show |
Show running system information
|
environment |
system environment information
|
clock |
Chassis Clock information
|
fan |
Fan information
|
power |
Power capacity and power distribution information
|
detail |
Detail Fan-tray information when used with Fan. Detail Power capacity and power distribution information when used with Power
|
ampere |
Ampere Power capacity and power distribution information
|
temperature |
temperature sensor information
|
module |
enter a module number
|
module |
Type: integer
please enter the module number
|
s0 |
Type: xbar-str
xbar
|
santa-cruz-range |
Type: integer
please enter the xbar number
|
__readonly__ |
|
TABLE_clockinfo |
Environment Clock
|
clockname |
Type: string
Clock Instance (A or B)
|
clkmodel |
Type: string
Model number of clock
|
clkhwver |
Type: string
Hardware version of the clock
|
clkstatus |
Present/Absent Status of the clock
- None value: 0
-
- Ok value: 1
-
- Failure value: 2
-
- Absent value: 3
-
- NotSupported value: 4
-
|
act_standby |
Active/Standby Status of clock
- Active value: 0
-
- Standby value: 1
-
- None value: 2
-
|
fandetails |
Environment Fan
|
fan_filter_status |
Present/Absent Status of fan filter
- Absent value: 0
-
- Present value: 1
-
- NotSupported value: 2
-
|
TABLE_faninfo |
Fan Info
|
fanname |
Type: string
Fan Instance
|
fanmodel |
Type: string
Model number of fan
|
fanhwver |
Type: string
Hardware version of the fan
|
fandir |
Air-flow direction of the fan-tray
- back-to-front value: 1
-
- front-to-back value: 0
-
- none value: 2
-
|
fanstatus |
Present/Absent Status of the fan
- None value: 0
-
- Ok value: 1
-
- Failure value: 2
-
- Absent value: 3
-
- Shutdown value: 4
-
|
TABLE_fan_zone_speed |
Fan Zone Speeds
|
zone |
Type: string
Zone Number
|
speed |
Type: string
Zone Speed
|
failfanlet |
Type: string
failed fanlet number
|
TABLE_fantray |
Fan Tray Details table
|
fanname |
Type: string
Fan Tray Instance
|
fannum |
Type: string
Fan number in the tray
|
fandir |
Air-flow direction of the fan-tray
- back-to-front value: 1
-
- front-to-back value: 0
-
- none value: 2
-
|
fanperc |
Type: string
FAN Speed percentage
|
fanrpm |
Type: string
FAN Speed RPM
|
powersup |
Environment Power
|
voltage_level |
Type: uinteger
Voltage Level
|
TABLE_psinfo |
Power Supply Info
|
psnum |
Type: uinteger
Power Supply Number
|
psmodel |
Type: string
Power Supply Model
|
actual_out |
Type: string
Actual Output
|
actual_input |
Type: string
Actual Input
|
tot_capa |
Type: string
Total Capacity
|
ps_status |
Power Supply Status
- None value: 0
-
- Ok value: 1
-
- Fail/Shut value: 2
-
- Absent value: 3
-
- Shutdown value: 4
-
|
TABLE_mod_pow_info |
Module Power Info
|
modnum |
Type: string
Module number
|
mod_model |
Type: string
Model ProductID number
|
actual_draw |
Type: string
Actual Draw
|
allocated |
Type: string
Power allocated
|
modstatus |
Module Status
- Powered-Up value: 1
-
- Powered-Dn value: 2
-
- Pwr-Denied value: 3
-
- Err-Pwd-Dn value: 4
-
- Absent value: 5
-
- Present value: 6
-
- Failure value: 10
-
- Pwr-Cycld value: 8
-
|
power_summary |
Power Usage Summary
|
ps_redun_mode |
Mode: Redundant or Non-redundant
- Non-Redundant(combined) value: 0
-
- Redundant value: 1
-
- Combined(obsolete) value: 2
-
- Non-Redundant value: 3
-
- InSrc-Redundant value: 4
-
- PS-Redundant value: 5
-
|
ps_oper_mode |
Operational Mode
- Non-Redundant(combined) value: 0
-
- Redundant value: 1
-
- Combined(obsolete) value: 2
-
- Non-Redundant value: 3
-
- InSrc-Redundant value: 4
-
- PS-Redundant value: 5
-
|
tot_pow_capacity |
Type: string
Total Power Capacity
|
tot_gridA_capacity |
Type: string
Total Grid-A Capacity
|
tot_gridB_capacity |
Type: string
Total Grid-B Capacity
|
cumulative_power |
Type: string
Total Power of all Inputs
|
tot_pow_out_actual_draw |
Type: string
Total Power Output, Actuals
|
tot_pow_input_actual_draw |
Type: string
Total Power Input, Actuals
|
tot_pow_alloc_budgeted |
Type: string
Total Power Allocated/budgeted
|
available_pow |
Type: string
Remaining Power Available
|
powersup_detail |
PowerSupply Details
|
reserve_sup |
Type: string
Power reserved for Supervisors
|
reserve_xbar |
Type: string
Power reserved for Xbars
|
reserve_fan |
Type: string
Power reserved for Fans
|
reserve_supxbarfan |
Type: string
Total Power reserved for Sups,Xbars,Fans
|
pow_used_by_mods |
Type: string
Power currently used by Modules
|
TABLE_tempinfo |
Environment Temperature
|
tempmod |
Type: string
Module
|
sensor |
Type: string
Sensor name
|
majthres |
Type: string
Major Threshold
|
minthres |
Type: string
Minor Threshold
|
curtemp |
Type: string
Current temperature
|
alarmstatus |
Alarm Status
- Failure value: 0
-
- AccessFailure value: 18
-
- Ok value: 1
-
- MinorAlarm value: 2
-
- MajorAlarm value: 3
-
- MinorAlarm value: 4
-
- Ok value: 5
-
- MajorAlarm value: 6
-
- MinorAlarm value: 7
-
- MajorAlarm value: 8
-
- Ok value: 9
-
- NotPresent value: 10
-
|