Configuring Smart Call Home

This chapter contains the following sections:

Configuring Smart Call Home

Information About Call Home

Call Home provides e-mail-based notification of critical system events. Cisco Nexus 5000 Series switches provide a range of message formats for optimal compatibility with pager services, standard e-mail, or XML-based automated parsing applications. You can use this feature to page a network support engineer, e-mail a Network Operations Center, or use Cisco Smart Call Home services to automatically generate a case with the Technical Assistance Center.

Call Home Overview

You can use Call Home to notify an external entity when an important event occurs on your device. Call Home delivers alerts to multiple recipients that you configure in destination profiles.

Call Home includes a fixed set of predefined alerts on your switch. These alerts are grouped into alert groups and CLI commands to are assigned to execute when an alert in an alert group occurs. The switch includes the command output in the transmitted Call Home message.

The Call Home feature offers the following advantages:

  • Automatic execution and attachment of relevant CLI command output.

  • Multiple message format options such as the following:

    • Short Text—Suitable for pagers or printed reports.

    • Full Text—Fully formatted message information suitable for human reading.

    • XML—Matching readable format that uses the Extensible Markup Language (XML) and the Adaptive Messaging Language (AML) XML schema definition (XSD). The XML format enables communication with the Cisco Systems Technical Assistance Center (Cisco-TAC).

  • Multiple concurrent message destinations. You can configure up to 50 e-mail destination addresses for each destination profile.

Destination Profiles

A destination profile includes the following information:

  • One or more alert groups—The group of alerts that trigger a specific Call Home message if the alert occurs.

  • One or more e-mail destinations—The list of receipents for the Call Home messages generated by alert groups assigned to this destination profile.

  • Message format—The format for the Call Home message (short text, full text, or XML).

  • Message severity level—The Call Home severity level that the alert must meet before the switch generates a Call Home message to all e-mail addresses in the destination profile. The Cisco Nexus 5000 Series switch does not generate an alert if the Call Home severity level of the alert is lower than the message severity level set for the destination profile.

You can also configure a destination profile to allow periodic inventory update messages by using the inventory alert group that will send out periodic messages daily, weekly, or monthly.

Cisco Nexus 5000 Series switches support the following predefined destination profiles:

  • CiscoTAC-1—Supports the Cisco-TAC alert group in XML message format.

  • full-text-destination—Supports the full text message format.

  • short-text-destination—Supports the short text message format.

Call Home Alert Groups

An alert group is a predefined subset of Call Home alerts that are supported in all Cisco Nexus 5000 Series switches. Alert groups allow you to select the set of Call Home alerts that you want to send to a predefined or custom destination profile. The switch sends Call Home alerts to e-mail destinations in a destination profile only if that Call Home alert belongs to one of the alert groups associated with that destination profile and if the alert has a Call Home message severity at or above the message severity set in the destination profile.

The following table lists supported alert groups and the default CLI command output included in Call Home messages generated for the alert group.

Table 1  Alert Groups and Executed Commands

Alert Group

Description

Executed Commands

Cisco-TAC

All critical alerts from the other alert groups destined for Smart Call Home.

Execute commands based on the alert group that originates the alert.

Diagnostic

Events generated by diagnostics.

show diagnostic result module all detail

show moduleshow version

show tech-support platform callhome

Supervisor hardware

Events related to supervisor modules.

show diagnostic result module all detail

show moduleshow version

show tech-support platform callhome

Linecard hardware

Events related to standard or intelligent switching modules.

show diagnostic result module all detail

show moduleshow version

show tech-support platform callhome

Configuration

Periodic events related to configuration.

show version

show module

show running-config all

show startup-config

System

Events generated by failure of a software system that is critical to unit operation.

show system redundancy status

show tech-support

Environmental

Events related to power, fan, and environment-sensing elements such as temperature alarms.

show environment

show logging last 1000

show module show version

show tech-support platform callhome

Inventory

Inventory status that is provided whenever a unit is cold booted, or when FRUs are inserted or removed. This alert is considered a noncritical event, and the information is used for status and entitlement.

show module

show version

show license usage

show inventory

show sprom all

show system uptime

Call Home maps the syslog severity level to the corresponding Call Home severity level for syslog port group messages

You can customize predefined alert groups to execute additional CLI show commands when specific events occur and send that show output with the Call Home message.

You can add show commands only to full text and XML destination profiles. Short text destination profiles do not support additional show commands because they only allow 128 bytes of text.

Related Information
Call Home Message Levels

Call Home Message Levels

Call Home allows you to filter messages based on their level of urgency. You can associate each destination profile (predefined and user defined) with a Call Home message level threshold. The switch does not generate any Call Home messages with a value lower than this threshold for the destination profile. The Call Home message level ranges from 0 (lowest level of urgency) to 9 (highest level of urgency), and the default is 0 ( Cisco Nexus 5000 Series sends all messages).

Call Home messages that are sent for syslog alert groups have the syslog severity level mapped to the Call Home message level.


Note


Call Home does not change the syslog message level in the message text.


The following table lists each Call Home message level keyword and the corresponding syslog level for the syslog port alert group.

Table 2  Severity and syslog Level Mapping

Call Home Level

Keyword

syslog Level

Description

9

Catastrophic

N/A

Network-wide catastrophic failure.

8

Disaster

N/A

Significant network impact.

7

Fatal

Emergency (0)

System is unusable.

6

Critical

Alert (1)

Critical conditions that indicate that immediate attention is needed.

5

Major

Critical (2)

Major conditions.

4

Minor

Error (3)

Minor conditions.

3

Warning

Warning (4)

Warning conditions.

2

Notification

Notice (5)

Basic notification and informational messages. Possibly independently insignificant.

1

Normal

Information (6)

Normal event signifying return to normal state.

0

Debugging

Debug (7)

Debugging messages.

Obtaining Smart Call Home

If you have a service contract directly with Cisco Systems, you can register your devices for the Smart Call Home service. Smart Call Home provides fast resolution of system problems by analyzing Call Home messages sent from your devices and providing background information and recommendations. For issues that can be identified as known, particularly GOLD diagnostics failures, Automatic Service Requests will be generated with the Cisco-TAC.

Smart Call Home offers the following features:

  • Continuous device health monitoring and real-time diagnostic alerts.

  • Analysis of Call Home messages from your device and, where appropriate, Automatic Service Request generation, routed to the appropriate TAC team, including detailed diagnostic information to speed problem resolution.

  • Secure message transport directly from your device or through a downloadable Transport Gateway (TG) aggregation point. You can use a TG aggregation point in cases that require support for multiple devices or in cases where security requirements mandate that your devices may not be connected directly to the Internet.

  • Web-based access to Call Home messages and recommendations, inventory and configuration information for all Call Home devices. Provides access to associated field notices, security advisories and end-of-life information.

You need the following items to register:

  • The SMARTnet contract number for your switch.

  • Your e-mail address

  • Your Cisco.com ID

For more information about Smart Call Home, see the Smart Call Home page at this URL: http:/​/​www.cisco.com/​go/​smartcall/​

Prerequisites for Call Home

Call Home has the following prerequisites:

  • You must configure an e-mail server.

  • You must configure the contact name (SNMP server contact), phone, and street address information before you enable Call Home. This step is required to determine the origin of messages received.

  • Your switch must have IP connectivity to an e-mail server.

  • If you use Smart Call Home, you need an active service contract for the device that you are configuring.

Configuration Guidelines and Limitations

Call Home has the following configuration guidelines and limitations:

  • If there is no IP connectivity or if the interface in the VRF to the profile destination is down, the switch cannot send the Call Home message.

  • Operates with any SMTP server.

Configuring Call Home

Procedures for Configuring Call Home

SUMMARY STEPS

    1.    Assign contact information.

    2.    Configure destination profiles.

    3.    Associate one or more alert groups to each profile.

    4.    (Optional) Add additional show commands to the alert groups.

    5.    Configure transport options.

    6.    Enable Call Home.

    7.    (Optional) Test Call Home messages.


DETAILED STEPS
    Step 1   Assign contact information.
    Step 2   Configure destination profiles.
    Step 3   Associate one or more alert groups to each profile.
    Step 4   (Optional)Add additional show commands to the alert groups.
    Step 5   Configure transport options.
    Step 6   Enable Call Home.
    Step 7   (Optional) Test Call Home messages.

    Configuring Contact Information

    You must configure the e-mail, phone, and street address information for Call Home. You can optionally configure the contract ID, customer ID, site ID, and switch priority information.

    SUMMARY STEPS

      1.    switch# configuration terminal

      2.    switch(config)# snmp-server contact sys-contact

      3.    switch(config)# callhome

      4.    switch(config-callhome)# email-contact email-address

      5.    switch(config-callhome)# phone-contact international-phone-number

      6.    switch(config-callhome)# streetaddress address

      7.    (Optional) switch(config-callhome)# contract-id contract-number

      8.    (Optional) switch(config-callhome)# customer-id customer-number

      9.    (Optional) switch(config-callhome)# site-id site-number

      10.    (Optional) switch(config-callhome)# switch-priority number

      11.    (Optional) switch# show callhome

      12.    (Optional) switch# copy running-config startup-config


    DETAILED STEPS
       Command or ActionPurpose
      Step 1 switch# configuration terminal
       

      Enters configuration mode.

       
      Step 2 switch(config)# snmp-server contact sys-contact
       

      Configures the SNMP sysContact.

       
      Step 3 switch(config)# callhome
       

      Enters callhome configuration mode.

       
      Step 4 switch(config-callhome)# email-contact email-address
       

      Configures the e-mail address for the primary person responsible for the switch. Up to 255 alphanumeric characters are accepted in e-mail address format.

      Note   

      You can use any valid e-mail address. The address cannot contain spaces.

       
      Step 5 switch(config-callhome)# phone-contact international-phone-number
       

      Configures the phone number in international phone number format for the primary person responsible for the device. Up to 17 alphanumeric characters are accepted in international format.

      Note   

      The phone number cannot contain spaces. Be sure to use the + prefix before the number.

       
      Step 6 switch(config-callhome)# streetaddress address
       

      Configures the street address as an alphanumeric string with white paces for the primary person responsible for the switch. Up to 255 alphanumeric characters are accepted, including spaces.

       
      Step 7 switch(config-callhome)# contract-id contract-number
       
      (Optional)

      Configures the contract number for this switch from the service agreement. The contract number can be up to 255 alphanumeric characters in free format.

       
      Step 8 switch(config-callhome)# customer-id customer-number
       
      (Optional)

      Configures the customer number for this switch from the service agreement. The customer number can be up to 255 alphanumeric characters in free format.

       
      Step 9 switch(config-callhome)# site-id site-number
       
      (Optional)

      Configures the site number for this switch. The site number can be up to 255 alphanumeric characters in free format.

       
      Step 10 switch(config-callhome)# switch-priority number
       
      (Optional)

      Configures the switch priority for this switch. The range is from 0 to 7, with 0 being the highest priority and 7 the lowest. The default is 7.

       
      Step 11 switch# show callhome
       
      (Optional)

      Displays a summary of the Call Home configuration.

       
      Step 12 switch# copy running-config startup-config
       
      (Optional)

      Saves this configuration change.

       

      This example shows how to configure the contact information for Call Home:

      switch# configuration terminal
      
      switch(config)# snmp-server contact personname@companyname.com
      
      switch(config)# callhome
      
      switch(config-callhome)# email-contact personname@companyname.com
      
      switch(config-callhome)# phone-contact +1-800-123-4567
      
      switch(config-callhome)# street-address 123 Anystreet St., Anycity, Anywhere
      
       

      Creating a Destination Profile

      You must create a user-defined destination profile and configure the message format for that new destination profile.

      SUMMARY STEPS

        1.    switch# configuration terminal

        2.    switch(config)# callhome

        3.    switch(config-callhome)# destination-profile {ciscoTAC-1 {alert-group group | email-addr address | http URL | transport-method {email | http}} | profile-name {alert-group group | email-addr address | format {XML | full-txt | short-txt} | http URL | message-level level | message-size size | transport-method {email | http}} | full-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}} | short-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}}}

        4.    (Optional) switch# show callhome destination-profile [profile name]

        5.    (Optional) switch# copy running-config startup-config


      DETAILED STEPS
         Command or ActionPurpose
        Step 1 switch# configuration terminal
         

        Enters configuration mode.

         
        Step 2 switch(config)# callhome
         

        Enters callhome configuration mode.

         
        Step 3 switch(config-callhome)# destination-profile {ciscoTAC-1 {alert-group group | email-addr address | http URL | transport-method {email | http}} | profile-name {alert-group group | email-addr address | format {XML | full-txt | short-txt} | http URL | message-level level | message-size size | transport-method {email | http}} | full-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}} | short-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}}}
         

        Creates a new destination profile and sets the message format for the profile. The profile-name can be any alphanumeric string up to 31 characters.

        For further details about this command, see the Cisco Nexus 5000 Series Command Reference.

         
        Step 4 switch# show callhome destination-profile [profile name]
         
        (Optional)

        Displays information about one or more destination profiles.

         
        Step 5 switch# copy running-config startup-config
         
        (Optional)

        Saves this configuration change.

         

        This example shows how to create a destination profile for Call Home:

        switch# configuration terminal
        switch(config)# callhome
        switch(config-callhome)# destination-profile Noc101 format full-text
         

        Modifying a Destination Profile

        You can modify the following attributes for a predefined or user-defined destination profile:

        • Destination address—The actual address, pertinent to the transport mechanism, to which the alert should be sent.

        • Message formatting—The message format used for sending the alert (full text, short text, or XML).

        • Message level—The Call Home message severity level for this destination profile.

        • Message size—The allowed length of a Call Home message sent to the e-mail addresses in this destination profile.


        Note


        You cannot modify or delete the CiscoTAC-1 destination profile.


        SUMMARY STEPS

          1.    switch# configuration terminal

          2.    switch(config)# callhome

          3.    switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} email-addr address

          4.    destination-profile {name | full-txt-destination | short-txt-destination} message-level number

          5.    switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} message-size number

          6.    (Optional) switch# show callhome destination-profile [profile name]

          7.    (Optional) switch# copy running-config startup-config


        DETAILED STEPS
           Command or ActionPurpose
          Step 1 switch# configuration terminal
           

          Enters configuration mode.

           
          Step 2 switch(config)# callhome
           

          Enters callhome configuration mode.

           
          Step 3 switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} email-addr address
           

          Configures an e-mail address for a user-defined or predefined destination profile. You can configure up to 50 e-mail addresses in a destination profile.

           
          Step 4 destination-profile {name | full-txt-destination | short-txt-destination} message-level number
           

          Configures the Call Home message severity level for this destination profile. The switch sends only alerts that have a matching or higher Call Home severity level to destinations in this profile. The range is from 0 to 9, where 9 is the highest severity level.

           
          Step 5 switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} message-size number
           

          Configures the maximum message size for this destination profile. The range is from 0 to 5000000 for full-txt-destination and the default is 2500000; from 0 to 100000 for short-txt-destination and the default is 4000; 5000000 for CiscoTAC-1, which is not changeable.

           
          Step 6 switch# show callhome destination-profile [profile name]
           
          (Optional)

          Displays information about one or more destination profiles.

           
          Step 7 switch# copy running-config startup-config
           
          (Optional)

          Saves this configuration change.

           

          This example shows how to modify a destination profile for Call Home:

          switch# configuration terminal
          switch(config)# callhome
          switch(config-callhome)# destination-profile full-text-destination email-addr person@example.com
          switch(config-callhome)# destination-profile full-text-destination message-level 5
          switch(config-callhome)# destination-profile full-text-destination message-size 10000
           
          Related Information
          Associating an Alert Group with a Destination Profile

          Associating an Alert Group with a Destination Profile

          To associate one or more alert groups with a destination profile, perform this task:

          SUMMARY STEPS

            1.    switch# configuration terminal

            2.    switch(config)# callhome

            3.    switch(config-callhome)# destination-profile name alert-group {All | Cisco-TAC | Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test}

            4.    (Optional) switch# show callhome destination-profile [profile name]

            5.    (Optional) switch# copy running-config startup-config


          DETAILED STEPS
             Command or ActionPurpose
            Step 1 switch# configuration terminal
             

            Enters configuration mode.

             
            Step 2 switch(config)# callhome
             

            Enters callhome configuration mode.

             
            Step 3 switch(config-callhome)# destination-profile name alert-group {All | Cisco-TAC | Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test}
             

            Associates an alert group with this destination profile. Use the All keyword to associate all alert groups with the destination profile.

             
            Step 4 switch# show callhome destination-profile [profile name]
             
            (Optional)

            Displays information about one or more destination profiles.

             
            Step 5 switch# copy running-config startup-config
             
            (Optional)

            Saves this configuration change.

             

            This example shows how to associate all alert groups with the destination profile Noc101:

            switch# configuration terminal
            
            switch(config)# callhome
            
            switch(config-callhome)# destination-profile Noc101 alert-group All
            
             

            Adding show Commands to an Alert Group

            You can assign a maximum of five user-defined CLI show commands to an alert group.

            SUMMARY STEPS

              1.    switch# configuration terminal

              2.    switch(config)# callhome

              3.    switch(config-callhome)# alert-group {Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test} user-def-cmd show-cmd

              4.    (Optional) switch# show callhome user-def-cmds

              5.    (Optional) switch# copy running-config startup-config


            DETAILED STEPS
               Command or ActionPurpose
              Step 1 switch# configuration terminal
               

              Enters configuration mode.

               
              Step 2 switch(config)# callhome
               

              Enters callhome configuration mode.

               
              Step 3 switch(config-callhome)# alert-group {Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test} user-def-cmd show-cmd
               

              Adds the show command output to any Call Home messages sent for this alert group. You must enclose the show command in double quotes. Only valid show commands are accepted.

              Note   

              You cannot add user-defined CLI show commands to the CiscoTAC-1 destination profile.

               
              Step 4 switch# show callhome user-def-cmds
               
              (Optional)

              Displays information about all user-defined show commands added to alert groups.

               
              Step 5 switch# copy running-config startup-config
               
              (Optional)

              Saves this configuration change.

               

              This example shows how to add the show ip routing command o the Cisco-TAC alert group:

              switch# configuration terminal
              
              switch(config)# callhome
              
              switch(config-callhome)# alert-group Configuration user-def-cmd "show ip routing"
              
               

              Configuring E-Mail

              You must configure the SMTP server address for the Call Home functionality to work. You can also configure the from and reply-to e-mail addresses.

              SUMMARY STEPS

                1.    switch# configuration terminal

                2.    switch(config)# callhome

                3.    switch(config-callhome)# transport email smtp-server ip-address [port number] [use-vrf vrf-name]

                4.    (Optional) switch(config-callhome)# transport email from email-address

                5.    (Optional) switch(config-callhome)# transport email reply-to email-address

                6.    (Optional) switch# show callhome transport-email

                7.    (Optional) switch# copy running-config startup-config


              DETAILED STEPS
                 Command or ActionPurpose
                Step 1 switch# configuration terminal
                 

                Enters configuration mode.

                 
                Step 2 switch(config)# callhome
                 

                Enters callhome configuration mode.

                 
                Step 3 switch(config-callhome)# transport email smtp-server ip-address [port number] [use-vrf vrf-name]
                 

                Configures the SMTP server as either the domain name server (DNS) name, IPv4 address, or IPv6 address). Optionally you can configure the port number. The port ranges is from 1 to 65535. The default port number is 25.

                Also optionally you can configure the VRF to use when communicating with this SMTP server.

                 
                Step 4 switch(config-callhome)# transport email from email-address
                 
                (Optional)

                Configures the e-mail from field for Call Home messages.

                 
                Step 5 switch(config-callhome)# transport email reply-to email-address
                 
                (Optional)

                Configures the e-mail reply-to field for Call Home messages.

                 
                Step 6 switch# show callhome transport-email
                 
                (Optional)

                Displays information about the e-mail configuration for Call Home.

                 
                Step 7 switch# copy running-config startup-config
                 
                (Optional)

                Saves this configuration change.

                 

                This example shows how to configure the e-mail options for Call Home messages:

                switch# configuration terminal
                
                switch(config)# callhome
                
                switch(config-callhome)# transport email smtp-server 192.0.2.10 use-vrf Red
                
                switch(config-callhome)# transport email from person@example.com
                
                switch(config-callhome)# transport email reply-to person@example.com
                
                 

                Configuring Periodic Inventory Notification

                You can configure the switch to periodically send a message with an inventory of all software services currently enabled and running on the device along with hardware inventory information. The switch generates two Call Home notifications; periodic configuration messages and periodic inventory messages.

                SUMMARY STEPS

                  1.    switch# configuration terminal

                  2.    switch(config)# callhome

                  3.    switch(config-callhome)# periodic-inventory notification [interval days] [timeofday time]

                  4.    (Optional) switch# show callhome

                  5.    (Optional) switch# copy running-config startup-config


                DETAILED STEPS
                   Command or ActionPurpose
                  Step 1 switch# configuration terminal
                   

                  Enters configuration mode.

                   
                  Step 2 switch(config)# callhome
                   

                  Enters callhome configuration mode.

                   
                  Step 3 switch(config-callhome)# periodic-inventory notification [interval days] [timeofday time]
                   

                  Configures the periodic inventory messages. The interval range is from 1 to 30 days. The default is 7 days. The timeofday value is in HH:MM format.

                   
                  Step 4 switch# show callhome
                   
                  (Optional)

                  Displays information about Call Home.

                   
                  Step 5 switch# copy running-config startup-config
                   
                  (Optional)

                  Saves this configuration change.

                   

                  This example shows how to configure the periodic inventory messages to generate every 20 days:

                  switch# configuration terminal
                  
                  switch(config)# callhome
                  
                  switch(config-callhome)# periodic-inventory notification interval 20
                  
                   

                  Disabling Duplicate Message Throttle

                  You can limit the number of duplicate messages received for the same event. By default, the switch limits the number of duplicate messages received for the same event. If the number of duplicate messages sent exceeds 30 messages within a 2-hour time frame, then the switch discards further messages for that alert type.

                  Command

                  Purpose

                  switch(config-callhome)# no duplicate-message throttle

                  Disables duplicate message throttling for Call Home. Enabled by default.

                  Enabling or Disabling Call Home

                  Once you have configured the contact information, you can enable the Call Home function in callhome configuration mode.

                  Command

                  Purpose

                  switch(config-callhome)# enable

                  Enables Call Home. Disabled by default.

                  You can disable Call Home in the callhome configuration mode.

                  Command

                  Purpose

                  switch(config-callhome)# no enable

                  Disables Call Home. Disabled by default

                  You can enable Call Home distribution using CFS in the callhome configuration mode.

                  Command

                  Purpose

                  switch(config-callhome)# distribute

                  Enables Call Home distribution using CFS. Disabled by default.

                  You can commit Call Home configuration changes and distribute using CFS in the callhome configuration mode.

                  Command

                  Purpose

                  switch(config-callhome)# commit

                  Commits Call Home configuration changes and distributes the changes to call CFS-enabled devices.

                  You can discard Call Home configuration changes and release the CFS lock in callhome configuration mode.

                  Command

                  Purpose

                  switch(config-callhome)# abort

                  Discards Call Home configuration changes and releases the CFS lock. Use this command if you are the CFS lock owner or if you are logged into the device that holds the CFS lock

                  Testing Call Home Communications

                  You can generate a test message to test your Call Home communications.

                  Command

                  Purpose

                  switch(config-callhome)# callhome send diagnostic

                  Sends the specified Call Home test message to all configured destinations.

                  switch(config-callhome)# callhome test

                  Sends a test message to all configured destinations.

                  callhome test and callhome test inventory commands are supported.

                  Verifying Call Home Configuration

                  To display Call Home configuration information, perform one of the following tasks:

                  Command

                  Purpose

                  switch# show callhome

                  Displays the status for Call Home.

                  switch# show callhome destination-profile name

                  Displays one or more Call Home destination profiles.

                  switch# show callhome merge

                  Displays the status of the last CFS merge for Call Home.

                  switch# show callhome pending

                  Displays the Call Home configuration changes in the pending CFS database.

                  switch# show callhome pending-diff

                  Displays the differences between the pending and running Call Home configuration.

                  switch# show callhome session

                  Displays the status of the last Call Home CFS command.

                  switch# show callhome status

                  Displays the Call Home status.

                  switch# show callhome transport-email

                  Displays the e-mail configuration for Call Home.

                  switch# show callhome user-def-cmds

                  Displays CLI commands added to any alert groups.

                  switch# show running-config [callhome | callhome-all]

                  Displays the running configuration for Call Home.

                  switch# show startup-config callhome

                  Displays the startup configuration for Call Home.

                  switch# show tech-support callhome

                  Displays the technical support output for Call Home.

                  Default Call Home Settings

                  The following table lists the default settings for Call Home parameters.

                  Table 3  Default Call Home Parameters

                  Parameters

                  Default

                  Destination message size for a message sent in full text format.

                  4000000

                  Destination message size for a message sent in XML format.

                  4000000

                  Destination message size for a message sent in short text format.

                  4000

                  SMTP server port number if no port is specified.

                  25

                  Alert group association with profile.

                  All for full-text-destination and short-text-destination profiles. The cisco-tac alert group for the CiscoTAC-1 destination profile.

                  Format type.

                  XML

                  Call Home message level.

                  0 (zero)

                  Additional References

                  Call Home Message Formats

                  Call Home supports the following message formats:

                  • Short Text Message Format

                  • Common Fields for All Full Text and XML Messages

                  • Inserted Fields for a Reactive or Proactive Event Message

                  • Inserted Fields for an Inventory Event Message

                  • Inserted Fields for a User-Generated Test Message

                  The following table describes the short text formatting option for all message types.

                  Table 4 Short Text Message Format

                  Data Item

                  Description

                  Device identification

                  Configured device name

                  Date/time stamp

                  Time stamp of the triggering event

                  Error isolation message

                  Plain English description of triggering event

                  Alarm urgency level

                  Error level such as that applied to system message

                  The following table describes the common event message format for full text or XML.

                  Table 5  Common Fields for All Full Text and XML Messages

                  Data Item(Plain Text and XML)

                  Description(Plain Text and XML)

                  XML Tag (XML Only)

                  Time stamp

                  Date and time stamp of event in ISO time notation:

                  YYYY-MM-DD HH:MM:SS GMT+HH:MM

                  /aml/header/time

                  Message name

                  Name of message. Specific event names are listed in the preceding table.

                  /aml/header/name

                  Message type

                  Name of message type, such as reactive or proactive.

                  /aml/header/type

                  Message group

                  Name of alert group, such as syslog.

                  /aml/header/group

                  Severity level

                  Severity level of message.

                  /aml/header/level

                  Source ID

                  Product type for routing. Specifically Catalyst 6500.

                  /aml/header/source

                  Device ID

                  Unique device identifier (UDI) for end device that generated the message. This field should be empty if the message is nonspecific to a device. The format is type@Sid@serial:

                  • type is the product model number from backplane IDPROM.

                  • @ is a separator character.

                  • Sid is C, identifying the serial ID as a chassis serial number.

                  • serial is the number identified by the Sid field.

                  An example is WS-C6509@C@12345678

                  /aml/ header/deviceID

                  Customer ID

                  Optional user-configurable field used for contract information or other ID by any support service.

                  /aml/ header/customerID

                  Contract ID

                  Optional user-configurable field used for contract information or other ID by any support service.

                  /aml/ header /contractID

                  Site ID

                  Optional user-configurable field used for Cisco-supplied site ID or other data meaningful to alternate support service.

                  /aml/ header/siteID

                  Server ID

                  If the message is generated from the device, this is the unique device identifier (UDI) of the device.

                  The format is type@Sid@serial:

                  • type is the product model number from backplane IDPROM.

                  • @ is a separator character.

                  • Sid is C, identifying the serial ID as a chassis serial number.

                  • serial is the number identified by the Sid field.

                  An example is WS-C6509@C@12345678

                  /aml/header/serverID

                  Message description

                  Short text that describes the error.

                  /aml/body/msgDesc

                  Device name

                  Node that experienced the event (host name of the device).

                  /aml/body/sysName

                  Contact name

                  Name of person to contact for issues associated with the node that experienced the event.

                  /aml/body/sysContact

                  Contact e-mail

                  E-mail address of person identified as the contact for this unit.

                  /aml/body/sysContactEmail

                  Contact phone number

                  Phone number of the person identified as the contact for this unit.

                  /aml/body/sysContactPhoneNumber

                  Street address

                  Optional field that contains the street address for RMA part shipments associated with this unit.

                  /aml/body/sysStreetAddress

                  Model name

                  Model name of the device (the specific model as part of a product family name).

                  /aml/body/chassis/name

                  Serial number

                  Chassis serial number of the unit.

                  /aml/body/chassis/serialNo

                  Chassis part number

                  Top assembly number of the chassis.

                  /aml/body/chassis/partNo

                  Fields specific to a particular alert group message are inserted here.

                  The following fields may be repeated if multiple CLI commands are executed for this alert group.

                  Command output name

                  Exact name of the issued CLI command.

                  /aml/attachments/attachment/name

                  Attachment type

                  Specific command output.

                  /aml/attachments/attachment/type

                  MIME type

                  Either plain text or encoding type.

                  /aml/attachments/attachment/mime

                  Command output text

                  Output of command automatically executed.

                  /aml/attachments/attachment/atdata

                  The following table describes the reactive event message format for full text or XML.

                  Table 6  Inserted Fields for a Reactive or Proactive Event Message

                  Data Item(Plain Text and XML)

                  Description(Plain Text and XML)

                  XML Tag (XML Only)

                  Chassis hardware version

                  Hardware version of chassis.

                  /aml/body/chassis/hwVersion

                  Supervisor module software version

                  Top-level software version.

                  /aml/body/chassis/swVersion

                  Affected FRU name

                  Name of the affected FRU that is generating the event message.

                  /aml/body/fru/name

                  Affected FRU serial number

                  Serial number of the affected FRU.

                  /aml/body/fru/serialNo

                  Affected FRU part number

                  Part number of the affected FRU.

                  /aml/body/fru/partNo

                  FRU slot

                  Slot number of the FRU that is generating the event message.

                  /aml/body/fru/slot

                  FRU hardware version

                  Hardware version of the affected FRU.

                  /aml/body/fru/hwVersion

                  FRU software version

                  Software version(s) that is running on the affected FRU.

                  /aml/body/fru/swVersion

                  The following table describes the inventory event message format for full text or XML.

                  Table 7  Inserted Fields for an Inventory Event Message

                  Data Item(Plain Text and XML)

                  Description(Plain Text and XML)

                  XML Tag(XML Only)

                  Chassis hardware version

                  Hardware version of the chassis.

                  /aml/body/chassis/hwVersion

                  Supervisor module software version

                  Top-level software version.

                  /aml/body/chassis/swVersion

                  FRU name

                  Name of the affected FRU that is generating the event message.

                  /aml/body/fru/name

                  FRU s/n

                  Serial number of the FRU.

                  /aml/body/fru/serialNo

                  FRU part number

                  Part number of the FRU.

                  /aml/body/fru/partNo

                  FRU slot

                  Slot number of the FRU.

                  /aml/body/fru/slot

                  FRU hardware version

                  Hardware version of the FRU.

                  /aml/body/fru/hwVersion

                  FRU software version

                  Software version(s) that is running on the FRU.

                  /aml/body/fru/swVersion

                  The following table describes the user-generated test message format for full text or XML.

                  Table 8  Inserted Fields for a User-Generated Test Message

                  Data Item(Plain Text and XML)

                  Description(Plain Text and XML)

                  XML Tag(XML Only)

                  Process ID

                  Unique process ID.

                  /aml/body/process/id

                  Process state

                  State of process (for example, running or halted).

                  /aml/body/process/processState

                  Process exception

                  Exception or reason code.

                  /aml/body/process/exception

                  Sample syslog Alert Notification in Full-Text Format

                  This sample shows the full-text format for a syslog port alert-group notification:

                  source:MDS9000
                  Switch Priority:7
                  Device Id:WS-C6509@C@FG@07120011
                  Customer Id:Example.com
                  Contract Id:123
                  Site Id:San Jose
                  Server Id:WS-C6509@C@FG@07120011
                  Time of Event:2004-10-08T11:10:44
                  Message Name:SYSLOG_ALERT
                  Message Type:Syslog
                  Severity Level:2
                  System Name:10.76.100.177
                  Contact Name:User Name
                  Contact Email:person@example.com
                  Contact Phone:+1-408-555-1212
                  Street Address:#1234 Any Street, Any City, Any State, 12345
                  Event Description:2006 Oct  8 11:10:44 10.76.100.177 %PORT-5-IF_TRUNK_UP: %$VLAN 1%$ Interface e2/5, vlan 1 is up
                   
                  syslog_facility:PORT
                  start chassis information:
                  Affected Chassis:WS-C6509
                  Affected Chassis Serial Number:FG@07120011
                  Affected Chassis Hardware Version:0.104
                  Affected Chassis Software Version:3.1(1)
                  Affected Chassis Part No:73-8607-01
                  end chassis information:
                   

                  Sample syslog Alert Notification in XML Format

                  This sample shows the XML format for a syslog port alert-group notification:

                  From: example
                  Sent: Wednesday, April 25, 2007 7:20 AM
                  To: User (user)
                  Subject: System Notification From Router - syslog - 2007-04-25 14:19:55
                  GMT+00:00
                   
                  <?xml version="1.0" encoding="UTF-8"?>
                  <soap-env:Envelope xmlns:soap-env="http://www.w3.org/2003/05/soap-envelope">
                  <soap-env:Header>
                  <aml-session:Session xmlns:aml-session="http://www.example.com/2004/01/aml-session" soap-env:mustUnderstand="true" soap-env:role="http://www.w3.org/2003/05/soap-envelope/role/next">
                  <aml-session:To>http://tools.example.com/services/DDCEService</aml-session:To>
                  <aml-session:Path>
                  <aml-session:Via>http://www.example.com/appliance/uri</aml-session:Via>
                  </aml-session:Path>
                  <aml-session:From>http://www.example.com/appliance/uri</aml-session:From>
                  <aml-session:MessageId>M2:69000101:C9D9E20B</aml-session:MessageId>
                  </aml-session:Session>
                  </soap-env:Header>
                  <soap-env:Body>
                  <aml-block:Block xmlns:aml-block="http://www.example.com/2004/01/aml-block">
                  <aml-block:Header>
                  <aml-block:Type>http://www.example.com/2005/05/callhome/syslog</aml-block:Type>
                  <aml-block:CreationDate>2007-04-25 14:19:55 GMT+00:00</aml-block:CreationDate>
                  <aml-block:Builder>
                  <aml-block:Name>Cat6500</aml-block:Name>
                  <aml-block:Version>2.0</aml-block:Version>
                  </aml-block:Builder>
                  <aml-block:BlockGroup>
                  <aml-block:GroupId>G3:69000101:C9F9E20C</aml-block:GroupId>
                  <aml-block:Number>0</aml-block:Number>
                  <aml-block:IsLast>true</aml-block:IsLast>
                  <aml-block:IsPrimary>true</aml-block:IsPrimary>
                  <aml-block:WaitForPrimary>false</aml-block:WaitForPrimary>
                  </aml-block:BlockGroup>
                  <aml-block:Severity>2</aml-block:Severity>
                  </aml-block:Header>
                  <aml-block:Content>
                  <ch:Call Home xmlns:ch="http://www.example.com/2005/05/callhome" version="1.0">
                  <ch:EventTime>2007-04-25 14:19:55 GMT+00:00</ch:EventTime>
                  <ch:MessageDescription>03:29:29: %CLEAR-5-COUNTERS: Clear counter on all interfaces by console</ch:MessageDescription>
                  <ch:Event>
                  <ch:Type>syslog</ch:Type>
                  <ch:SubType></ch:SubType>
                  <ch:Brand>Cisco Systems</ch:Brand>
                  <ch:Series>Catalyst 6500 Series Switches</ch:Series>
                  </ch:Event>
                  <ch:CustomerData>
                  <ch:UserData>
                  <ch:Email>person@example.com</ch:Email>
                  </ch:UserData>
                  <ch:ContractData>
                  <ch:CustomerId>12345</ch:CustomerId>
                  <ch:SiteId>building 1</ch:SiteId>
                  <ch:ContractId>abcdefg12345</ch:ContractId>
                  <ch:DeviceId>WS-C6509@C@69000101</ch:DeviceId>
                  </ch:ContractData>
                  <ch:SystemInfo>
                  <ch:Name>Router</ch:Name>
                  <ch:Contact></ch:Contact>
                  <ch:ContactEmail>user@example.com</ch:ContactEmail>
                  <ch:ContactPhoneNumber>+1-408-555-1212</ch:ContactPhoneNumber>
                  <ch:StreetAddress>#1234 Any Street, Any City, Any State, 12345</ch:StreetAddress>
                  </ch:SystemInfo>
                  </ch:CustomerData>
                  <ch:Device>
                  <rme:Chassis xmlns:rme="http://www.example.com/rme/4.0">
                  <rme:Model>WS-C6509</rme:Model>
                  <rme:HardwareVersion>1.0</rme:HardwareVersion>
                  <rme:SerialNumber>69000101</rme:SerialNumber>
                  <rme:AdditionalInformation>
                  <rme:AD name="PartNumber" value="73-3438-03 01" />
                  <rme:AD name="SoftwareVersion" value="4.0(20080421:012711)" />
                  </rme:AdditionalInformation>
                  </rme:Chassis>
                  </ch:Device>
                  </ch:Call Home>
                  </aml-block:Content>
                  <aml-block:Attachments>
                  <aml-block:Attachment type="inline">
                  <aml-block:Name>show logging</aml-block:Name>
                  <aml-block:Data encoding="plain">
                  <![CDATA[
                  Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
                      Console logging: level debugging, 53 messages logged, xml disabled,
                                       filtering disabled
                      Monitor logging: level debugging, 0 messages logged, xml disabled,
                                       filtering disabled
                      Buffer logging: level debugging, 53 messages logged, xml disabled,
                                      filtering disabled
                      Exception Logging: size (4096 bytes)
                      Count and timestamp logging messages: disabled
                      Trap logging: level informational, 72 message lines logged
                   
                  Log Buffer (8192 bytes):
                   
                  00:00:54: curr is 0x20000
                   
                  00:00:54: RP: Currently running ROMMON from F2 region
                  00:01:05: %SYS-5-CONFIG_I: Configured from memory by console
                  00:01:09: %SYS-5-RESTART: System restarted --
                  Cisco IOS Software, s72033_rp Software (s72033_rp-ADVENTERPRISEK9_DBG-VM), Experimental Version 12.2(20070421:012711) 
                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-07 15:54 by xxx
                   
                  Firmware compiled 11-Apr-07 03:34 by integ Build [100]
                   
                   
                  00:01:01: %PFREDUN-6-ACTIVE: Initializing as ACTIVE processor for this switch
                  00:01:01: %SYS-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output.
                  00:03:00: SP: SP: Currently running ROMMON from F1 region
                  00:03:07: %C6K_PLATFORM-SP-4-CONFREG_BREAK_ENABLED: The default factory setting for config register is 0x2102.It is advisable to retain 1 in 0x2102 as it prevents returning to ROMMON when break is issued.
                   
                  00:03:18: %SYS-SP-5-RESTART: System restarted --
                  Cisco IOS Software, s72033_sp Software (s72033_sp-ADVENTERPRISEK9_DBG-VM), Experimental Version 12.2(20070421:012711) 
                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-07 18:00 by xxx
                  00:03:18: %SYS-SP-6-BOOTTIME: Time taken to reboot after reload =  339 seconds
                  00:03:18: %OIR-SP-6-INSPS: Power supply inserted in slot 1
                  00:03:18: %C6KPWR-SP-4-PSOK: power supply 1 turned on.
                  00:03:18: %OIR-SP-6-INSPS: Power supply inserted in slot 2
                  00:01:09: %SSH-5-ENABLED: SSH 1.99 has been enabled
                  00:03:18: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
                  00:03:18: %C6KPWR-SP-4-PSREDUNDANTMISMATCH: power supplies rated outputs do not match.
                  00:03:18: %C6KPWR-SP-4-PSREDUNDANTBOTHSUPPLY: in power-redundancy mode, system is operating on both power supplies.
                  00:01:10: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
                  00:01:10: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
                  00:03:20: %C6KENV-SP-4-FANHIOUTPUT: Version 2 high-output fan-tray is in effect
                  00:03:22: %C6KPWR-SP-4-PSNOREDUNDANCY: Power supplies are not in full redundancy, power usage exceeds lower capacity supply
                  00:03:26: %FABRIC-SP-5-FABRIC_MODULE_ACTIVE: The Switch Fabric Module in slot 6 became active.
                  00:03:28: %DIAG-SP-6-RUN_MINIMUM: Module 6: Running Minimal Diagnostics...
                  00:03:50: %DIAG-SP-6-DIAG_OK: Module 6: Passed Online Diagnostics
                  00:03:50: %OIR-SP-6-INSCARD: Card inserted in slot 6, interfaces are now online
                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 3: Running Minimal Diagnostics...
                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 7: Running Minimal Diagnostics...
                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimal Diagnostics...
                  00:01:51: %MFIB_CONST_RP-6-REPLICATION_MODE_CHANGE: Replication Mode Change Detected. Current system replication mode is Ingress
                  00:04:01: %DIAG-SP-6-DIAG_OK: Module 3: Passed Online Diagnostics
                  00:04:01: %OIR-SP-6-DOWNGRADE: Fabric capable module 3 not at an appropriate hardware revision level, and can only run in flowthrough mode
                  00:04:02: %OIR-SP-6-INSCARD: Card inserted in slot 3, interfaces are now online
                  00:04:11: %DIAG-SP-6-DIAG_OK: Module 7: Passed Online Diagnostics
                  00:04:14: %OIR-SP-6-INSCARD: Card inserted in slot 7, interfaces are now online
                  00:04:35: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
                  00:04:37: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
                  00:00:09: DaughterBoard (Distributed Forwarding Card 3)
                   
                  Firmware compiled 11-Apr-07 03:34 by integ Build [100]
                   
                   
                  00:00:22: %SYS-DFC4-5-RESTART: System restarted --
                  Cisco DCOS Software, c6lc2 Software (c6lc2-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-08 17:20 by xxx
                  00:00:23: DFC4: Currently running ROMMON from F2 region
                  00:00:25: %SYS-DFC2-5-RESTART: System restarted --
                  Cisco IOS Software, c6slc Software (c6slc-SPDBG-VM), Experimental Version 12.2(20070421:012711) 
                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-08 16:40 by username1
                  00:00:26: DFC2: Currently running ROMMON from F2 region
                  00:04:56: %DIAG-SP-6-RUN_MINIMUM: Module 4: Running Minimal Diagnostics...
                  00:00:09: DaughterBoard (Distributed Forwarding Card 3)
                   
                  Firmware compiled 11-Apr-08 03:34 by integ Build [100]
                   
                  slot_id is 8
                   
                  00:00:31: %FLASHFS_HES-DFC8-3-BADCARD: /bootflash:: The flash card seems to be corrupted
                  00:00:31: %SYS-DFC8-5-RESTART: System restarted --
                  Cisco DCOS Software, c6lc2 Software (c6lc2-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-08 17:20 by username1
                  00:00:31: DFC8: Currently running ROMMON from S (Gold) region
                  00:04:59: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimal Diagnostics...
                  00:05:12: %DIAG-SP-6-RUN_MINIMUM: Module 8: Running Minimal Diagnostics...
                  00:05:13: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimal Diagnostics...
                  00:00:24: %SYS-DFC1-5-RESTART: System restarted --
                  Cisco DCOS Software, c6slc Software (c6slc-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                  Compiled Thu 26-Apr-08 16:40 by username1
                  00:00:25: DFC1: Currently running ROMMON from F2 region
                  00:05:30: %DIAG-SP-6-DIAG_OK: Module 4: Passed Online Diagnostics
                  00:05:31: %SPAN-SP-6-SPAN_EGRESS_REPLICATION_MODE_CHANGE: Span Egress HW Replication Mode Change Detected. Current replication mode for unused asic session 0 is Centralized
                  00:05:31: %SPAN-SP-6-SPAN_EGRESS_REPLICATION_MODE_CHANGE: Span Egress HW Replication Mode Change Detected. Current replication mode for unused asic session 1 is Centralized
                  00:05:31: %OIR-SP-6-INSCARD: Card inserted in slot 4, interfaces are now online
                  00:06:02: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
                  00:06:03: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
                  00:06:31: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics
                  00:06:33: %OIR-SP-6-INSCARD: Card inserted in slot 2, interfaces are now online
                  00:04:30: %XDR-6-XDRIPCNOTIFY: Message not sent to slot 4/0 (4) because of IPC error timeout. Disabling linecard. (Expected during linecard OIR)
                  00:06:59: %DIAG-SP-6-DIAG_OK: Module 8: Passed Online Diagnostics
                  00:06:59: %OIR-SP-6-DOWNGRADE_EARL: Module 8 DFC installed is not identical to system PFC and will perform at current system operating mode.
                  00:07:06: %OIR-SP-6-INSCARD: Card inserted in slot 8, interfaces are now online
                   
                  Router#]]></aml-block:Data>
                  </aml-block:Attachment>
                  </aml-block:Attachments>
                  </aml-block:Block>
                  </soap-env:Body>
                  </soap-env:Envelope>
                   

                  Configuring Smart Call Home

                  Contents

                  Configuring Smart Call Home

                  This chapter contains the following sections:

                  Configuring Smart Call Home

                  Information About Call Home

                  Call Home provides e-mail-based notification of critical system events. Cisco Nexus 5000 Series switches provide a range of message formats for optimal compatibility with pager services, standard e-mail, or XML-based automated parsing applications. You can use this feature to page a network support engineer, e-mail a Network Operations Center, or use Cisco Smart Call Home services to automatically generate a case with the Technical Assistance Center.

                  Call Home Overview

                  You can use Call Home to notify an external entity when an important event occurs on your device. Call Home delivers alerts to multiple recipients that you configure in destination profiles.

                  Call Home includes a fixed set of predefined alerts on your switch. These alerts are grouped into alert groups and CLI commands to are assigned to execute when an alert in an alert group occurs. The switch includes the command output in the transmitted Call Home message.

                  The Call Home feature offers the following advantages:

                  • Automatic execution and attachment of relevant CLI command output.

                  • Multiple message format options such as the following:

                    • Short Text—Suitable for pagers or printed reports.

                    • Full Text—Fully formatted message information suitable for human reading.

                    • XML—Matching readable format that uses the Extensible Markup Language (XML) and the Adaptive Messaging Language (AML) XML schema definition (XSD). The XML format enables communication with the Cisco Systems Technical Assistance Center (Cisco-TAC).

                  • Multiple concurrent message destinations. You can configure up to 50 e-mail destination addresses for each destination profile.

                  Destination Profiles

                  A destination profile includes the following information:

                  • One or more alert groups—The group of alerts that trigger a specific Call Home message if the alert occurs.

                  • One or more e-mail destinations—The list of receipents for the Call Home messages generated by alert groups assigned to this destination profile.

                  • Message format—The format for the Call Home message (short text, full text, or XML).

                  • Message severity level—The Call Home severity level that the alert must meet before the switch generates a Call Home message to all e-mail addresses in the destination profile. The Cisco Nexus 5000 Series switch does not generate an alert if the Call Home severity level of the alert is lower than the message severity level set for the destination profile.

                  You can also configure a destination profile to allow periodic inventory update messages by using the inventory alert group that will send out periodic messages daily, weekly, or monthly.

                  Cisco Nexus 5000 Series switches support the following predefined destination profiles:

                  • CiscoTAC-1—Supports the Cisco-TAC alert group in XML message format.

                  • full-text-destination—Supports the full text message format.

                  • short-text-destination—Supports the short text message format.

                  Call Home Alert Groups

                  An alert group is a predefined subset of Call Home alerts that are supported in all Cisco Nexus 5000 Series switches. Alert groups allow you to select the set of Call Home alerts that you want to send to a predefined or custom destination profile. The switch sends Call Home alerts to e-mail destinations in a destination profile only if that Call Home alert belongs to one of the alert groups associated with that destination profile and if the alert has a Call Home message severity at or above the message severity set in the destination profile.

                  The following table lists supported alert groups and the default CLI command output included in Call Home messages generated for the alert group.

                  Table 1  Alert Groups and Executed Commands

                  Alert Group

                  Description

                  Executed Commands

                  Cisco-TAC

                  All critical alerts from the other alert groups destined for Smart Call Home.

                  Execute commands based on the alert group that originates the alert.

                  Diagnostic

                  Events generated by diagnostics.

                  show diagnostic result module all detail

                  show moduleshow version

                  show tech-support platform callhome

                  Supervisor hardware

                  Events related to supervisor modules.

                  show diagnostic result module all detail

                  show moduleshow version

                  show tech-support platform callhome

                  Linecard hardware

                  Events related to standard or intelligent switching modules.

                  show diagnostic result module all detail

                  show moduleshow version

                  show tech-support platform callhome

                  Configuration

                  Periodic events related to configuration.

                  show version

                  show module

                  show running-config all

                  show startup-config

                  System

                  Events generated by failure of a software system that is critical to unit operation.

                  show system redundancy status

                  show tech-support

                  Environmental

                  Events related to power, fan, and environment-sensing elements such as temperature alarms.

                  show environment

                  show logging last 1000

                  show module show version

                  show tech-support platform callhome

                  Inventory

                  Inventory status that is provided whenever a unit is cold booted, or when FRUs are inserted or removed. This alert is considered a noncritical event, and the information is used for status and entitlement.

                  show module

                  show version

                  show license usage

                  show inventory

                  show sprom all

                  show system uptime

                  Call Home maps the syslog severity level to the corresponding Call Home severity level for syslog port group messages

                  You can customize predefined alert groups to execute additional CLI show commands when specific events occur and send that show output with the Call Home message.

                  You can add show commands only to full text and XML destination profiles. Short text destination profiles do not support additional show commands because they only allow 128 bytes of text.

                  Related Information

                  Call Home Message Levels

                  Call Home allows you to filter messages based on their level of urgency. You can associate each destination profile (predefined and user defined) with a Call Home message level threshold. The switch does not generate any Call Home messages with a value lower than this threshold for the destination profile. The Call Home message level ranges from 0 (lowest level of urgency) to 9 (highest level of urgency), and the default is 0 ( Cisco Nexus 5000 Series sends all messages).

                  Call Home messages that are sent for syslog alert groups have the syslog severity level mapped to the Call Home message level.


                  Note


                  Call Home does not change the syslog message level in the message text.


                  The following table lists each Call Home message level keyword and the corresponding syslog level for the syslog port alert group.

                  Table 2  Severity and syslog Level Mapping

                  Call Home Level

                  Keyword

                  syslog Level

                  Description

                  9

                  Catastrophic

                  N/A

                  Network-wide catastrophic failure.

                  8

                  Disaster

                  N/A

                  Significant network impact.

                  7

                  Fatal

                  Emergency (0)

                  System is unusable.

                  6

                  Critical

                  Alert (1)

                  Critical conditions that indicate that immediate attention is needed.

                  5

                  Major

                  Critical (2)

                  Major conditions.

                  4

                  Minor

                  Error (3)

                  Minor conditions.

                  3

                  Warning

                  Warning (4)

                  Warning conditions.

                  2

                  Notification

                  Notice (5)

                  Basic notification and informational messages. Possibly independently insignificant.

                  1

                  Normal

                  Information (6)

                  Normal event signifying return to normal state.

                  0

                  Debugging

                  Debug (7)

                  Debugging messages.

                  Obtaining Smart Call Home

                  If you have a service contract directly with Cisco Systems, you can register your devices for the Smart Call Home service. Smart Call Home provides fast resolution of system problems by analyzing Call Home messages sent from your devices and providing background information and recommendations. For issues that can be identified as known, particularly GOLD diagnostics failures, Automatic Service Requests will be generated with the Cisco-TAC.

                  Smart Call Home offers the following features:

                  • Continuous device health monitoring and real-time diagnostic alerts.

                  • Analysis of Call Home messages from your device and, where appropriate, Automatic Service Request generation, routed to the appropriate TAC team, including detailed diagnostic information to speed problem resolution.

                  • Secure message transport directly from your device or through a downloadable Transport Gateway (TG) aggregation point. You can use a TG aggregation point in cases that require support for multiple devices or in cases where security requirements mandate that your devices may not be connected directly to the Internet.

                  • Web-based access to Call Home messages and recommendations, inventory and configuration information for all Call Home devices. Provides access to associated field notices, security advisories and end-of-life information.

                  You need the following items to register:

                  • The SMARTnet contract number for your switch.

                  • Your e-mail address

                  • Your Cisco.com ID

                  For more information about Smart Call Home, see the Smart Call Home page at this URL: http:/​/​www.cisco.com/​go/​smartcall/​

                  Prerequisites for Call Home

                  Call Home has the following prerequisites:

                  • You must configure an e-mail server.

                  • You must configure the contact name (SNMP server contact), phone, and street address information before you enable Call Home. This step is required to determine the origin of messages received.

                  • Your switch must have IP connectivity to an e-mail server.

                  • If you use Smart Call Home, you need an active service contract for the device that you are configuring.

                  Configuration Guidelines and Limitations

                  Call Home has the following configuration guidelines and limitations:

                  • If there is no IP connectivity or if the interface in the VRF to the profile destination is down, the switch cannot send the Call Home message.

                  • Operates with any SMTP server.

                  Configuring Call Home

                  Procedures for Configuring Call Home

                  SUMMARY STEPS

                    1.    Assign contact information.

                    2.    Configure destination profiles.

                    3.    Associate one or more alert groups to each profile.

                    4.    (Optional) Add additional show commands to the alert groups.

                    5.    Configure transport options.

                    6.    Enable Call Home.

                    7.    (Optional) Test Call Home messages.


                  DETAILED STEPS
                    Step 1   Assign contact information.
                    Step 2   Configure destination profiles.
                    Step 3   Associate one or more alert groups to each profile.
                    Step 4   (Optional)Add additional show commands to the alert groups.
                    Step 5   Configure transport options.
                    Step 6   Enable Call Home.
                    Step 7   (Optional) Test Call Home messages.

                    Configuring Contact Information

                    You must configure the e-mail, phone, and street address information for Call Home. You can optionally configure the contract ID, customer ID, site ID, and switch priority information.

                    SUMMARY STEPS

                      1.    switch# configuration terminal

                      2.    switch(config)# snmp-server contact sys-contact

                      3.    switch(config)# callhome

                      4.    switch(config-callhome)# email-contact email-address

                      5.    switch(config-callhome)# phone-contact international-phone-number

                      6.    switch(config-callhome)# streetaddress address

                      7.    (Optional) switch(config-callhome)# contract-id contract-number

                      8.    (Optional) switch(config-callhome)# customer-id customer-number

                      9.    (Optional) switch(config-callhome)# site-id site-number

                      10.    (Optional) switch(config-callhome)# switch-priority number

                      11.    (Optional) switch# show callhome

                      12.    (Optional) switch# copy running-config startup-config


                    DETAILED STEPS
                       Command or ActionPurpose
                      Step 1 switch# configuration terminal
                       

                      Enters configuration mode.

                       
                      Step 2 switch(config)# snmp-server contact sys-contact
                       

                      Configures the SNMP sysContact.

                       
                      Step 3 switch(config)# callhome
                       

                      Enters callhome configuration mode.

                       
                      Step 4 switch(config-callhome)# email-contact email-address
                       

                      Configures the e-mail address for the primary person responsible for the switch. Up to 255 alphanumeric characters are accepted in e-mail address format.

                      Note   

                      You can use any valid e-mail address. The address cannot contain spaces.

                       
                      Step 5 switch(config-callhome)# phone-contact international-phone-number
                       

                      Configures the phone number in international phone number format for the primary person responsible for the device. Up to 17 alphanumeric characters are accepted in international format.

                      Note   

                      The phone number cannot contain spaces. Be sure to use the + prefix before the number.

                       
                      Step 6 switch(config-callhome)# streetaddress address
                       

                      Configures the street address as an alphanumeric string with white paces for the primary person responsible for the switch. Up to 255 alphanumeric characters are accepted, including spaces.

                       
                      Step 7 switch(config-callhome)# contract-id contract-number
                       
                      (Optional)

                      Configures the contract number for this switch from the service agreement. The contract number can be up to 255 alphanumeric characters in free format.

                       
                      Step 8 switch(config-callhome)# customer-id customer-number
                       
                      (Optional)

                      Configures the customer number for this switch from the service agreement. The customer number can be up to 255 alphanumeric characters in free format.

                       
                      Step 9 switch(config-callhome)# site-id site-number
                       
                      (Optional)

                      Configures the site number for this switch. The site number can be up to 255 alphanumeric characters in free format.

                       
                      Step 10 switch(config-callhome)# switch-priority number
                       
                      (Optional)

                      Configures the switch priority for this switch. The range is from 0 to 7, with 0 being the highest priority and 7 the lowest. The default is 7.

                       
                      Step 11 switch# show callhome
                       
                      (Optional)

                      Displays a summary of the Call Home configuration.

                       
                      Step 12 switch# copy running-config startup-config
                       
                      (Optional)

                      Saves this configuration change.

                       

                      This example shows how to configure the contact information for Call Home:

                      switch# configuration terminal
                      
                      switch(config)# snmp-server contact personname@companyname.com
                      
                      switch(config)# callhome
                      
                      switch(config-callhome)# email-contact personname@companyname.com
                      
                      switch(config-callhome)# phone-contact +1-800-123-4567
                      
                      switch(config-callhome)# street-address 123 Anystreet St., Anycity, Anywhere
                      
                       

                      Creating a Destination Profile

                      You must create a user-defined destination profile and configure the message format for that new destination profile.

                      SUMMARY STEPS

                        1.    switch# configuration terminal

                        2.    switch(config)# callhome

                        3.    switch(config-callhome)# destination-profile {ciscoTAC-1 {alert-group group | email-addr address | http URL | transport-method {email | http}} | profile-name {alert-group group | email-addr address | format {XML | full-txt | short-txt} | http URL | message-level level | message-size size | transport-method {email | http}} | full-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}} | short-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}}}

                        4.    (Optional) switch# show callhome destination-profile [profile name]

                        5.    (Optional) switch# copy running-config startup-config


                      DETAILED STEPS
                         Command or ActionPurpose
                        Step 1 switch# configuration terminal
                         

                        Enters configuration mode.

                         
                        Step 2 switch(config)# callhome
                         

                        Enters callhome configuration mode.

                         
                        Step 3 switch(config-callhome)# destination-profile {ciscoTAC-1 {alert-group group | email-addr address | http URL | transport-method {email | http}} | profile-name {alert-group group | email-addr address | format {XML | full-txt | short-txt} | http URL | message-level level | message-size size | transport-method {email | http}} | full-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}} | short-txt-destination {alert-group group | email-addr address | http URL | message-level level | message-size size | transport-method {email | http}}}
                         

                        Creates a new destination profile and sets the message format for the profile. The profile-name can be any alphanumeric string up to 31 characters.

                        For further details about this command, see the Cisco Nexus 5000 Series Command Reference.

                         
                        Step 4 switch# show callhome destination-profile [profile name]
                         
                        (Optional)

                        Displays information about one or more destination profiles.

                         
                        Step 5 switch# copy running-config startup-config
                         
                        (Optional)

                        Saves this configuration change.

                         

                        This example shows how to create a destination profile for Call Home:

                        switch# configuration terminal
                        switch(config)# callhome
                        switch(config-callhome)# destination-profile Noc101 format full-text
                         

                        Modifying a Destination Profile

                        You can modify the following attributes for a predefined or user-defined destination profile:

                        • Destination address—The actual address, pertinent to the transport mechanism, to which the alert should be sent.

                        • Message formatting—The message format used for sending the alert (full text, short text, or XML).

                        • Message level—The Call Home message severity level for this destination profile.

                        • Message size—The allowed length of a Call Home message sent to the e-mail addresses in this destination profile.


                        Note


                        You cannot modify or delete the CiscoTAC-1 destination profile.


                        SUMMARY STEPS

                          1.    switch# configuration terminal

                          2.    switch(config)# callhome

                          3.    switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} email-addr address

                          4.    destination-profile {name | full-txt-destination | short-txt-destination} message-level number

                          5.    switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} message-size number

                          6.    (Optional) switch# show callhome destination-profile [profile name]

                          7.    (Optional) switch# copy running-config startup-config


                        DETAILED STEPS
                           Command or ActionPurpose
                          Step 1 switch# configuration terminal
                           

                          Enters configuration mode.

                           
                          Step 2 switch(config)# callhome
                           

                          Enters callhome configuration mode.

                           
                          Step 3 switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} email-addr address
                           

                          Configures an e-mail address for a user-defined or predefined destination profile. You can configure up to 50 e-mail addresses in a destination profile.

                           
                          Step 4 destination-profile {name | full-txt-destination | short-txt-destination} message-level number
                           

                          Configures the Call Home message severity level for this destination profile. The switch sends only alerts that have a matching or higher Call Home severity level to destinations in this profile. The range is from 0 to 9, where 9 is the highest severity level.

                           
                          Step 5 switch(config-callhome)# destination-profile {name | full-txt-destination | short-txt-destination} message-size number
                           

                          Configures the maximum message size for this destination profile. The range is from 0 to 5000000 for full-txt-destination and the default is 2500000; from 0 to 100000 for short-txt-destination and the default is 4000; 5000000 for CiscoTAC-1, which is not changeable.

                           
                          Step 6 switch# show callhome destination-profile [profile name]
                           
                          (Optional)

                          Displays information about one or more destination profiles.

                           
                          Step 7 switch# copy running-config startup-config
                           
                          (Optional)

                          Saves this configuration change.

                           

                          This example shows how to modify a destination profile for Call Home:

                          switch# configuration terminal
                          switch(config)# callhome
                          switch(config-callhome)# destination-profile full-text-destination email-addr person@example.com
                          switch(config-callhome)# destination-profile full-text-destination message-level 5
                          switch(config-callhome)# destination-profile full-text-destination message-size 10000
                           

                          Associating an Alert Group with a Destination Profile

                          To associate one or more alert groups with a destination profile, perform this task:

                          SUMMARY STEPS

                            1.    switch# configuration terminal

                            2.    switch(config)# callhome

                            3.    switch(config-callhome)# destination-profile name alert-group {All | Cisco-TAC | Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test}

                            4.    (Optional) switch# show callhome destination-profile [profile name]

                            5.    (Optional) switch# copy running-config startup-config


                          DETAILED STEPS
                             Command or ActionPurpose
                            Step 1 switch# configuration terminal
                             

                            Enters configuration mode.

                             
                            Step 2 switch(config)# callhome
                             

                            Enters callhome configuration mode.

                             
                            Step 3 switch(config-callhome)# destination-profile name alert-group {All | Cisco-TAC | Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test}
                             

                            Associates an alert group with this destination profile. Use the All keyword to associate all alert groups with the destination profile.

                             
                            Step 4 switch# show callhome destination-profile [profile name]
                             
                            (Optional)

                            Displays information about one or more destination profiles.

                             
                            Step 5 switch# copy running-config startup-config
                             
                            (Optional)

                            Saves this configuration change.

                             

                            This example shows how to associate all alert groups with the destination profile Noc101:

                            switch# configuration terminal
                            
                            switch(config)# callhome
                            
                            switch(config-callhome)# destination-profile Noc101 alert-group All
                            
                             

                            Adding show Commands to an Alert Group

                            You can assign a maximum of five user-defined CLI show commands to an alert group.

                            SUMMARY STEPS

                              1.    switch# configuration terminal

                              2.    switch(config)# callhome

                              3.    switch(config-callhome)# alert-group {Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test} user-def-cmd show-cmd

                              4.    (Optional) switch# show callhome user-def-cmds

                              5.    (Optional) switch# copy running-config startup-config


                            DETAILED STEPS
                               Command or ActionPurpose
                              Step 1 switch# configuration terminal
                               

                              Enters configuration mode.

                               
                              Step 2 switch(config)# callhome
                               

                              Enters callhome configuration mode.

                               
                              Step 3 switch(config-callhome)# alert-group {Configuration | Diagnostic | Environmental | Inventory | License | Linecard-Hardware | Supervisor-Hardware | Syslog-group-port | System | Test} user-def-cmd show-cmd
                               

                              Adds the show command output to any Call Home messages sent for this alert group. You must enclose the show command in double quotes. Only valid show commands are accepted.

                              Note   

                              You cannot add user-defined CLI show commands to the CiscoTAC-1 destination profile.

                               
                              Step 4 switch# show callhome user-def-cmds
                               
                              (Optional)

                              Displays information about all user-defined show commands added to alert groups.

                               
                              Step 5 switch# copy running-config startup-config
                               
                              (Optional)

                              Saves this configuration change.

                               

                              This example shows how to add the show ip routing command o the Cisco-TAC alert group:

                              switch# configuration terminal
                              
                              switch(config)# callhome
                              
                              switch(config-callhome)# alert-group Configuration user-def-cmd "show ip routing"
                              
                               

                              Configuring E-Mail

                              You must configure the SMTP server address for the Call Home functionality to work. You can also configure the from and reply-to e-mail addresses.

                              SUMMARY STEPS

                                1.    switch# configuration terminal

                                2.    switch(config)# callhome

                                3.    switch(config-callhome)# transport email smtp-server ip-address [port number] [use-vrf vrf-name]

                                4.    (Optional) switch(config-callhome)# transport email from email-address

                                5.    (Optional) switch(config-callhome)# transport email reply-to email-address

                                6.    (Optional) switch# show callhome transport-email

                                7.    (Optional) switch# copy running-config startup-config


                              DETAILED STEPS
                                 Command or ActionPurpose
                                Step 1 switch# configuration terminal
                                 

                                Enters configuration mode.

                                 
                                Step 2 switch(config)# callhome
                                 

                                Enters callhome configuration mode.

                                 
                                Step 3 switch(config-callhome)# transport email smtp-server ip-address [port number] [use-vrf vrf-name]
                                 

                                Configures the SMTP server as either the domain name server (DNS) name, IPv4 address, or IPv6 address). Optionally you can configure the port number. The port ranges is from 1 to 65535. The default port number is 25.

                                Also optionally you can configure the VRF to use when communicating with this SMTP server.

                                 
                                Step 4 switch(config-callhome)# transport email from email-address
                                 
                                (Optional)

                                Configures the e-mail from field for Call Home messages.

                                 
                                Step 5 switch(config-callhome)# transport email reply-to email-address
                                 
                                (Optional)

                                Configures the e-mail reply-to field for Call Home messages.

                                 
                                Step 6 switch# show callhome transport-email
                                 
                                (Optional)

                                Displays information about the e-mail configuration for Call Home.

                                 
                                Step 7 switch# copy running-config startup-config
                                 
                                (Optional)

                                Saves this configuration change.

                                 

                                This example shows how to configure the e-mail options for Call Home messages:

                                switch# configuration terminal
                                
                                switch(config)# callhome
                                
                                switch(config-callhome)# transport email smtp-server 192.0.2.10 use-vrf Red
                                
                                switch(config-callhome)# transport email from person@example.com
                                
                                switch(config-callhome)# transport email reply-to person@example.com
                                
                                 

                                Configuring Periodic Inventory Notification

                                You can configure the switch to periodically send a message with an inventory of all software services currently enabled and running on the device along with hardware inventory information. The switch generates two Call Home notifications; periodic configuration messages and periodic inventory messages.

                                SUMMARY STEPS

                                  1.    switch# configuration terminal

                                  2.    switch(config)# callhome

                                  3.    switch(config-callhome)# periodic-inventory notification [interval days] [timeofday time]

                                  4.    (Optional) switch# show callhome

                                  5.    (Optional) switch# copy running-config startup-config


                                DETAILED STEPS
                                   Command or ActionPurpose
                                  Step 1 switch# configuration terminal
                                   

                                  Enters configuration mode.

                                   
                                  Step 2 switch(config)# callhome
                                   

                                  Enters callhome configuration mode.

                                   
                                  Step 3 switch(config-callhome)# periodic-inventory notification [interval days] [timeofday time]
                                   

                                  Configures the periodic inventory messages. The interval range is from 1 to 30 days. The default is 7 days. The timeofday value is in HH:MM format.

                                   
                                  Step 4 switch# show callhome
                                   
                                  (Optional)

                                  Displays information about Call Home.

                                   
                                  Step 5 switch# copy running-config startup-config
                                   
                                  (Optional)

                                  Saves this configuration change.

                                   

                                  This example shows how to configure the periodic inventory messages to generate every 20 days:

                                  switch# configuration terminal
                                  
                                  switch(config)# callhome
                                  
                                  switch(config-callhome)# periodic-inventory notification interval 20
                                  
                                   

                                  Disabling Duplicate Message Throttle

                                  You can limit the number of duplicate messages received for the same event. By default, the switch limits the number of duplicate messages received for the same event. If the number of duplicate messages sent exceeds 30 messages within a 2-hour time frame, then the switch discards further messages for that alert type.

                                  Command

                                  Purpose

                                  switch(config-callhome)# no duplicate-message throttle

                                  Disables duplicate message throttling for Call Home. Enabled by default.

                                  Enabling or Disabling Call Home

                                  Once you have configured the contact information, you can enable the Call Home function in callhome configuration mode.

                                  Command

                                  Purpose

                                  switch(config-callhome)# enable

                                  Enables Call Home. Disabled by default.

                                  You can disable Call Home in the callhome configuration mode.

                                  Command

                                  Purpose

                                  switch(config-callhome)# no enable

                                  Disables Call Home. Disabled by default

                                  You can enable Call Home distribution using CFS in the callhome configuration mode.

                                  Command

                                  Purpose

                                  switch(config-callhome)# distribute

                                  Enables Call Home distribution using CFS. Disabled by default.

                                  You can commit Call Home configuration changes and distribute using CFS in the callhome configuration mode.

                                  Command

                                  Purpose

                                  switch(config-callhome)# commit

                                  Commits Call Home configuration changes and distributes the changes to call CFS-enabled devices.

                                  You can discard Call Home configuration changes and release the CFS lock in callhome configuration mode.

                                  Command

                                  Purpose

                                  switch(config-callhome)# abort

                                  Discards Call Home configuration changes and releases the CFS lock. Use this command if you are the CFS lock owner or if you are logged into the device that holds the CFS lock

                                  Testing Call Home Communications

                                  You can generate a test message to test your Call Home communications.

                                  Command

                                  Purpose

                                  switch(config-callhome)# callhome send diagnostic

                                  Sends the specified Call Home test message to all configured destinations.

                                  switch(config-callhome)# callhome test

                                  Sends a test message to all configured destinations.

                                  callhome test and callhome test inventory commands are supported.

                                  Verifying Call Home Configuration

                                  To display Call Home configuration information, perform one of the following tasks:

                                  Command

                                  Purpose

                                  switch# show callhome

                                  Displays the status for Call Home.

                                  switch# show callhome destination-profile name

                                  Displays one or more Call Home destination profiles.

                                  switch# show callhome merge

                                  Displays the status of the last CFS merge for Call Home.

                                  switch# show callhome pending

                                  Displays the Call Home configuration changes in the pending CFS database.

                                  switch# show callhome pending-diff

                                  Displays the differences between the pending and running Call Home configuration.

                                  switch# show callhome session

                                  Displays the status of the last Call Home CFS command.

                                  switch# show callhome status

                                  Displays the Call Home status.

                                  switch# show callhome transport-email

                                  Displays the e-mail configuration for Call Home.

                                  switch# show callhome user-def-cmds

                                  Displays CLI commands added to any alert groups.

                                  switch# show running-config [callhome | callhome-all]

                                  Displays the running configuration for Call Home.

                                  switch# show startup-config callhome

                                  Displays the startup configuration for Call Home.

                                  switch# show tech-support callhome

                                  Displays the technical support output for Call Home.

                                  Default Call Home Settings

                                  The following table lists the default settings for Call Home parameters.

                                  Table 3  Default Call Home Parameters

                                  Parameters

                                  Default

                                  Destination message size for a message sent in full text format.

                                  4000000

                                  Destination message size for a message sent in XML format.

                                  4000000

                                  Destination message size for a message sent in short text format.

                                  4000

                                  SMTP server port number if no port is specified.

                                  25

                                  Alert group association with profile.

                                  All for full-text-destination and short-text-destination profiles. The cisco-tac alert group for the CiscoTAC-1 destination profile.

                                  Format type.

                                  XML

                                  Call Home message level.

                                  0 (zero)

                                  Additional References

                                  Call Home Message Formats

                                  Call Home supports the following message formats:

                                  • Short Text Message Format

                                  • Common Fields for All Full Text and XML Messages

                                  • Inserted Fields for a Reactive or Proactive Event Message

                                  • Inserted Fields for an Inventory Event Message

                                  • Inserted Fields for a User-Generated Test Message

                                  The following table describes the short text formatting option for all message types.

                                  Table 4 Short Text Message Format

                                  Data Item

                                  Description

                                  Device identification

                                  Configured device name

                                  Date/time stamp

                                  Time stamp of the triggering event

                                  Error isolation message

                                  Plain English description of triggering event

                                  Alarm urgency level

                                  Error level such as that applied to system message

                                  The following table describes the common event message format for full text or XML.

                                  Table 5  Common Fields for All Full Text and XML Messages

                                  Data Item(Plain Text and XML)

                                  Description(Plain Text and XML)

                                  XML Tag (XML Only)

                                  Time stamp

                                  Date and time stamp of event in ISO time notation:

                                  YYYY-MM-DD HH:MM:SS GMT+HH:MM

                                  /aml/header/time

                                  Message name

                                  Name of message. Specific event names are listed in the preceding table.

                                  /aml/header/name

                                  Message type

                                  Name of message type, such as reactive or proactive.

                                  /aml/header/type

                                  Message group

                                  Name of alert group, such as syslog.

                                  /aml/header/group

                                  Severity level

                                  Severity level of message.

                                  /aml/header/level

                                  Source ID

                                  Product type for routing. Specifically Catalyst 6500.

                                  /aml/header/source

                                  Device ID

                                  Unique device identifier (UDI) for end device that generated the message. This field should be empty if the message is nonspecific to a device. The format is type@Sid@serial:

                                  • type is the product model number from backplane IDPROM.

                                  • @ is a separator character.

                                  • Sid is C, identifying the serial ID as a chassis serial number.

                                  • serial is the number identified by the Sid field.

                                  An example is WS-C6509@C@12345678

                                  /aml/ header/deviceID

                                  Customer ID

                                  Optional user-configurable field used for contract information or other ID by any support service.

                                  /aml/ header/customerID

                                  Contract ID

                                  Optional user-configurable field used for contract information or other ID by any support service.

                                  /aml/ header /contractID

                                  Site ID

                                  Optional user-configurable field used for Cisco-supplied site ID or other data meaningful to alternate support service.

                                  /aml/ header/siteID

                                  Server ID

                                  If the message is generated from the device, this is the unique device identifier (UDI) of the device.

                                  The format is type@Sid@serial:

                                  • type is the product model number from backplane IDPROM.

                                  • @ is a separator character.

                                  • Sid is C, identifying the serial ID as a chassis serial number.

                                  • serial is the number identified by the Sid field.

                                  An example is WS-C6509@C@12345678

                                  /aml/header/serverID

                                  Message description

                                  Short text that describes the error.

                                  /aml/body/msgDesc

                                  Device name

                                  Node that experienced the event (host name of the device).

                                  /aml/body/sysName

                                  Contact name

                                  Name of person to contact for issues associated with the node that experienced the event.

                                  /aml/body/sysContact

                                  Contact e-mail

                                  E-mail address of person identified as the contact for this unit.

                                  /aml/body/sysContactEmail

                                  Contact phone number

                                  Phone number of the person identified as the contact for this unit.

                                  /aml/body/sysContactPhoneNumber

                                  Street address

                                  Optional field that contains the street address for RMA part shipments associated with this unit.

                                  /aml/body/sysStreetAddress

                                  Model name

                                  Model name of the device (the specific model as part of a product family name).

                                  /aml/body/chassis/name

                                  Serial number

                                  Chassis serial number of the unit.

                                  /aml/body/chassis/serialNo

                                  Chassis part number

                                  Top assembly number of the chassis.

                                  /aml/body/chassis/partNo

                                  Fields specific to a particular alert group message are inserted here.

                                  The following fields may be repeated if multiple CLI commands are executed for this alert group.

                                  Command output name

                                  Exact name of the issued CLI command.

                                  /aml/attachments/attachment/name

                                  Attachment type

                                  Specific command output.

                                  /aml/attachments/attachment/type

                                  MIME type

                                  Either plain text or encoding type.

                                  /aml/attachments/attachment/mime

                                  Command output text

                                  Output of command automatically executed.

                                  /aml/attachments/attachment/atdata

                                  The following table describes the reactive event message format for full text or XML.

                                  Table 6  Inserted Fields for a Reactive or Proactive Event Message

                                  Data Item(Plain Text and XML)

                                  Description(Plain Text and XML)

                                  XML Tag (XML Only)

                                  Chassis hardware version

                                  Hardware version of chassis.

                                  /aml/body/chassis/hwVersion

                                  Supervisor module software version

                                  Top-level software version.

                                  /aml/body/chassis/swVersion

                                  Affected FRU name

                                  Name of the affected FRU that is generating the event message.

                                  /aml/body/fru/name

                                  Affected FRU serial number

                                  Serial number of the affected FRU.

                                  /aml/body/fru/serialNo

                                  Affected FRU part number

                                  Part number of the affected FRU.

                                  /aml/body/fru/partNo

                                  FRU slot

                                  Slot number of the FRU that is generating the event message.

                                  /aml/body/fru/slot

                                  FRU hardware version

                                  Hardware version of the affected FRU.

                                  /aml/body/fru/hwVersion

                                  FRU software version

                                  Software version(s) that is running on the affected FRU.

                                  /aml/body/fru/swVersion

                                  The following table describes the inventory event message format for full text or XML.

                                  Table 7  Inserted Fields for an Inventory Event Message

                                  Data Item(Plain Text and XML)

                                  Description(Plain Text and XML)

                                  XML Tag(XML Only)

                                  Chassis hardware version

                                  Hardware version of the chassis.

                                  /aml/body/chassis/hwVersion

                                  Supervisor module software version

                                  Top-level software version.

                                  /aml/body/chassis/swVersion

                                  FRU name

                                  Name of the affected FRU that is generating the event message.

                                  /aml/body/fru/name

                                  FRU s/n

                                  Serial number of the FRU.

                                  /aml/body/fru/serialNo

                                  FRU part number

                                  Part number of the FRU.

                                  /aml/body/fru/partNo

                                  FRU slot

                                  Slot number of the FRU.

                                  /aml/body/fru/slot

                                  FRU hardware version

                                  Hardware version of the FRU.

                                  /aml/body/fru/hwVersion

                                  FRU software version

                                  Software version(s) that is running on the FRU.

                                  /aml/body/fru/swVersion

                                  The following table describes the user-generated test message format for full text or XML.

                                  Table 8  Inserted Fields for a User-Generated Test Message

                                  Data Item(Plain Text and XML)

                                  Description(Plain Text and XML)

                                  XML Tag(XML Only)

                                  Process ID

                                  Unique process ID.

                                  /aml/body/process/id

                                  Process state

                                  State of process (for example, running or halted).

                                  /aml/body/process/processState

                                  Process exception

                                  Exception or reason code.

                                  /aml/body/process/exception

                                  Sample syslog Alert Notification in Full-Text Format

                                  This sample shows the full-text format for a syslog port alert-group notification:

                                  source:MDS9000
                                  Switch Priority:7
                                  Device Id:WS-C6509@C@FG@07120011
                                  Customer Id:Example.com
                                  Contract Id:123
                                  Site Id:San Jose
                                  Server Id:WS-C6509@C@FG@07120011
                                  Time of Event:2004-10-08T11:10:44
                                  Message Name:SYSLOG_ALERT
                                  Message Type:Syslog
                                  Severity Level:2
                                  System Name:10.76.100.177
                                  Contact Name:User Name
                                  Contact Email:person@example.com
                                  Contact Phone:+1-408-555-1212
                                  Street Address:#1234 Any Street, Any City, Any State, 12345
                                  Event Description:2006 Oct  8 11:10:44 10.76.100.177 %PORT-5-IF_TRUNK_UP: %$VLAN 1%$ Interface e2/5, vlan 1 is up
                                   
                                  syslog_facility:PORT
                                  start chassis information:
                                  Affected Chassis:WS-C6509
                                  Affected Chassis Serial Number:FG@07120011
                                  Affected Chassis Hardware Version:0.104
                                  Affected Chassis Software Version:3.1(1)
                                  Affected Chassis Part No:73-8607-01
                                  end chassis information:
                                   

                                  Sample syslog Alert Notification in XML Format

                                  This sample shows the XML format for a syslog port alert-group notification:

                                  From: example
                                  Sent: Wednesday, April 25, 2007 7:20 AM
                                  To: User (user)
                                  Subject: System Notification From Router - syslog - 2007-04-25 14:19:55
                                  GMT+00:00
                                   
                                  <?xml version="1.0" encoding="UTF-8"?>
                                  <soap-env:Envelope xmlns:soap-env="http://www.w3.org/2003/05/soap-envelope">
                                  <soap-env:Header>
                                  <aml-session:Session xmlns:aml-session="http://www.example.com/2004/01/aml-session" soap-env:mustUnderstand="true" soap-env:role="http://www.w3.org/2003/05/soap-envelope/role/next">
                                  <aml-session:To>http://tools.example.com/services/DDCEService</aml-session:To>
                                  <aml-session:Path>
                                  <aml-session:Via>http://www.example.com/appliance/uri</aml-session:Via>
                                  </aml-session:Path>
                                  <aml-session:From>http://www.example.com/appliance/uri</aml-session:From>
                                  <aml-session:MessageId>M2:69000101:C9D9E20B</aml-session:MessageId>
                                  </aml-session:Session>
                                  </soap-env:Header>
                                  <soap-env:Body>
                                  <aml-block:Block xmlns:aml-block="http://www.example.com/2004/01/aml-block">
                                  <aml-block:Header>
                                  <aml-block:Type>http://www.example.com/2005/05/callhome/syslog</aml-block:Type>
                                  <aml-block:CreationDate>2007-04-25 14:19:55 GMT+00:00</aml-block:CreationDate>
                                  <aml-block:Builder>
                                  <aml-block:Name>Cat6500</aml-block:Name>
                                  <aml-block:Version>2.0</aml-block:Version>
                                  </aml-block:Builder>
                                  <aml-block:BlockGroup>
                                  <aml-block:GroupId>G3:69000101:C9F9E20C</aml-block:GroupId>
                                  <aml-block:Number>0</aml-block:Number>
                                  <aml-block:IsLast>true</aml-block:IsLast>
                                  <aml-block:IsPrimary>true</aml-block:IsPrimary>
                                  <aml-block:WaitForPrimary>false</aml-block:WaitForPrimary>
                                  </aml-block:BlockGroup>
                                  <aml-block:Severity>2</aml-block:Severity>
                                  </aml-block:Header>
                                  <aml-block:Content>
                                  <ch:Call Home xmlns:ch="http://www.example.com/2005/05/callhome" version="1.0">
                                  <ch:EventTime>2007-04-25 14:19:55 GMT+00:00</ch:EventTime>
                                  <ch:MessageDescription>03:29:29: %CLEAR-5-COUNTERS: Clear counter on all interfaces by console</ch:MessageDescription>
                                  <ch:Event>
                                  <ch:Type>syslog</ch:Type>
                                  <ch:SubType></ch:SubType>
                                  <ch:Brand>Cisco Systems</ch:Brand>
                                  <ch:Series>Catalyst 6500 Series Switches</ch:Series>
                                  </ch:Event>
                                  <ch:CustomerData>
                                  <ch:UserData>
                                  <ch:Email>person@example.com</ch:Email>
                                  </ch:UserData>
                                  <ch:ContractData>
                                  <ch:CustomerId>12345</ch:CustomerId>
                                  <ch:SiteId>building 1</ch:SiteId>
                                  <ch:ContractId>abcdefg12345</ch:ContractId>
                                  <ch:DeviceId>WS-C6509@C@69000101</ch:DeviceId>
                                  </ch:ContractData>
                                  <ch:SystemInfo>
                                  <ch:Name>Router</ch:Name>
                                  <ch:Contact></ch:Contact>
                                  <ch:ContactEmail>user@example.com</ch:ContactEmail>
                                  <ch:ContactPhoneNumber>+1-408-555-1212</ch:ContactPhoneNumber>
                                  <ch:StreetAddress>#1234 Any Street, Any City, Any State, 12345</ch:StreetAddress>
                                  </ch:SystemInfo>
                                  </ch:CustomerData>
                                  <ch:Device>
                                  <rme:Chassis xmlns:rme="http://www.example.com/rme/4.0">
                                  <rme:Model>WS-C6509</rme:Model>
                                  <rme:HardwareVersion>1.0</rme:HardwareVersion>
                                  <rme:SerialNumber>69000101</rme:SerialNumber>
                                  <rme:AdditionalInformation>
                                  <rme:AD name="PartNumber" value="73-3438-03 01" />
                                  <rme:AD name="SoftwareVersion" value="4.0(20080421:012711)" />
                                  </rme:AdditionalInformation>
                                  </rme:Chassis>
                                  </ch:Device>
                                  </ch:Call Home>
                                  </aml-block:Content>
                                  <aml-block:Attachments>
                                  <aml-block:Attachment type="inline">
                                  <aml-block:Name>show logging</aml-block:Name>
                                  <aml-block:Data encoding="plain">
                                  <![CDATA[
                                  Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
                                      Console logging: level debugging, 53 messages logged, xml disabled,
                                                       filtering disabled
                                      Monitor logging: level debugging, 0 messages logged, xml disabled,
                                                       filtering disabled
                                      Buffer logging: level debugging, 53 messages logged, xml disabled,
                                                      filtering disabled
                                      Exception Logging: size (4096 bytes)
                                      Count and timestamp logging messages: disabled
                                      Trap logging: level informational, 72 message lines logged
                                   
                                  Log Buffer (8192 bytes):
                                   
                                  00:00:54: curr is 0x20000
                                   
                                  00:00:54: RP: Currently running ROMMON from F2 region
                                  00:01:05: %SYS-5-CONFIG_I: Configured from memory by console
                                  00:01:09: %SYS-5-RESTART: System restarted --
                                  Cisco IOS Software, s72033_rp Software (s72033_rp-ADVENTERPRISEK9_DBG-VM), Experimental Version 12.2(20070421:012711) 
                                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-07 15:54 by xxx
                                   
                                  Firmware compiled 11-Apr-07 03:34 by integ Build [100]
                                   
                                   
                                  00:01:01: %PFREDUN-6-ACTIVE: Initializing as ACTIVE processor for this switch
                                  00:01:01: %SYS-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output.
                                  00:03:00: SP: SP: Currently running ROMMON from F1 region
                                  00:03:07: %C6K_PLATFORM-SP-4-CONFREG_BREAK_ENABLED: The default factory setting for config register is 0x2102.It is advisable to retain 1 in 0x2102 as it prevents returning to ROMMON when break is issued.
                                   
                                  00:03:18: %SYS-SP-5-RESTART: System restarted --
                                  Cisco IOS Software, s72033_sp Software (s72033_sp-ADVENTERPRISEK9_DBG-VM), Experimental Version 12.2(20070421:012711) 
                                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-07 18:00 by xxx
                                  00:03:18: %SYS-SP-6-BOOTTIME: Time taken to reboot after reload =  339 seconds
                                  00:03:18: %OIR-SP-6-INSPS: Power supply inserted in slot 1
                                  00:03:18: %C6KPWR-SP-4-PSOK: power supply 1 turned on.
                                  00:03:18: %OIR-SP-6-INSPS: Power supply inserted in slot 2
                                  00:01:09: %SSH-5-ENABLED: SSH 1.99 has been enabled
                                  00:03:18: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
                                  00:03:18: %C6KPWR-SP-4-PSREDUNDANTMISMATCH: power supplies rated outputs do not match.
                                  00:03:18: %C6KPWR-SP-4-PSREDUNDANTBOTHSUPPLY: in power-redundancy mode, system is operating on both power supplies.
                                  00:01:10: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
                                  00:01:10: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
                                  00:03:20: %C6KENV-SP-4-FANHIOUTPUT: Version 2 high-output fan-tray is in effect
                                  00:03:22: %C6KPWR-SP-4-PSNOREDUNDANCY: Power supplies are not in full redundancy, power usage exceeds lower capacity supply
                                  00:03:26: %FABRIC-SP-5-FABRIC_MODULE_ACTIVE: The Switch Fabric Module in slot 6 became active.
                                  00:03:28: %DIAG-SP-6-RUN_MINIMUM: Module 6: Running Minimal Diagnostics...
                                  00:03:50: %DIAG-SP-6-DIAG_OK: Module 6: Passed Online Diagnostics
                                  00:03:50: %OIR-SP-6-INSCARD: Card inserted in slot 6, interfaces are now online
                                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 3: Running Minimal Diagnostics...
                                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 7: Running Minimal Diagnostics...
                                  00:03:51: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimal Diagnostics...
                                  00:01:51: %MFIB_CONST_RP-6-REPLICATION_MODE_CHANGE: Replication Mode Change Detected. Current system replication mode is Ingress
                                  00:04:01: %DIAG-SP-6-DIAG_OK: Module 3: Passed Online Diagnostics
                                  00:04:01: %OIR-SP-6-DOWNGRADE: Fabric capable module 3 not at an appropriate hardware revision level, and can only run in flowthrough mode
                                  00:04:02: %OIR-SP-6-INSCARD: Card inserted in slot 3, interfaces are now online
                                  00:04:11: %DIAG-SP-6-DIAG_OK: Module 7: Passed Online Diagnostics
                                  00:04:14: %OIR-SP-6-INSCARD: Card inserted in slot 7, interfaces are now online
                                  00:04:35: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
                                  00:04:37: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
                                  00:00:09: DaughterBoard (Distributed Forwarding Card 3)
                                   
                                  Firmware compiled 11-Apr-07 03:34 by integ Build [100]
                                   
                                   
                                  00:00:22: %SYS-DFC4-5-RESTART: System restarted --
                                  Cisco DCOS Software, c6lc2 Software (c6lc2-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-08 17:20 by xxx
                                  00:00:23: DFC4: Currently running ROMMON from F2 region
                                  00:00:25: %SYS-DFC2-5-RESTART: System restarted --
                                  Cisco IOS Software, c6slc Software (c6slc-SPDBG-VM), Experimental Version 12.2(20070421:012711) 
                                  Copyright (c) 1986-2007 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-08 16:40 by username1
                                  00:00:26: DFC2: Currently running ROMMON from F2 region
                                  00:04:56: %DIAG-SP-6-RUN_MINIMUM: Module 4: Running Minimal Diagnostics...
                                  00:00:09: DaughterBoard (Distributed Forwarding Card 3)
                                   
                                  Firmware compiled 11-Apr-08 03:34 by integ Build [100]
                                   
                                  slot_id is 8
                                   
                                  00:00:31: %FLASHFS_HES-DFC8-3-BADCARD: /bootflash:: The flash card seems to be corrupted
                                  00:00:31: %SYS-DFC8-5-RESTART: System restarted --
                                  Cisco DCOS Software, c6lc2 Software (c6lc2-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-08 17:20 by username1
                                  00:00:31: DFC8: Currently running ROMMON from S (Gold) region
                                  00:04:59: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimal Diagnostics...
                                  00:05:12: %DIAG-SP-6-RUN_MINIMUM: Module 8: Running Minimal Diagnostics...
                                  00:05:13: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimal Diagnostics...
                                  00:00:24: %SYS-DFC1-5-RESTART: System restarted --
                                  Cisco DCOS Software, c6slc Software (c6slc-SPDBG-VM), Experimental Version 4.0(20080421:012711) 
                                  Copyright (c) 1986-2008 by Cisco Systems, Inc.
                                  Compiled Thu 26-Apr-08 16:40 by username1
                                  00:00:25: DFC1: Currently running ROMMON from F2 region
                                  00:05:30: %DIAG-SP-6-DIAG_OK: Module 4: Passed Online Diagnostics
                                  00:05:31: %SPAN-SP-6-SPAN_EGRESS_REPLICATION_MODE_CHANGE: Span Egress HW Replication Mode Change Detected. Current replication mode for unused asic session 0 is Centralized
                                  00:05:31: %SPAN-SP-6-SPAN_EGRESS_REPLICATION_MODE_CHANGE: Span Egress HW Replication Mode Change Detected. Current replication mode for unused asic session 1 is Centralized
                                  00:05:31: %OIR-SP-6-INSCARD: Card inserted in slot 4, interfaces are now online
                                  00:06:02: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
                                  00:06:03: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
                                  00:06:31: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics
                                  00:06:33: %OIR-SP-6-INSCARD: Card inserted in slot 2, interfaces are now online
                                  00:04:30: %XDR-6-XDRIPCNOTIFY: Message not sent to slot 4/0 (4) because of IPC error timeout. Disabling linecard. (Expected during linecard OIR)
                                  00:06:59: %DIAG-SP-6-DIAG_OK: Module 8: Passed Online Diagnostics
                                  00:06:59: %OIR-SP-6-DOWNGRADE_EARL: Module 8 DFC installed is not identical to system PFC and will perform at current system operating mode.
                                  00:07:06: %OIR-SP-6-INSCARD: Card inserted in slot 8, interfaces are now online
                                   