Server Specifications
This appendix lists the physical, environmental, and power specifications for the server.
Physical Specifications
The following table lists the physical specifications for the server.
Description |
Specification |
Height |
1.7 in. (43.2 mm) |
Width |
16.9 in. (429.0 mm) |
Depth (length) |
Server only: 30 in. (762 mm) Server with slide rail: 31.5 in (800.1 mm) |
Weight |
|
Environmental Specifications
As a Class A2 product, the server has the following environmental specifications.
Description |
Specification |
Temperature, Operating |
Dry bulb temperature of 10°C to 35°C (50°F to 95°F) Maximum temperature change of 20°C (36°F) per hour (a temperature change within a specified period of time and not a rate of change) Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, Extended Operating |
5°C to 40°C (41°F to 104°F) with no direct sunlight Humidity condition: Uncontrolled, not to exceed 50% RH starting condition Derate the maximum temperature by 1°C (33.8°F) per every 305 meters of altitude above 900m |
Temperature, non-operating (when the server is stored or transported) |
Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F) |
Humidity (RH), operating |
10% to 90% and 28°C (82.4°F) maximum dew-point temperature, non-condensing environment Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity |
Humidity (RH), non-operating (when the server is stored or transported) |
5% to 93% relative humidity, non-condensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range. |
Altitude, operating |
A maximum elevation of 3050 meters (10,006 feet) |
Altitude, non-operating (when the server is stored or transported) |
An elevation of 0 to 12,000 meters (39,370 feet) |
Maximum Operating Duration |
Unlimited |
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |
Power Specifications
![]() Note |
Do not mix power supply types or wattages in the server. Both power supplies must be identical. |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
1050 W V2 DC Power Supply
This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV21050D-D). This power supply is Platinum rated.
![]() Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
Molex 42820 |
|||
Input Voltage Range (V rms) |
-48 |
|||
Maximum Allowable Input Voltage Range (V rms) |
-40 to -72 |
|||
Frequency Range (Hz) |
NA |
|||
Maximum Allowable Frequency Range (Hz) |
NA |
|||
Maximum Rated Output (W) |
1050 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
-48 |
|||
Nominal Input Current (A rms) |
24 |
|||
Maximum Input at Nominal Input Voltage (W) |
1154 |
|||
Maximum Input at Nominal Input Voltage (VA) |
1154 |
|||
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
91 |
|||
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
NA |
|||
Maximum Inrush Current (peak A) |
15 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time This is the time output voltage remains within regulation limits at 100% load, during input voltage dropout |
5 |
1200 W AC Power Supply
This section lists the specifications for each 1050 W AC power supply (Cisco part number UCSC-PSU1-1200W-D).
Description |
Specification |
AC input voltage |
Range: 100–230 VAC |
AC input frequency |
Range: 50 to 60Hz |
Maximum AC input current |
12.97 A at 100 VAC |
Maximum input volt-amperes |
1345 VA at 208 VAC |
Maximum inrush current |
20 A |
Maximum hold-up time |
12 ms at 1200 W |
Maximum output power per PSU |
1100 W at 100–120 VAC 1200 W at 208–230 VAC |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
Climate Savers Platinum Efficiency (80Plus Titanium certified) |
Form factor |
RSP2 |
Input connector |
IEC320 C14 |
1600 W AC Power Supply
This section lists the specifications for each 1600 W AC power supply (Cisco part number UCSC-PSU1-1600W-D). This power supply is Platinum rated.
![]() Note |
For the 80PLUS platinum certification documented in the following table, you can find test results at https://www.clearesult.com/80plus/. |
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
IEC320 C14 |
|||
Input Voltage Range (V rms) |
200 to 240 |
|||
Maximum Allowable Input Voltage Range (V rms) |
180 to 264 |
|||
Frequency Range (Hz) |
50 to 60 |
|||
Maximum Allowable Frequency Range (Hz) |
47 to 63 |
|||
Maximum Rated Output (W) Limited to 800W when operating at low-line input voltage, 100-127 V |
1600 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
100 |
120 |
208 |
230 |
Nominal Input Current (A rms) |
NA |
NA |
8.8 |
7.9 |
Maximum Input at Nominal Input Voltage (W) |
NA |
NA |
1778 |
1758 |
Maximum Input at Nominal Input Voltage (VA) |
NA |
NA |
1833 |
1813 |
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
NA |
NA |
90 |
91 |
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
NA |
NA |
0.97 |
0.97 |
Maximum Inrush Current (peak A) |
30 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time The time that the output voltage remains within regulation limits at 100% load, during input voltage dropout |
12 |
2300 W AC Power Supply
This section lists the specifications for each 2300 W AC power supply (Cisco part number UCSC-PSU1-2300W-D). This power supply is Titanium rated.
Parameter |
Specification |
|||
---|---|---|---|---|
Input Connector |
IEC320 C20 |
|||
Input Voltage Range (V rms) |
100 to 240 |
|||
Maximum Allowable Input Voltage Range (V rms) |
90 to 264 |
|||
Frequency Range (Hz) |
50 to 60 |
|||
Maximum Allowable Frequency Range (Hz) |
47 to 63 |
|||
Maximum Rated Output (W) Limited to 800W when operating at low-line input voltage, 100-127 V |
2300 |
|||
Maximum Rated Standby Output (W) |
36 |
|||
Nominal Input Voltage (V rms) |
100 |
120 |
208 |
230 |
Nominal Input Current (A rms) |
13 |
11 |
12 |
10.8 |
Maximum Input at Nominal Input Voltage (W) |
1338 |
1330 |
2490 |
2480 |
Maximum Input at Nominal Input Voltage (VA) |
1351 |
1343 |
2515 |
2505 |
Maximum Rated Efficiency (%) Minimum rating required to achieve 80PLUS platinum certification. |
92 |
92 |
93 |
93 |
Maximum Rated Power Factor Minimum rating required to achieve 80PLUS platinum certification. |
0.99 |
0.99 |
0.97 |
0.97 |
Maximum Inrush Current (peak A) |
30 |
|||
Maximum Inrush Current (ms) |
0.2 |
|||
Maximum Ride-Through Time Time output voltage remains within regulation limits at 100% load, during input voltage dropout |
12 |