Use this procedure to view and verify alarm information on NCS 1004 to identify any critical system conditions that require attention.


The show alarms command displays alarm information for the NCS 1004. You can view alarms in brief or detailed format. You can also filter alarms by location, card, rack, or system level.

Procedure

Use the show alarms command with the desired options to display alarm information.

show alarms [ brief [ card | rack | system ] [ location location ] [ active | history ] | detail [ card | rack | system ] [ location location ] [ active | clients | history | stats ] ]

This command displays alarms in brief or detail format.

Example:

RP/0/RP0/CPU0:ios# show alarms brief card location 0/RP0/CPU0 active                                                          
Wed Mar  4 06:10:55.959 UTC

------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location        Severity     Group            Set Time                   Description

------------------------------------------------------------------------------------
0/1             Major        FPD_Infra        03/02/2020 07:09:04 UTC    One Or More FPDs Need Upgrade Or Not In Current State

0/2             Major        FPD_Infra        03/03/2020 14:27:33 UTC    One Or More FPDs Need Upgrade Or Not In Current State

0/2             Major        Ethernet         03/03/2020 20:33:33 UTC    HundredGigECtrlr0/2/0/9 - Carrier Loss On The LAN

0/2             Critical     Controller       03/03/2020 20:34:05 UTC    Optics0/2/0/3 - Improper Removal

0/2             NotAlarmed   OTN              03/03/2020 20:34:08 UTC    ODU40/2/0/0/2 - OPUK Client Signal Failure

0/2             NotAlarmed   OTN              03/03/2020 20:34:05 UTC    ODU40/2/0/1/2 - OPUK Client Signal Failure
RP/0/RP0/CPU0:ios# show alarms brief card location 0/RP0/CPU0 active                                                          
Fri May  8 04:46:29.582 UTC

------------------------------------------------------------------------------------
Active Alarms
------------------------------------------------------------------------------------
Location        Severity     Group            Set Time                   Description

------------------------------------------------------------------------------------
0/2             NotReported  OTN              05/07/2020 14:25:05 UTC    ODU20/2/0/0/2/3 - Path Monitoring Alarm Indication Signal

0/2             NotReported  OTN              05/07/2020 14:25:05 UTC    ODU2E0/2/0/0/2/4 - Path Monitoring Alarm Indication Signal

0/1             NotReported  OTN              05/07/2020 14:24:41 UTC    ODU20/1/0/0/2/3 - Path Monitoring Alarm Indication Signal

0/1             NotReported  OTN              05/07/2020 14:25:03 UTC    ODU20/1/0/1/11/3 - Path Monitoring Alarm Indication Signal

0/1             NotReported  OTN              05/07/2020 14:25:03 UTC    ODU2E0/1/0/1/11/4 - Path Monitoring Alarm Indication Signal

0/3             NotReported  OTN              05/07/2020 14:24:41 UTC    ODU20/3/0/0/2/3 - Path Monitoring Alarm Indication Signal

0/3             NotReported  OTN              05/07/2020 14:24:41 UTC    ODU2E0/3/0/0/2/4 - Path Monitoring Alarm Indication Signal

0/1             Major        Ethernet         05/07/2020 14:24:41 UTC    TenGigECtrlr0/1/0/4/1 - Remote Fault
Note

In maintenance mode, all alarms are suppressed and the show alarms command will not display alarms details. Use the show controllers controllertype R/S/I/P command to view the client and trunk alarms.

Review the alarm output to identify any critical or major alarms that require immediate attention. Resolve these alarms before making additional configurations.