Procedure
| 1. | Use the configure terminal command to enter global configuration mode. Example:
|
|
| 2. | Use the alarm facility temperature { primary | secondary } high threshold command to set the high temperature threshold. Example:
You can specify a threshold value between -40°F (–40°C) and 204.8°F (96°C). |
|
| 3. | Use the alarm facility temperature { primary | secondary } low threshold command to set the low temperature threshold. Example:
You can specify a threshold value between -40°F (–40°C) and 204.8°F (96°C).. |
|
| 4. | Use the end command command to exit to privileged EXEC mode. Example:
|
|