Overview
Use this procedure to replace the standby supervisor module in a dual-supervisor system by copying and booting the Application Centric Infrastructure (ACI) image from a USB drive, and properly configuring the new module to ensure seamless switch operation.
If you ever need to replace the standby supervisor module in a dual-supervisor system, you will need to copy and boot the Application Centric Infrastructure (ACI) image for use with the replacement standby supervisor.
Before you begin
Copy the ACI image to a USB drive.
Procedure
| 1. | Reload the switch. Example:
|
|
| 2. | Enter a break sequence (Ctrl-C or Ctrl-]) during the initial boot sequence to access the loader> prompt. Example:
|
|
| 3. | Plug the USB drive containing the ACI image into the standby supervisor USB slot. |
|
| 4. | Boot the ACI image. Example:
|
|
| 5. | Log in to the switch as an administrator.
|
|
| 6. | Copy the ACI image from the USB drive to the switch. Example:
|