Configuring Volume Metering
Follow the procedure given below to configure volume metering:
Procedure
| Command or Action | Purpose | |
|---|---|---|
| 
                                     Step 1  | 
                                 
                                     configure terminal Example:
                                        | 
                                 
                                     Enters global configuration mode.  | 
                              
| 
                                     Step 2  | 
                                 
                                     ap profile profile-name Example:
                                        | 
                                 
                                     Configures an AP profile and enters ap profile configuration mode.  | 
                              
| 
                                     Step 3  | 
                                 
                                     dot11 24ghz reporting-interval reporting-interval Example:
                                        | 
                                 
                                     Configures the dot11 parameters.  | 
                              
| 
                                     Step 4  | 
                                 
                                     dot11 5ghz reporting-interval reporting-interval Example:
                                        | 
                                 
                                     Configures the dot11 parameters.  | 
                              
| 
                                     Step 5  | 
                                 
                                     exit Example:
                                        | 
                                 
                                     Returns to global configuration mode.  | 
                              
| 
                                     Step 6  | 
                                 
                                     aaa accounting update periodic interval-in-minutes Example:
                                        | 
                                 
                                     Sets the time interval (in minutes) at which the controller sends interim accounting updates of the client to the RADIUS server.  | 
                              
| 
                                     Step 7  | 
                                 
                                     exit Example:
                                        | 
                                 
                                     Exits configuration mode and returns to privileged EXEC mode.  | 
                              
Feedback