You can retrieve and display environmental status reports using these commands:
-
debug
environment
-
debug platform software cman
env monitor polling
-
debug ilpower
-
debug
power [inline |
main]
-
show diag all
eeprom
-
show diag slot R0 eeprom
detail
-
show environment
-
show environment
all
-
show inventory
-
show platform
all
-
show platform
diag
-
show platform software status
control-processor
-
show version
-
show power
-
show power inline
These commands show
the current values of parameters such as temperature and voltage.
The environmental monitoring system updates the values of these parameters every 60 seconds. Brief examples of these commands
are:
debug environment: Example
Router# debug environment location P0
Environmental sensor Temp: Temp 1 P0 debugging is on
Environmental sensor Temp: Temp 2 P0 debugging is on
Environmental sensor Temp: Temp 3 P0 debugging is on
Environmental sensor V: PEM Out P0 debugging is on
Environmental sensor I: PEM In P0 debugging is on
Environmental sensor I: PEM Out P0 debugging is on
Environmental sensor W: In pwr P0 debugging is on
Environmental sensor W: Out pwr P0 debugging is on
Environmental sensor RPM: fan0 P0 debugging is on
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 1 P0, In queue 1
*Jul 8 21:49:23.292 PDT: State=Normal Reading=35
*Jul 8 21:49:23.292 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 1 P0 State=Normal Reading=35
*Jul 8 21:49:23.292 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.292 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 2 P0, In queue 1
*Jul 8 21:49:23.292 PDT: State=Normal Reading=40
*Jul 8 21:49:23.292 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 2 P0 State=Normal Reading=40
*Jul 8 21:49:23.292 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.292 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 3 P0, In queue 1
*Jul 8 21:49:23.292 PDT: State=Normal Reading=44
*Jul 8 21:49:23.292 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.292 PDT: Sensor: Temp: Temp 3 P0 State=Normal Reading=44
*Jul 8 21:49:23.292 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.292 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.292 PDT: Sensor: V: PEM In P0, In queue 1
*Jul 8 21:49:23.292 PDT: State=Normal Reading=118501
*Jul 8 21:49:23.292 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: V: PEM In P0 State=Normal Reading=118501
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: V: PEM Out P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=12000
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: V: PEM Out P0 State=Normal Reading=12000
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: I: PEM In P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=820
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: I: PEM In P0 State=Normal Reading=828
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: I: PEM Out P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=7200
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: I: PEM Out P0 State=Normal Reading=7100
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: P: In pwr P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=97
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: P: In pwr P0 State=Normal Reading=98
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: P: Out pwr P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=87
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: P: Out pwr P0 State=Normal Reading=89
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:23.293 PDT: Sensor: RPM: fan0 P0, In queue 1
*Jul 8 21:49:23.293 PDT: State=Normal Reading=5824
*Jul 8 21:49:23.293 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:23.293 PDT: Sensor: RPM: fan0 P0 State=Normal Reading=5824
*Jul 8 21:49:23.293 PDT: Inserting into queue 1 on spoke 189.
*Jul 8 21:49:23.293 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:43.296 PDT: Sensor: Temp: Temp 1 P0, In queue 1
*Jul 8 21:49:43.296 PDT: State=Normal Reading=35
*Jul 8 21:49:43.296 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:43.296 PDT: Sensor: Temp: Temp 1 P0 State=Normal Reading=35
*Jul 8 21:49:43.296 PDT: Inserting into queue 1 on spoke 209.
*Jul 8 21:49:43.296 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:43.296 PDT: Sensor: Temp: Temp 2 P0, In queue 1
*Jul 8 21:49:43.296 PDT: State=Normal Reading=40
*Jul 8 21:49:43.296 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:49:43.296 PDT: Sensor: Temp: Temp 2 P0 State=Normal Reading=40
*Jul 8 21:49:43.296 PDT: Inserting into queue 1 on spoke 209.
*Jul 8 21:49:43.296 PDT: Rotation count=20 Displacement=0
*Jul 8 21:49:43.296 PDT: Sensor: Temp: Temp 3 P0, In queue 1
*Jul 8 21:49:43.296 PDT: State=Normal Reading=44
*Jul 8 21:49:43.296 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:53:43.329 PDT: State=Normal Reading=5824
*Jul 8 21:53:43.329 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:53:43.329 PDT: Sensor: RPM: fan0 P0 State=Normal Reading=5824
*Jul 8 21:53:43.329 PDT: Inserting into queue 1 on spoke 149.
*Jul 8 21:53:43.329 PDT: Rotation count=20 Displacement=0
debug platform software cman env monitor polling: Example
Router# debug platform software cman env monitor polling
platform software cman env monitor polling debugging is on
Router#
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 1 P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=35
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Temp 1, P0, 35
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 1 P0 State=Normal Reading=35
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 2 P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=40
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Temp 2, P0, 40
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 2 P0 State=Normal Reading=40
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 3 P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=44
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Temp 3, P0, 44
*Jul 8 21:56:23.351 PDT: Sensor: Temp: Temp 3 P0 State=Normal Reading=44
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: V: PEM In P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=118501
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback V: PEM In, P0, 118501
*Jul 8 21:56:23.351 PDT: Sensor: V: PEM In P0 State=Normal Reading=118501
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: V: PEM Out P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=12100
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback V: PEM Out, P0, 12000
*Jul 8 21:56:23.351 PDT: Sensor: V: PEM Out P0 State=Normal Reading=12000
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: I: PEM In P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=820
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback I: PEM In, P0, 828
*Jul 8 21:56:23.351 PDT: Sensor: I: PEM In P0 State=Normal Reading=828
*Jul 8 21:56:23.351 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.351 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.351 PDT: Sensor: I: PEM Out P0, In queue 1
*Jul 8 21:56:23.351 PDT: State=Normal Reading=7200
*Jul 8 21:56:23.351 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.351 PDT: IOS-RP-ENVMON: sensor READ callback I: PEM Out, P0, 7100
*Jul 8 21:56:23.352 PDT: Sensor: I: PEM Out P0 State=Normal Reading=7100
*Jul 8 21:56:23.352 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.352 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.352 PDT: Sensor: P: In pwr P0, In queue 1
*Jul 8 21:56:23.352 PDT: State=Normal Reading=97
*Jul 8 21:56:23.352 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback P: In pwr, P0, 98
*Jul 8 21:56:23.352 PDT: Sensor: P: In pwr P0 State=Normal Reading=98
*Jul 8 21:56:23.352 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.352 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.352 PDT: Sensor: P: Out pwr P0, In queue 1
*Jul 8 21:56:23.352 PDT: State=Normal Reading=88
*Jul 8 21:56:23.352 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback P: Out pwr, P0, 88
*Jul 8 21:56:23.352 PDT: Sensor: P: Out pwr P0 State=Normal Reading=88
*Jul 8 21:56:23.352 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.352 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.352 PDT: Sensor: RPM: fan0 P0, In queue 1
*Jul 8 21:56:23.352 PDT: State=Normal Reading=5888
*Jul 8 21:56:23.352 PDT: Rotation count=0 Poll period=20000
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback RPM: fan0, P0, 5888
*Jul 8 21:56:23.352 PDT: Sensor: RPM: fan0 P0 State=Normal Reading=5888
*Jul 8 21:56:23.352 PDT: Inserting into queue 1 on spoke 9.
*Jul 8 21:56:23.352 PDT: Rotation count=20 Displacement=0
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback RPM: fan0, P2, 12600
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback RPM: fan1, P2, 12840
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback RPM: fan2, P2, 12900
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback P: pwr, P2, 8
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Inlet 1, R0, 29
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Inlet 2, R0, 30
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Outlet 1, R0, 35
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback Temp: Outlet 2, R0, 36
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback Temp: CP-CPU, R0, 42
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 12v, R0, 12127
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 5v, R0, 5022
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 3.3v, R0, 3308
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 3.0v, R0, 3023
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 2.5v, R0, 2490
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.8v, R0, 1798
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.2v, R0, 1203
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.2v_CPU, R0, 1201
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.05v_CPU, R0, 1052
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.05v, R0, 1062
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 1.0v, R0, 1002
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback V: 0.6v, R0, 593
*Jul 8 21:56:23.352 PDT: IOS-RP-ENVMON: sensor READ callback P: pwr, R0, 86
*Jul 8 21:56:25.352 PDT: IOS-RP-ENVMON: sensor READ callback P: pwr: Pwr, 0/1, 5
*Jul 8 21:56:32.354 PDT: IOS-RP-ENVMON: sensor READ callback P: pwr: Pwr, 1/0, 27
debug ilpower: Example
Router# debug ilpower ?
cdp ILPOWER CDP messages
controller ILPOWER controller
event ILPOWER event
ha ILPOWER High-Availability
port ILPOWER port management
powerman ILPOWER powerman
registries ILPOWER registries
scp ILPOWER SCP messages
upoe ILPOWER upoe
debug power [inline|main]: Example
In this example,
there is one 1000W power supply and one 450W power supply. Inline and main
power output is shown.
Router# debug power ?
inline ILPM inline power related
main Main power related
<cr> <cr>
Router# debug power
POWER all debug debugging is on
Router# show debugging | include POWER
POWER:
POWER main debugging is on
POWER inline debugging is on
Router#
..
*Jul 8 21:56:23.351: %ENVIRONMENTAL-6-NOTICE: V: PEM Out, Location: P1, State: Warning, Reading: 0 mV
*Jul 8 21:56:23.351: %IOSXE_PEM-6-PEMOK: The PEM in slot P1 is functioning properly
*Jul 8 21:56:23.351: %PLATFORM_POWER-6-MODEMATCH: Main power is in Boost mode
*Jul 8 21:56:23.351: Power M: Received Msg for 12V/Main, total power 1450, Run same as cfg Yes
*Jul 8 21:56:23.351: Power M: Received Msg for POE/ILPM, total power 500, Run same as cfg No
*Jul 8 21:56:23.351: Power I: Updating pool power is 500 watts
*Jul 8 21:56:23.351: Power I: Intimating modules of total power 500 watts
*Jul 8 21:56:23.351: Power M: Received Msg for 12V/Main, total power 1450, Run same as cfg Yes
*Jul 8 21:56:23.351: Power M: Received Msg for POE/ILPM, total power 500, Run same as cfg No
*Jul 8 21:56:23.351: Power I: Updating pool power is 500 watts
*Jul 8 21:56:23.351: Power I: Intimating modules of total power 500 watts
Router#
show diag all eeprom: Example
Router# show diag all eeprom
MIDPLANE EEPROM data:
Product Identifier (PID) : C8231-G2
Version Identifier (VID) : V00
PCB Serial Number : FOC28500NU4
Hardware Revision : 1.0
CLEI Code : NA
Power/Fan Module P0 EEPROM data:
Product Identifier (PID) : PWR-CC1-115WAC
Version Identifier (VID) : V02
PCB Serial Number :
CLEI Code : IPUPAMFAAB
Power/Fan Module P1 EEPROM data is not initialized
Internal PoE EEPROM data:
Product Identifier (PID) : C82G2-POE-DC-F
Version Identifier (VID) : V01
PCB Serial Number : FOC274202QH
Top Assy. Part Number : 78-0000-00
Hardware Revision : 1.0
CLEI Code : NA
Slot R0 EEPROM data:
Product Identifier (PID) : C8231-G2
Version Identifier (VID) : V00
PCB Serial Number : FOC28500NU4
Hardware Revision : 1.0
CLEI Code : NA
Version Identifier (VID) : V00
Slot F0 EEPROM data:
Product Identifier (PID) : C8231-G2
PCB Serial Number : FOC28500NU4
Hardware Revision : 1.0
CLEI Code : NA
Slot 0 EEPROM data:
Product Identifier (PID) : C8231-G2
Version Identifier (VID) : V00
PCB Serial Number : FOC28500NU4
Hardware Revision : 1.0
CLEI Code : NA
SPA EEPROM data for subslot 0/0:
Product Identifier (PID) : 4x1G-4M-2xSFP+-E
Version Identifier (VID) : V01
PCB Serial Number :
Top Assy. Part Number : 68-2236-01
Top Assy. Revision : A0
Hardware Revision : 2.2
CLEI Code : CNUIAHSAAA
SPA EEPROM data for subslot 0/1 is not available
SPA EEPROM data for subslot 0/2 is not available
SPA EEPROM data for subslot 0/3 is not available
SPA EEPROM data for subslot 0/4 is not available
SPA EEPROM data for subslot 0/5 is not available
SPA EEPROM data for subslot 0/6 is not available
show environment: Example
In this example, note the output for the slots POE0 and POE1.
Router# show environment
Number of Critical alarms: 0
Number of Major alarms: 0
Number of Minor alarms: 0
Slot Sensor Current State Reading Threshold(Minor,Major,Critical,Shutdown)
---------- -------------- --------------- ------------ ---------------------------------------
R0 Temp: Inlet Normal 66 Celsius (68 ,na ,73 ,na )(Celsius)
R0 Temp: Outlet Normal 63 Celsius (68 ,na ,73 ,na )(Celsius)
R0 Temp: CPU Normal 81 Celsius (105,na ,120,na )(Celsius)
R0 V: 12V Normal 11972 mV na
R0 V: 5V Normal 4911 mV na
R0 V: 3.3V_SB Normal 3294 mV na
R0 V: 3.3V Normal 3297 mV na
R0 V: 1.8V Normal 1827 mV na
R0 V: 1.2V Normal 1192 mV na
R0 V: 1.1V_DDR Normal 1099 mV na
R0 V: 1V Normal 994 mV na
R0 V: 0.75V_CORE Normal 738 mV na
R0 V: 0.75V_SYS Normal 862 mV na
R0 V: 0.8V_SW Normal 796 mV na
R0 V: 0.8V Normal 798 mV na
R0 V: 0.75V Normal 749 mV na
R0 I: VP12P0_MB Normal 1939 mA na
R0 P: Power Normal 22 Watts na
show environment all: Example
Router# show environment all
Sensor List: Environmental Monitoring
Sensor Location State Reading
Temp: Temp 1 P0 Normal 36 Celsius
Temp: Temp 2 P0 Normal 38 Celsius
Temp: Temp 3 P0 Normal 38 Celsius
V: PEM In P0 Normal 206502 mV
V: PEM Out P0 Normal 12000 mV
I: PEM In P0 Normal 281 mA
I: PEM Out P0 Normal 3500 mA
P: In pwr P0 Normal 53 Watts
P: Out pwr P0 Normal 43 Watts
RPM: fan0 P0 Normal 3712 RPM
RPM: fan0 P2 Normal 7260 RPM
RPM: fan1 P2 Normal 7260 RPM
RPM: fan2 P2 Normal 7200 RPM
P: pwr P2 Normal 3 Watts
Temp: Inlet 1 R0 Normal 19 Celsius
Temp: Inlet 2 R0 Normal 21 Celsius
Temp: Outlet 1 R0 Normal 25 Celsius
Temp: Outlet 2 R0 Normal 23 Celsius
Temp: CP-CPU R0 Normal 29 Celsius
V: 12v R0 Normal 11984 mV
V: 5v R0 Normal 5018 mV
V: 3.3v R0 Normal 3311 mV
V: 3.0v R0 Normal 2992 mV
V: 2.5v R0 Normal 2488 mV
V: 1.8v R0 Normal 1785 mV
V: 1.2v R0 Normal 1201 mV
V: 1.2v_CPU R0 Normal 1200 mV
V: 1.05v_CPU R0 Normal 1051 mV
V: 1.05v R0 Normal 1058 mV
V: 1.0v R0 Normal 1001 mV
V: 0.6v R0 Normal 595 mV
P: pwr R0 Normal 45 Watts
show inventory: Example
Router# show inventory
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
INFO: Please use "show license UDI" to get serial number for licensing.
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
NAME: "Chassis", DESCR: "Cisco C8231-G2 Chassis"
PID: C8231-G2 , VID: V00 , SN: FGL2903L28C
NAME: "Power Supply Module 0", DESCR: "POE Power Supply for Cisco C8231"
PID: PWR-CC1-115WAC , VID: V02 , SN:
NAME: "POE Module 0", DESCR: "POE Power Supply for Cisco C8231"
PID: PWR-CC1-115WAC , VID: V02 , SN:
NAME: "GE-POE Module", DESCR: "Cisco 8000 POE"
PID: C82G2-POE-DC-F , VID: V01 , SN: FOC274202QH
NAME: "module 0", DESCR: "Cisco C8231-G2 Built-In NIM controller"
PID: C8231-G2 , VID: , SN:
NAME: "NIM subslot 0/0", DESCR: "4x1G-4M-2xSFP+-E"
PID: 4x1G-4M-2xSFP+-E , VID: V01 , SN:
NAME: "subslot 0/0 transceiver 8", DESCR: "SFP+ 10GBASE-SR"
NAME: "subslot 0/0 transceiver 9", DESCR: "SFP+ 10GBASE-SR"
PID: SFP-10G-SR , VID: V03 , SN: JUR2024G6CK
NAME: "module R0", DESCR: "Cisco C8231-G2 Route Processor"
NAME: "module F0", DESCR: "Cisco C8231-G2 Forwarding Processor"
PID: C8231-G2 , VID: , SN:
show platform: Example
Router# show platform
Chassis type: C8231-G2
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 C8231-G2 ok 6d18h
0/0 4x1G-4M-2xSFP+-E ok 6d18h
R0 C8231-G2 ok, active 6d18h
F0 C8231-G2 ok, active 6d18h
P0 PWR-CC1-115WAC ok 6d18h
POE0 PWR-CC1-115WAC ok 6d18h
GE-POE C82G2-POE-DC-F ok 6d18h
Slot CPLD Version Firmware Version
--------- ------------------- ---------------------------------------
0 25071721 17.18(1.5r).s1.cp
R0 25071721 17.18(1.5r).s1.cp
F0 25071721 17.18(1.5r).s1.cp
show platform diag: Example for C8375-E-G2
Router# show platform diag
Chassis type: C8231-G2
Slot: 0, C8231-G2
Running state : ok
Internal state : online
Internal operational state : ok
Physical insert detect time : 00:00:29 (6d18h ago)
Software declared up time : 00:01:09 (6d18h ago)
CPLD version : 25071721
Firmware version : 17.18(1.5r).s1.cp
Sub-slot: 0/0, 4x1G-4M-2xSFP+-E
Operational status : ok
Internal state : inserted
Physical insert detect time : 00:02:29 (6d18h ago)
Logical insert detect time : 00:02:29 (6d18h ago)
Slot: R0, C8231-G2
Running state : ok, active
Internal state : online
Internal operational state : ok
Physical insert detect time : 00:00:29 (6d18h ago)
Software declared up time : 00:00:29 (6d18h ago)
CPLD version : 25071721
Firmware version : 17.18(1.5r).s1.cp
Slot: F0, C8231-G2
Running state : ok, active
Internal state : online
Internal operational state : ok
Physical insert detect time : 00:00:29 (6d18h ago)
Software declared up time : 00:01:05 (6d18h ago)
Hardware ready signal time : 00:01:01 (6d18h ago)
Packet ready signal time : 00:01:19 (6d18h ago)
CPLD version : 25071721
Firmware version : 17.18(1.5r).s1.cp
Slot: P0, PWR-CC1-115WAC
State : ok
Physical insert detect time : 00:00:05 (6d18h ago)
Slot: POE0, PWR-CC1-115WAC
State : ok
Physical insert detect time : 00:00:05 (6d18h ago)
Slot: GE-POE, C82G2-POE-DC-F
State : ok
Physical insert detect time : 00:00:04 (6d18h ago)
show platform software status control-processor: Example
Router# show platform software status control-processor
RP0: online, statistics updated 2 seconds ago
Load Average: healthy
1-Min: 7.70, status: healthy, under 14.30
5-Min: 7.51, status: healthy, under 14.30
15-Min: 7.45, status: healthy, under 14.30
Memory (kb): healthy
Total: 7937336
Used: 4019196 (51%), status: healthy
Free: 3918140 (49%)
Committed: 5455148 (69%), under 90%
Per-core Statistics
CPU0: CPU Utilization (percentage of time spent)
User: 2.69, System: 5.39, Nice: 0.09, Idle: 90.60
IRQ: 0.99, SIRQ: 0.19, IOwait: 0.00
CPU1: CPU Utilization (percentage of time spent)
User: 99.90, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.00, IOwait: 0.00
CPU2: CPU Utilization (percentage of time spent)
User: 99.90, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.00, IOwait: 0.00
CPU3: CPU Utilization (percentage of time spent)
User: 99.90, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.00, IOwait: 0.00
CPU4: CPU Utilization (percentage of time spent)
User: 99.90, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.00, IOwait: 0.00
CPU5: CPU Utilization (percentage of time spent)
User: 99.80, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.10, IOwait: 0.00
CPU6: CPU Utilization (percentage of time spent)
User: 99.80, System: 0.09, Nice: 0.00, Idle: 0.00
IRQ: 0.09, SIRQ: 0.00, IOwait: 0.00
CPU7: CPU Utilization (percentage of time spent)
User: 99.90, System: 0.00, Nice: 0.00, Idle: 0.00
IRQ: 0.10, SIRQ: 0.00, IOwait: 0.00
show diag slot RO eeprom detail: Example
Router# show diag slot R0 eeprom detail
Slot R0 EEPROM data:
EEPROM version : 4
Compatible Type : 0xFF
FRU Specific Info : 0100
PCB Serial Number : FOC28500NU4
Controller Type : 4596
Hardware Revision : 1.0
PCB Part Number : 74-134702-02
Board Revision : 02
Top Assy. Part Number : 68-104678-01
Deviation Number : 0
Fab Version : 02
Product Identifier (PID) : C8231-G2
Version Identifier (VID) : V00
CLEI Code : NA
Chassis Serial Number : FGL2903L28C
Chassis MAC Address : e4a4.1c83.2a80
MAC Address block size : 96
Manufacturing Test Data : 00 00 00 00 00 00 00 00
Asset ID :
show version: Example
Router# show version
Cisco IOS XE Software, Version BLD_V1718_THROTTLE_LATEST_20250613_033405_V17_18_0_46
Cisco IOS Software [IOSXE], c8kg2be Software (ARMV8EL_LINUX_IOSD-UNIVERSALK9-M),
Experimental Version 17.18.20250613:044429 [BLD_V1718_THROTTLE_LATEST_20250613_033405:/nobackup/mcpre/s2c-build-ws 101]
Copyright (c) 1986-2025 by Cisco Systems, Inc.
Compiled Fri 13-Jun-25 04:45 by mcpre
Cisco IOS-XE software, Copyright (c) 2005-2025 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: 17.18(1.5r).s1.cp
arata-ethp3 uptime is 6 days, 19 hours, 6 minutes
Uptime for this control processor is 6 days, 19 hours, 7 minutes
System returned to ROM by Image Install at 23:27:59 UTC Fri Aug 8 2025
System image file is "bootflash:packages.conf"
Last reload reason: Image Install
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
Technology Package License Information:
Controller-managed
The current throughput level is unthrottled
Smart Licensing Status: Smart Licensing Using Policy
cisco C8231-G2 (1RU) processor with 3703220K/6147K bytes of memory.
Processor board ID FGL2903L28C
Router operating mode: Controller-Managed
1 Virtual Ethernet interface
4 Gigabit Ethernet interfaces
4 2.5 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
32768K bytes of non-volatile configuration memory.
8388608K bytes of physical memory.
20249599K bytes of flash memory at bootflash:.
Configuration register is 0x3922