System Specifications

Environmental Specifications

Environment

Specification

Temperature

Ambient operating temperature

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Relative humidity

Operating

5 to 90%

Nonoperating

5 to 95%

Altitude

Operating

0 to 13,123 feet (0 to 4,000 meters)

Environment

Specification

Temperature

Ambient operating temperature

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Humidity

Ambient operating humidity

8 to 80%

Ambient nonoperating

5 to 95%

Ambient operating altitude

0 to 10,000 feet (0 to 3,048 meters)

For China, 6,562 ft (2000 m)

Ambient nonoperating

-1000 to 30,000 feet (-304 to 15,150 meters)

* The Cisco Nexus switch functions in operating temperatures of up to 40°C at sea level. For every 300 meters (1000 ft) above sea level, the maximum temperature is reduced by 1°C. For more details on environmental requirements, see the Cisco Datasheet.

Switch Dimensions

Switch

Width

Depth

Height

Cisco Nexus 9364D-GX2A

17.41 inches (44.23 cm)

29.82 in (75.76 cm)

3.45 inches (8.76 cm) (2 RU)

Switch and Module Weights and Quantities

Component

Weight per Unit

Quantity

Cisco Nexus 9364D-GX2A Chassis (N9K-C9364D-GX2A)

58 lb (26.3 kg)

1

Fan Module

– Port-side intake (burgundy) (NXA-FAN-160CFM2-PI)

1.35 lb (0.61 kg)

4

Power Supply module

– 3000-W AC/HVDC port-side intake (burgundy) (NXA-PAC-3000W-PI)

3.6 lb (1.63 kg)

2 (1 for operations and 1 for redundancy)

Switch Power Input Requirements

This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions.


Note


Some power supplies have capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed here.



Note


If you want to use optics that consume 5W or more power on all the 36 ports, you must install 1100W power supplies.


Switch Typical Power Consumption (AC or DC) Maximum Power Consumption (AC or DC) Heat Dissipation Requirement

Cisco Nexus 9364D-GX2A

1378 W

3000 W

10,236.426 BTUs per hour

Power Specifications

Power specifications include the specifications for each type of power supply module.

3000-W AC Power Supply Specifications

These specifications apply to the PSU3KW-HVPI power supplies.

Property Specification

Power

3000 W

Input Voltage

200-277 VAC

Frequency

50 to 60 Hz

Efficiency

90% or greater (20 to 100% load)

Redundancy Modes

Combined, n+1, and n+n

RoHS Compliance

Yes

Hot Swappable

Yes

Airflow Direction

Port-side intake airflow

3200-W AC/HVDC Power Supply Specifications

Property Specification

Power

3200 W

AC Range

100-120 VAC; 16A Max. 50/60Hz

HVAC Range

200-240 VAC; 16A Max. 50/60Hz

HVDC Range

240 VDC; 14.5 Max.

Input Voltage

264 to 300 VAC

Frequency

47 to 63 Hz

Efficiency

90% or greater (20 to 100% load)

Redundancy Modes

Combined, n+1, and n+n

RoHS Compliance

Yes

Hot Swappable

Yes

3200-W DC/HVDC Power Supply Specifications

Property Specification

Power

3200 W

DC Range

100-120 VDC; 16A Max. 50/60Hz

HVDC Range

240 VDC; 14.5 Max.

Input Voltage

-40 to -72 VDC

Frequency

47 to 63 Hz

Efficiency

90% or greater (20 to 100% load)

Redundancy Modes

Combined, n+1, and n+n

RoHS Compliance

Yes

Hot Swappable

Yes

Power Cable Specifications

These sections show the power cables that you can order and use with this switch.

Power Cables for NXA-PAC-3200W Power Supplies

Cable

Description

CAB-AC-16A-AUS

Power Cord, 16A, 250 VAC, Australia and New Zealand

CAB-AC-16A-CH

Power Cord, 16A, 250 VAC, Peoples Republic of China

CCAB-AC-2500W-EU

Power Cord, 16A, 250 VAC, Continental Europe

CAB-AC-2500W-ISRL

Power Cord, 16A, 250 VAC, Israel

CAB-AC-2500W-US1

Power Cord, 16A, 250 VAC, Japan and North America (nonlocking) 200-240VAC operation

CAB-AC-C6K-TWLK

Power Cord, 16A, 250 VAC, Japan and North America(locking) 200-240VAC operation

CAB-C19-CBN

Power Cord, 16A, 250 VAC, Power distribution unit (PDU)

CAB-ACS-16

Power Cord, 16A, 250 VAC, Switzerland

CAB-AC-C19-TW

Power Cord, 16A, 250 VAC, C19, Taiwan More

CAB-9K16A-BRZ

Power Cord, 16A, 250 VAC, Brazil, Src Plug EL224-C19

PWR-CORD10-IND

Power Cord, IEC60320/ C19, IS16A3,7.0M, India

CAB-IR2073-C19-AR

Power Cord, IRSM 2073 to IEC-C19 14ft Argen

Power Cables for NXA-PDC-3200W Power Supplies

Lug

Part Number

Wire Gauge

Copper lug, 2 hole, size ¼"

Burgundy P/N: YAL2C2T14

Panduit P/N: LCD2-14A-Q

#2AWG

HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches

Part Number

Cord Set Description

Photo

CAB-HVAC-SD-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and SD connectors

277V AC

CAB-HVAC-C14-2M

HVAC

6.6-foot (2.0 m) cable with Saf-D-Grid and C14 (use for up to 240 V) connector

250V AC

CAB-HVAC-RT-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and RT connector

277V AC

NO-POWER-CORD

All except Argentina, Brazil, and Japan

No power cord included with switch

Not applicable

Table 1. HVAC/HVDC Power Cables Callout Table

1

Connect this end to the power supply unit.

HVAC/HVDC Power Cables

Part Number

Cord Set Description

Photo

CAB-HVAC-SD-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and SD connectors

277V AC

CAB-HVAC-C14-2M

HVAC

6.6-foot (2.0 m) cable with Saf-D-Grid and C14 (use for up to 240 V) connector

250V AC

CAB-HVAC-RT-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and RT connector

277V AC

NO-POWER-CORD

All except Argentina, Brazil, and Japan

No power cord included with switch

Not applicable

Table 2. HVAC/HVDC Power Cables Callout Table

1

Connect this end to the power supply unit.

DC Power Cable Specifications

Part ID Number

Description

Photo

NXA-PDC-2KW-PE/PI The 2000W DC power supply (NXA-PDC-2KW-PE/PI) is not shipped with a connector. You must purchase the cable (PWR-2KW-DC-CBL) separately.

Regulatory Standards Compliance Specifications

This table lists the regulatory standards compliance for the switch.

Table 3. Regulatory Standards Compliance: Safety and EMC

Specification

Description

Regulatory compliance

Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC.

Safety

  • CAN/CSA-C22.2 No. 60950-1 Second Edition

  • CAN/CSA-C22.2 No. 62368-1-19 Third Edition

  • ANSI/UL 60950-1 Second edition

  • IEC 62368-1

  • EN 62368-1

  • AS/NZS 62368-1

  • GB4943

  • UL 62368-1

EMC: Emissions

  • 47CFR Part 15 (CFR 47) Class A

  • AS/NZS CISPR22 Class A

  • CISPR22 Class A

  • EN55022 Class A

  • ICES003 Class A

  • VCCI Class A

  • EN61000-3-2

  • EN61000-3-3

  • KN22 Class A

  • CNS13438 Class A

EMC: Immunity

  • EN55024

  • CISPR24

  • EN300386

  • KN 61000-4 series

RoHS

The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors.