Use this procedure to verify the status of all the hardware components installed on NCS 1004.
Before you begin
Ensure that all required hardware components are installed on NCS 1004. For installation details, see the Cisco Network Convergence System 1004 Hardware Installation Guide.
Procedure
-
Enter the show platform command in Cisco IOS XR EXEC mode to display the status of Cisco IOS XR.
Example:
RP/0/RP0/CPU0:ios# show platform Wed Mar 4 06:21:26.929 UTC Node Type State Config state -------------------------------------------------------------------------------- 0/0 NCS1K4-LC-FILLER PRESENT NSHUT 0/1 NCS1K4-1.2T-K9 OPERATIONAL NSHUT 0/2 NCS1K4-1.2TL-K9 OPERATIONAL NSHUT 0/3 NCS1K4-LC-FILLER PRESENT NSHUT 0/RP0/CPU0 NCS1K4-CNTLR-K9(Active) IOS XR RUN NSHUT 0/FT0 NCS1K4-FAN OPERATIONAL NSHUT 0/FT1 NCS1K4-FAN OPERATIONAL NSHUT 0/FT2 NCS1K4-FAN OPERATIONAL NSHUT 0/PM0 NCS1K4-AC-PSU OPERATIONAL NSHUT 0/PM1 NCS1K4-AC-PSU OPERATIONAL NSHUT 0/SC0 NCS1004 OPERATIONAL NSHUTRP/0/RP0/CPU0:ios# show platform Thu May 7 10:03:03.394 UTC Node Type State Config state -------------------------------------------------------------------------------- 0/0 NCS1K4-1.2T-K9 OPERATIONAL NSHUT 0/1 NCS1K4-OTN-XP OPERATIONAL NSHUT 0/2 NCS1K4-OTN-XP OPERATIONAL NSHUT 0/3 NCS1K4-OTN-XP OPERATIONAL NSHUT 0/RP0/CPU0 NCS1K4-CNTLR-K9(Active) IOS XR RUN NSHUT 0/FT0 NCS1K4-FAN OPERATIONAL NSHUT 0/FT1 NCS1K4-FAN OPERATIONAL NSHUT 0/FT2 NCS1K4-FAN OPERATIONAL NSHUT 0/PM0 NCS1K4-DC-PSU OPERATIONAL NSHUT 0/PM1 NCS1K4-DC-PSU OPERATIONAL NSHUT 0/SC0 NCS1004 OPERATIONAL NSHUT- If Cisco IOS XR is not operational, no output appears. Use the show sdr command in Cisco IOS XR mode to verify the state of the service domain router (SDR) on the node.
This example shows sample output of the show sdr command in Cisco IOS XR mode.
RP/0/RP0/CPU0:ios# show sdr Wed Mar 4 06:23:16.143 UTC Type NodeName NodeState RedState PartnerName -------------------------------------------------------------------------------- NCS1K4-LC-FILLER 0/0 PRESENT N/A NCS1K4-1.2T-K9 0/1 OPERATIONAL N/A NCS1K4-1.2TL-K9 0/2 OPERATIONAL N/A NCS1K4-LC-FILLER 0/3 PRESENT N/A RP 0/RP0/CPU0 IOS XR RUN ACTIVE NONE NCS1K4-CNTLR-K9 0/RP0 OPERATIONAL N/A NCS1K4-FAN 0/FT0 OPERATIONAL N/A NCS1K4-FAN 0/FT1 OPERATIONAL N/A NCS1K4-FAN 0/FT2 OPERATIONAL N/A NCS1K4-AC-PSU 0/PM0 OPERATIONAL N/A NCS1K4-AC-PSU 0/PM1 OPERATIONAL N/A NCS1004 0/SC0 OPERATIONAL N/ARP/0/RP0/CPU0:ios# show sdr Thu May 7 10:50:08.651 UTC Type NodeName NodeState RedState PartnerName -------------------------------------------------------------------------------- NCS1K4-1.2T-K9 0/0 OPERATIONAL N/A NCS1K4-OTN-XP 0/1 OPERATIONAL N/A NCS1K4-OTN-XP 0/2 OPERATIONAL N/A NCS1K4-OTN-XP 0/3 OPERATIONAL N/A RP 0/RP0/CPU0 IOS XR RUN ACTIVE NONE NCS1K4-CNTLR-K9 0/RP0 OPERATIONAL N/A NCS1K4-FAN 0/FT0 OPERATIONAL N/A NCS1K4-FAN 0/FT1 OPERATIONAL N/A NCS1K4-FAN 0/FT2 OPERATIONAL N/A NCS1K4-DC-PSU 0/PM0 OPERATIONAL N/A NCS1K4-DC-PSU 0/PM1 OPERATIONAL N/A NCS1004 0/SC0 OPERATIONAL N/A
- If Cisco IOS XR is not operational, no output appears. Use the show sdr command in Cisco IOS XR mode to verify the state of the service domain router (SDR) on the node.
-
Enter the admin command to enter System Admin EXEC mode.
Example:
RP/0/RP0/CPU0:ios# admin -
Enter the show platform command to display the information and status of each node in the system.
Example:
sysadmin-vm:0_RP0# show platform Wed Mar 4 06:24:46.700 UTC+00:00 Location Card Type HW State SW State Config State ---------------------------------------------------------------------------- 0/0 NCS1K4-LC-FILLER PRESENT N/A NSHUT 0/1 NCS1K4-1.2T-K9 OPERATIONAL N/A NSHUT 0/2 NCS1K4-1.2TL-K9 OPERATIONAL N/A NSHUT 0/3 NCS1K4-LC-FILLER PRESENT N/A NSHUT 0/RP0 NCS1K4-CNTLR-K9 OPERATIONAL OPERATIONAL NSHUT 0/FT0 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/FT1 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/FT2 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/PM0 NCS1K4-AC-PSU OPERATIONAL N/A NSHUT 0/PM1 NCS1K4-AC-PSU OPERATIONAL N/A NSHUT 0/SC0 NCS1004 OPERATIONAL N/A NSHUTsysadmin-vm:0_RP0# show platform Thu May 7 10:58:09.331 UTC+00:00 Location Card Type HW State SW State Config State ---------------------------------------------------------------------------- 0/0 NCS1K4-1.2T-K9 OPERATIONAL N/A NSHUT 0/1 NCS1K4-OTN-XP OPERATIONAL N/A NSHUT 0/2 NCS1K4-OTN-XP OPERATIONAL N/A NSHUT 0/3 NCS1K4-OTN-XP OPERATIONAL N/A NSHUT 0/RP0 NCS1K4-CNTLR-K9 OPERATIONAL OPERATIONAL NSHUT 0/FT0 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/FT1 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/FT2 NCS1K4-FAN OPERATIONAL N/A NSHUT 0/PM0 NCS1K4-DC-PSU OPERATIONAL N/A NSHUT 0/PM1 NCS1K4-DC-PSU OPERATIONAL N/A NSHUT 0/SC0 NCS1004 OPERATIONAL N/A NSHUTEnsure that the output displays all NCS 1004 components. Both the hardware and software states must be OPERATIONAL.
The various hardware and software states are:
Hardware states
-
OPERATIONAL: node is operating normally and is fully functional.
-
POWERED_ON: power is on and the node is booting up.
-
FAILED: node is powered on but has encountered an internal failure.
-
PRESENT: node is in intermediate state in the boot sequence.
-
POWERED_OFF: power is off and the node cannot be accessed.
Software states
-
OPERATIONAL: software is operating normally and is fully functional.
-
SW_INACTIVE: software is not completely operational.
-
-
Enter the show inventory command in Cisco IOS XR EXEC mode to display the details of the physical entities of NCS 1004 along with the details of QSFPs.
Example:
RP/0/RP0/CPU0:ios# show inventory Wed Mar 4 05:10:17.107 UTC NAME: "0/0", DESCR: "Network Convergence System 1004 Filler" PID: NCS1K4-LC-FILLER, VID: V01, SN: N/A NAME: "0/1", DESCR: "NCS1K4 12x QSFP28 2 Trunk C-Band DWDM card" PID: NCS1K4-1.2T-K9, VID: V00, SN: CAT2250B0AE NAME: "0/1-Optics0/1/0/2", DESCR: "Cisco 100G QSFP28 AOC Pluggable Optics Module" PID: QSFP-100G-AOC3M , VID: V03, SN: INL22262339-A NAME: "0/1-Optics0/1/0/4", DESCR: "Cisco 100GE QSFP28 SR4 Pluggable Optics Module" PID: QSFP-100G-SR4-S, VID: V03, SN: AVF2219S16U NAME: "0/1-Optics0/1/0/5", DESCR: "Cisco 100G QSFP28 LR4-S Pluggable Optics Module" PID: QSFP-100G-LR4-S, VID: V02, SN: JFQ2145701U NAME: "0/1-Optics0/1/0/6", DESCR: "Cisco 100GE QSFP28 SR4 Pluggable Optics Module" PID: QSFP-100G-SR4-S, VID: ES1, SN: AVF1925G012 NAME: "0/1-Optics0/1/0/7", DESCR: "Cisco 100G QSFP28 LR4-S Pluggable Optics Module" PID: QSFP-100G-LR4-S, VID: V02, SN: JFQ2145706N NAME: "0/1-Optics0/1/0/8", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4, VID: V01, SN: JFQ19026014 NAME: "0/1-Optics0/1/0/9", DESCR: "Cisco 100G QSFP28 LR4-S Pluggable Optics Module" PID: QSFP-100G-LR4-S, VID: V02, SN: OPM220518HS NAME: "0/1-Optics0/1/0/10", DESCR: "Cisco 100G QSFP28 SM-SR Pluggable Optics Module" PID: QSFP-100G-SM-SR, VID: V02, SN: INL21490043 NAME: "0/1-Optics0/1/0/11", DESCR: "Cisco 100G QSFP28 CWDM4 Pluggable Optics Module" PID: QSFP-100G-CWDM4-S , VID: V01, SN: JFQ211930JL NAME: "0/1-Optics0/1/0/12", DESCR: "Cisco 100G QSFP28 CWDM4 Pluggable Optics Module" PID: QSFP-100G-CWDM4-S, VID: V02, SN: JFQ2210801H NAME: "0/2", DESCR: "NCS1K4 12x QSFP28 2 Trunk L-Band DWDM card" PID: NCS1K4-1.2TL-K9 , VID: V00, SN: CAT2337B0S4 NAME: "0/2-Optics0/2/0/2", DESCR: "Cisco 100G QSFP28 AOC Pluggable Optics Module" PID: QSFP-100G-AOC3M, VID: V03, SN: INL22262332-A NAME: "0/2-Optics0/2/0/4", DESCR: "Cisco 100G QSFP28 SM-SR Pluggable Optics Module" PID: QSFP-100G-SM-SR, VID: V02, SN: FNS22070HWF NAME: "0/2-Optics0/2/0/5", DESCR: "Cisco 100G QSFP28 SM-SR Pluggable Optics Module" PID: QSFP-100G-SM-SR, VID: V02, SN: SPT2225302D NAME: "0/2-Optics0/2/0/6", DESCR: "Cisco 100G QSFP28 LR4-S Pluggable Optics Module" PID: QSFP-100G-LR4-S, VID: V02, SN: FNS22310Z1X NAME: "0/2-Optics0/2/0/8", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4, VID: V01, SN: FNS20520R8Z NAME: "0/2-Optics0/2/0/9", DESCR: "Cisco 100G QSFP28 AOC Pluggable Optics Module" PID: QSFP-100G-AOC3M, VID: V03, SN: INL23312282-A NAME: "0/2-Optics0/2/0/10", DESCR: "Cisco 100G QSFP28 AOC Pluggable Optics Module" PID: QSFP-100G-AOC3M, VID: V03, SN: INL23312282-B NAME: "0/2-Optics0/2/0/11", DESCR: "Cisco 100G QSFP28 LR4-S Pluggable Optics Module" PID: QSFP-100G-LR4-S, VID: V02, SN: FNS23080LKF NAME: "0/3", DESCR: "Network Convergence System 1004 Filler" PID: NCS1K4-LC-FILLER, VID: V01, SN: N/A : : :RP/0/RP0/CPU0:ios# show inventory Thu May 7 11:05:13.211 UTC NAME: "0/0", DESCR: "NCS1K4 12x QSFP28 2 Trunk C-Band DWDM card" PID: NCS1K4-1.2T-K9 , VID: V00, SN: CAT2237B25A NAME: "0/0-Optics0/0/0/2", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS2333080E NAME: "0/0-Optics0/0/0/3", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS23330801 NAME: "0/0-Optics0/0/0/4", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS21140GZK NAME: "0/0-Optics0/0/0/6", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS233209CN NAME: "0/0-Optics0/0/0/10", DESCR: "Cisco 40GE QSFP+ LR4 Pluggable Optics Module" PID: QSFP-40G-LR4 , VID: V02, SN: FNS23110TYD NAME: "0/1", DESCR: "NCS1K4 4xDD,8xQSFP28,2xCFP2 DCO OTNXponder" PID: NCS1K4-OTN-XP , VID: V00, SN: CAT2352B007 NAME: "0/1-Optics0/1/0/0", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS2333080J NAME: "0/1-Optics0/1/0/1", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS23330806 NAME: "0/1-Optics0/1/0/2", DESCR: "Cisco 4x10GE QSFP+ MLR Pluggable Optics Module" PID: ONS-QSFP-4X10-MLR , VID: V01, SN: INL21010391 NAME: "0/1-Optics0/1/0/4", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: JFQ20332007 NAME: "0/1-Optics0/1/0/5", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: JFQ20332088 NAME: "0/1-Optics0/1/0/6", DESCR: "Cisco 4x10GE QSFP+ MLR Pluggable Optics Module" PID: ONS-QSFP-4X10-MLR , VID: V01, SN: INL21010471 NAME: "0/1-Optics0/1/0/7", DESCR: "Cisco 4x10GE QSFP+ MLR Pluggable Optics Module" PID: ONS-QSFP-4X10-MLR , VID: V01, SN: INL21010376 NAME: "0/2", DESCR: "NCS1K4 4xDD,8xQSFP28,2xCFP2 DCO OTNXponder" PID: NCS1K4-OTN-XP , VID: V00, SN: CAT2352B015 NAME: "0/2-Optics0/2/0/0", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS20360V1R NAME: "0/2-Optics0/2/0/4", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: JFQ21502017 NAME: "0/2-Optics0/2/0/5", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: JFQ202120DY NAME: "0/3", DESCR: "NCS1K4 4xDD,8xQSFP28,2xCFP2 DCO OTNXponder" PID: NCS1K4-OTN-XP , VID: V00, SN: CAT2352B00A NAME: "0/3-Optics0/3/0/0", DESCR: "Cisco QSFP-100G-LR4 Pluggable Optics Module" PID: ONS-QSFP28-LR4 , VID: V01, SN: FNS23320BS3 NAME: "0/3-Optics0/3/0/4", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: AVP2217S09L NAME: "0/3-Optics0/3/0/5", DESCR: "Cisco 40GE QSFP+ SR4 Pluggable Optics Module" PID: QSFP-40G-SR4 , VID: V03, SN: AVP2107S0RZ NAME: "0/RP0", DESCR: "Network Convergence System 1004 Controller" PID: NCS1K4-CNTLR-K9 , VID: V01, SN: CAT2323B0SG : : : : NAME: "0/PM1", DESCR: "Network Convergence System 1004 DC Power Supply Unit" PID: NCS1K4-DC-PSU , VID: V01, SN: POG2308CT4W