Use this procedure to connect the supported User Data Channel (UDC) ports between NCS 1010 nodes and verify their operational status.
Bring up the UDC connection between a node and its peer. The system brings up a UDC port automatically when a supported pluggable is installed and connected to its peer. IOS XR does not model UDC0 and UDC1 as configurable interfaces and does not provide independent enable or disable commands for these ports.
Use the port mapping for the node type and connect the UDC port to the corresponding peer line port.
Supported UDC pluggables
-
ONS-SI-GE-LX=
-
ONS-SC-PTP-1510
-
GLC-TE
For details about the UDC throughput with IPv4 and IPv6 traffic, see Table 2.
Follow these steps to bring up the UDC connection between the node and its peer:
Procedure
The UDC ports are connected to the appropriate peer line ports and are ready to carry UDC traffic.
What to do next
-
Verify the UDC port mapping and operational state using the show controller switch summary command.
RP/0/RP0/CPU0:ios#show controller switch summary -
Verify UDC traffic after an upgrade or downgrade, see Verify UDC port traffic statistics.