Overview

Overview

The Cisco Nexus 9332D-GX2B switch (N9K-C9332D-GX2B) is a 1-rack unit (RU), fixed-port switch designed for deployment in data centers.

This switch includes these ports:

  • 400-Gigabit QSFP-DD ports (32)

  • 10-Gigabit SFP+ ports (2)

  • Management ports (one 10/100/1000BASE-T port and one SFP port)

  • Console port (RS-232)

  • USB port


Note


From ACI release 6.1(2) and later, you can change the role of any undiscovered switch before the switch is discovered using this CLI command:

(none)# acidiag setrole <leaf/spine>

This command will reboot the switch, Proceed? [y/N]



Note


The acidiag setrole <leaf/spine> command will NOT work if the switch has been discovered. You will see an error message.

For more information about using this CLI command, see the Cisco APIC Getting Started Guide, Release 6.1(x).


This switch includes these user-replaceable components:

  • Fan modules (6) with these airflow choices:

    • Port-side exhaust fan module with blue coloring (NXA-SFAN-35CFM-PE)

    • Port-side intake fan module with burgundy coloring (NXA-SFAN-35CFM-PI)

  • Power supply modules (two—One for operations and one for redundancy [1+1]) with these choices:

    • 1500-W port-side intake AC power supply with red coloring (NXA-PAC-1500W-PI)

    • 1500-W port-side exhaust AC power supply with blue coloring (NXA-PAC-1500W-PE)

    • 1100-W port-side intake DC power supply with red coloring (NXA-PDC-1100W-PI)

    Fan information:

  • All fan modules and power supplies must use the same airflow direction.

  • Each fan module has two rotors. The switch can function normally if one rotor inside any one fan module fails. In case of more than one rotor failure, the switch will issue a warning and power down in 2 minutes.

When port-side exhaust power supplies and fans are installed, the ambient temperature should be 28C or lower and the maximum pluggable optics power supported in each of the 32 ports is as specified in the table.

When port-side intake DC power supplies are installed, the total power available for optics is 200W and these limitations apply:

  • When not using high power optics (15W to 20W), then MACsec can be used on 8 ports of the switch.

  • When using 4x high power optics (15W to 20W), then MACsec can be used on 4 ports of the switch.

  • When using 8x high power optics (15W to 20W), then MACsec cannot be used on the switch.

The figure shows the switch features on the port side of the chassis.

1

LEDs

3

400-Gigabit QSFP-DD ports (32)

2

10-Gigabit SFP+ ports (2)

To determine which transceivers, adapters, and cables support this switch, see the Cisco Transceiver Modules Compatibility Information document.

The figure shows the switch features on the power supply side of the chassis.

1

Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (left) and 2 (right)

4

Management port (RJ45)

2

Fan modules (6) with slots numbered from 1 (left) to 6 (right)

5

Management port (SFP)

3

Console port

6

USB port

The figure shows the side of the chassis.

1

Screw holes for mounting brackets

2

Grounding pad

The fan and power supply modules are field replaceable. You can replace one fan module or one power supply module during operations as long as the other modules are installed and operating. If you have only one power supply installed, you can install the replacement power supply in the open slot before removing the original power supply.


Note


All fan and power supply modules must have the same direction of airflow, or the switch can overheat and shut down.



Caution


If the switch has port-side intake airflow (burgundy coloring for fan modules), locate the ports in the cold aisle. If the switch has port-side exhaust airflow (blue coloring for fan modules), locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.


Optics specifications

Use the supported power supplies and fans listed in the table. For power supply and fan remove and install procedures, see Replacing a Fan Module.

Table 1. Optics Specifications

Power Supply

Fan

MACSec Enabled

Ambient Temperature Limit

Optics Power (W) Consumption

NXA-PAC-1500W-PI

NXA-SFAN-35CFM-PI

8 ports

40 °C

Ports 1-32: Max. 12W per port

NXA-PAC-1500W-PI

NXA-SFAN-35CFM-PI

4 ports

40 °C

Ports 1-28: Max. 12W per port

Ports: 29-32: Max. 20W per port

NXA-PAC-1500W-PI

NXA-SFAN-35CFM-PI

0 ports

40 °C

Ports 1-24: Max. 12W per port

Ports: 25-32: Max. 20W per port

NXA-PAC-1500W-PE

NXA-SFAN-35CFM-PE

8

30 °C

Ports 1-32: Max. 12W per port

NXA-PAC-1500W-PE

NXA-SFAN-35CFM-PE

4

30 °C

Ports 1-28: Max. 12W per port

Ports: 29-32: Max. 20W per port

NXA-PAC-1500W-PE

NXA-SFAN-35CFM-PE

0

30 °C

Ports 1-24: Max. 12W per port

Ports: 25-32: Max. 20W per port

NXA-PDC-1100W-PI

NXA-SFAN-35CFM-PI

8

40 °C

Total power available for optics: 200W

Ports 1-32: Max. 12W per port

NXA-PDC-1100W-PI

NXA-SFAN-35CFM-PI

4

40 °C

Total power available for optics: 200W

Ports 1-28: Max. 12W per port

Ports 29-32: Max. 20W per port

NXA-PDC-1100W-PI

NXA-SFAN-35CFM-PI

0

40 °C

Total power available for optics: 200W

Ports 1-24: Max. 12W per port

Ports 25-32: Max. 20W per port