Configure temperature alarms to ensure critical temperature notifications are routed via relay, SNMP, or syslog.
Follow this procedure to associate temperature alarms with a relay to ensure that critical temperature notifications are routed appropriately.
Procedure
| 1. | Use the configure terminal command to enter global configuration mode. Example:
|
|
| 2. | Use the alarm facility temperature { primary | secondary } relay major command to link either the primary or secondary temperature alarm to the major relay. Example:
|
|
| 3. | (Optional) Use the alarm facility temperature { primary | secondary } notifies command to send primary or secondary temperature alarm traps to an SNMP server. Example:
|
|
| 4. | (Optional) Use the alarm facility temperature { primary | secondary } syslog command to send primary or secondary temperature alarm traps to a syslog server. Example:
|
|
| 5. | (Optional) Use the no alarm facility temperature secondary command to turn off the secondary temperature alarm. Example:
|
|
| 6. | Use the end command to exit to the privileged EXEC mode. Example:
|
|
| 7. | Use the show alarm settings command to confirm that temperature alarms are configured correctly. Example:
|