Use this procedure to verify the firmware version on NCS 1004 hardware components to ensure compatibility with the installed Cisco IOS XR image.
The firmware on NCS 1004 hardware components must be compatible with the installed Cisco IOS XR image. NCS 1004 may malfunction if the firmware version is incompatible.
Procedure
| 1. | Enter the show hw-module fpd command in the Cisco IOS XR EXEC mode to display the firmware information of various hardware components of NCS 1004. Example:
In this output, some of the significant fields are:
|
|
| 2. | Enter the show fpd package command to display the FPD image version available with this software release for each hardware component.
|
What to do next
Upgrade all FPDs using the upgrade hw-module location all fpd all command in the Cisco IOS XR EXEC mode. If the upgrade requires a reload, the Status column shows RLOAD REQ.
If reload is required
-
If the FPGA location is 0/RP0, enter the admin hw-module location 0/RP0 reload command. This command reboots only the CPU. This reboot does not impact traffic.
-
If the FPGA location is 0/0, enter the admin hw-module location all reload command. The chassis reboots, which impacts traffic. When the reload is complete, the new FPGA runs the current firmware version.
The upgrade of OTNXP LC_DP_MOD_FW and LC_OPT_MOD_FW FPDs affect traffic. Perform this upgrade during a maintenance window.
If Firmware upgrade fails
If the firmware upgrade fails, enter the show logging command to view more details. Then, upgrade the firmware again using these commands.
Upgrade the firmware version of power modules only when both power modules are present and powered on.