Configure the G.8032 Ethernet Ring profile to specify operational and configuration parameters for your network requirements.
Configure the G.8032 Ethernet Ring profile to define operational and configuration parameters for your network.
The G.8032 Ethernet Ring profile specifies the operational and configuration parameters for particular network requirements. You can use the default profile or create a custom one using this procedure.
Before you begin
Ensure you have access to device configuration mode on your network switch.
Procedure
| 1. | Use the ethernet ring g8032 profile profile-name command to create the Ethernet ring profile and enter Ethernet ring profile configuration mode. Example:
|
|
| 2. | (Optional) Use the timer WTR minutes command to set the duration for the Wait-to-Restore (WTR) timer. Example:
The valid range is 1 to 12; the default is 5 minutes. |
|
| 3. | (Optional) Use the timer guard interval command to set the duration for the guard timer. Example:
The valid range is 10 to 2000; the default is 500 milliseconds. |
|
| 4. | (Optional) Use the timer hold-off seconds command to set the duration for the hold-off timer. Example:
The valid range is 0 to 10; the default is 0 seconds. |
|
| 5. | (Optional) Use the no non-revertive command to configure a nonrevertive Ethernet ring instance. Example:
By default, revertive mode is enabled. |