagnostics

TestPortTxMonitoring - This test will error disable the failed port upon failure.

Y

N

Diagnostics

TestFabricFlowControlStatus - Detects chaNel rate reduction below the threshold, current fabric-chaNel utilization above the threshold, peak fabric-chaNel utilization and SP CPU utilization above the threshold.

Y

N

Diagnostics

TestSpuriousIsrDetection - Runs when an interrupt is detected on a fabric ASIC.

Y

N

Diagnostics

TestVDB - Check that ready bit is asserted and diag-fail bit is not.

Y

Y

Diagnostics

BusCoNectivityTest - A disruptive test and runs automatically during bootup and Health monitoring test.

Y

N

Diagnostics

TestIntPortLoopback - A nondisruptive health monitoring test.

Y

Y

Diagnostics

TestVslBridgeLink - Provides the diagnostic coverage not covered by the TestVslLocalLoopback test.

Y

Y

Diagnostics

TestVSActiveToStandbyLoopback - Only GOLD test which tests the full datapath across the virtual switch links.

Y

Y

Diagnostics

TestIPSecBaseComponents - covers as much component parts in IPSec base module (Cheronia) card as possible in run-time environment for hardware functionality and integrity check.

Y

Y

Diagnostics

TestIPSecSPAComponents - checks the components in the IPSec Shared Port Adapter (SPA) sub-module (Zamboni) in a run-time environment for hardware functionality and integrity check.

Y

Y

Diagnostics

TestL3Capture - erifies that the Layer 3 capture (capture 1) feature of the Layer 3 forwarding engine is working properly.

Y

N


Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment
System minor alarm on fan-tray x fan-fail
Y
Y
Environment

System major alarm on backplane clock count

Y

Y

Environment

System minor alarm on clock x OK

Y

Y

Environment

System major alarm on VTT x outlet temperature

Y

N

Environment

System minor alarm on VTT x outlet temperature

Y

N

Environment

System minor alarm on VTT x OK

Y

Y

Environment

Module major alarm on module x fan-upgrade required

Y

N

Environment

System minor alarm on power-supply x fan-fail

Y

N

Environment

System minor alarm on power-supply x power-output-fail

Y

N

Environment

Module major alarm on module x inlet temperature

Y

N

Environment

Module major alarm on module x outlet temperature

Y

N

Environment

Module major alarm on RP x inlet temperature

Y

N

Environment

Module major alarm on RP x outlet temperature

Y

N

Environment

Module major alarm on EARL x inlet temperature

Y

N

Environment

Module major alarm on EARL x outlet temperature

Y

N

Environment

Module major alarm on module x device-1 temperature

Y

N

Environment

Module major alarm on module x device-2 temperature

Y

N

Environment

System minor alarm on power-supply x incompatible with fan

Y

N

Environment

Module major alarm on module x insufficient cooling

Y

N

Environment

System minor alarm on backplane clock count

Y

Y

Environment

System minor alarm on backplane VTT count

Y

Y

Environment

System major alarm on backplane VTT count

Y

N

Environment

System minor alarm on backplane Fantray count

Y

N

Environment

Module minor alarm on module x inlet temperature

Y

N

Environment

Module minor alarm on module x outlet temperature

Y

N

Environment

Module minor alarm on module x device-1 temperature

Y

N

Environment

Module minor alarm on module x device-2 temperature

Y

N

Environment

Module minor alarm on RP x inlet temperature

Y

N

Environment

Module minor alarm on RP x outlet temperature

Y

N

Environment

Module minor alarm on EARL x inlet temperature

Y

N

Environment

Module minor alarm on EARL x outlet temperature

Y

N

Environment

Module minor alarm on module x asic-1 temperature

Y

N

Environment

Module minor alarm on module x asic-2 temperature

Y

N

Environment

Module minor alarm on module x asic-3 temperature

Y

N

Environment

Module minor alarm on module x asic-4 temperature

Y

N

Environment

Module minor alarm on module x asic-5 temperature

Y

N

Environment

Module minor alarm on module x asic-6 temperature

Y

N

Environment

Module minor alarm on module x aux-1 temperature

Y

N

Environment

Module major alarm on module x asic-1 temperature

Y

N

Environment

Module major alarm on module x asic-2 temperature

Y

N

Environment

Module major alarm on module x asic-3 temperature

Y

N

Environment

Module major alarm on module x asic-4 temperature

Y

N

Environment

Module major alarm on module x asic-5 temperature

Y

N

Environment

Module major alarm on module x asic-6 temperature

Y

N

Environment

Module major alarm on module x aux-1 temperature

Y

N

Environment

System minor alarm on power-supply x power-output-mode

Y

N

Environment

Power minor alarm on module x power-output-fail

Y

N


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslog

%BGP_SESSION-5-ADJCHANGE

Y

N

Syslog

%OIR-3-PWRCYCLE

Y

Y

Syslog

%AAL5-1-NOBUFFER

Y

N

Syslog
%AAL5-1-NOMEMORY

Y

N

Syslog

%PM_SCP-2-LCP_FW_ERR_INFORM

Y

Y

Syslog

%ALARM-1-CRITICAL_ALARM

Y

N

Syslog

%ALIGN-1-FATAL

Y

Y

Syslog

%AMDP2_FE-1-DISCOVER

Y

N

Syslog

%AMDP2_FE-1-INITFAIL

Y

Y

Syslog

%AMDP2_FE-1-MEMERR

Y

Y

Syslog

%AMDP2_FE-1-NOMII

Y

N

Syslog

%AP-1-AUTH_PROXY_DDOS_ATTACK

Y

N

Syslog

%AP-1-AUTH_PROXY_DOS_ATTACK

Y

N

Syslog

%AP-1-AUTH_PROXY_RETRIES_EXCEEDED

Y

N

Syslog

%AP-1-POSTURE_POLICY_ERROR

Y

N

Syslog

%AP-1-POSTURE_POLICY_ERROR_HOST_ACL

Y

N

Syslog

%ARAP-0-WAITBADMSG

Y

N

Syslog

%AT-1-NOMEM

Y

N

Syslog

%ATMCES-1-BAD1575

Y

Y

Syslog

%ATMCES-1-BADSLAVE

Y

Y

Syslog

%ATMCES-1-ERRCREATEVC

Y

N

Syslog

%ATMCES-1-ERRRMVC

Y

N

Syslog

%ATMLC-1-INITFAIL

Y

N

Syslog

%ATMOC3-1-DISCOVER

Y

Y

Syslog

%ATMOC3-1-INITFAIL

Y

N

Syslog

%ATMOC3-1-INVALID_PCI_ID

Y

Y

Syslog

%ATMOC3-1-INVALIDPAK

Y

N

Syslog

%ATMOC3-1-PCMCIA

Y

Y

Syslog

%ATMOC3-1-PVP

Y

N

Syslog

%ATMOC3-1-TOOBIG

Y

N

Syslog

%ATMPA-1-CTRLMEMFAIL

Y

Y

Syslog

%ATMPA-1-INVALIDCONFIG

Y

N

Syslog

%ATMPA-1-REGFAIL

Y

N

Syslog

%ATMSPA-2-INITFAIL

Y

Y

Syslog

%AUDIT-1-FILE_ROLLOVER

Y

N

Syslog

%AUDIT-1-FILESYSTEM:

Y

N

Syslog

%BCM3220-1-INITFAIL

Y

Y

Syslog

%BRI-1-NOMEMORY

Y

N

Syslog

%C4K_REDUNDANCY-2-POSTFAIL

Y

Y

Syslog

%C6K_PLATFORM-0-UNKNOWN_CHASSIS

Y

Y

Syslog

%C6K_POWER-1-PD_HW_FAULTY

Y

Y

Syslog

%C6KENV-1-SHUTDOWN_DISABLED

Y

N

Syslog

%C6KENV-2-BADFLOWCTRL

Y

Y

Syslog

%C6KENV-2-BADFLOWCTRL_WARN

Y

Y

Syslog

%C6KENV-2-BADTRANSCEIVER

Y

Y

Syslog

%C6KENV-2-DFCMISMATCH:

Y

Y

Syslog

%C6KENV-2-DFCMISMATCHMINOR

Y

N

Syslog

%C6KENV-2-FANUPGREQ

Y

Y

Syslog

%C6KENV-2-MAJORTEMPALARM

Y

N

Syslog

%C6KENV-2-SHUTDOWN

Y

N

Syslog

%C6KENV-2-SHUTDOWN_SCHEDULED

Y

N

Syslog

%C6KENV-2-SHUTDOWN-CANCELLED

Y

Y

Syslog

%C6KENV-SP-0-CLOCKMAJFAILED

Y

Y

Syslog

%C6KENV-SP-0-VTTMAJFAILED

Y

Y

Syslog

%C6KERRDETECT-2-FIFOCRITLEVEL:

Y

N

Syslog

%C6KERRDETECT-2-SWBUSSTALL

Y

N

Syslog

%C6KERRDETECT-2-SWBUSSTALL_RECOVERED

Y

N

Syslog

%C6KPWR-2-PSFAIL

Y

N

Syslog

%C6KPWR2-PSOCPSHUTDOWN

Y

Y

Syslog

%C7600_ERRDETECT-2-SWBUSSTALL

Y

Y

Syslog

%C7600_PWR-2-PSFAIL

Y

Y

Syslog

%CALL_MGMT-1-CALL_LIST

Y

N

Syslog

%CALL_MGMT-1-CPM_Q_POOL

Y

N

Syslog

%CARDMGR-2-ESF_DEV_ERROR

Y

N

Syslog

%CARDMGR-2-ESF_LOAD_FAIL

Y

N

Syslog

%CARDMGR-2-SPABUS_ERROR

Y

N

Syslog

%CE3-1-CONFIGURE

Y

Y

Syslog

%CE3-1-INITFAIL

Y

N

Syslog

%CFGMGR-1-UNABLE_TO_SEND_RUN_CFG

Y

N

Syslog

%CFGMGR-1-UNABLE_TO_SEND_STARTUP_CFG

Y

N

Syslog

%CHOPIN-1-OVERTEMP

Y

N

Syslog

%CI-0-SHUTFANGONE

Y

Y

Syslog

%CI-1-NOFAN

Y

N

Syslog

%CI-1-TOTALFANFAIL

Y

N

Syslog

%CLNS-1-BKUPERR

Y

N

Syslog

%CONST_DIAG-2-HM_FAB_SWOVER

Y

N

Syslog

%CONST_DIAG-2-HM_LC_CRSH

Y

N

Syslog

%CONST_DIAG-2-HM_MOD_RESET

Y

N

Syslog

%CONST_DIAG-2-HM_SUP_CRSH

Y

N

Syslog

%CONST_DIAG-2-HM_SUP_SWOVER

Y

N

Syslog

%CONST_DIAG-2-HM_TEST_FAIL

Y

N

Syslog

%CONST_DIAG-2-HM_TEST_WARNING

Y

N

Syslog

%CONST_DIAG-2-MOD_RESET_AFTER_DISRUPTIVE_DIAG:

Y

N

Syslog

%CPU_MONITOR-2-NOT_RUNNING

Y

N

Syslog

%CPU_MONITOR-2-NOT_RUNNING_TB

Y

N

Syslog

%CPU_NET-0-QUEUE_STUCK

Y

N

Syslog

%CRYPTO-0-AUDITFAIL

Y

N

Syslog

%CRYPTO-0-SELF_TEST_FAILURE

Y

N

Syslog

%CSM-1-CAS_MSG_DEPLETED

Y

N

Syslog

%CSM-1-CSM_MODEM_BAD

Y

N

Syslog

%CSM-1-HWIDB

Y

N

Syslog

%CSM-1-HWIDB_SUBBLOCK

Y

N

Syslog

%CSM-1-HWREV

Y

N

Syslog

%CSM-1-INITPORT

Y

N

Syslog

%CSM-1-MODEM_INFO

Y

N

Syslog

%CT3-1-CONFIGURE

N

N

Syslog

%CT3-1-DWNLDFAIL

Y

N

Syslog

%CT31-INITFAIL

Y

N

Syslog

%CT3-1-UNSUPPORTED

Y

N

Syslog

%CWAN_HA-2-CCB_PLAYBACK_ERROR

Y

N

Syslog

%CWAN_HA-2-CCB_RECORD_ERROR

Y

N

Syslog

%CWAN_HA-2-IFCFG_PLAYBACK_ERROR

Y

N

Syslog

%CWAN_RP-0-LCLOG_MSG

Y

N

Syslog

%CWAN_RP-2-LCLOG_MSG

Y

N

Syslog

%CWPA-2-BAD_HWVERS

Y

N

Syslog

%CWPA-2-PA_VOLFAIL

Y

N

Syslog

%CWPA-2-PAOIR

Y

N

Syslog

%CWTLC-0-FATAL_EXCEPTION

Y

Y

Syslog

%CWTLC-2-FATAL_ATM

Y

N

Syslog

%DCU-1-NODCUPORTS

Y

N

Syslog

%DCU-1-NOMEMORY

Y

N

Syslog

%DEC21140-1-DISCOVER

Y

N

Syslog

%DEC21140-1-INITFAIL

Y

N

Syslog

%DEMO-C6KPWR-4-DISABLED

Y

N

Syslog

%DIAG-3-MAJOR:

Y

Y

Syslog

%DSX1-1-FIRMWARE_RUNNING

Y

N

Syslog

%DSX1-1-FIRMWARE_STOPPED

Y

N

Syslog

%DSX1-1-M32_INPUT_CONGEST

Y

N

Syslog

%EARL_L2_ASIC-0-EXCESSIVE_FT_TBL_ECC_ERR

Y

N

Syslog

%EARL_L2_ASIC-0-FATAL_INTR

Y

N

Syslog

%EARL_L2_ASIC-2-PARITY_ERR

Y

N

Syslog

%EARL_NETFLOW-0-NF_ECC_MAX

Y

Y

Syslog

%EARL-0-TASK_SPAWN_FAIL

Y

Y

Syslog

%EARL-2-EARL4LOOKUPRAMERROR

Y

Y

Syslog

%ENSP-1-NOMEMORY

Y

N

Syslog

%ENVM-0-SHUT

Y

N

Syslog

%EOBC-2-EOBC_JAM

Y

N

Syslog

%EOBC-SP-0-EOBC_JAM_FATAL

Y

Y

Syslog

%ESF_EVENTINFO-2-WRITING_EVENTINFO

Y

N

Syslog

%ESF_EVENTINFO-2-WRITING_EVENTINFO

Y

Y

Syslog

%ESWITCH-1-NOTPLX

Y

N

Syslog

%ESWITCH-1-PCIINIT

Y

N

Syslog

%ESWITCH-1-TSWITCH

Y

Y

Syslog

%ESWITCH-1-TSWITCHEALE

Y

N

Syslog

%FABRIC-5-CLEAR_BLOCK

Y

N

Syslog

%FABRIC-5-FABRIC_MODULE_ACTIVE

Y

N

Syslog

%FDDI-1-NOMEMORY

Y

N

Syslog

%FECPM-1-DISCOVER

Y

Y

Syslog

%FECPM-1-INITFAIL

Y

Y

Syslog

%FECPM-1-UNKNOWN_WIC

Y

N

Syslog

%FM-1-INIT

Y

N

Syslog

%FTSP-1-NOMEMORY

Y

N

Syslog

%FWSM-1-103001

Y

N

Syslog

%FWSM-1-103003

Y

N

Syslog

%FWSM-1-103003

Y

Y

Syslog

%FWSM-1-103003

N

N

Syslog

%FWSM-1-103004

Y

N

Syslog

%FWSM-1-103005

Y

N

Syslog

%FWSM-1-104001

Y

N

Syslog

%FWSM-1-104003

Y

N

Syslog

%FWSM-1-105001

Y

N

Syslog

%FWSM-1-105002

Y

N

Syslog

%FWSM-1-105005

Y

N

Syslog

%FWSM-1-105008

Y

N

Syslog

%FWSM-1-105011

Y

N

Syslog

%FWSM-1-105038

Y

N

Syslog

%FWSM-1-105040

Y

N

Syslog

%FWSM-1-105044

Y

N

Syslog

%FWSM-1-105045

Y

N

Syslog

%FWSM-1-106021

Y

N

Syslog

%FWSM-1-106022

Y

N

Syslog

%FWSM-1-106101

Y

N

Syslog

%FWSM-1-107001

Y

N

Syslog

%FWSM-1-107002

Y

N

Syslog

%FX1000-1-DISCOVER

Y

N

Syslog

%FX1000-1-INITFAIL_NOMEM

Y

N

Syslog

%GIGASTACK-1-NO_LOOP_DETECT

Y

N

Syslog

%GPRSFLTMG-0-GPRS_DHCP

Y

N

Syslog

%GPRSFLTMG-0-GPRS_SERVICE

Y

N

Syslog

%GPRSFLTMG-0-GTPv1NORESOURCE

Y

N

Syslog

%GPRSFLTMG-0-PACKETPARSINGERROR

Y

N

Syslog

%GPRSFLTMG-0-RESOURCE

Y

N

Syslog

%GTP-0-NORESOURCE

Y

N

Syslog

%GTP-0-PACKETPARSINGERROR

Y

N

Syslog

%HAL-1-CONFIGURE

Y

N

Syslog

%HAL-1-DISCOVER

Y

N

Syslog

%HAL-1-INITFAIL

Y

N

Syslog

%HAL-1-STOPFAIL

Y

N

Syslog

%HAL-1-UNSUPPORTED

Y

N

Syslog

%HD-1-BADLOOPCABLE

Y

N

Syslog

%HD-1-BADPORTADAPTER

Y

N

Syslog

%HW_VPN-1-BADMEMSIZE

Y

N

Syslog

%HW_VPN-1-BADTYPE

Y

N

Syslog

%HW_VPN-1-DEVID

Y

N

Syslog

%HW_VPN-1-DEVINIT

Y

Y

Syslog

%HW_VPN-1-ELMERREV

Y

N

Syslog

%HW_VPN-1-HELLOERR

Y

Y

Syslog

%HW_VPN-1-HPRXERR

Y

N

Syslog

%HW_VPN-1-INITFAIL

Y

Y

Syslog

%HW_VPN-1-LPRXERR

Y

N

Syslog

%HW_VPN-1-NOHW

Y

N

Syslog

%HW_VPN-1-POSTFAIL

Y

Y

Syslog

%I82543-1-BAD_POOL

Y

N

Syslog

%I82543-1-BAD_SB_NOMEM

Y

N

Syslog

%I82543-1-DISCOVER

Y

N

Syslog

%I82543-1-IDBTYPE_UNK

Y

Y

Syslog

%I82543-1-INITFAIL_NOMEM

Y

N

Syslog

%IBM2692-1-DISCOVER

Y

N

Syslog

%IBM2692-1-LL_QUEUE_OVERFLOW

Y

N

Syslog

%IBM2692-1-OLDREV

Y

N

Syslog

%IBM2692-1-SRBQ_OVERFLOW

N

N

Syslog

%IDTATM25-1-DISCOVER

Y

N

Syslog

%ILACC-1-INITFAIL

Y

N

Syslog

%ILACC-1-MEMERR

Y

N

Syslog

%IMA-1-BAD_CMD

Y

N

Syslog

%IMA-1-DISCOVER

Y

N

Syslog

%IMA-1-DOWNLOAD_FAILED

Y

N

Syslog

%IMA-1-FPGA_DOWNLOAD_FAIL

Y

N

Syslog

%IMA-1-INVALID_PCI_ID

Y

N

Syslog

%IMA-1-MAILBOX_FULL

Y

N

Syslog

%IMA-1-NETWORK_PROCESSOR_NOT_READY

Y

N

Syslog

%IMA-1-NO_ATM_CHANNEL_AVAILABLE

Y

N

Syslog

%IMA-1-NO_MAIL_REPLY

Y

N

Syslog

%IMA-1-PCMCIA

Y

N

Syslog

%IMA-1-PROCESS_NEVER_RECEIVED_MAIL_REPLY

Y

N

Syslog

%IMA-1-SHARED_MEMORY_ERROR

Y

N

Syslog

%INTERFACE_API-1-NOMORESWIDB

Y

N

Syslog

%IPM_C54X-1-NO_RING_DESCRIPTORS

Y

N

Syslog

%IPM_C54X-1-TOOBIG

Y

N

Syslog

%ISA-1-ERROR

Y

N

Syslog

%ISA-1-INITFAIL

Y

N

Syslog

%ISA-1-NOMEMORY

Y

N

Syslog

%ISA-1-OWNER

Y

N

Syslog

%ISSU-3-FSM_MISMATCH_MTU

Y

N

Syslog

%L2_AGING-2-DEC_EN_FAIL

Y

N

Syslog

%LANCE-1-INITFAIL

Y

N

Syslog

%LANCE-1-MEMERR

Y

N

Syslog

%LC-1-TESTALERT

Y

N

Syslog

%LCGE-1-INITFAIL

Y

N

Syslog

%LINK-0-REENTER

Y

Y

Syslog

%LTL-2-LTL_PARITY_CHECK

Y

N

Syslog

%M32X-1-AR_TIMEOUT

Y

N

Syslog

%MCAST-2-IGMP_SNOOP_DISABLE

Y

N

Syslog

%MCX-1-STARTFAIL

Y

N

Syslog

%MLSCEF-2-FIB_SSRAM_WRITE_INCONSISTENCY

Y

N

Syslog

%MLSCEF-2-FIB_TCAM_WRITE_INCONSISTENCY

Y

N

Syslog

%MRIB_PROXY-2-MRIB_LC_CREPRC_FAILED

Y

N

Syslog

%MRIB_PROXY-2-MRIB_LC_FAILED_IPC_OPEN

Y

N

Syslog

%MRIB_PROXY-2-MRIB_LC_FETCH_FAIL

Y

N

Syslog

%MUESLIX-1-CLOCKRATE

Y

N

Syslog

%MUESLIX-1-DWNLDFL

Y

N

Syslog

%MUESLIX-1-FAILURE_CAUSE

Y

N

Syslog

%MUESLIX-1-STARTFAIL

Y

N

Syslog

%MUESLIX-1-STOPFAIL

Y

N

Syslog

%NBAR-1-LINKNEXTCORRUPTED

Y

N

Syslog

%NBAR-1-LINKPREVCORRUPTED

Y

N

Syslog

%NBAR-1-NODESIZEMISMATCH

Y

N

Syslog

%OIR-3-LC_FAILURE

Y

Y

Syslog

%PFINIT-1-CONFIG_SYNC_FAIL

Y

N

Syslog

%PFINIT-1-CONFIG_SYNC_FAIL_RETRY

Y

N

Syslog

%PFINIT-5-CONFIG_SYNC

N

N

Syslog

%PFREDUN-4-BOOTSTRING_INVALID

Y

Y

Syslog

%PIM-1-INVALID_RP_REG

Y

N

Syslog

%PIM-1-INVALID_SRC_REG

Y

N

Syslog

%PIM-1-SR_INTERVAL_SETTING_ERR

Y

N

Syslog

%PISAL2M-2-ERROR

Y

N

Syslog

%PLATFORM_RPC-0-RESOURCE_CRASH

Y

Y

Syslog

%PLATFORM-1-CRASHED

Y

N

Syslog

%PM_SCP-1-LCP_FW_ERR

Y

Y

Syslog

%PM_SCP-1-LCP_FW_ERR:

Y

Y

Syslog

%PM_SCP-2-LCP_FW_ERR_INFORM:Bus Asic

Y

N

Syslog

%PM_SCP-2-LCP_FW_ERR_INFORM:Inline Power Module

Y

N

Syslog

%PM_SCP-2-TRANSCEIVER_INCOMPATIBLE

Y

N

Syslog

%PM-1-INCONSISTENT_PORT_STATE

Y

N

Syslog

%PM-SCP-2-LCP_FW_ERR_INFORM_Port

Y

N

Syslog

%PORT_SECURITY-2-PSECURE_VIOLATION

Y

N

Syslog

%PQUICC_FE-1-INITFAILP

Y

N

Syslog

%PQUICC_FE-1-SHOWFAIL

Y

N

Syslog

%PS-1-INITSYS

Y

N

Syslog

%PWR-4-PSREDUNDANTBOTHSUPPLY

Y

N

Syslog

%QM-2-PLC_ATTACH_REJECT_2_PLCRS

Y

N

Syslog

%QM-2-PLC_ATTACH_REJECT_SET

Y

N

Syslog

%QUICC_ETHER-1-LOSTCARR

Y

N

Syslog

%QUICC_SERIAL-1-INITFAIL

Y

N

Syslog

%QUICC-1-BADHDXFSM

Y

N

Syslog

%QUICC-1-INITFAIL

Y

N

Syslog

%QUICC-1-LINEFLAP

Y

N

Syslog

%QUICC-1-NOMEMORY

Y

N

Syslog

%QUICC-1-TOOBIG

N

N

Syslog

%QUICC-1-TOOSMALL

N

N

Syslog

%QUICC-1-UNDERFLO

N

N

Syslog

%QUICC-1-UNEXPECTED_INTERRUPT

Y

N

Syslog

%QUICC-1-UNKNOWN_WIC

Y

N

Syslog

%QUICC-1-UNSUPPORTED_CONFIG

Y

N

Syslog

%QUICC-1-WRONG_SLOT

Y

N

Syslog

%REGISTRY-2-REG_FLAG_DEADLOCK

Y

N

Syslog

%REGISTRY-2-REG_PARSE_ERROR

Y

N

Syslog

%RESOURCE_MON-1-RSCMON_CLIENT_Q

Y

N

Syslog

%RPC-2-FAILED

Y

Y

Syslog

%RPC-2-FAILED_USERHANDLE

Y

Y

Syslog

%RPC-2-FAILED_USERHANDLE:

Y

Y

Syslog

%S4T68360-1-DWNLDFAIL

Y

N

Syslog

%S4T68360-1-INITFAIL

Y

N

Syslog

%S4T68360-1-STARTFAIL

Y

N

Syslog

%S4T68360-1-STOPFAIL

Y

Y

Syslog

%SBETH-1-BAD_IDB

Y

N

Syslog

%SBETH-1-BAD_SB_NOMEM

Y

N

Syslog

%SBETH-1-INITFAIL_NOMEM

Y

N

Syslog

%SBFIFO-1-BAD_IDB

Y

N

Syslog

%SBFIFO-1-BAD_SB_NOMEM

Y

N

Syslog

%SBFIFO-1-INITFAIL_NOMEM

Y

N

Syslog

%SCHED-0-WATCHDOG

Y

Y

Syslog

%SEC_LOGIN-1-QUIET_MODE_ON

Y

N

Syslog

%SERVICE_MODULE-0-INITWICFAILURE

Y

N

Syslog

%SFF8472-2-NOMEM

Y

N

Syslog

%SGBP-1-AUTHFAILED

Y

N

Syslog

%SGBP-1-DIFFERENT

Y

N

Syslog

%SGBP-1-MISSCONF

Y

N

Syslog

%SGBP-1-UNKNOWNHELLO

Y

N

Syslog

%SIGSM-1-NO_TEMPLATE_ERR

Y

N

Syslog

%SIP400-2-IOBUS_ERROR

Y

N

Syslog

%SIP400-2-PCI_BUS_ERROR

Y

N

Syslog

%SIP400-2-PCI_ERROR_INT

Y

N

Syslog

%SIP600_QOS-2-INITFAIL

Y

N

Syslog

%SIP600_QOS-2-NOMEM

Y

N

Syslog

%SIP600-2-DEVMGR_ASIC_INIT_FAILED

Y

N

Syslog

%SIP600-2-DEVMGR_PROC_CREATE_FAILED

Y

N

Syslog

%SMC-2-BAD_ID_HW

Y

Y

Syslog

%SONETMIB-1-MALLOCNEW

Y

N

Syslog

%SONICT-1-INITFAIL

Y

N

Syslog

%SPA_ETHER-1-ALLOCFAIL

Y

N

Syslog

%SPANTREE-2-BLOCK_PVID_LOCAL

Y

N

Syslog

%SPANTREE-2-BLOCK_PVID_PEER

Y

N

Syslog

%SPANTREE-2-LOOPGUARD_BLOCK

Y

N

Syslog

%SPANTREE-2-RECV_BAD_TLV

Y

N

Syslog

%SPANTREE-2-RECV_PVID_ERR

Y

N

Syslog

%SPANTREE-2-RECV_PVID_ERR

N

N

Syslog

%SPANTREE-2-ROOTGUARD_BLOCK

Y

N

Syslog

%SPANTREE-2-UNBLOCK_CONSIST_PORT

Y

N

Syslog

%STANDBY-3-DIFFVIP1:

Y

N

Syslog

%SVCLC-2-MAJORTEMP

Y

N

Syslog

%SWITCH-1-NOMEMORY

Y

N

Syslog

%SYS-*.2-LINEPROCDEAD:

Y

N

Syslog

%SYS-1-CPU(FALLING|RISING)THRESHOLD:

Y

N

Syslog

%SYS-1-OVERTEMP

Y

N

Syslog

%SYS-2-MOD_TEMPSENSORFAIL:

Y

N

Syslog

%TDM-1-TDM_INITFAIL

Y

N

Syslog

%TDM-1-TDM_MB_INITFAIL

Y

N

Syslog

%THERMO-1-INCORRECT_MAJOR_THRESH

Y

N

Syslog

%THERMO-1-INCORRECT_MINOR_THRESH

Y

N

Syslog

%THERMO-1-READ_TEMP_FAILED

Y

N

Syslog

%THERMO-1-TEMP_MAJOR_ALARM

Y

N

Syslog

%THERMO-1-TEMP_MINOR_ALARM :

Y

N

Syslog

%THERMO-1-TOO_COLD

Y

N

Syslog

%TI1570-1-DEVICEINITFAIL

Y

N

Syslog

%TI1570-1-IDBINITFAIL

Y

N

Syslog

%TI1570-1-INITFAIL

Y

N

Syslog

%TI1570-1-INVALIDCONFIG

Y

N

Syslog

%TRANGE-2-NOMEMORY

Y

N

Syslog

%TRANGE-2-WRONGREQUEST

Y

N

Syslog

%TRANGE-2-WRONGSIZE

Y

N

Syslog

%VFC-1-INVALID-CONFIGURATION

Y

N

Syslog

%VFC-1-NO_DSPM

Y

N

Syslog

%VFC-1-NO_RING_DESCRIPTORS

Y

N

Syslog

%VPA-1-RPTFAIL

Y

N

Syslog

%VPD-1-UNKNOWN_VIC

Y

N

Syslog

%VPD-1-UNSUPPORTED_VIC

Y

N

Syslog

%VPN_HW-1-ERROR

Y

N

Syslog

%VPN_HW-1-HEARTBEAT

Y

N

Syslog

%VPN_HW-1-INITFAIL

Y

N

Syslog

%VPN_HW-1-NOMEMORY

Y

N

Syslog

%VPN_HW-1-OWNER

Y

N

Syslog

%VPN_HW-1-PACKET_ERROR

Y

Y

Syslog

%VPN_HW-1-UNSUPP

Y

N

Syslog

%VSLP2-VSL_DOWN

Y

Y

Syslog

%WSHTF-1-INITFAIL_NOBUF

Y

N

Syslog

%FWSM-1-105039

Y

N

Syslog

%FWSMSSSSSS-1-100000

Y

N

Syslog

%LTL-2-LTL_PARITY_CHECK

Y

N

Syslog

%PIM-1-INVALID_RP_REG

Y

N

Syslog

RPC-2-CORE_SAT_RPC_FAIL

Y

N

Syslog
%FABRIC-5-CLEAR_BLOCK:

Y

N

Syslog
%FABRIC-5-FABRIC_MODULE_ACTIVE:

Y

N

Syslog
LTL-2-LTL_PARITY_CHECK:

Y

N

Syslog
%OIR-3-LC_FAILURE:

Y

Y

Syslog
%PFINIT-5-CONFIG_SYNC:

N

N

Syslog
PKI-4-NOAUTOSAVE:

Y

N

Syslog
SNMP-5-COLDSTART:

Y

N

Syslog
%AAA-3-ACCT_LOW_MEM_UID_FAIL:

Y

N

Syslog
%AAA-3-DROPACCTFAIL:

Y

N

Syslog
%BGP_SESSION-5-ADJCHANGE:

Y

N

Syslog
%BGP-3-NOTIFICATION:

Y

N

Syslog
%BGP-5-ADJCHANGE:

Y

N

Syslog
%C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET:

Y

N

Syslog
%SYS-4-SNMP_WRITENET:

Y

N

Syslog
%C4K_REDUNDANCY-5-CONFIGSYNC:

Y

N

Syslog
%C6KPWR-4-PSOK:

Y

N

Syslog
%C7600_PWR-4-PSOK:

Y

N

Syslog
%PWR-4-PSREDUNDANTBOTHSUPPLY:

Y

N

Syslog
%C7600_PWR-4-PSREDUNDANTONESUPPLY:

Y

N

Syslog
%CLNS-3-BADPACKET:

Y

N

Syslog
%CRYPTO-4-IKMP_NO_SA:

Y

N

Syslog
%CRYPTO-4-PKT_REPLAY_ERR:

Y

N

Syslog
%DIALPEER_DB-3-ADDPEER_MEM_THRESHOLD:

Y

N

Syslog
%DIALPEER_DB-3-DIALPEER_ACCOUNTING:

Y

N

Syslog
%DIRECTOR-3-DRPDOWN:

Y

N

Syslog
%DIRECTOR-3-NOTCONF:

Y

N

Syslog
%DISKMIRROR-3-DST:

Y

N

Syslog
%DISKMIRROR-3-SRC:

Y

N

Syslog
%DLSWC-3-BADSSPHDR:

Y

N

Syslog
%DLSWC-3-IDMGR:

Y

N

Syslog
%DLSWMasterSlave-3-DLSWMS:

Y

N

Syslog
%ESWMOD-3-INITFAILURE:

Y

N

Syslog
%ESWMOD-3-NOT_RESPONDING:

Y

N

Syslog
%ET2_MODULE-3-INITFAILURE:

Y

N

Syslog
%ETHCNTR-3-FLOWCONTROL_DUPLEX_ERROR:

Y

N

Syslog
%ETHCNTR-3-FLOWCONTROL_DUPLEX_ERROR:

Y

N

Syslog
%ETHCNTR-3-HALF_DUX_COLLISION_EXCEED_THRESHOLD:

Y

N

Syslog
%ETHCNTR-3-INTERNAL_ERROR:

Y

N

Syslog
%ETHCNTR-3-RA_ALLOC_ERROR:

Y

N

Syslog
%ETHCNTR-3-RA_REPLY_ERROR:

Y

N

Syslog
%ETH_SPA_MAC-3-INTR_BURST:

Y

N

Syslog
%ETH_SPA_MAC-3-SPI4_ERROR:

Y

N

Syslog
%ETH_SPA_MAC-3-SPI4_SINK_INIT_ERR:

Y

N

Syslog
%ETH_SPA_MAC-3-UNREC_ECC_ERR:

Y

N

Syslog
%ETSEC-3-RESTART:

Y

N

Syslog
%EVENT_TRACE-3-NO_FILENAME:

Y

N

Syslog
%EXPRESS_SETUP-3-UNABLE_TO_RESET_CONFIG:

Y

N

Syslog
%FALLBACK-3-RTR_CREATE_FAIL:

Y

N

Syslog
%FBINFO-3-CRASH:

Y

N

Syslog
%FDM-3-TCAM_ENTRY_MISSING:

Y

N

Syslog
%FDM-3-TCAM_ENTRY_CORRUPTED:

Y

N

Syslog
%FDM-3-BLOCK_INIT_FAILURE:

Y

N

Syslog
%FECPM-3-SCCRESET:

Y

N

Syslog
%FIB-3-NOMEM:

Y

N

Syslog
%FIB-3-FIBDISABLE:

Y

N

Syslog
%FILESYS-3-IPC:

Y

N

Syslog
%FILESYS-3-FLASH:

Y

N

Syslog
%FLEXDSPRM-3-TDM_CONNECT:

Y

N

Syslog
%FLEXDSPRM-3-UNSUPPORTED_CODEC:

Y

N

Syslog
%FLEX_DNLD-3-ERROR_FIRMWARE_DNLD:

Y

N

Syslog
%FM-3-UNLOADING:

Y

N

Syslog
%FMANRP_ESS-3-ERREVENT:

Y

N

Syslog
%FMANRP_MCAST-3-FMANRP_UPDINTF:

Y

N

Syslog
%FMANRP_NAT-3-MIBEVENT:

Y

N

Syslog
%FPD_MGMT-3-MISSING_DEV_INFO:

Y

N

Syslog
%FPD_MGMT-3-CARD_DISABLED:

Y

N

Syslog
%FPD_MGMT-3-PKG_FILE_SEARCH_FAILED:

Y

N

Syslog
%FPD_MGMT-3-MAJOR_VER_MISMATCH:

Y

N

Syslog
%FPD_MGMT-3-INCOMP_IMG_VER:

Y

N

Syslog
%FRR_OCE-3-INVALIDPAR:

Y

N

Syslog
%AAAA-4-SERVNOGRP:

Y

N

Syslog
%AAAA-4-SERVNOTACPLUS:

Y

N

Syslog
%AAAA-4-UNSUPWAITSTART:

Y

N

Syslog
%AAL5-3-RXERR:

Y

Y

Syslog
%AAL5-3-RXERR_PAKTYPE:

Y

Y

Syslog
%ACE-3-CRASHDUMPERR:

Y

Y

Syslog
%ACE-3-HAPITRUNC:

Y

Y

Syslog
%ACE-3-INITFAIL:

Y

Y

Syslog
%AAA-3-ACCT_IOMEM_LOW:

Y

N

Syslog
%AAA-3-ACCT_LOW_MEM_UID_FAIL:

Y

N

Syslog
%AAA-3-BADMETHODERROR:

Y

N

Syslog
%AAA-3-BUFFER_OVERFLOW:

Y

N

Syslog
%AAA-3-LOW_MEM:

Y

N

Syslog
%AAA-3-BADHDL:

Y

N

Syslog
%AAA-3-PARSEERR:

Y

N

Syslog
%STANDBY-3-DUPADDR:

Y

Y

Syslog
%SYS-5-MOD_NOSCPPINGRESPONSE:

Y

Y

Syslog
%SYSTEM_CONTROLLER-3-MISTRAL_RESET:

Y

N

Syslog
%EARL_L2_ASIC-4-SRCH_ENG_FAIL:

Y

N

Syslog
%C6KPWR-4-UNDERPOWERED:

Y

N

Syslog
%STANDBY-3-DIFFVIP1:

Y

N

Syslog
%PM-4-ERR_DISABLE:

Y

Y

Syslog
%SYS-3-LOGGER_FLUSHED:

Y

N

Syslog
%PFREDUN-4-BOOTSTRING_INVALID:

Y

N

Syslog
%SM-4-BADEVENT:

Y

N

Syslog
%FABRIC-6-TIMEOUT_ERR:

Y

N

Syslog
%QM-4-TCAM_MASK:

Y

N

Syslog
%SYS-0-SYS_LCPERR\d*:

Y

Y

Syslog
%CONST_DIAG-3-HM_PORT_ERR:

Y

Y

Syslog
%SYS-4-SYS_LCPERR4:

Y

N

Syslog
%SPA_EEPROM-3-RPC_FAILED:

Y

N

Syslog
%DHCP_SNOOPING-5-DHCP_SNOOPING_UNTRUSTED_PORT:

Y

N

Syslog
%DHCP_SNOOPING-4-DHCP_SNOOPING_ERRDISABLE_WARNING:

Y

N

Syslog
%C6KENV-4-PSFANFAILED:

Y

Y

Syslog
%C6KENV-4-PSFANOK:

N

Y

Syslog
%C6KFIB-4-DISABLED:

Y

Y

Syslog
%C6KPWR-4-PSREDUNDANTONESUPPLY:

Y

Y

Syslog
%C6K_POWER-4-PD_NOLINKUP:

Y

Y

Syslog
%CHKPT-4-GET_HUGE_BUF:

Y

N

Syslog
%CONST_DIAG-4-ERROR_COUNTER_DATA:

Y

Y

Syslog
%CSM_SLB-4-REDUNDANCY_WARN:

Y

Y

Syslog
%DIAG-3-NO_DIAG_RUNNING:

Y

N

Syslog
%DIAG-6-SIMULATED_TEST_RESULT:

Y

N

Syslog
%DIAG-6-TEST_OK:

Y

N

Syslog
%DIAG-6-TEST_RUNNING:

N

N

Syslog
%EARL_L2_ASIC-4-DBUS_HDR_ERR:

Y

N

Syslog
%EARL_L2_ASIC-4-DBUS_HDR_ERR:

Y

Y

Syslog
%EARL_NETFLOW-4-TCAM_THRLD:

Y

N

Syslog
%EC-4-NOMEM:

Y

N

Syslog
%EC-5-BUNDLE:

Y

N

Syslog
%ENVM-4-LONGBUSYREAD:

Y

N

Syslog
%FABRIC-4-SYNC_FAILED:

Y

N

Syslog
%LACP-4-MULTIPLE_NEIGHBORS:

Y

N

Syslog
%LACP-4-MULTIPLE_NEIGHBORS:

Y

N

Syslog
%MLS_ACL_COMMON-4-MLS_ACL_CONSIST:

Y

Y

Syslog
%OSPF-4-BADLENGTH:

Y

N

Syslog
%OSPF-4-ERRRCV:

Y

Y

Syslog
%OSPF-4-ERRRCV:

Y

Y

Syslog
%OSPF-4-ERRRCV:

Y

N

Syslog
%OSPF-4-ERRRCV:

Y

N

Syslog
%OSPF-4-ERRRCV:

Y

N

Syslog
%OSPF-4-ERRRCV:

Y

N

Syslog
%OSPF-4-ERRRCV:

Y

Y

Syslog
%OSPF-4-FLOOD_WAR:

Y

N

Syslog
%OSPF-4-FLOOD_WAR:

Y

N

Syslog
%OSPF-4-FLOOD_WAR:

Y

N

Syslog
%OSPF-4-FLOOD_WAR:

Y

N

Syslog
%OSPF-4-FLOOD_WAR:

Y

N

Syslog
%OSPF-5-ADJCHG:

Y

N

Syslog
%PM-4-SVI_ADD_CORRESPONDING_L2_VLAN:

Y

N


Error Counters - Register Name

Alarm Type
Alarm Message Information
Notify
Create Service Request
Error Counters - Register Name
R2D2_PB2AR_CP_PA_BAD_PKT_CNT2
Y
N
Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT3

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT6

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT7

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT4

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT5

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT8

Y

N

Error Counters - Register Name

R2D2_PB2AR_CP_PA_BAD_PKT_CNT9

Y

N

Error Counters - Register Name

R2D2_ARIC_CP_DBUS_CRC_ERR__0

Y

N

Error Counters - Register Name

R2D2_ARIC_CP_DBUS_CRC_ERR__1

Y

N

Error Counters - Register Name

R2D2_ARIC_CP_CBL_PARITY_ERR__1

Y

Y

Error Counters - Register Name

R2D2_ARIC_CP_CBL_PARITY_ERR__0

Y

Y

Error Counters - Register Name

R2D2_ARIC_CP_SOFT_CRC_ERR__1

Y

Y

Error Counters - Register Name

R2D2_ARIC_CP_SOFT_CRC_ERR__0

Y

Y

Error Counters - Register Name

R2D2_ARIC_CP_DATA_CRC_ERR__1

Y

N

Error Counters - Register Name

R2D2_ARIC_CP_DATA_CRC_ERR__0

Y

N

Error Counters - Register Name

JA_DR_RI_0_HDRCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

JA_DR_RI_0_PKTCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

JA_DR_RI_1_HDRCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

JA_DR_RI_1_PKTCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

JA_FI_FR_CRC_PKT_ERR_1

Y

Y

Error Counters - Register Name

JA_FI_FR_CRC_HDR_ERR_1

Y

Y

Error Counters - Register Name

JA_FI_FR_CRC_PKT_ERR_0

Y

Y

Error Counters - Register Name

JA_FI_FR_RCV_ERR_1

Y

Y

Error Counters - Register Name

JA_FI_FR_RCV_ERR_0

Y

Y

Error Counters - Register Name

JA_TI_PG_BAD_PKT_CRC

Y

Y

Error Counters - Register Name

ME_AR_KIF_RX_PKTLEN_ERR_CNT

Y

Y

Error Counters - Register Name

ME_AR_KIF_RX_PKTMAXLEN_ERR_CNT

Y

Y

Error Counters - Register Name

ME_AR_KIF_RX_PKTCRC_ERR_CNT

Y

Y

Error Counters - Register Name

ME_AR_KIF_RX_CTL_ERR_CNT

Y

Y

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT0

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT1

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT2

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT3

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT4

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT5

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT6

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT7

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT8

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT9

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT10

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT11

Y

N

Error Counters - Register Name

RO_PB2AR_CP_PA_BAD_PKT_CNT12

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT0

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT1

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT2

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT3

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT4

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT5

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT6

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT7

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT8

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT9

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT10

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT11

Y

N

Error Counters - Register Name

RO_PB2N_CP_PN_BAD_PKT_CNT12

Y

N

Error Counters - Register Name

RO_CDL_CDL_HT

Y

N

Error Counters - Register Name

RO_CDL_CDL_HC

Y

N

Error Counters - Register Name

RO_ARIC_CP_SOFT_CRC_ERR

Y

Y

Error Counters - Register Name

RO_ARIC_CP_DATA_CRC_ERR

Y

Y

Error Counters - Register Name

RO_ARIC_CP_DBUS_CRC_ERR

Y

Y

Error Counters - Register Name

RO_ARIC_CP_MAX_LEN_ERR

Y

Y

Error Counters - Register Name

RO_ASIC_CP_MIN_LEN_ERR

Y

Y

Error Counters - Register Name

RO_ASIC_CP_FIFO_FULL_ERR

Y

N

Error Counters - Register Name

RO_ASIC_CP_LENGTH_ERR

Y

N

Error Counters - Register Name

RO_ASIC_CP_CBL_PARITY_ERR

Y

Y

Error Counters - Register Name

PI_CI_S_HDR_FCS_REG

Y

Y

Error Counters - Register Name

PI_CI_S_RBUS_FCS_REG

Y

Y

Error Counters - Register Name

PI_CI_S_PKTCRC_ERR_REG

Y

Y

Error Counters - Register Name

PI_CI_S_PKTLEN_ERR_REG

Y

Y

Error Counters - Register Name

PI_GM_S_TX_PARERR_REG

Y

Y

Error Counters - Register Name

PI_GM_S_INCRC_ERR_REG

Y

Y

Error Counters - Register Name

PI_PN_S_CRC_ERR_CNT_REG

Y

Y

Error Counters - Register Name

PI_PN_S_RBUS_ERR_CNT_REG

Y

Y

Error Counters - Register Name

PI_MS_TCRC

Y

N

Error Counters - Register Name

TE_FI_FR_CRC_PKT_ERR_1

Y

Y

Error Counters - Register Name

TE_FI_FR_CRC_HDR_ERR_1

Y

Y

Error Counters - Register Name

TE_FI_FR_CRC_PKT_ERR_0

Y

Y

Error Counters - Register Name

TE_FI_FR_CRC_PKT_ERR_0

Y

Y

Error Counters - Register Name

TE_FI_FR_RCV_ERR_1

Y

Y

Error Counters - Register Name

TE_FI_FR_RCV_ERR_0

Y

Y

Error Counters - Register Name

TE_LS_SV_DBUS_PKT_CRC_ERR_CNT

Y

Y

Error Counters - Register Name

TE_LS_SV_DBUS_HDR_CRC_ERR_CNT

Y

Y

Error Counters - Register Name

TE_TI_PR_HC_HC_BAD_DHDR_CRC

Y

Y

Error Counters - Register Name

TE_TI_PR_HC_HC_BAD_RHDR_FCS2

Y

N

Error Counters - Register Name

TE_TI_PG_BAD_PKT_CRC

Y

Y

Error Counters - Register Name

TE_FD_PG_PG_BAD_PKT_CRC

Y

N

Error Counters - Register Name

TE_FD_PG_HC_HC_BAD_DHDR_CRC

Y

Y

Error Counters - Register Name

TE_FD_PP_EC_EC_BAD_PKT_CRC

Y

N

Error Counters - Register Name

TE_LM_PP_EC_EC_BAD_PKT_CRC_TI

Y

Y

Error Counters - Register Name

TE_LM_PP_EC_EC_BAD_PKT_CRC_FI

Y

N

Error Counters - Register Name

TE_LM_PP_EC_EC_BAD_PKT_CRC_DDR

Y

Y

Error Counters - Register Name

TE_LM_PP_EC_EC_BAD_PKT_CRC_FD

Y

Y

Error Counters - Register Name

TE_DR_RI_CFG_HDRCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

TE_DR_RI_CFG_PKTCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

HY_FI_FR_CRC_PKT_ERR_1

Y

Y

Error Counters - Register Name

HY_FI_FR_CRC_HDR_ERR_1

Y

Y

Error Counters - Register Name

HY_FI_FR_CRC_PKT_ERR_0

Y

Y

Error Counters - Register Name

HY_FI_FR_CRC_PKT_ERR_0

Y

Y

Error Counters - Register Name

HY_FI_FR_RCV_ERR_1

Y

Y

Error Counters - Register Name

HY_FI_FR_RCV_ERR_0

Y

Y

Error Counters - Register Name

HY_LS_SV_DBUS_PKT_CRC_ERR_CNT

Y

Y

Error Counters - Register Name

HY_LS_SV_DBUS_HDR_CRC_ERR_CNT

Y

Y

Error Counters - Register Name

HY_TI_PR_HC_HC_BAD_DHDR_CRC

Y

Y

Error Counters - Register Name

HY_TI_PR_HC_HC_BAD_RHDR_FCS2

Y

Y

Error Counters - Register Name

HY_TI_PG_BAD_PKT_CRC

Y

Y

Error Counters - Register Name

HY_FD_PG_PG_BAD_PKT_CRC

Y

Y

Error Counters - Register Name

HY_FD_PG_HC_HC_BAD_DHDR_CRC

Y

Y

Error Counters - Register Name

HY_FD_PP_EC_EC_BAD_PKT_CRC

Y

Y

Error Counters - Register Name

HY_LM_PP_EC_EC_BAD_PKT_CRC_TI

Y

Y

Error Counters - Register Name

HY_LM_PP_EC_EC_BAD_PKT_CRC_FI

Y

Y

Error Counters - Register Name

HY_LM_PP_EC_EC_BAD_PKT_CRC_DDR

Y

Y

Error Counters - Register Name

HY_LM_PP_EC_EC_BAD_PKT_CRC_FD

Y

Y

Error Counters - Register Name

HY_DR_RI_CFG_HDRCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

HY_DR_RI_CFG_PKTCRC_ERR_COUNTER

Y

Y

Error Counters - Register Name

ME_LC_ERR_CNT_REG

Y

Y

Error Counters - Register Name

ME_FI_ERR_CNT0_REG

Y

Y

Error Counters - Register Name

ME_FI_ERR_CNT1_REG

Y

Y

Error Counters - Register Name

QC_CPU_CPUSM_STAT

Y

Y

Error Counters - Register Name

QC_PF1_CRC_ERR

Y

Y

Error Counters - Register Name

RC_CPU_CPUSM_STAT

Y

Y

Error Counters - Register Name

RC_BOC_STAT0

Y

Y

Error Counters - Register Name

PK_DDRPK_DDR_STATUS

Y

Y

Error Counters - Register Name

PK_TS_S_TCRC

Y

Y

Error Counters - Register Name

SP_CP_TUNE_INT_STATUS

Y

Y

Error Counters - Register Name

SP_CP_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SP_CP_INT_SUMMARY

Y

Y

Error Counters - Register Name

SP_CF_S_HDR_FCS_ERR

Y

Y

Error Counters - Register Name

SP_CF_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SP_CC_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SP_TW_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SP_RP_INT_PE

Y

Y

Error Counters - Register Name

SP_TI_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SP_RE_INT

Y

Y

Error Counters - Register Name

SP_CI_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

ST_BADPKT_DROP_CNT_L

Y

Y

Error Counters - Register Name

SC_CB_GEN_INT_STATUS

Y

Y

Error Counters - Register Name

SC_CB_DBUS_HDR_BADFCS

Y

Y

Error Counters - Register Name

SC_CP_INTERRUPT

Y

Y

Error Counters - Register Name

SC_QM_QM_PAYLOAD_CRCERR_CNT

Y

Y

Error Counters - Register Name

SC_PN_INTERRUPT

Y

Y

Error Counters - Register Name

SC_PN_FCS_ERR_CNT

Y

Y

Error Counters - Register Name

SC_PC_INTERRUPT

Y

Y

Error Counters - Register Name

SC_PC_CRC_ERR_CNT

Y

Y

Error Counters - Register Name

SC_GXMAC_TX_BAD_FRAME_CNT

Y

Y

Error Counters - Register Name

DS_LTL_IF_LTL_IF_PKT_CRC_ERR_CNTR

Y

Y

Error Counters - Register Name

DS_LTL_IF_LTL_IF_PKT_LEN_ERR_CNTR

Y

Y

Error Counters - Register Name

DS_CBOC_HI_PKTCRC_ERR

Y

Y

Error Counters - Register Name

DS_CBOC_LO_PKTCRC_ERR

Y

Y

Error Counters - Register Name

DS_CBIC_PKTCRC_ERR

Y

N

Error Counters - Register Name

DS_CBIC_PKTLEN_ERR

Y

N

Error Counters - Register Name

DS_CBIC_RBUS_FCS

Y

N

Error Counters - Register Name

DS_CBIF_HDR_FCS_ERR

Y

N


Catalyst 7200 and 7300

Environment

Syslogs

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature/Voltage alarm - Operating temperature has risen above the <Warning/Critical> threshold value.

Y

N

Environment

Fan number x failure (This failure is C7201 specific.) - One of router's cooling fans failed.

Y

N

Environment

Power supply state changes from x to y - One of the power supply test points underwent a state change.

Y

N

Environment

Power minor/major alarm on Power Supply x inserted/removed - change in power supply status due to the removal or insertion of a power supply module in the system.

Y

N

Environment

Recovery - Device has recovered form a previously raised environmental alarm.

Y

N

Environment

Temperature minor alarm on I/O controller

Y

N

Environment

Major Temperature alarm I/O Cont

Y

Y

Environment

Recovered: Module major alarm on Temp Sensor I/O Cont

Y

N

Environment

Minor Temperature alarm NPE

Y

N

Environment

Major Temperature alarm NPE

Y

Y

Environment

Recovered: Module major alarm on Temp Sensor NPE

Y

N

Environment

Minor Temperature alarm CPU Die

Y

N

Environment

Major Temperature alarm CPU Die

Y

Y

Environment

Recovered : Module major alarm on Temp Sensor CPU Die

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog
%ENVM-0-SHUTDOWN
Y
Y
Syslog

%CRYPTO-6-IKMP_NOT_ENCRYPTED

N

N

Syslog

%SCHED-0-WATCHDOG

Y

Y

Syslog

%SERIAL-0-DLL_OUTOFLOCK

Y

Y

Syslog

%CRYPTO-0-SELF_TEST_FAILURE

N

N

Syslog

%OER_MC-0-EMERG

Y

Y

Syslog

%SERIAL-0-BADPORT

Y

Y

Syslog

%SERIAL-0-INITFAIL

Y

Y

Syslog

%VPN_HW-0-SELF_TEST_FAILURE

Y

Y

Syslog

%ENVM-0-SHUT

Y

Y

Syslog

%GPRSFLTMG-0-GPRS_SERVICE

Y

Y

Syslog

%ENVM-0-STATUS_NOT_READY

Y

Y

Syslog

%SCHED-0-ISRWATCHDOG

Y

Y

Syslog

%CRYPTO-0-AUDITFAIL

Y

Y

Syslog

%ATMPA-0-BATMANERROR

Y

Y

Syslog

%MWAM-0-CORRECTABLE_ECC_ERR

Y

Y

Syslog

%PACC-0-INITFAIL

Y

Y

Syslog

%DAS_ENV-0-SHUTDOWN

Y

Y

Syslog

%GPRSFLTMG-0-GTPv1NORESOURCE

Y

Y

Syslog

%NETGX_CRYPTO-0-SELF_TEST_FAILURE

Y

Y

Syslog

%GPRSFLTMG-0-GPRS_DHCP

Y

Y

Syslog

%CRYPTO-0-SELF_TEST_FAILURE

Y

Y

Syslog

%GTP-0-GTPv1PACKETPARSINGERROR

Y

Y

Syslog

%GTP-0-NORESOURCE

Y

Y

Syslog

%PACC-0-DLL_OUTOFLOCK

Y

Y


Carrier Routing System (CRS)

Syslogs

Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog

FABRIC-FSDB-0-FABRIC_LOSS_LC_RELOAD

Y

Y

Syslog

%MGBL-CONFIG-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%FABRIC-FABQ-0-PRP3_FAULT_RECOVERY_ERR

Y

N

Syslog

%FABRIC-FABRICQ-1-ERR_ASIC_GENERIC

Y

N

Syslog

%FABRIC-FIA-0-ASIC_FATAL_FAULT

Y

Y

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_0

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_0

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-SUSTAINED_CRC_ERR

Y

Y

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_0

Y

N

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_1

Y

N

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_RACK_RELOAD

Y

N

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_ROUTER_RELOAD

Y

N

Syslog

%FABRIC-FSDB-1-ERR_PLANE_CONFIG

Y

N

Syslog

%FABRIC-FSDB-1-FABRIC_UPDOWN

Y

N

Syslog

%FABRIC-FSDB-1-PLANE_UPDOWN

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_ASIC_GENERIC\[\]

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_INIT\[\]

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERROR_HW_ACCESS\[\]Error

Y

N

Syslog

%HA-HA_WD-1-ABORTING\[\]\,Aborting\.

Y

N

Syslog

%HA-HA_WD-1-CPU_HOG_5

Y

N

Syslog

%HA-HA_WD-1-CURRENT_STATE

Y

N

Syslog

%HA-HA_WD-1-DISK_ALERT

Y

N

Syslog

%HA-REDCON-1-STANDBY_NOT_READY

Y

N

Syslog

%HA-REDCON-1-STANDBY_READY

Y

N

Syslog

%INFRA-SUB_UTIL-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%IP-PLATFORM_IPV4-1-DLERR\[\]

Y

N

Syslog

%L2-ATM_RM-1-SYSDB_ERR\[\]

Y

N

Syslog

%L2-EGRESSQ_HW_DLL-3-SBE_THR

Y

Y

Syslog

%L2-ether_spa_mac_error-1-RECOVERY_FAILED

Y

N

Syslog

%L2-LC-0-TESTEMERG

Y

N

Syslog

%L2-SPA_ETHER-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%L2-VPA_8P_GE-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-BADDEVOPEN

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-INIT_FAILED

Y

N

Syslog

%MGBL-CONFIG-0-INIT_FAILURE

Y

N

Syslog

%MGBL-TTY-0-ISSU_STDBY_CON_AVAILABLE STANDBY

Y

N

Syslog

%OS-QNET-0-EMG

Y

N

Syslog

%OS-SYSLOG-0-LOG_EMERG

Y

N

Syslog

%OS-SYSLOG-0-LOG_EMERG_OWNER_PLANE

Y

N

Syslog

%PKT_INFRA-spp-0-EMERG

Y

N

Syslog

%PLATFORM-ASM-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-ASM-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_0

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_O

Y

N

Syslog

%PLATFORM-CARD-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_A_FAILED

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_PWR_SEQ_FAILED

Y

Y

Syslog

%PLATFORM-CBC-1-SLOT_ID_CHANGE

Y

N

Syslog

%PLATFORM-CBC-1-VERSION_ERROR

Y

N

Syslog

%PLATFORM-CHP-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_BOARD_RELOAD\[\]\[\[\]\]

Y

Y

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_RELOAD_SYS\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_SHUTDOWN_BOARD\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-CIH-1-ASIC_ERROR_RELOAD_BOARD

Y

N

Syslog

%PLATFORM-COMMON-0-LC_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-COMMON-0-RSP_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700_DLL-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-EVT_INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INTR_INIT_ERROR

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK0

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK1

Y

N

Syslog

%PLATFORM-CROSSBAR-1-OUT_MEM_ERROR_LNK1

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK0

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK1

Y

N

Syslog

%PLATFORM-DIAGS-0-LC_NP_LOOPBACK_FAILED

Y

Y

Syslog

%PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED

Y

Y

Syslog

%PLATFORM-DISCOVERY-0-ERR ASIC-ERR

Y

N

Syslog

%PLATFORM-DSC-1-ERR_LOST_ALL_FABRIC_RACKS

Y

N

Syslog

%PLATFORM-ENVMON-0-CARD_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-0-CHASSIS_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-1-CANTSHUT

Y

N

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAILURE

Y

Y

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAULT

Y

Y

Syslog

%PLATFORM-ENVMON-1-FAN_REMOVE

Y

N

Syslog

%PLATFORM-ENVMON-1-PEM_REMOVE

Y

N

Syslog

%PLATFORM-ENVMON-1-SHUTDOWN

Y

N

Syslog

%PLATFORM-ENVMON-1-SPA_CANTSHUT

Y

Y

Syslog

%PLATFORM-ENVMON-1-SPA_SHUTDOWN

Y

Y

Syslog

%PLATFORM-FABARBITER-1-SERDES_ERROR

Y

N

Syslog

%PLATFORM-FABMGR-1-ARB_SERDES_FAIL

Y

N

Syslog

%PLATFORM-FABMGR-1-BAD_XBAR

Y

N

Syslog

%PLATFORM-FABMGR-1-PERSISTENT_SERDES_FAIL

Y

N

Syslog

%PLATFORM-FAN-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_E7_INFO

N

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_INFO

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-TW_INFO

N

N

Syslog

%PLATFORM-FFQ-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-GT_I2C-3-UNRECOVERABLE_BUS_HANG

Y

N

Syslog

%PLATFORM-I2C_MASTERSHIP-0-ARBITRATION_LOCK_UNAVAILABLE

Y

Y

Syslog

%PLATFORM-I2C-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_ACT_ERROR

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_PRESENT_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-0-FATAL_ERR_INTR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_PAR_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-CPU_PAR_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-DEV_VERSION_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_0

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_1

Y

N

Syslog

%PLATFORM-NFEA_PAL-1-FLOWEXP_LIMIT

Y

N

Syslog

%PLATFORM-NP-0-INIT_ERR

Y

N

Syslog

%PLATFORM-NP-0-NP_INIT_FAILURE

Y

Y

Syslog

%PLATFORM-NP-0-PEX_PARITY

Y

Y

Syslog

%PLATFORM-NP-0-TOP_INACTIVITY_WATCHDOG

Y

Y

Syslog

%PLATFORM-NP-0-TOP_PERSISTANT_LOCKUP_ERROR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-0-NO_ACTIVE_RSP

Y

Y

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_DIP4

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_PROT_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_CRC_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_DELM_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_CRC_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_ERR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-LBUS_PARITY_ERR

Y

N

Syslog

%PLATFORM-PFM-0-CARD_RESET_ABORTED

Y

N

Syslog

%PLATFORM-PFM-0-CARD_RESET_REQ

Y

Y

Syslog

%PLATFORM-PFM-0-GRACEFUL_CARD_RESET_TIMED_OUT

Y

N

Syslog

%PLATFORM-POWERMGR-1-POWER_MODE_WARN

Y

Y

Syslog

%PLATFORM-PRP_HW-1-NVRAM_LOW_BATTERY_ERROR

Y

Y

Syslog

%PLATFORM-PRP_HW-1-OIR_OUT

Y

N

Syslog

%PLATFORM-PSARB-1-WRONG_SLOT

Y

Y

Syslog

%PLATFORM-PWR_SUPPLY-0-FAULT

Y

N

Syslog

%PLATFORM-PWRMON-1-IDPROM_INVALID

Y

N

Syslog

%PLATFORM-PWRMON-1-ZERO_CAPACITY

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP0_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP1_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-FATAL_ERROR

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_0

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_1

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_CHAIN

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_ERR_CMD

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_INVALID_CMD

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_OFLOW

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_PROTO

Y

N

Syslog

%PLATFORM-REDDRV-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%PLATFORM-RSP_CPUCTRL-0-BOARD_SEATING_ERROR

Y

Y

Syslog

%PLATFORM-SHELFMGR-0-CHASSIS_SHUTDOWN

Y

Y

Syslog

%PLATFORM-SHELFMGR-1-ALL_FANTRAYS_OFF

Y

N

Syslog

%PLATFORM-SHELFMGR-1-BOTH_FC_REMOVED

Y

N

Syslog

%PLATFORM-SHELFMGR-1-NO_POWER_AVAIL

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-0-FATAL_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-ERP_ERROR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-MBIT_ECC_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-PARITY_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPA_FATAL_ISR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS1_ERROR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS3_ERROR

Y

N

Syslog

%PLATFORM-SYSLDR_RP-1-NODE_RELOAD_NOW

Y

N

Syslog

%PLATFORM-SYSLDR-1-PING_FAILURE

Y

N

Syslog

%PLATFORM-SYSLDR-1-PING_FAILURE_BOOT

Y

N

Syslog

%PLATFORM-SYSLDR-1-SELF_PING_FAILURE

Y

N

Syslog

%PLATFORM-TFQ-0-SW_INIT_ERR

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-ALM_EMERG

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-GRP_ALM_EMERG

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-ALM_ALERT

Y

N

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-GRP_ALM_ALERT

Y

N

Syslog

%SUBSCRIBER-DATABASE-0-INIT_FAILURE

Y

Y

Syslog

%SUBSCRIBER-DATABASE-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

L2-PLIM-1-ERR_HW_THRESHOLD_RELOAD_NODE

Y

N


GSR 12000

Environment

Syslogs

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

System minor alarm on x/y/CPU0 host__InletTemp temp x(C),th:y(C): indicates that the temperature has exceeded the minor threshold limit on <LOCATION>.

Y

N

Environment

System major alarm on x/y/CPU0 host__InletTemp temp x(C),th:y(C): indicates that the temperature has exceeded the major threshold limit on <LOCATION>.

Y

N

Environment

System critical alarm on x/y/CPU0 host__InletTemp temp x(C),th:y(C): indicates that the temperature has exceeded critical threshold limit on <LOCATION>.

Y

N

Environment

System minor alarm on 0/2/CPU0 host__MB_12V volt 13000mV,th:12840mV: indicates that a minor voltage alarm has occurred on <LOCATION>.

Y

N

Environment

System minor alarm on 0/2/1 spa-volt 130 ,th:120: indicates that a minor voltage alarm has occurred on <LOCATION>.

Y

N

Environment

System major alarm on 0/2/CPU0 host__MB_12V volt 13000mV,th:12840Mv: indicates that a major voltage alarm has occurred on the card <LOCATION>.

Y

N

Environment

System major alarm on 0/2/1 spa-volt 130: indicates that a major voltage alarm has occurred on the card <LOCATION> ,th:120

Y

N

Environment

System critical alarm on 0/2/CPU0 host__MB_12V volt 13000mV,th:12840Mv: indicates that a critical voltage alarm has occurred on the card <LOCATION>.

Y

Y

Environment

System critical alarm on 0/2/1 spa-volt 130 ,th:120: indicates that a critical voltage alarm has occurred on the card <LOCATION>.

Y

Y

Environment

Power minor alarm on 0/24/CPU0 pwrs-shl-fail 1 ,th:-2: indicates a minor alarm due to power-shelf failure.

Y

N

Environment

Power major alarm on 0/24/CPU0 pwrs-shl-fail 1 ,th:-2: indicates a major alarm due to power-shelf failure.

Y

N

Environment

Power critical alarm on 0/24/CPU0 pwrs-shl-fail 1 ,th:-2: indicates a critical alarm due to power-shelf failure.

Y

Y

Environment

Power minor alarm on 0/24/CPU0 pwrs-shl-fault 1 ,th:-2: indicates a minor alarm due to faulty power-shelf.

Y

N

Environment

Power major alarm on 0/24/CPU0 pwrs-shl-fault 1 ,th:-2: indicates a major alarm due to faulty power-shelf.

Y

N

Environment

Power critical alarm on 0/24/CPU0 pwrs-shl-fault 1 ,th:-2: indicates a critical alarm due to faulty power-shelf.

Y

Y

Environment

System minor alarm on 0/5/1 spa-temp 56 ,th:55: indicates a minor alarm that the SPA temperature on <LOCATION>has risen above the minor threshold limit.

Y

Y

Environment

System major alarm on 0/5/1 spa-temp 56 ,th:55: indicates that the SPA temperature on <LOCATION>has risen above the majorthreshold limit.

Y

Y

Environment

System critical alarm on 0/5/1 spa-temp 56 ,th:55: indicates that the SPA temperature on <LOCATION>has risen above the criticalthreshold limit.

Y

Y

Environment

System minor alarm on 0/2/CPU0 host__MB_12A curr 130A,th:128A: indicates that a minor alarm has occurred on <LOCATION> due to abnormal current condition.

Y

Y

Environment

System major alarm on 0/2/CPU0 host__MB_12A curr 130A,th:128A: indicates that a major alarm has occurred on <LOCATION> due to abnormal current condition.

Y

N

Environment

System critical alarm on 0/2/CPU0 host__MB_12A curr 130A,th:128A: indicates that a critical alarm has occurred on <LOCATION> due to abnormal current condition.

Y

Y

Environment

Power minor alarm on 0/24/CPU0 pwrs-nonop 1 ,th:-2: indicates a minor power alarm on <LOCATION>.

Y

N

Environment

Power major alarm on 0/24/CPU0 pwrs-nonop 1 ,th:-2: indicates a major power alarm on <LOCATION>.

Y

N

Environment

Power critical alarm on 0/24/CPU0 pwrs-nonop 1 ,th:-2: indicates a critical power alarm on <LOCATION>.

Y

Y

Environment

Power minor alarm on Fan slot 29 fans 1 ,th:1: indicates that the router's cooling fan on slot <SLOT>has malfunctioned.

Y

N

Environment

Power major alarm on Fan slot 29 fans 1 ,th:1: indicates that the router's cooling fan on slot <SLOT>has malfunctioned.

Y

Y

Environment

Power critical alarm on Fan slot 29 fans 1 ,th:1: indicates that the router's cooling fan on slot <SLOT>has malfunctioned.

Y

Y


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslog
%FABRIC-FABQ-0-PRP3_FAULT_RECOVERY_ERR
Y
N
Syslog

%FABRIC-FSDB-0-FABRIC_LOSS_LC_RELOAD

Y

Y

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INTR_INIT_ERROR

Y

N

Syslog

%PLATFORM-DIAGS-0-LC_NP_LOOPBACK_FAILED

Y

Y

Syslog

%PLATFORM-I2C_MASTERSHIP-0-ARBITRATION_LOCK_UNAVAILABLE

Y

Y

Syslog

%PLATFORM-NPUXBAR_BRIDGE-0-NO_ACTIVE_RSP

Y

Y

Syslog

%PLATFORM-PFM-0-CARD_RESET_REQ

Y

Y

Syslog

%PLATFORM-PWR_SUPPLY-0-FAULT

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP0_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-REDDRV-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_0

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_0

Y

Y

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAILURE

Y

Y

Syslog

%PLATFORM-ENVMON-1-SPA_CANTSHUT

Y

Y

Syslog

%PLATFORM-FABMGR-1-BAD_XBAR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-DEV_VERSION_ERROR

Y

N

Syslog

%PLATFORM-NFEA_PAL-1-FLOWEXP_LIMIT

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_DIP4

Y

N

Syslog

%PLATFORM-POWERMGR-1-POWER_MODE_WARN

Y

Y

Syslog

%PLATFORM-PWRMON-1-IDPROM_INVALID

Y

N

Syslog

%PLATFORM-SHELFMGR-1-BOTH_FC_REMOVED

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_A_FAILED

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPA_FATAL_ISR

Y

N

Syslog

%PLATFORM-SYSLDR_RP-1-NODE_RELOAD_NOW

Y

N

Syslog

%PLATFORM-SYSLDR-1-PING_FAILURE_BOOT

Y

N

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_1

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-INIT_FAILED

Y

N

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_1

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_1_XAUI_RDY_3

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_1

Y

Y

Syslog

%PKT_INFRA-spp-0-EMERG

Y

N

Syslog

%PLATFORM-ASM-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_RELOAD_SYS\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-FFQ-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_ACT_ERROR

Y

N

Syslog

%PLATFORM-NP-0-PEX_PARITY

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_1

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-0-FATAL_ERROR

Y

Y

Syslog

%PLATFORM-TFQ-0-SW_INIT_ERR

Y

Y

Syslog

%FABRIC-FIA-1-SUSTAINED_CRC_ERR

Y

Y

Syslog

%PLATFORM-FABMGR-1-PERSISTENT_SERDES_FAIL

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-TW_INFO

N

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_ERROR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_CRC_ERR

Y

N

Syslog

%HA-HA_WD-1-CURRENT_STATE

Y

N

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_0

Y

Y

Syslog

%HA-HA_WD-1-DISK_ALERT

Y

N

Syslog

%FABRIC-FSDB-1-PLANE_UPDOWN

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_0

Y

Y

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_2

Y

Y

Syslog

%L2-EGRESSQ_HW_DLL-3-SBE_THR

Y

Y

Syslog

%OS-SYSLOG-0-LOG_EMERG_OWNER_PLANE

Y

N

Syslog

%PLATFORM-COMMON-0-LC_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-ENVMON-0-CARD_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-LC_CPUCTRL-0-NO_RSP_PRESENT_ERROR

Y

N

Syslog

%PLATFORM-NP-0-TOP_INACTIVITY_WATCHDOG

Y

Y

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-FATAL_ERROR

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_3_FAIL_1

Y

Y

Syslog

%PLATFORM-ENVMON-1-SHUTDOWN

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_3

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-CPP_PKT_PROT_ERR

Y

N

Syslog

%PLATFORM-PRP_HW-1-NVRAM_LOW_BATTERY_ERROR

Y

Y

Syslog

%FABRIC-FSDB-1-ERR_PLANE_CONFIG

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERROR_HW_ACCESS\[\]Error

Y

N

Syslog

%IP-PLATFORM_IPV4-1-DLERR\[\]

Y

N

Syslog

%HA-HA_WD-1-ABORTING\[\]\,Aborting\.

Y

N

Syslog

%L2-VPA_8P_GE-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_INIT\[\]

Y

N

Syslog

%MGBL-CONFIG-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%OS-SYSLOG-0-LOG_EMERG

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_BOARD_RELOAD\[\]\[\[\]\]

Y

Y

Syslog

%PLATFORM-CPUCTRL_SIP700_DLL-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_ECSR_0

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_ERR_CMD

Y

N

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-ALM_EMERG

Y

Y

Syslog

%FABRIC-FABRICQ-1-ERR_ASIC_GENERIC

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-TEMP_TOO_HIGH_0

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_0

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_0

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_INFO

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_CRC_ERR

Y

N

Syslog

%PLATFORM-PSARB-1-WRONG_SLOT

Y

Y

Syslog

%PLATFORM-PWRMON-1-ZERO_CAPACITY

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS3_ERROR

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK1

Y

N

Syslog

%PLATFORM-DSC-1-ERR_LOST_ALL_FABRIC_RACKS

Y

N

Syslog

%L2-ATM_RM-1-SYSDB_ERR\[\]

Y

N

Syslog

%L2-ether_spa_mac_error-1-RECOVERY_FAILED

Y

N

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_SCH_MEMP_ERR_3

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_1

Y

Y

Syslog

%PLATFORM-CHP-0-FAULT_RECOVERY_ERR

Y

N

Syslog

%PLATFORM-CIH-0-ASIC_ERROR_SHUTDOWN_BOARD\[\]\[\[\]\]

Y

N

Syslog

%PLATFORM-DISCOVERY-0-ERR ASIC-ERR

Y

N

Syslog

%PLATFORM-ENVMON-0-CHASSIS_OVERTEMP_SHUTDOWN

Y

N

Syslog

%PLATFORM-FAN-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-0-FATAL_ERR_INTR

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_CHAIN

Y

N

Syslog

%SUBSCRIBER-DATABASE-0-INIT_FAILURE

Y

Y

Syslog

%SUBSCRIBER-DATABASE-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_1

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_1_FAIL_0

Y

Y

Syslog

%PLATFORM-ENVMON-1-ENV_POWER_FAULT

Y

Y

Syslog

%PLATFORM-ENVMON-1-PEM_REMOVE

Y

N

Syslog

%PLATFORM-FAULT_MGR-1-MSG_E7_INFO

N

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-LBUS_PARITY_ERR

Y

N

Syslog

%PLATFORM-PRP_HW-1-OIR_OUT

Y

N

Syslog

%PLATFORM-SHELFMGR-1-ALL_FANTRAYS_OFF

Y

N

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-ALM_ALERT

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK0

Y

N

Syslog

%FABRIC-INGRESSQ_DLL-1-ERR_ASIC_GENERIC\[\]

Y

N

Syslog

%HA-REDCON-1-STANDBY_NOT_READY

Y

N

Syslog

%FABRIC-FSDB-1-FABRIC_UPDOWN

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_RX_ALIGN_LOSS_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_2

Y

Y

Syslog

%PLATFORM-BRIDGE-1-NPU_0_XAUI_RDY_3

Y

Y

Syslog

%PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED

Y

Y

Syslog

%PLATFORM-ASM-0-SW_INIT_ERR

Y

N

Syslog

%PLATFORM-I2C-0-ARBITRATION_LOCK_UNAVAILABLE

Y

N

Syslog

%PLATFORM-NP-0-TOP_PERSISTANT_LOCKUP_ERROR

Y

N

Syslog

%PLATFORM-PFM-0-GRACEFUL_CARD_RESET_TIMED_OUT

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_INVALID_CMD

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_OFLOW

Y

N

Syslog

%PLATFORM-SHELFMGR-0-CHASSIS_SHUTDOWN

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-0-GRP_ALM_EMERG

Y

Y

Syslog

%FABRIC-FIA-1-ARB_SERDES_0_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_0

Y

N

Syslog

%PLATFORM-ENVMON-1-CANTSHUT

Y

N

Syslog

%PLATFORM-ENVMON-1-FAN_REMOVE

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-CPU_PAR_ERROR

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-ERP_PAR_ERROR_1

Y

N

Syslog

%PLATFORM-SHELFMGR-1-NO_POWER_AVAIL

Y

Y

Syslog

%PLATFORM-CBC-1-VERSION_ERROR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-ERP_ERROR

Y

N

Syslog

%PLATFORM-SYSLDR-\d+-PING_FAILURE

Y

N

Syslog

%PLATFORM-SYSLDR-1-SELF_PING_FAILURE

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_HDR_ERR

Y

N

Syslog

%MEDIA-FLASHFS_HES-1-BADDEVOPEN

Y

N

Syslog

%PLATFORM-BRIDGE-1-QDR_MEM_ECC_FAIL_0

Y

Y

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_RACK_RELOAD

Y

N

Syslog

%FABRIC-FSDB-0-BARRIER_STALL_ROUTER_RELOAD

Y

N

Syslog

%OS-QNET-0-EMG

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-EVT_INIT_ERROR

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-INT_HT0_PROTO

Y

N

Syslog

%PLATFORM-RSP_CPUCTRL-0-BOARD_SEATING_ERROR

Y

Y

Syslog

%FABRIC-FIA-1-ARB_SERDES_1_FAIL_1

Y

N

Syslog

%FABRIC-FIA-1-DATA_SERDES_0_FAIL_0

Y

Y

Syslog

%FABRIC-FIA-1-DATA_SERDES_2_FAIL_1

Y

Y

Syslog

%PLATFORM-FABMGR-1-ARB_SERDES_FAIL

Y

N

Syslog

%PLATFORM-LC_QFPCPUCTRL-1-BOARD_REV_PAR_ERROR

Y

N

Syslog

%PLATFORM-NPUXBAR_BRIDGE-1-EBS_OC_DELM_ERR

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-PARITY_ERROR

Y

Y

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-SPI_BUS1_ERROR

Y

N

Syslog

%PLATFORM-CROSSBAR-1-IN_MEM_ERROR_LNK1

Y

N

Syslog

%PLATFORM-CROSSBAR-1-SERDES_ERROR_LNK0

Y

N

Syslog

%L2-PLIM-1-ERR_HW_THRESHOLD_RELOAD_NODE

Y

N

Syslog

%HA-REDCON-1-STANDBY_READY

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

Y

Syslog

%FABRIC-FIA-0-ASIC_FATAL_FAULT

Y

Y

Syslog

%INFRA-SUB_UTIL-0-INIT_RETRY_SUCCEEDED

Y

N

Syslog

%L2-LC-0-TESTEMERG

Y

N

Syslog

%MGBL-CONFIG-0-INIT_FAILURE

Y

N

Syslog

%MGBL-TTY-0-ISSU_STDBY_CON_AVAILABLE STANDBY

Y

N

Syslog

%PLATFORM-COMMON-0-RSP_HEADLESS_ACT_RSP_HB_REQ_FAILURE

Y

N

Syslog

%PLATFORM-CPUCTRL_SIP700-0-INIT_ERROR

Y

N

Syslog

%PLATFORM-CARD-0-OVERCURRENT

Y

N

Syslog

%PLATFORM-NP-0-INIT_ERR

Y

N

Syslog

%PLATFORM-NP-0-NP_INIT_FAILURE

Y

Y

Syslog

%PLATFORM-PFM-0-CARD_RESET_ABORTED

Y

N

Syslog

%PLATFORM-QFPCPUBridgeFPGA-0-CPP1_FATAL_ERROR

Y

Y

Syslog

%PLATFORM-ENVMON-1-SPA_SHUTDOWN

Y

Y

Syslog

%PLATFORM-FABARBITER-1-SERDES_ERROR

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_STAT_VEC_O

Y

N

Syslog

%PLATFORM-CBC-1-CANBUS_PWR_SEQ_FAILED

Y

Y

Syslog

%PLATFORM-CBC-1-SLOT_ID_CHANGE

Y

N

Syslog

%PLATFORM-SPAQFPBridgeCtrl-1-MBIT_ECC_ERROR

Y

Y

Syslog

%SERVICES-PERF_TRAFFIC_ALERT-1-GRP_ALM_ALERT

Y

N

Syslog

%PLATFORM-CIH-1-ASIC_ERROR_RELOAD_BOARD

Y

N

Syslog

%PLATFORM-CROSSBAR-1-OUT_MEM_ERROR_LNK1

Y

N

Syslog

%HA-HA_WD-1-CPU_HOG_5

Y

N

Syslog

%L2-SPA_ETHER-1-LTRACE_INIT_ERR\[\]

Y

N

Syslog

%PLATFORM-BRIDGE-1-XAUI_0_MGT_CV_3

Y

N


ISR Series

ISR (800, 2800, 3800, 1900, 2900, 3900)

Environment

Syslogs

Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

System minor alarm on Temperature Sensor - Overheated (C861, C881, 881SRST, 888, 891, IAD886, C1803, 1812).

Y

N

Environment

System critical alarm on Outlet Temperature Sensor - Overheated (C1861).

Y

N

Environment

System critical alarm on Temperature Sensor - Overheated (C2811, 2821, 2851).

Y

N

Environment

System minor alarm on Fan - Failed (C861, C881, 881SRST, 888, 891, IAD886, C1803, 1812, C1861).

Y

N

Environment

System minor alarm on Fan 2 - Failed (C1841, 2801, IAD2801, 1805, C2811, 2821, 2851, C3825, 3845).

Y

N

Environment

System notification alarm on Power Over Ethernet - Down (C881, 881SRST, 888, 891, IAD886).

Y

Y

Environment

System warning alarm on RTC - Out of battery (C1803, 1812, C1841, 2801, IAD2801, 1805, C1803, 1812).

Y

N

Environment

System critical alarm on Inlet Temperature Sensor - Overheated (c1861).

Y

N

Environment

System minor alarm on -48V power supply - Failed (C1861).

Y

N

Environment

System notification alarm on -48V power supply - Failed (C2811, 2821, 2851).

Y

N

Environment

System minor alarm on -12V power supply - Failed (C1861).

Y

N

Environment

System notification alarm on Redundant Power Supply - Standby/faulty (C2811, 2821, 2851, C3825, 3845).

Y

Y

Environment

System notification alarm on Redundant Power Supply - Removed (C2811, 2821, 2851, C3825, 3845).

Y

N

Environment

System notification alarm on Redundant Power Supply - Not available (C2811, 2821, 2851, C3825, 3845).

Y

N

Environment

System minor alarm on Voltage Sensor 4 - Exceeded warning threshold (C3825, 3845).

Y

N

Environment

System minor alarm on Voltage Sensor 4- Exceeded critical threshold (C3825, 3845).

Y

N

Environment

System minor alarm on Voltage Sensor 4 - High voltage, system down (C3825, 3845).

Y

N

Environment

System critical alarm on Temperature Sensor - Exceeded threshold (C3825, 3845).

Y

N

Environment

System critical alarm on System Power Supply 2 - Thermal warning (C3825, 3845).

Y

N

Environment

System minor alarm on System Power Supply 2 - Multiple failures detected (C3825, 3845).

Y

Y

Environment

System minor alarm on System Power Supply 2- Input voltage failed (C3825, 3845).

Y

N

Environment

System minor alarm on System Power Supply 2 - DC output voltage failed (C3825, 3845).

Y

Y

Environment

System minor alarm on Auxiliary (-48V) Power Supply 2 - Failed (C3825, 3845).

Y

Y

Environment

System minor alarm on System Power Supply 2 Fan - Failed (C3825, 3845).

Y

N

Environment

System minor alarm on System Power Unit - Wrong RPS is coNected (C1941, 2901, C2911, c2951, c39451).

Y

N

Environment

System critical alarm on System Power Unit - Wrong RPS or not coNected correctly (C1941, 2901, C2911, c2951, c39451).

Y

N

Environment

System minor alarm on System Power Unit - Both RPS FRUs need to be the same (C1941, c2901, C2911, c2951, c39451).

Y

N

Environment

System minor alarm on System Power Unit - PS in RPS are incompatible (C1941, 2901, C2911, c2951, c39451).

Y

N

Environment

System critical alarm on System Power Unit - RPS is not available for backup (C1941, 2901, C2911, c2951, c39451).

Y

Y

Environment

System major alarm on System Fan - Fan failed (C1941, 2901).

Y

Y

Environment

System major alarm on System Power Unit - RPS temperature in warning state (C1941, 2901, C2911, c2951, c39451).

Y

N

Environment

System critical alarm on System Power Unit - RPS temperature in critical state (C1941, 2901, C2911, c2951, c39451).

Y

N

Environment

System critical alarm on System Power Unit - RPS fan failed (C1941, 2901, C2911, 2951, 3945).

Y

Y

Environment

System critical alarm on System Power Unit - DiscoNected or powered off (C1941, 2901, C2911, 2951, 3945).

Y

N

Environment

System minor alarm on System Power Unit - RPS POST failed (C1941, 2901, C2911, 2951, 3945).

Y

Y

Environment

System critical alarm on System Power Unit - RPS OIR insertion not supported (C1941, 2901, C2911, 2951, 3945).

Y

N

Environment

System critical alarm on System Power Unit - RPS is not ready for configuration (C1941, 2901, C2911, 2951, 3945).

Y

Y

Environment

System major alarm on Inlet Outlet Temperature Sensor - Right Intake 58C exceeds 57C limit (C2911, 2951, 3945).

Y

N

Environment

System major alarm on Inlet Outlet Temperature Sensor - Right Exhaust 76C exceeds 75C limit (C2911, 2951, 3945).

Y

N

Environment

System major alarm on System Power Unit - PSU2 96C exceeds threshold 95C (C2911, 2951, 3945).

Y

N

Environment

System major alarm on Inlet Outlet Temperature Sensor - Left Intake 58C exceeds 57C limit (C2911, 2951, 3945).

Y

N

Environment

System major alarm on Inlet Outlet Temperature Sensor - Left Exhaust 76C exceeds 75C limit (C2911, 2951, 3945).

Y

N

Environment

System critical alarm on CPU Temperature Sensor - 116C exceeds 115C limit (C2911, 2951, 3945).

Y

N

Environment

System critical alarm on CPU Temperature Sensor - 116C exceeds 115C limit; Sys down (C2911, 2951, 3945).

Y

N

Environment

System critical alarm on System Power Unit - Internal PSU 2 removed (C2911, 2951, 3945).

Y

N

Environment

System minor alarm on System Power Unit - Internal PSU 2 POE power failed (C2911, 2951, 3945).

Y

N

Environment

System minor alarm on Fan Tray Fan 5 - Failed (C2911, 2951, 3945).

Y

Y

Environment

System minor alarm on Fan Tray - Two fan failed; Replace fan tray (C2911, 2951, 3945).

Y

Y

Environment

System major alarm on Fan Tray - Multi fan failed; Replace fan tray (C2911, 2951, 3945).

Y

Y

Environment

System major alarm on Fan Tray - Fan tray is missing (C2911, 2951, 3945).

Y

Y

Environment

Recovered : System normal alarm on System Fan - Fan is normal now.

N

N

Environment

Recovered : System normal alarm on Fan Tray Fan 5 - OK.

N

N

Environment

Recovered : System normal alarm on Fan Tray - Fan tray is detected.

N

N

Environment

Recovered : System normal alarm on Inlet Outlet Temperature Sensor - Right Intake normal.

N

N

Environment

Recovered : System normal alarm on System Power Unit - PSU2 temperature is normal.

N

N

Environment

Recovered : System normal alarm on CPU Temperature Sensor - Temperature is normal.

N

N

Environment

Recovered : System normal alarm on System Power Unit - Internal PSU 2 POE power is restored.

N

N


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslog
%C870_FE-2-NOISL
Y
N
Syslog

%C870_FE-1-SHOWFAIL

Y

N

Syslog

%C870_FE-1-TXERR

Y

N

Syslog

%PLATFORM-2-CIU_ALLOC_ERR

Y

N

Syslog

%PLATFORM-2-CIU_ENA_ERR

Y

N

Syslog

%PLATFORM-2-CIU_DEALLOC_ERR

Y

N

Syslog

%NVRAM-2-NO_GOOD_SECTORS

Y

Y

Syslog

%DSPRM-3-DSPALARM

Y

Y

Syslog

%C5510-1-NO_RING_DESCRIPTORS

Y

Y

Syslog

%C870_FE-1-INITFAILP

Y

Y

Syslog

%IOCTRL-1-I2C_ERROR

Y

N

Syslog

%PLATFORM-2-PHY_CONFIG

Y

Y

Syslog

%MAINBOARD-2-PARITY

Y

N

Syslog

%CCH323-2-GTWY_REGSTR_FAILED_ALT_GK

Y

N

Syslog

%CCH323-2-GTWY_REGSTR_FAILED

Y

N

Syslog

%C870_HW_CRYPTO-0-SEC_KAT_FAILURE

Y

N

Syslog

%PQ3_TSEC-1-GRSFAIL

Y

N

Syslog

%VENOM-1-CARD_NOT_SUPPORTED

Y

N

Syslog

%DXMRVL_STORM_CONTROL-2-SHUTDOWN

Y

N

Syslog

%ENVMON-1-SYSTEM_FAN_FAILED_SHUTDOWN

Y

N

Syslog

%ENVMON-1-CPU_CRITICAL_OVERTEMP

Y

N

Syslog

%NVRAM-2-INIT_STAT_FAILED

Y

Y

Syslog

%MAINBOARD-2-SCCFAIL

Y

N

Syslog

%MAINBOARD-2-SCC_STI_ERR

Y

N

Syslog

%SERVICEMODULE-2-IPCONFIGFAILED

Y

N

Syslog

%PQ3_TSEC_BACKPLANE-1-INITFAIL

Y

N

Syslog

%IOCTRL-1-TIMER_NO_START

Y

N

Syslog

%WLAN_AP_INTF-1-CREATE_INTERFACE

Y

N

Syslog

%WLAN_AP_SM-1-INITFAIL

Y

N

Syslog

%PLATFORM-1-SPUR_INT

Y

N

Syslog

%PLATFORM-1-UNRECOGNIZED_BOARD_TYPE

Y

N

Syslog

%VENOM-1-FIRMWARE_DOWNLOAD_FAILURE

Y

N

Syslog

%SECONDCORE-2-INVALIDEVENT

Y

N

Syslog

%ENVMON-1-POWER_WARNING

Y

N

Syslog

%ENVMON-2-FAN_TRAY_MISSING

Y

Y

Syslog

%ENVMON-1-FAN_TRAY_MISSING_SHUTDOWN

Y

N

Syslog

%ENVMON-2-SYSTEM_FAN_FAILED

Y

N

Syslog

%ENVMON-2-ONE_FAN_FAILED

Y

Y

Syslog

%SFP-1-FAILURE

Y

Y

Syslog

%SFP-1-NOT_IDENTIFIED

Y

Y

Syslog

%PLATFORM-2-SM_ERROR

Y

Y

Syslog

%MAINBOARD-0-ECC_MULTIPLE

Y

N

Syslog

%MAINBOARD-2-MSI_PARA_ERR

Y

N

Syslog

%MAINBOARD-2-HDLC_STI_ERR

Y

N

Syslog

%MAINBOARD-2-HWIC_CRC_ERR

Y

N

Syslog

%DSPRM-2-DSPALARM

Y

Y

Syslog

%ENVMON-1-WARN_DOWN_REV_ROMMON

Y

N

Syslog

%C870_FE-1-MACADDRFAIL

Y

N

Syslog

%IOCTRL-1-SPI_ERROR

Y

N

Syslog

%BPSM_ERROR-2-BPSM_INTERNAL_ERR

Y

N

Syslog

%PLATFORM-2-FPA_MEM_ERR

Y

N

Syslog

%NVRAM-2-INIT_STAT_ERASE_FAILED

Y

Y

Syslog

%C5510-1-C5510_HPI_TIMEOUT

Y

Y

Syslog

%ENVMON-3-OVERTEMP_OK

Y

N

Syslog

%C3800_ENVM-1-PS_THERMAL

Y

N

Syslog

%IOCTRL-1-SCC_DMA_ERROR

Y

N

Syslog

%IOCTRL-1-GPIO_ERROR

Y

N

Syslog

%IOCTRL-1-HSIB_ERROR

Y

N

Syslog

%SSLVPN-1-LICENSE_EXPIRED

Y

N

Syslog

%PLATFORM-2-CIU_DIS_ERR

Y

N

Syslog

%VENOM-1-INITFAIL

Y

N

Syslog

%PLATFORM-2-BOOT_BUS_ERR

Y

Y

Syslog

%ENVMON-1-MULTI_FAN_FAILED_SHUTDOWN

Y

Y

Syslog

%ENVMON-2-MULTI_FAN_FAILED

Y

Y

Syslog

%NVRAM-4-ERASE_INT_LEVEL

Y

Y

Syslog

%MAINBOARD-2-INVALID_TXRX

Y

N

Syslog

%MAINBOARD-2-MSI_ALLOC_ERR

Y

N

Syslog

%MAINBOARD-2-HDLC_ERR

Y

N

Syslog

%PLATFORM-0-NM_REMOVED_SM2NM

Y

N

Syslog

%C5510-1-C5510_CHPI_ERROR

Y

Y

Syslog

%PLATFORM-0-SURPRISE_OIR

Y

N

Syslog

%HDV2-1-INITFAIL

Y

N

Syslog

%PLATFORM-2-CIU_INV_TYPE

Y

N

Syslog

%ENVMON-1-NO_PROCESS

Y

N

Syslog

%ENVMON-1-CPU_WARNING_OVERTEMP

Y

N

Syslog

%DXMRVL_DRV_ERR-2-DXMRVL_DRV_INTER_ERR

Y

Y

Syslog

%MAINBOARD-2-INITFAIL

Y

Y

Syslog

%MAINBOARD-2-MSI_DEALLOC_ERR

Y

N

Syslog

%WLAN_CONTROLLER-1-INITFAIL

Y

Y

Syslog

%LICENSE-2-UNRECOVERABLE

Y

N

Syslog

%C1800_HW_CRYPTO-0-SEC_KAT_FAILURE

Y

N

Syslog

%C1800-1-NOWICOUNTRYCODE

Y

Y

Syslog

%C3800_ENVM-1-BP_THERMAL

Y

N

Syslog

%PLATFORM-2-NO_POLL_TIMER

Y

N

Syslog

%PLATFORM-2-ISR_ERR_MSG

Y

N

Syslog

%PLATFORM-0-PCIE_ERR

Y

Y

Syslog

%SECONDCORE-2-BOOTERROR

Y

Y

Syslog

%ENVMON-2-OVERTEMP

Y

N

Syslog

%MAINBOARD-1-UNKNOWN_WIC

Y

Y

Syslog

%IVR-1-APP_PARALLEL_INVALID_LIST

Y

N


MDS 9000

Diagnostics

Environment

Syslogs

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

RMON_ALERT - The monitored object value is above or below the configured threshhold value.

Y

N

Diagnostics

SUP_FAILURE - The standby supervisor failed to boot up.

Y

Y

Diagnostics

SUP_FAILURE sup failure caused switchover

Y

Y

Diagnostics

LINECARD_FAILURE - All ports on this module will be unusable until the failure is cleared.

Y

Y

Diagnostics

PORT_FAILURE - A hardware failure has occurred on the Interface.

Y

N

Diagnostics

SW_CRASH - A service has terminated its execution abnormally and a syslog message is recorded.

Y

Y

Diagnostics

SW_SYSTEM_INCONSISTENT - An Upgrade process is aborted without user requesting an abort and/or due to an error.

Y

N

Diagnostics

BOOTFLASH_FAILURE - Bootflash on the active supervisor module failed and a switchover is forced.

Y

Y

Diagnostics

EOBC_FAILURE - An EOBC failure occured on the active supervisor and a switchover is forced.

Y

Y

Diagnostics

INBAND_FAILURE - Inband coNectivity failed on the module <module_no>.

Y

Y

Diagnostics

POWER_UP_DIAGNOSTICS_FAILURE - This alarm is generated when the linecard fails to bootup after it is powered up successfully.

Y

Y

Diagnostics

NAME_SERVER_DATABASE_FULL - Generated when the name server database has maximum allowed device entries in the fabric and a new a host or target tries to register itself to name server.

Y

Y

Diagnostics

NVRAM_FAILURE - Non-Volatile memory corrupted or failed on supervisor module.

Y

Y

Diagnostics

FREEDISK_FAILURE - Indicate that the " /tmp" diectory can be full or near full.

Y

Y

Diagnostics

MGMT_PORT_FAILURE (SUP_FAILURE Management ethernet chaNel failed).

Y

Y


Environment

Alarm Type
Alarm Message Information
Notify
Create Service Request
Environment
FAN_FAILURE: Fan module number x failed.
Y
Y
Environment

POWER_SUPPLY_FAILURE: This is a temperature alarm message for module x.

Y

Y

Environment

TEMPERATURE_ALARM: This is a temperature alarm message for module x.

Y

N

Environment

TEMPERATURE_MAJOR_ALARM Major Temperature Alarm for module x.

Y

N

Environment

TEMPERATURE_MINOR_ALARM Minor Temperature Alarm for module x

Y

N

Environment

TEMPERATURE_MAJOR_ALARM Recovered: Major Temperature Alarm for module x.

Y

N

Environment

TEMPERATURE_MINOR_ALARM Recovered: Minor Temperature Alarm for module x.

Y

N

Environment

TEMPERATURE_ALARM Temperature Sensor Failure for module 6

Y

Y


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslog
%PORT-5-IF_DOWN_NONE
Y
N
Syslog

%PORT-5-IF_DOWN_SOFTWARE_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_LINK_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_RCF_IN_PROGRESS

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_LOOPBACK_DETECTED

Y

N

Syslog

%PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_MODE

Y

N

Syslog

%PORT-5-IF_DOWN_SUSPENDED_BY_MODE

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_PORT_VSAN_MISMATCH_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_PEER_RESET

Y

N

Syslog

%PORT-5-IF_DOWN_TOO_MANY_INVALID_FLOGIS

Y

N

Syslog

%PORT-5-IF_DOWN_INVALID_FABRIC_BINDING

Y

N

Syslog

%PORT-5-IF_DOWN_OHMS_EXTERNAL_LB_TEST

Y

N

Syslog

^[LICENSE_VIOLATION]*License for feature

Y

N

Syslog

%PORT-5-IF_DOWN_ERROR_DISABLED

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_RATOV_EDTOV_MISMATCH

Y

N

Syslog

%PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_SPEED

Y

N

Syslog

%PORT-5-IF_DOWN_LOOPBACK_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_PORT_BIND_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_FABRIC_BIND_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_PORT_ACT_LICENSE_NOT_AVAILABLE

Y

N

Syslog

%PORT-5-IF_UP

N

N

Syslog

%PORT-5-IF_DOWN_HW_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_CHANNEL_MEMBERSHIP_UPDATE_IN_PROGRESS

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_TX_BBCREDIT

Y

N

Syslog

%PORT-5-IF_TRUNK_UP

Y

N

Syslog

%PORT-5-IF_DOWN_TCP_PERSIST_TIMER_EXPIRED

Y

N

Syslog

%PORT-5-IF_DOWN_DENIED_DUE_TO_PORT_BINDING

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_NOT_ALLOWED_ISOLATION

Y

N

Syslog

%PORT-5-IF_BRINGUP_NOT_ALLOWED_PORT_CONFIG_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_INACTIVE

Y

N

Syslog

%PORT-5-IF_DOWN_CHANNEL_ADMIN_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_CLASSN_PARAM_ERR

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_SWITCH_NAME

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_UPGRADE_IN_PROGRESS

Y

N

Syslog

%PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBBCREDIT

Y

N

Syslog

%PORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_TCP_MAX_RETRANSMIT

Y

N

Syslog

%PORT-5-IF_DOWN_TOO_MANY_INTR

Y

N

Syslog

%PORT-5-IF_DOWN_FICON_VSAN_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_INVALID_ATTACHMENT

Y

N

Syslog

%PORT-5-IF_DOWN_BUNDLE_MISCFG

Y

N

Syslog

%PORT-5-MODULE_BRINGUP_NOT_ALLOWED

Y

N

Syslog

^%PORT-5-IF_DOWN_NONE

Y

N

Syslog

%PORT-5-IF_DOWN_OFFLINE

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_REVISION_MISMATCH

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_PAYLOAD_SIZE

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_ADDR_ASSIGN_FAILURE_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED

Y

N

Syslog

%PORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBUFSIZE

Y

N

Syslog

%PORT-3-IF_UNSUPPORTED_TRANSCEIVER

Y

N

Syslog

%PORT-5-IF_DOWN_ETH_IF_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_FICON_NOT_ENABLED

Y

N

Syslog

%PORT-5-MODULE_INDEX_RESTORE_ERROR

Y

N

Syslog

%PORT-5-MODULE_UNLIMITED_OSM_SEQ_FAILED

Y

N

Syslog

%PORT-5-IF_DOWN_NON_PARTICIPATING

Y

N

Syslog

%PORT-5-IF_DOWN_ADMIN_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_CLASSF_PARAM_ERR

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_PARAM

Y

N

Syslog

%PORT-5-IF_DOWN_SRC_PORT_NOT_BOUND

Y

N

Syslog

%PORT-5-IF_DOWN_INTERFACE_REMOVED

Y

N

Syslog

%PORT-5-IF_DOWN_FCOT_VENDOR_NOT_SUPPORTED

Y

N

Syslog

%PORT-5-IF_DOWN_EPP_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_CFG_CHANGE

Y

N

Syslog

%PORT-5-IF_DOWN_SRC_MOD_NOT_ONLINE

Y

N

Syslog

%PORT-5-IF_DOWN_FCSP_AUTHENT_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_FICON_BEING_ENABLED

Y

N

Syslog

%PORT-5-IF_DOWN_VIRTUAL_IVR_DOMAIN_OVERLAP_ISOLATION

Y

N

Syslog

^[LICENSE_VIOLATION]*No license installed for feature

Y

N

Syslog

^[LICENSE_VIOLATION]*License has expired for feature

Y

N

Syslog

^[LICENSE_VIOLATION]*License file is missing for feature

Y

N

Syslog

%PORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE

Y

N

Syslog

%PORT-5-IF_DOWN_SUSPENDED

Y

N

Syslog

%PORT-5-IF_DOWN_ESC_FAILURE_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_PARENT_ADMIN_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_SUSPENDED_BY_SPEED

Y

N

Syslog

%PORT-5-IF_DOWN_SUSPENDED_BY_WWN

Y

N

Syslog

%PORT-5-IF_DOWN_MODULE_REMOVED

Y

N

Syslog

%PORT-5-IF_TRUNK_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_TCP_KEEP_ALIVE_EXPIRED

Y

N

Syslog

%PORT-5-IF_DOWN_SRC_PORT_REMOVED

Y

N

Syslog

%PORT-5-IF_DOWN_INVALID_CONFIG

Y

N

Syslog

%PORT-5-IF_DOWN_NO_TRUNK_OPER_VSANS_ISOLATION

Y

N

Syslog

%PORT-5-IF_DOWN_PORT_BLOCKED

Y

N

Syslog

%PORT-5-IF_DOWN_OLS_RCVD

Y

N

Syslog

%PORT-5-IF_BRINGUP_ALLOWED_FCOT_CHECKSUM_ERR

Y

N

Syslog

%PORT-5-IF_DOWN_LOCALLY_DISRUPTIVE_RECONFIGURATION

Y

N

Syslog

%PORT-5-IF_DOWN_INITIALIZING

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_CODE

Y

N

Syslog

%PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_PORT_NAME

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED

Y

N

Syslog

%PORT-5-IF_DOWN_DOMAIN_INVALID_RCF_RECEIVED

Y

N

Syslog

%PORT-5-IF_DOWN_FCOT_NOT_PRESENT

Y

N

Syslog

%PORT-5-IF_DOWN_PEER_CLOSE

Y

N

Syslog

%PORT-5-IF_DOWN_ETH_LINK_DOWN

Y

N

Syslog

%PORT-5-IF_DOWN_BIT_ERR_RT_THRES_EXCEEDED

Y

N

Syslog

%PORT-5-IF_DOWN_NOS_RCVD

Y

N

Syslog

%PORT-5-IF_DOWN_DPVM_VSAN_NOT_FOUND

Y

N

Syslog

%PORT-5-EC_DISABLED_AS_LICENSE_NOT_PRESENT

Y

N


Nexus 7000

Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

ManagementPortLoopback - Places the external Ethernet management port into loopback, sends a diagnostic packet to it, and verifies it is received.

Y

Y

Diagnostics

EOBCPortLoopback - Checks the internal Ethernet Out-of-Band ChaNel (EOBC) coNectivity.

Y

Y

Diagnostics

USB - Checks for the initialization of the USB controller on the supervisor card.

Y

Y

Diagnostics

CryptoDevice - Checks for the initialization of the Cavium Security chip on the Supervisor card.

Y

Y

Diagnostics

ASICRegisterCheck - Monitors the health of the application-specific integrated circuits (ASICs).

Y

Y

Diagnostics

SpineControlBus - Checks the standby control bus coNectivity from the spine card to the active Supervisor card.

Y

Y

Diagnostics

NVRAM - Periodically verifies the checksum of a small block of NVRAM.

Y

N

Diagnostics

RealTimeClock - Compares the RTC time with system clock, and verifies they are in sync.

Y

N

Diagnostics

PrimaryBootROM - Checks the integrity of the image programmed on the primary bootrom.

Y

N

Diagnostics

SecondaryBootROM - Verifies the image programmed on the secondary bootrom.

Y

N

Diagnostics

CompactFlash - Performs a read write test on the internal compact flash that stores bootup images.

Y

N

Diagnostics

ExternalCompactFlash - Performs a read write test External compact flash in slot 0.

Y

N

Diagnostics

PwrMgmtBus - Verifies the power management card and the power management Bus.

Y

N

Diagnostics

SystemMgmtBus - Checks the functionality of system management bus that coNects the supervisor to fan-tray, power supplies and system identification PROMs.

Y

N

Diagnostics

PortLoopback - Health monitoring test and at linecard bootup.

Y

N

Diagnostics

RewriteEngineLoopback - Verifies whether the forwarding device and rewrite engine on the linecards are functional.

Y

N

Diagnostics

LogFlash(ExternalCompactFlash) - LogFlash test performs a read/write test on the external LogFlash on the supervisor module slot1.

Y

N

Diagnostics

CMP_FAILURE - The device has a CMP failure with message <message from message description>.

Y

Y

Diagnostics

SUP_FAILURE - Standby supervisor failed and needs to be rebooted.

Y

Y

Diagnostics

LINECARD_FAILURE - Line card is not recognized by the device or the device is unable to bring up the line card.

Y

Y

Diagnostics

PORT_FAILURE - A Hardware failure has occurred on the interface <port string> and the port is down.

Y

N

Diagnostics

SW_CRASH - A service has terminated its execution abnormally and a syslog message is recorded.

Y

N

Diagnostics

SW_SYSTEM_INCONSISTENT

Y

N


Environment

Alarm Type
Alarm Message Information
Notify
Create Service Request
Environment

TEMPERATURE_ALARM - This is a temperature faultalarm message for module x.

Y

N

Environment

TEMPERATURE_ALARM - This is a Minor temperature alarm message for module x.

Y

N

Environment

TEMPERATURE_ALARM - This is a Major temperature alarm message for module x.

Y

N

Environment

FAN_FAILURE - Fan Tray FAN_TRAY_NUM is reporting an alarm.

Y

Y

Environment

POWER_SUPPLY_FAILURE - There is insufficient power to operate all FRUs in the system.

Y

Y

Environment

POWER_SUPPLY_SHUTDOWN - Power Supply POWER_MOD has reported a power supply shutdown alarm.

Y

N

Environment

POWER_SUPPLY_FAILURE - Fan failure in power supply.

Y

Y

Environment

POWER_SUPPLY_ALERT- Detected an unsupported power supply.

Y

N


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslogs
No_license_Installed
Y
N
Syslogs

License_will_expire

Y

N

Syslogs

License_expired

Y

N

Syslogs

License_file_missing

Y

N


Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

ManagementPortLoopback - Places the external Ethernet management port into loopback, sends a diagnostic packet to it, and verifies it is received.

Y

Y

Diagnostics

EOBCPortLoopback - Checks the internal Ethernet Out-of-Band ChaNel (EOBC) coNectivity.

Y

Y

Diagnostics

USB - Checks for the initialization of the USB controller on the supervisor card.

Y

Y

Diagnostics

CryptoDevice - Checks for the initialization of the Cavium Security chip on the Supervisor card.

Y

Y

Diagnostics

ASICRegisterCheck - Monitors the health of the application-specific integrated circuits (ASICs).

Y

Y

Diagnostics

SpineControlBus - Checks the standby control bus coNectivity from the spine card to the active Supervisor card.

Y

Y

Diagnostics

NVRAM - Periodically verifies the checksum of a small block of NVRAM.

Y

N

Diagnostics

RealTimeClock - Compares the RTC time with system clock, and verifies they are in sync.

Y

N

Diagnostics

PrimaryBootROM - Checks the integrity of the image programmed on the primary bootrom.

Y

N

Diagnostics

SecondaryBootROM - Verifies the image programmed on the secondary bootrom.

Y

N

Diagnostics

CompactFlash - Performs a read write test on the internal compact flash that stores bootup images.

Y

N

Diagnostics

ExternalCompactFlash - Performs a read write test External compact flash in slot 0.

Y

N

Diagnostics

PwrMgmtBus - Verifies the power management card and the power management Bus.

Y

N

Diagnostics

SystemMgmtBus - Checks the functionality of system management bus that coNects the supervisor to fan-tray, power supplies and system identification PROMs.

Y

N

Diagnostics

PortLoopback - Health monitoring test and at linecard bootup.

Y

N

Diagnostics

RewriteEngineLoopback - Verifies whether the forwarding device and rewrite engine on the linecards are functional.

Y

N

Diagnostics

LogFlash(ExternalCompactFlash) - LogFlash test performs a read/write test on the external LogFlash on the supervisor module slot1.

Y

N

Diagnostics

CMP_FAILURE - The device has a CMP failure with message <message from message description>.

Y

Y

Diagnostics

SUP_FAILURE - Standby supervisor failed and needs to be rebooted.

Y

Y

Diagnostics

LINECARD_FAILURE - Line card is not recognized by the device or the device is unable to bring up the line card.

Y

Y

Diagnostics

PORT_FAILURE - A Hardware failure has occurred on the interface <port string> and the port is down.

Y

N

Diagnostics

SW_CRASH - A service has terminated its execution abnormally and a syslog message is recorded.

Y

N

Diagnostics

SW_SYSTEM_INCONSISTENT

Y

N


Environment

Alarm Type
Alarm Message Information
Notify
Create Service Request
Environment

TEMPERATURE_ALARM - This is a temperature faultalarm message for module x.

Y

N

Environment

TEMPERATURE_ALARM - This is a Minor temperature alarm message for module x.

Y

N

Environment

TEMPERATURE_ALARM - This is a Major temperature alarm message for module x.

Y

N

Environment

FAN_FAILURE - Fan Tray FAN_TRAY_NUM is reporting an alarm.

Y

Y

Environment

POWER_SUPPLY_FAILURE - There is insufficient power to operate all FRUs in the system.

Y

Y

Environment

POWER_SUPPLY_SHUTDOWN - Power Supply POWER_MOD has reported a power supply shutdown alarm.

Y

N

Environment

POWER_SUPPLY_FAILURE - Fan failure in power supply.

Y

Y

Environment

POWER_SUPPLY_ALERT- Detected an unsupported power supply.

Y

N


Syslogs

Alarm Type
Alarm Message Information
Notify
Create Service Request
Syslogs
No_license_Installed
Y
N
Syslogs

License_will_expire

Y

N

Syslogs

License_expired

Y

N

Syslogs

License_file_missing

Y

N


Nexus 5000 and FEX

N5K Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
N5K Diagnostics

TestFabricPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestForwardingEngine - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestForwardingEnginePort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestFrontPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestInbandPort - Since switch CPU can no longer run the appropriate control plane protocols, switch can no longer function.

Y

Y

N5K Diagnostics

TestFabricEngine - Fabric ASIC has reported major failure.

Y

Y

N5K Diagnostics

TestSPROM - Software determines module type based on information stored in Module SPROM.

Y

Y

N5K Diagnostics

TestOBFL - This failure can occur on module 1 only. OBFL is Onboard Fault Logging.

Y

Y

N5K Diagnostics

TestLED - LED control is done via the same transport mechanism to control other key components on a module.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
N5K Environment
TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm.
Y
N
N5K Environment

TestPowerSuppy

N

N

N5K Environment

TestTemperatureSensor

N

N

N5K Environment

TEMPERATURE_ALARM --- Sensor.

Y

Y

N5K Environment

PowerSupplyFailure

Y

Y

N5K Environment

Multiple fans missing or failed.

Y

N

N5K Environment

One fan missing or failed.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
N5K Syslog
No license installed for feature, is on grace license, will expire in D H.
Y
N
N5K Syslog

License for feature, will expire in H M.

Y

N

N5K Syslog

License has expired for feature.

Y

N

N5K Syslog

License file is missing for feature.

Y

N

Syslog

%KERN-2-SYSTEM_MSG

Y

N

Syslog

%SYSMGR-2-VOLATILE_DB_FULL

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
Fex Diagnostics
Forwarding ASIC port failure - The Port(s) on the forwarding engine ASICs have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.
Y
Y
Fex Diagnostics

Forwarding ASIC failure - The forwarding engine ASICs have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y

Fex Diagnostics

OBFL Flash failure - This test verifies the integrity of the On Board Failure Logging flash (OBFL).

Y

N

Fex Diagnostics

GPIO Access failure - Tests the general purpose I/O (GPIO) components.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
Fex Environment

Temperature Alarm - Temp has exceeded threshold value.

Y

N

Fex Environment

PowerSupplyFailure - The device is currently working with only one Power Supply unit.

Y

N

Fex Environment

PowerSupplyOIR - Indicates a change in power supply status.

Y

N

Fex Environment

TEMPERATURE_ALARM --- Sensor - An access failure to Temperature Sensor is recorded on the device.

Y

N

Fex Environment

Fan failure.

Y

N

Fex Environment

Fan tray missing.

Y

N

Fex Environment

Module shutdown due to FAN failure.

Y

N

Fex Environment

Module shutdown due to over-temperature condition.

Y

N


N5K Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
N5K Diagnostics

TestFabricPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestForwardingEngine - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestForwardingEnginePort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestFrontPort - The Port(s) have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y (if ports fail > 25%)

N5K Diagnostics

TestInbandPort - Since switch CPU can no longer run the appropriate control plane protocols, switch can no longer function.

Y

Y

N5K Diagnostics

TestFabricEngine - Fabric ASIC has reported major failure.

Y

Y

N5K Diagnostics

TestSPROM - Software determines module type based on information stored in Module SPROM.

Y

Y

N5K Diagnostics

TestOBFL - This failure can occur on module 1 only. OBFL is Onboard Fault Logging.

Y

Y

N5K Diagnostics

TestLED - LED control is done via the same transport mechanism to control other key components on a module.

Y

N


N5K Environment

Alarm Type
Alarm message information
Notify
Create Service Request
N5K Environment
TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm.
Y
N
N5K Environment

TestPowerSuppy

N

N

N5K Environment

TestTemperatureSensor

N

N

N5K Environment

TEMPERATURE_ALARM --- Sensor.

Y

Y

N5K Environment

PowerSupplyFailure

Y

Y

N5K Environment

Multiple fans missing or failed.

Y

N

N5K Environment

One fan missing or failed.

Y

N


N5K Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
N5K Syslog
No license installed for feature, is on grace license, will expire in D H.
Y
N
N5K Syslog

License for feature, will expire in H M.

Y

N

N5K Syslog

License has expired for feature.

Y

N

N5K Syslog

License file is missing for feature.

Y

N

Syslog

%KERN-2-SYSTEM_MSG

Y

N

Syslog

%SYSMGR-2-VOLATILE_DB_FULL

Y

N


FEX Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Fex Diagnostics
Forwarding ASIC port failure - The Port(s) on the forwarding engine ASICs have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.
Y
Y
Fex Diagnostics

Forwarding ASIC failure - The forwarding engine ASICs have failed this diagnostic test either during Power-On-Self-Test or during the Run Time monitoring.

Y

Y

Fex Diagnostics

OBFL Flash failure - This test verifies the integrity of the On Board Failure Logging flash (OBFL).

Y

N

Fex Diagnostics

GPIO Access failure - Tests the general purpose I/O (GPIO) components.

Y

N


FEX Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Fex Environment

Temperature Alarm - Temp has exceeded threshold value.

Y

N

Fex Environment

PowerSupplyFailure - The device is currently working with only one Power Supply unit.

Y

N

Fex Environment

PowerSupplyOIR - Indicates a change in power supply status.

Y

N

Fex Environment

TEMPERATURE_ALARM --- Sensor - An access failure to Temperature Sensor is recorded on the device.

Y

N

Fex Environment

Fan failure.

Y

N

Fex Environment

Fan tray missing.

Y

N

Fex Environment

Module shutdown due to FAN failure.

Y

N

Fex Environment

Module shutdown due to over-temperature condition.

Y

N


Nexus 4000

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

TestFrontPort & TestForwardingPort - The Port(s) have failed this diagnostic test during the Run Time monitoring.

Y

Y if ports failed >25%

Diagnostics

FREEDISK_FAILURE - Indicates that the " /tmp" directory can be full or near full.

Y

N

Diagnostics

NVRAM_FAILURE - Non-Volatile memory corrupted or failed on switch module <x>.

Y

N

Diagnostics

MGMT_PORT_FAILURE - Management Ethernet Port communications failed for the active supervisor module.

Y

N

Diagnostics

BOOTFLASH_FAILURE - On the switch module, the boot flash stores various vital information required for the operation of the switch.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature Alarm.

Y

N

Environment

Outstanding Alarms support: The device has recorded a <component> status of '<failure_status_from show environment>'.

Y

N

Environment

Recovery Alarms support: This message indicates that the device has recovered from a previous environmental alarm condition.

Y

N


Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

No license installed for feature, is on grace license, will expire in D H- The evaluation license installed for the <feature> is ruNing under grace period.

Y

N

Syslogs

License for feature, will expire in H M - The evaluation license installed for the <package> will expire in <show_license_usage:comments> and will be disabled soon.

Y

N

Syslogs

License has expired for feature.

Y

N

Syslogs

License file is missing for feature.

Y

N


Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

TestFrontPort & TestForwardingPort - The Port(s) have failed this diagnostic test during the Run Time monitoring.

Y

Y if ports failed >25%

Diagnostics

FREEDISK_FAILURE - Indicates that the " /tmp" directory can be full or near full.

Y

N

Diagnostics

NVRAM_FAILURE - Non-Volatile memory corrupted or failed on switch module <x>.

Y

N

Diagnostics

MGMT_PORT_FAILURE - Management Ethernet Port communications failed for the active supervisor module.

Y

N

Diagnostics

BOOTFLASH_FAILURE - On the switch module, the boot flash stores various vital information required for the operation of the switch.

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

No license installed for feature, is on grace license, will expire in D H- The evaluation license installed for the <feature> is ruNing under grace period.

Y

N

Syslogs

License for feature, will expire in H M - The evaluation license installed for the <package> will expire in <show_license_usage:comments> and will be disabled soon.

Y

N

Syslogs

License has expired for feature.

Y

N

Syslogs

License file is missing for feature.

Y

N


Environment

Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature Alarm.

Y

N

Environment

Outstanding Alarms support: The device has recorded a <component> status of '<failure_status_from show environment>'.

Y

N

Environment

Recovery Alarms support: This message indicates that the device has recovered from a previous environmental alarm condition.

Y

N


Nexus 3000

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

TestForwardingEngine

Y

Y

Diagnostics

TestForwardingPort

Y

Y

Diagnostics

TestInbandPort

Y

Y

Diagnostics

TestSPROM

Y

Y

Diagnostics

TestOBFL

Y

Y

Diagnostics

TestLED

Y

N

Diagnostics

TestPowerSupply

Y

N

Diagnostics

TestTemperatureSensor

Y

N

Diagnostics

TestVoltage

Y

N

Diagnostics

TestFan

Y

N

Diagnostics

TestMemory

Y

Y

Diagnostics

TestNVRAM

Y

Y

Diagnostics

TestManagementPort

Y

Y


Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature Alarm

Y

N

Environment

PowerSupplyFailure

Y

N

Environment

TEMPERATURE_ALARM --- Sensor

Y

Y

Environment

TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm

Y

N

Environment

Multiple fans missing or failed

Y

N

Environment

One fan missing or failed

Y

N

Environment

Voltage failure on power supply

Y

N

Environment

Temperature Alarm

Y

N

Environment

PowerSupplyFailure

Y

N

Environment

TEMPERATURE_ALARM --- Sensor

Y

Y

Environment

TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm

Y

N

Environment

Multiple fans missing or failed

Y

N

Environment

One fan missing or failed

Y

N

Environment

Voltage failure on power supply

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

No license installed for feature, is on grace license, will expire in D H

Y

N

Syslogs

License for feature, will expire in

Y

N

Syslogs

License has expired for feature

Y

N

Syslogs

License file is missing for feature

Y

N


Diagnostics

Alarm Type
Alarm message information
Notify
Create Service Request
Diagnostics

TestForwardingEngine

Y

Y

Diagnostics

TestForwardingPort

Y

Y

Diagnostics

TestInbandPort

Y

Y

Diagnostics

TestSPROM

Y

Y

Diagnostics

TestOBFL

Y

Y

Diagnostics

TestLED

Y

N

Diagnostics

TestPowerSupply

Y

N

Diagnostics

TestTemperatureSensor

Y

N

Diagnostics

TestVoltage

Y

N

Diagnostics

TestFan

Y

N

Diagnostics

TestMemory

Y

Y

Diagnostics

TestNVRAM

Y

Y

Diagnostics

TestManagementPort

Y

Y


Alarm Type
Alarm message information
Notify
Create Service Request
Environment

Temperature Alarm

Y

N

Environment

PowerSupplyFailure

Y

N

Environment

TEMPERATURE_ALARM --- Sensor

Y

Y

Environment

TestFAN -- fan speed <speed> out of range >= expected. <speed> rpm

Y

N

Environment

Multiple fans missing or failed

Y

N

Environment

One fan missing or failed

Y

N

Environment

Voltage failure on power supply

Y

N


Environment

Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

No license installed for feature, is on grace license, will expire in D H

Y

N

Syslogs

License for feature, will expire in

Y

N

Syslogs

License has expired for feature

Y

N

Syslogs

License file is missing for feature

Y

N


UBR

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

%CLCJIB-0-SDRAMUECCERR

Y

Y

Syslogs

%MCU_MEM_DDR-0-MS_ERR

Y

N

Syslogs

%MCU_PLATFORM-0-IO_TIMEOUT

Y

N

Syslogs

%UBR7100-0-CPUCARD

Y

Y

Syslogs

%UBR7200-0-LOWPOWERCPU

Y

N

Syslogs

%UBR7200-0-TEMPHIGH

Y

N

Syslogs

%UBR7100-0-TEST_CABLE

Y

N

Syslogs

%UBR7200-0-TEST_CABLE

Y

N

Syslogs

%ETSEC-1-BAD_IDB

Y

N

Syslogs

%ETSEC-1-INITFAIL_NOMEM

Y

N

Syslogs

%MCU_MEM_ECC-1-BADADDR_MBE

Y

Y

Syslogs

%MCUFSM-1-CARD_LOADING

Y

N

Syslogs

%UBR10000-1-BADCLK

Y

N

Syslogs

%UBR7200IPC-1-DISCOVER_SAR

Y

N

Syslogs

%C10KJACKET-1-PARSEINITFAIL

Y

N

Syslogs

%UBR10K-1-INVALID_DIVHDR

Y

N

Syslogs

%UBR10K-1-POWCYCLE

Y

N

Syslogs

%UBR10K-1-SNMP_GETINDEX_FAIL

Y

N

Syslogs

%UBR10K-1-UNKVECT

Y

N

Syslogs

%UBR10KTCC-1-LCLOSC

Y

N

Syslogs

%UBR10KTCC-1-NOTCC

Y

Y

Syslogs

%MCU_MEM_ECC-2-BADADDR_SBE

Y

N

Syslogs

%UBR7200IPC-2-CARDRECUR

Y

N

Syslogs

%UBR7200IPC-2-CARDTYPEERROR

Y

N

Syslogs

%UBR10KTCC-2-ACTIVE_TCC

Y

N

Syslogs

%UBR7100-0-TEMPHIGH

Y

N

Syslogs

%UBR7200-0-VOLTLOW

Y

N

Syslogs

%UBR10K-0-CLI_CMD

Y

N

Syslogs

%UBR10K-0-SNMP_SET_IPC

Y

N

Syslogs

%ETSEC-1-BAD_INTERFACE

Y

N

Syslogs

%ETSEC-1-BAD_PARTICLE

Y

N

Syslogs

%UBR7100-1-DISCOVER

Y

N

Syslogs

%UBR7200IPC-1-DISCOVER_ENET

Y

N

Syslogs

%UBR7200IPC-1-SNMP_GETINDEX_FAIL

Y

N

Syslogs

%UBR7200IPC-1-UNKEVT:

Y

N

Syslogs

%UBR10K-1-SNMP_SENDINFO_FAIL

Y

N

Syslogs

%UBR10KTCC-1-BADTCC

Y

N

Syslogs

%UBR10KTCC-1-SWTCHERR

Y

N

Syslogs

%ETSEC-2-EXCEPTION

Y

N

Syslogs

%IPCOIR-2-PLUGIN_PREANALYZE_FAIL

Y

N

Syslogs

%MCU_MEM_ECC-2-MBE

Y

N

Syslogs

%UBR7200IPC-2-CLI_UNSUPPORTED_CMD

N

N

Syslogs

%UBRLCCOREDUMP-2-EOM

Y

N

Syslogs

%UBR7200-0-CPUCARD

Y

Y

Syslogs

%UBR7200-0-STACK_PROT_UNSUPPORTED

N

N

Syslogs

%UBR1000-0-STACK_PROT_UNSUPPORTED

N

N

Syslogs

%UBR10000-0-TEMPHIGH

Y

N

Syslogs

%UBR7200-0-VOLTHIGH

Y

N

Syslogs

%ETSEC-1-INCOMPLETE_INIT

Y

N

Syslogs

%UBR10K-1-INITFAIL

Y

N

Syslogs

%UBR10K-1-IPCFAIL

Y

N

Syslogs

%UBR10KTCC-1-BADCLK

Y

N

Syslogs

%MCE_HQF_NP_CLIENT-2-FATAL

Y

N

Syslogs

%MLSCEF-2-FIB_TCAM_WRITE_INCONSISTENCY

Y

Y

Syslogs

%UBR10K-2-CLI_UNSUPPORTED_CMD

Y

N

Syslogs

%UBR10KTCC-2-LOS

Y

N

Syslogs

%CLCJIB-0-SSRAMUECCERR

Y

Y

Syslogs

%UBR10000-0-TEST_CABLE

Y

N

Syslogs

%UBR10000-0-VOLTHIGH

Y

N

Syslogs

%UBR7200IPC-0-CLI_CONFIG

Y

N

Syslogs

%ETSEC-1-BAD_PAK_ALLOCATION

Y

N

Syslogs

%ETSEC-1-PAK_TOO_BIG

Y

N

Syslogs

%MCU-1-CONFIGNOTETHER

Y

N

Syslogs

%MCU-1-DISCOVER

Y

N

Syslogs

%UBR7200-1-DISCOVER

Y

N

Syslogs

%UBR10000-1-DISCOVER

Y

N

Syslogs

%UBR7100-0-VOLTLOW

Y

N

Syslogs

%UBRSNMP-0-SNMP_SET_IPC

Y

N

Syslogs

%UBR10K-0-CLI_CONFIG

Y

N

Syslogs

%ETSEC-1-BAD_POOL

Y

N

Syslogs

%ETSEC-1-BAD_STRUCT

Y

N

Syslogs

%MCU_MEM_DDR-1-AC_ERR

Y

Y

Syslogs

%UBR10K-1-INVALIDPRIMSID

Y

N

Syslogs

%UBR10K-1-UNKEVT

Y

N

Syslogs

%UBR10K-1-UNKREQ

Y

N

Syslogs

%CR10KLCCOREDUMP-2-EOM

Y

N

Syslogs

%UBR10000-0-CPUCARD

Y

Y

Syslogs

%UBR7100-0-VOLTHIGH

Y

N

Syslogs

%UBR10000-0-VOLTLOW

Y

N

Syslogs

%ETSEC-1-BAD_INIT_PARSER

Y

N

Syslogs

%UBR10000-1-BADTCC

Y

N

Syslogs

%UBR10K-1-INVALIDSID

Y

N

Syslogs

%UBR10K-1-SNMP_SENDCMD_FAIL

Y

N

Syslogs

%UBR10KTCC-1-BLKCMD

Y

N

Syslogs

%ETSEC-1-ERROR_INT_CAUSE

Y

N

Syslogs

%UBR10KTCC-1-SWTCHERR

Y

N

Syslogs

%UBR7200IPC-2-BADRSRCNUM

Y

N

Syslogs

%UBR10000-3-SPIERRR

Y

N

Syslogs

%UBR10K-0-CLI_CONFIG

Y

N

Syslogs

%UBR7200IPC-1-UNKEVT

Y

N

Syslogs

%IPCOIR-2-CARD_UP_DOWN

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslogs

%CLCJIB-0-SDRAMUECCERR

Y

Y

Syslogs

%MCU_MEM_DDR-0-MS_ERR

Y

N

Syslogs

%MCU_PLATFORM-0-IO_TIMEOUT

Y

N

Syslogs

%UBR7100-0-CPUCARD

Y

Y

Syslogs

%UBR7200-0-LOWPOWERCPU

Y

N

Syslogs

%UBR7200-0-TEMPHIGH

Y

N

Syslogs

%UBR7100-0-TEST_CABLE

Y

N

Syslogs

%UBR7200-0-TEST_CABLE

Y

N

Syslogs

%ETSEC-1-BAD_IDB

Y

N

Syslogs

%ETSEC-1-INITFAIL_NOMEM

Y

N

Syslogs

%MCU_MEM_ECC-1-BADADDR_MBE

Y

Y

Syslogs

%MCUFSM-1-CARD_LOADING

Y

N

Syslogs

%UBR10000-1-BADCLK

Y

N

Syslogs

%UBR7200IPC-1-DISCOVER_SAR

Y

N

Syslogs

%C10KJACKET-1-PARSEINITFAIL

Y

N

Syslogs

%UBR10K-1-INVALID_DIVHDR

Y

N

Syslogs

%UBR10K-1-POWCYCLE

Y

N

Syslogs

%UBR10K-1-SNMP_GETINDEX_FAIL

Y

N

Syslogs

%UBR10K-1-UNKVECT

Y

N

Syslogs

%UBR10KTCC-1-LCLOSC

Y

N

Syslogs

%UBR10KTCC-1-NOTCC

Y

Y

Syslogs

%MCU_MEM_ECC-2-BADADDR_SBE

Y

N

Syslogs

%UBR7200IPC-2-CARDRECUR

Y

N

Syslogs

%UBR7200IPC-2-CARDTYPEERROR

Y

N

Syslogs

%UBR10KTCC-2-ACTIVE_TCC

Y

N

Syslogs

%UBR7100-0-TEMPHIGH

Y

N

Syslogs

%UBR7200-0-VOLTLOW

Y

N

Syslogs

%UBR10K-0-CLI_CMD

Y

N

Syslogs

%UBR10K-0-SNMP_SET_IPC

Y

N

Syslogs

%ETSEC-1-BAD_INTERFACE

Y

N

Syslogs

%ETSEC-1-BAD_PARTICLE

Y

N

Syslogs

%UBR7100-1-DISCOVER

Y

N

Syslogs

%UBR7200IPC-1-DISCOVER_ENET

Y

N

Syslogs

%UBR7200IPC-1-SNMP_GETINDEX_FAIL

Y

N

Syslogs

%UBR7200IPC-1-UNKEVT:

Y

N

Syslogs

%UBR10K-1-SNMP_SENDINFO_FAIL

Y

N

Syslogs

%UBR10KTCC-1-BADTCC

Y

N

Syslogs

%UBR10KTCC-1-SWTCHERR

Y

N

Syslogs

%ETSEC-2-EXCEPTION

Y

N

Syslogs

%IPCOIR-2-PLUGIN_PREANALYZE_FAIL

Y

N

Syslogs

%MCU_MEM_ECC-2-MBE

Y

N

Syslogs

%UBR7200IPC-2-CLI_UNSUPPORTED_CMD

N

N

Syslogs

%UBRLCCOREDUMP-2-EOM

Y

N

Syslogs

%UBR7200-0-CPUCARD

Y

Y

Syslogs

%UBR7200-0-STACK_PROT_UNSUPPORTED

N

N

Syslogs

%UBR1000-0-STACK_PROT_UNSUPPORTED

N

N

Syslogs

%UBR10000-0-TEMPHIGH

Y

N

Syslogs

%UBR7200-0-VOLTHIGH

Y

N

Syslogs

%ETSEC-1-INCOMPLETE_INIT

Y

N

Syslogs

%UBR10K-1-INITFAIL

Y

N

Syslogs

%UBR10K-1-IPCFAIL

Y

N

Syslogs

%UBR10KTCC-1-BADCLK

Y

N

Syslogs

%MCE_HQF_NP_CLIENT-2-FATAL

Y

N

Syslogs

%MLSCEF-2-FIB_TCAM_WRITE_INCONSISTENCY

Y

Y

Syslogs

%UBR10K-2-CLI_UNSUPPORTED_CMD

Y

N

Syslogs

%UBR10KTCC-2-LOS

Y

N

Syslogs

%CLCJIB-0-SSRAMUECCERR

Y

Y

Syslogs

%UBR10000-0-TEST_CABLE

Y

N

Syslogs

%UBR10000-0-VOLTHIGH

Y

N

Syslogs

%UBR7200IPC-0-CLI_CONFIG

Y

N

Syslogs

%ETSEC-1-BAD_PAK_ALLOCATION

Y

N

Syslogs

%ETSEC-1-PAK_TOO_BIG

Y

N

Syslogs

%MCU-1-CONFIGNOTETHER

Y

N

Syslogs

%MCU-1-DISCOVER

Y

N

Syslogs

%UBR7200-1-DISCOVER

Y

N

Syslogs

%UBR10000-1-DISCOVER

Y

N

Syslogs

%UBR7100-0-VOLTLOW

Y

N

Syslogs

%UBRSNMP-0-SNMP_SET_IPC

Y

N

Syslogs

%UBR10K-0-CLI_CONFIG

Y

N

Syslogs

%ETSEC-1-BAD_POOL

Y

N

Syslogs

%ETSEC-1-BAD_STRUCT

Y

N

Syslogs

%MCU_MEM_DDR-1-AC_ERR

Y

Y

Syslogs

%UBR10K-1-INVALIDPRIMSID

Y

N

Syslogs

%UBR10K-1-UNKEVT

Y

N

Syslogs

%UBR10K-1-UNKREQ

Y

N

Syslogs

%CR10KLCCOREDUMP-2-EOM

Y

N

Syslogs

%UBR10000-0-CPUCARD

Y

Y

Syslogs

%UBR7100-0-VOLTHIGH

Y

N

Syslogs

%UBR10000-0-VOLTLOW

Y

N

Syslogs

%ETSEC-1-BAD_INIT_PARSER

Y

N

Syslogs

%UBR10000-1-BADTCC

Y

N

Syslogs

%UBR10K-1-INVALIDSID

Y

N

Syslogs

%UBR10K-1-SNMP_SENDCMD_FAIL

Y

N

Syslogs

%UBR10KTCC-1-BLKCMD

Y

N

Syslogs

%ETSEC-1-ERROR_INT_CAUSE

Y

N

Syslogs

%UBR10KTCC-1-SWTCHERR

Y

N

Syslogs

%UBR7200IPC-2-BADRSRCNUM

Y

N

Syslogs

%UBR10000-3-SPIERRR

Y

N

Syslogs

%UBR10K-0-CLI_CONFIG

Y

N

Syslogs

%UBR7200IPC-1-UNKEVT

Y

N

Syslogs

%IPCOIR-2-CARD_UP_DOWN

Y

N


Generic Syslogs

Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog

%SCCP-0-PANIC

Y

Y

Syslog

%TURBORSC-0-BUS_ERR_MULT

Y

N

Syslog

%TURBORSC-0-BUS_ERR_ILL_ADDR

Y

N

Syslog

%NP_VPD-0-NO_MODULE_ELEMENTS

Y

N

Syslog

%NP_VPD-0-NO_SUCH_SLOT

Y

N

Syslog

%MGBL-SYS-2-MALLOCFAIL

Y

Y

Syslog

%CDP_PD-2-POWER_LOWLOW_POWER_CLASSIC_NO_INJECTOR_CONFIGURED

Y

Y

Syslog

%CDP_PD-2-POWER_LOWLOW_POWER_CLASSIC_INJECTOR_CONFIGURED_ON_ANOTHER_PORT

Y

Y

Syslog

%CRYPTO-3-IKE_PAK_IN_Q_TIME_LIMIT_EXCEED

Y

N

Syslog

%ESF_IPC-2-SEND_MSG_TIMEOUT

Y

Y

Syslog

%PLATFORM-0-ARP ARP error:

Y

N

Syslog

%EARL-2-SWITCH_BUS_IDLE

Y

Y

Syslog

%CDP_PD-2-POWER_LOWNEGOTIATED

Y

Y

Syslog

%IPFAST-2-FAILOPENIPCPORT

Y

Y

Syslog

%SPANTREE-2-ROOTGUARD_CONFIG_CHANGE

Y

N

Syslog

%TURBORSC-0-BUS_ERR_UNKNOWN

Y

N

Syslog

%NP_MD-0-NO_SUCH_SLOT

Y

N

Syslog

%NP_MD-0-NOTTYS

Y

N

Syslog

%LICENSE-1-TRANSITION_COMPLETE

N

N

Syslog

%ASA-1-735004

Y

Y

Syslog

%PLATFORM-0-SAMI_INVALID_SLOT_ID

Y

N

Syslog

%TURBORSC-0-BUS_ERR_BLK

Y

N

Syslog

%TURBORSC-0-BUS_ERR_PARITY

Y

N

Syslog

%NP_MD-0-SLOT_ALREADY_PRESENT

Y

N

Syslog

%PLATFORM_ENV-1-FRU_PS_ACCESS

Y

N

Syslog

%SYS-2-MALLOCFAIL

Y

N

Syslog

%WCCP-1-SERVICELOST

Y

N

Syslog

%SPANTREE_VLAN_SW-2-MAX_INSTANCE

Y

N

Syslog

%CDP_PD-2-POWER_LOWHIGH_POWER_CLASSIC_NOT_ CONFIGURED

Y

N

Syslog

%PACC_IPC-0-IPC_MASTER

Y

N

Syslog

%NP_VPD-0-NO_SUCH_VOICE_PORT

Y

N

Syslog

%SYS-2-GETBUF

Y

Y

Syslog

%GENERIC_SUBBLOCK-2-UNPACKXDR

Y

Y

Syslog

%SYS-3-CPUHOG

Y

N

Syslog

%LTL2-LTL_PARITY_CHECK

Y

N

Syslog

%EOS-2-INT

Y

Y

Syslog

%PM_SCP-1-LCP_FW_ERR

Y

Y

Syslog

%SYS-2-BLOCKHUNG

Y

N

Syslog

%PFINIT-2-NOMEM

N

N

Syslog

%SYS-2-INTSCHED

Y

N

Syslog

%SLICE_TOASTER-0-FP_ERROR

Y

Y

Syslog

%SLICE_TOASTER-0-FP_REV

Y

Y

Syslog

%SLICE_TOASTER-0-FP_TYPE

Y

Y

Syslog

%TDM_CONN-0-MALLOC_FAIL

Y

Y

Syslog

%NP_VPD-0-NOHWIDBS Cannont create hwidb for slotdec]

Y

N

Syslog

%NP_VPD-0-NOHWIDBSCannot allocate interface Async\[dec]/\[dec]

Y

N

Syslog

%NP_VPD-0-NO_SUCH_LINE

Y

N

Syslog

%NP_VPD-0-SLOT_ALREADY_PRESENT

Y

N

Syslog

%SYS2-BADSHARE

Y

N

Syslog

%FM-2-FLOWMASK_CONFLICT

Y

N

Syslog

%DAEMON-3-SYSTEM_MSG

Y

N

Syslog

%ILET-1-AUTHENTICATION_FAIL

Y

Y

Syslog

%LINK-3-UPDOWN

Y

N

Syslog

%LICENSE-1-TRANSITION

Y

N

Syslog

%PACC_IPC-0-DOORBELL_NOINT

Y

Y

Syslog

%PA-0-RUPTCONFLICT

Y

N

Syslog

%NP_SSM-0-NOMEMORY

Y

N

Syslog

%PACC_IPC-0-DOORBELL

Y

N

Syslog

%PLATFORM_ENV-1-FRU_PS_SIGNAL_FAULTY

Y

Y

Syslog

%RTD-1-LINK_FLAP

Y

N

Syslog

%AAA-1-AAA_SESSION_LIMIT_REJECT

Y

N

Syslog

%DATACORRUPTION-1-DATAINCONSISTENCY

Y

N

Syslog

%SYS-2-SYSMEMINFO

Y

N

Syslog

%ENVMON-2-IN_OUTLET_OVERTEMP

Y

N

Syslog

%SERIAL-0-860_BOOT_NOTOK

Y

Y

Syslog

%TURBORSC-0-BUS_ERR_TIMEOUT

Y

N

Syslog

%TURBORSC-0-UNCORRECTABLE_ECC_ERR

Y

N

Syslog

%NP_VPD-0-NOMEMORY

Y

N

Syslog

%SYS-2-NOBLOCK

Y

N

Syslog

%ENVM-2-ENVCRIT

Y

Y

Syslog

%FM-2-ACL_MERGE_NUM_ACES

Y

N

Syslog

%PLATFORM-2-PS_CAPACITY_CHANGE

Y

N

Syslog

%REDUNDANCY-3-CONFIG_SYNC

Y

N

Syslog

%SYS-2-NULLCHUNK

Y

N

Syslog
%CLAW-3-NOMEM:

Y

N

Syslog
%CLIENT_CLOCK_SYNC-3-PORTOPEN:

Y

N

Syslog
%CLIENT_CLOCK_SYNC-3-PORTREG

Y

N

Syslog
%CLNS-3-CKSUMERR:

Y

N

Syslog
%CLNS-3-IPLIST:

Y

N

Syslog
%CLNS-3-LSPIXARRMATCH:

Y

N

Syslog
%CLNS-3-LSPTOOBIG:

Y

N

Syslog
%DIAG-3-CARD_ABSENT:

Y

N

Syslog
%DHCP_SNOOPING-6-LEASE_EXPIRED:

Y

N

Syslog
%DHCP_SNOOPING-6-VLAN_NOT_SUPPORTED:

Y

N

Syslog
%CMANRP-3-MSGDISPATCH:

Y

N

Syslog
%CMCC-3-CFGCMDDROPPED:

Y

N

Syslog
%CMANCC-3-MSGDISPATCH:

Y

N

Syslog
%CMCC-3-IPCINITFAIL:

Y

N

Syslog
%CMCC-3-NODEED:

Y

N

Syslog
%CMCC-3-NOENABLE:

Y

N

Syslog
%CMCC-3-RSETFAIL:

Y

N

Syslog
%CLOCKSW-3-CLOCK_FAIL:

Y

N

Syslog
%CLOCKSW-3-CLOCK_ALL_FAIL:

Y

N

Syslog
%CLOCK-3-HW_CAL_INVALID:

Y

N

Syslog
%CLNS-3-FILTERS:

Y

N

Syslog
%CLNS-3-NSF_CID_FORCE_FAILURE:

Y

N

Syslog
%CLNS-3-NSF_CID_FORCE_FAILURE:

Y

N

Syslog
%CLNS-3-NSF_CP_ADJ_CID_MISMATCH:

Y

N

Syslog
%CLAW-3-DELNOTHERE|DELNOTME:

Y

N

Syslog
%DIAG-3-TEST_SKIPPED:

Y

N

Syslog
%DIAG-3-TEST_FAIL:

Y

N

Syslog
%DIAG-3-SUP_FAILURE:

Y

N

Syslog
%DIAG-3-SKIP_ONDEMAND_STANDBY_SUP_TEST:

Y

N

Syslog
%DIAG-3-NO_TEST:

Y

N

Syslog
%DIAG-3-NO_MEM:

Y

N

Syslog
%DIAG-3-MOD_ABSENT:

Y

N

Syslog
%DIAG-3-MINOR_HW:

Y

N

Syslog
%DIAG-3-MAJOR_HW:

Y

N

Syslog
%DIAG-3-MEMORY_CRITICAL_DOWN:

Y

N

Syslog
%DIAG-3-MEMORY_SHUT_DOWN:

Y

N

Syslog
%HA_CONFIG_SYNC-3-LBL_CFGSYNC:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-ERROR:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-MORE_COR_ERR:

Y

N

Syslog
%SYS-3-PORT_RUNTS:

Y

N

Syslog
%MWAM-0-CORRECTABLE_ECC_ERR:

Y

Y

Syslog
%HYPERION-4-HYP_RESET:

Y

Y

Syslog
%ALIGN-3-SPURIOUS:

Y

Y

Syslog
%LICMGRLOG_LIC_GRACE_EXPIRED:

Y

N

Syslog
%ALIGN-3-TRACE:

Y

N

Syslog
%EARL_L3_ASIC-3-INTR_WARN:

Y

Y

Syslog
%INTR_MGR-3-BURST:

Y

Y

Syslog
%DUAL-5-NBRCHANGE:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-COR_MEM_ERR:

Y

Y

Syslog
%IPC-5-INVALID:

Y

N

Syslog
%CLAW-0-BADHNAME:

Y

N

Syslog
%BGP-3-INVALID_MPLS:

Y

N

Syslog
%C10K-3-LC_ERR:

Y

N

Syslog
%C6KENV-4-MINORTEMPALARM:

Y

N

Syslog
%C6KENV-4-FANTRAYOK:

Y

N

Syslog
%CDP-4-DUPLEX_MISMATCH:

Y

N

Syslog
%CONTROLLER-5-UPDOWN:

Y

Y

Syslog
%CRYPTO-4-RECVD_PKT_NOT_IPSEC:

Y

N

Syslog
%CRYPTO-6-IKMP_MODE_FAILURE:

Y

N

Syslog
%EARL-4-NF_USAGE:

Y

N

Syslog
%ENT_API-4-NOPARENT:

Y

N

Syslog
%FW-4-TCP_OoO_SEG:

Y

N

Syslog
%ILPOWER-7-DETECT:

Y

N

Syslog
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL:

N

Y

Syslog
%IP-3-LOOPPAK:

Y

N

Syslog
%IP-4-DUPADDR:

Y

N

Syslog
%KERN-6-SYSTEM_MSG:

Y

N

Syslog
%L3_ASIC-4-ERR_INTRPT:

Y

Y

Syslog
%LINK-4-TOOBIG:

Y

N

Syslog
%LINK-5-CHANGED:

Y

Y

Syslog
%LWAPP-3-INVALID_AID2:

Y

Y

Syslog
%PFREDUN-4-VERSION_MISMATCH:

Y

N

Syslog
%PF_ASIC-3-ASIC_DUMP:

Y

N

Syslog
%PKI-3-SOCKETSELECT:

Y

N

Syslog
%PKI-3-SOCKETSEND:

Y

Y

Syslog
%PLATFORM_STACKPOWER-4-PRIO_CONFLICT:

Y

N

Syslog
%PLATFORM_STACKPOWER-4-UNBALANCED_PS:

Y

Y

Syslog
%PM-4-ERR_RECOVER:

Y

N

Syslog
%RFS-3-START_NEGO_SESSION:

Y

N

Syslog
%SEC_LOGIN-4-LOGIN_FAILED:

Y

N

Syslog
%SPANTREE-5-EXTENDED_SYSID:

Y

N

Syslog
%SSA-4-FABRICCRCERRS:

Y

Y

Syslog
%STACKMGR-5-MASTER_READY:

Y

Y

Syslog
%STORM_CONTROL-3-FILTERED:

Y

N

Syslog
%SWITCH_QOS_TB-5-TRUST_DEVICE_LOST:

Y

N

Syslog
%SW_DAI-4-DHCP_SNOOPING_DENY:

Y

N

Syslog
%SYS-3-CONFIG_NV_DATA:

Y

N

Syslog
%SYS-5-PRIV_AUTH_FAIL:

Y

N

Syslog
%SYS-6-EXIT_CONFIG:

Y

N

Syslog
%TAGCON-3-DUP_ADDR_RCVD:

Y

N

Syslog
%TAGCON-3-TDPID:

Y

N


Syslogs

Alarm Type
Alarm message information
Notify
Create Service Request
Syslog

%SCCP-0-PANIC

Y

Y

Syslog

%TURBORSC-0-BUS_ERR_MULT

Y

N

Syslog

%TURBORSC-0-BUS_ERR_ILL_ADDR

Y

N

Syslog

%NP_VPD-0-NO_MODULE_ELEMENTS

Y

N

Syslog

%NP_VPD-0-NO_SUCH_SLOT

Y

N

Syslog

%MGBL-SYS-2-MALLOCFAIL

Y

Y

Syslog

%CDP_PD-2-POWER_LOWLOW_POWER_CLASSIC_NO_INJECTOR_CONFIGURED

Y

Y

Syslog

%CDP_PD-2-POWER_LOWLOW_POWER_CLASSIC_INJECTOR_CONFIGURED_ON_ANOTHER_PORT

Y

Y

Syslog

%CRYPTO-3-IKE_PAK_IN_Q_TIME_LIMIT_EXCEED

Y

N

Syslog

%ESF_IPC-2-SEND_MSG_TIMEOUT

Y

Y

Syslog

%PLATFORM-0-ARP ARP error:

Y

N

Syslog

%EARL-2-SWITCH_BUS_IDLE

Y

Y

Syslog

%CDP_PD-2-POWER_LOWNEGOTIATED

Y

Y

Syslog

%IPFAST-2-FAILOPENIPCPORT

Y

Y

Syslog

%SPANTREE-2-ROOTGUARD_CONFIG_CHANGE

Y

N

Syslog

%TURBORSC-0-BUS_ERR_UNKNOWN

Y

N

Syslog

%NP_MD-0-NO_SUCH_SLOT

Y

N

Syslog

%NP_MD-0-NOTTYS

Y

N

Syslog

%LICENSE-1-TRANSITION_COMPLETE

N

N

Syslog

%ASA-1-735004

Y

Y

Syslog

%PLATFORM-0-SAMI_INVALID_SLOT_ID

Y

N

Syslog

%TURBORSC-0-BUS_ERR_BLK

Y

N

Syslog

%TURBORSC-0-BUS_ERR_PARITY

Y

N

Syslog

%NP_MD-0-SLOT_ALREADY_PRESENT

Y

N

Syslog

%PLATFORM_ENV-1-FRU_PS_ACCESS

Y

N

Syslog

%SYS-2-MALLOCFAIL

Y

N

Syslog

%WCCP-1-SERVICELOST

Y

N

Syslog

%SPANTREE_VLAN_SW-2-MAX_INSTANCE

Y

N

Syslog

%CDP_PD-2-POWER_LOWHIGH_POWER_CLASSIC_NOT_ CONFIGURED

Y

N

Syslog

%PACC_IPC-0-IPC_MASTER

Y

N

Syslog

%NP_VPD-0-NO_SUCH_VOICE_PORT

Y

N

Syslog

%SYS-2-GETBUF

Y

Y

Syslog

%GENERIC_SUBBLOCK-2-UNPACKXDR

Y

Y

Syslog

%SYS-3-CPUHOG

Y

N

Syslog

%LTL2-LTL_PARITY_CHECK

Y

N

Syslog

%EOS-2-INT

Y

Y

Syslog

%PM_SCP-1-LCP_FW_ERR

Y

Y

Syslog

%SYS-2-BLOCKHUNG

Y

N

Syslog

%PFINIT-2-NOMEM

N

N

Syslog

%SYS-2-INTSCHED

Y

N

Syslog

%SLICE_TOASTER-0-FP_ERROR

Y

Y

Syslog

%SLICE_TOASTER-0-FP_REV

Y

Y

Syslog

%SLICE_TOASTER-0-FP_TYPE

Y

Y

Syslog

%TDM_CONN-0-MALLOC_FAIL

Y

Y

Syslog

%NP_VPD-0-NOHWIDBS Cannont create hwidb for slotdec]

Y

N

Syslog

%NP_VPD-0-NOHWIDBSCannot allocate interface Async\[dec]/\[dec]

Y

N

Syslog

%NP_VPD-0-NO_SUCH_LINE

Y

N

Syslog

%NP_VPD-0-SLOT_ALREADY_PRESENT

Y

N

Syslog

%SYS2-BADSHARE

Y

N

Syslog

%FM-2-FLOWMASK_CONFLICT

Y

N

Syslog

%DAEMON-3-SYSTEM_MSG

Y

N

Syslog

%ILET-1-AUTHENTICATION_FAIL

Y

Y

Syslog

%LINK-3-UPDOWN

Y

N

Syslog

%LICENSE-1-TRANSITION

Y

N

Syslog

%PACC_IPC-0-DOORBELL_NOINT

Y

Y

Syslog

%PA-0-RUPTCONFLICT

Y

N

Syslog

%NP_SSM-0-NOMEMORY

Y

N

Syslog

%PACC_IPC-0-DOORBELL

Y

N

Syslog

%PLATFORM_ENV-1-FRU_PS_SIGNAL_FAULTY

Y

Y

Syslog

%RTD-1-LINK_FLAP

Y

N

Syslog

%AAA-1-AAA_SESSION_LIMIT_REJECT

Y

N

Syslog

%DATACORRUPTION-1-DATAINCONSISTENCY

Y

N

Syslog

%SYS-2-SYSMEMINFO

Y

N

Syslog

%ENVMON-2-IN_OUTLET_OVERTEMP

Y

N

Syslog

%SERIAL-0-860_BOOT_NOTOK

Y

Y

Syslog

%TURBORSC-0-BUS_ERR_TIMEOUT

Y

N

Syslog

%TURBORSC-0-UNCORRECTABLE_ECC_ERR

Y

N

Syslog

%NP_VPD-0-NOMEMORY

Y

N

Syslog

%SYS-2-NOBLOCK

Y

N

Syslog

%ENVM-2-ENVCRIT

Y

Y

Syslog

%FM-2-ACL_MERGE_NUM_ACES

Y

N

Syslog

%PLATFORM-2-PS_CAPACITY_CHANGE

Y

N

Syslog

%REDUNDANCY-3-CONFIG_SYNC

Y

N

Syslog

%SYS-2-NULLCHUNK

Y

N

Syslog
%CLAW-3-NOMEM:

Y

N

Syslog
%CLIENT_CLOCK_SYNC-3-PORTOPEN:

Y

N

Syslog
%CLIENT_CLOCK_SYNC-3-PORTREG

Y

N

Syslog
%CLNS-3-CKSUMERR:

Y

N

Syslog
%CLNS-3-IPLIST:

Y

N

Syslog
%CLNS-3-LSPIXARRMATCH:

Y

N

Syslog
%CLNS-3-LSPTOOBIG:

Y

N

Syslog
%DIAG-3-CARD_ABSENT:

Y

N

Syslog
%DHCP_SNOOPING-6-LEASE_EXPIRED:

Y

N

Syslog
%DHCP_SNOOPING-6-VLAN_NOT_SUPPORTED:

Y

N

Syslog
%CMANRP-3-MSGDISPATCH:

Y

N

Syslog
%CMCC-3-CFGCMDDROPPED:

Y

N

Syslog
%CMANCC-3-MSGDISPATCH:

Y

N

Syslog
%CMCC-3-IPCINITFAIL:

Y

N

Syslog
%CMCC-3-NODEED:

Y

N

Syslog
%CMCC-3-NOENABLE:

Y

N

Syslog
%CMCC-3-RSETFAIL:

Y

N

Syslog
%CLOCKSW-3-CLOCK_FAIL:

Y

N

Syslog
%CLOCKSW-3-CLOCK_ALL_FAIL:

Y

N

Syslog
%CLOCK-3-HW_CAL_INVALID:

Y

N

Syslog
%CLNS-3-FILTERS:

Y

N

Syslog
%CLNS-3-NSF_CID_FORCE_FAILURE:

Y

N

Syslog
%CLNS-3-NSF_CID_FORCE_FAILURE:

Y

N

Syslog
%CLNS-3-NSF_CP_ADJ_CID_MISMATCH:

Y

N

Syslog
%CLAW-3-DELNOTHERE|DELNOTME:

Y

N

Syslog
%DIAG-3-TEST_SKIPPED:

Y

N

Syslog
%DIAG-3-TEST_FAIL:

Y

N

Syslog
%DIAG-3-SUP_FAILURE:

Y

N

Syslog
%DIAG-3-SKIP_ONDEMAND_STANDBY_SUP_TEST:

Y

N

Syslog
%DIAG-3-NO_TEST:

Y

N

Syslog
%DIAG-3-NO_MEM:

Y

N

Syslog
%DIAG-3-MOD_ABSENT:

Y

N

Syslog
%DIAG-3-MINOR_HW:

Y

N

Syslog
%DIAG-3-MAJOR_HW:

Y

N

Syslog
%DIAG-3-MEMORY_CRITICAL_DOWN:

Y

N

Syslog
%DIAG-3-MEMORY_SHUT_DOWN:

Y

N

Syslog
%HA_CONFIG_SYNC-3-LBL_CFGSYNC:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-ERROR:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-MORE_COR_ERR:

Y

N

Syslog
%SYS-3-PORT_RUNTS:

Y

N

Syslog
%MWAM-0-CORRECTABLE_ECC_ERR:

Y

Y

Syslog
%HYPERION-4-HYP_RESET:

Y

Y

Syslog
%ALIGN-3-SPURIOUS:

Y

Y

Syslog
%LICMGRLOG_LIC_GRACE_EXPIRED:

Y

N

Syslog
%ALIGN-3-TRACE:

Y

N

Syslog
%EARL_L3_ASIC-3-INTR_WARN:

Y

Y

Syslog
%INTR_MGR-3-BURST:

Y

Y

Syslog
%DUAL-5-NBRCHANGE:

Y

N

Syslog
%SYSTEM_CONTROLLER-3-COR_MEM_ERR:

Y

Y

Syslog
%IPC-5-INVALID:

Y

N

Syslog
%CLAW-0-BADHNAME:

Y

N

Syslog
%BGP-3-INVALID_MPLS:

Y

N

Syslog
%C10K-3-LC_ERR:

Y

N

Syslog
%C6KENV-4-MINORTEMPALARM:

Y

N

Syslog
%C6KENV-4-FANTRAYOK:

Y

N

Syslog
%CDP-4-DUPLEX_MISMATCH:

Y

N

Syslog
%CONTROLLER-5-UPDOWN:

Y

Y

Syslog
%CRYPTO-4-RECVD_PKT_NOT_IPSEC:

Y

N

Syslog
%CRYPTO-6-IKMP_MODE_FAILURE:

Y

N

Syslog
%EARL-4-NF_USAGE:

Y

N

Syslog
%ENT_API-4-NOPARENT:

Y

N

Syslog
%FW-4-TCP_OoO_SEG:

Y

N

Syslog
%ILPOWER-7-DETECT:

Y

N

Syslog
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL:

N

Y

Syslog
%IP-3-LOOPPAK:

Y

N

Syslog
%IP-4-DUPADDR:

Y

N

Syslog
%KERN-6-SYSTEM_MSG:

Y

N

Syslog
%L3_ASIC-4-ERR_INTRPT:

Y

Y

Syslog
%LINK-4-TOOBIG:

Y

N

Syslog
%LINK-5-CHANGED:

Y

Y

Syslog
%LWAPP-3-INVALID_AID2:

Y

Y

Syslog
%PFREDUN-4-VERSION_MISMATCH:

Y

N

Syslog
%PF_ASIC-3-ASIC_DUMP:

Y

N

Syslog
%PKI-3-SOCKETSELECT:

Y

N

Syslog
%PKI-3-SOCKETSEND:

Y

Y

Syslog
%PLATFORM_STACKPOWER-4-PRIO_CONFLICT:

Y

N

Syslog
%PLATFORM_STACKPOWER-4-UNBALANCED_PS:

Y

Y

Syslog
%PM-4-ERR_RECOVER:

Y

N

Syslog
%RFS-3-START_NEGO_SESSION:

Y

N

Syslog
%SEC_LOGIN-4-LOGIN_FAILED:

Y

N

Syslog
%SPANTREE-5-EXTENDED_SYSID:

Y

N

Syslog
%SSA-4-FABRICCRCERRS:

Y

Y

Syslog
%STACKMGR-5-MASTER_READY:

Y

Y

Syslog
%STORM_CONTROL-3-FILTERED:

Y

N

Syslog
%SWITCH_QOS_TB-5-TRUST_DEVICE_LOST:

Y

N

Syslog
%SW_DAI-4-DHCP_SNOOPING_DENY:

Y

N

Syslog
%SYS-3-CONFIG_NV_DATA:

Y

N

Syslog
%SYS-5-PRIV_AUTH_FAIL:

Y

N

Syslog
%SYS-6-EXIT_CONFIG:

Y

N

Syslog
%TAGCON-3-DUP_ADDR_RCVD:

Y

N

Syslog
%TAGCON-3-TDPID:

Y

N