This document describes how to troubleshoot one or more switch interfaces that repeatedly change state between up and down (port flaps or link flaps), which causes intermittent connectivity.
Cisco Catalyst 9000 Series switches with copper or fiber uplinks/downlinks. The issue can occur on access ports, uplinks, and (when present) removable network-module ports. The physical path can include patch panels, endpoint devices, and optical transceivers.
Common causes include bad or unsupported cabling, unsupported or faulty Small Form-Factor Pluggable (SFP) or Small Form-Factor Pluggable Plus (SFP+) transceivers, duplex or negotiation mismatches, endpoint power-save behavior, and other physical-layer faults.
Follow the troubleshooting workflow in this article to confirm the flap in logs, validate physical connectivity and optics, review interface counters, and run copper-only TDR or fiber-only DOM checks as applicable.
There are no specific requirements for this document.
The information in this document is based on Cisco Catalyst 9000 Series switches.
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, ensure that you understand the potential impact of any command.
A port flap, also referred to as a link flap, occurs when a physical interface on the switch repeatedly goes up and down. Common causes include bad, unsupported, or nonstandard cabling, unsupported Small Form-Factor Pluggable (SFP) transceivers, and other link-synchronization issues. The condition can be intermittent or permanent.
Since link flaps tend to be a physical issue, this document describes how to diagnose the problem, collect useful logs, and troubleshoot port flaps on Cisco Catalyst 9000 Series switches.
Use this workflow to isolate the most common causes of port flaps. Start at Step 1 and proceed in order. Run optional steps only when the link type and symptoms match.
Each section includes a short note that indicates when to use it.
Use this section when physical access is available. Verify that network modules, cables, and SFP or SFP+ transceivers are properly installed before reviewing counters or running additional diagnostics.
Use this reference when a removable network module is present. The table describes best practices to install a network module in a Cisco Catalyst 9000 Series switch:
| Platform |
URL |
| Catalyst 9200 Series Switches |
|
| Catalyst 9300 Series Switches |
|
| Catalyst 9400 Series Switches |
|
| Catalyst 9500 Series Switches |
|
| Catalyst 9600 Series Switches |
Use this section after the flap is confirmed in the logs. These tables describe common cable-related causes of link flaps and the recommended recovery actions.
| Cause |
Recovery Action |
| Bad Cable |
Swap the suspect cable with a known-good cable. Look for broken or missing pins on connectors. |
| Loose connection |
Reseat the cable. Remove the connector and reinsert it to ensure it is fully seated. |
| Patch Panels |
Eliminate faulty patch-panel connections. Bypass the patch panel, if possible, to rule it out. |
| Bad or wrong SFP (fiber specific) |
Swap the suspect SFP with a known-good SFP. Verify hardware and software support for this type of SFP. |
| Bad Port or Module Port |
Move the cable to a known-good port to troubleshoot a suspect port or module. |
| Bad or old endpoint device |
Swap the phone, speaker, or other endpoint with a known-good device or a newer device. |
| Device Sleep Mode |
This can be an expected flap. Check the timestamp of the port flap. Compare it to other simultaneous events. Then determine whether a sleep setting is the cause. |
Use this section when the flapping link uses a fiber transceiver. The Cisco portfolio of hot-pluggable interfaces offers a broad set of choices for speeds, protocols, reaches, and supported transmission media.
Use any combination of SFP or SFP+ transceiver modules that the Cisco Catalyst 9000 Series switch supports. Each port must match the wavelength specifications on the other end of the cable. The cable must not exceed the supported cable length for reliable communication.
Use only Cisco SFP transceiver modules on the Cisco device. Each SFP or SFP+ transceiver module supports the Cisco Quality Identification (ID) feature. This feature allows a Cisco switch or router to identify and validate that the transceiver module is certified and tested by Cisco.
Prerequisites: Privileged EXEC access (for example, enable) and access to the device system log buffer or remote syslog.
Expected outcome: Repeated up/down messages for the same interface within a short time window confirm a flap condition.
Use this section first to confirm that a flap is occurring. Run the show logging | include changed command to identify a link flap event. This example shows partial switch system log messages for a link flap event on interface TenGigabitEthernet1/0/40:
Switch#show logging | include changed
August 17 21:06:08.431 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:06:39.058 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:06:41.968 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to up
August 17 21:06:42.969 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to up
August 17 21:07:20.041 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:07:21.041 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:07:36.534 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to up
August 17 21:08:06.598 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to up
August 17 21:08:07.628 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:08:08.628 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to down
August 17 21:08:10.943 UTC: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/40, changed state to up
August 17 21:08:11.944 UTC: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/40, changed state to up
When to use: After repeated up/down events are confirmed and the physical path is validated.
Command: show interfaces and show controllers ethernet-controller interface for the affected interface.
Expected result: Error counters (CRC, symbol errors, FCS) remain stable or increase slowly under normal conditions.
Next action if abnormal: Swap cable/optic, move to a known-good port, and re-check counters; proceed to TDR (copper) or DOM (fiber) as applicable.
Use this section after the flap is confirmed and the physical path is checked. The show interfaces command provides information that helps identify a possible Layer 1 issue that causes a link flap event:
Switch#show interfaces tenGigabitEthernet 1/0/40
TenGigabitEthernet1/0/40 is up, line protocol is up (connected)
Hardware is Ten Gigabit Ethernet, address is 00a5.bf9c.29a8 (bia 00a5.bf9c.29a8)
MTU 1500 bytes, BW 10000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive not set
Full-duplex, 10Gb/s, link type is auto, media type is SFP-10GBase-SR <-- SFP plugged into the port
input flow-control is on, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:03, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
670 packets input, 78317 bytes, 0 no buffer
Received 540 broadcasts (540 multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 540 multicast, 0 pause input
0 input packets with dribble condition detected
1766 packets output, 146082 bytes, 0 underruns
0 Output 0 broadcasts (0 multicasts)
0 output errors, 0 collisions, 0 interface resets
0 unknown protocol drops
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 pause output
0 output buffer failures, 0 output buffers swapped out
The table lists some of the counters from the show interfaces command:
| Counter |
Issues and Common Causes that Increase Error Counters |
| CRC |
A high number of cyclic redundancy check (CRC) errors is usually the result of collisions. It can also indicate a physical issue such as cabling, an SFP, a bad interface, or a network interface card (NIC). It can also indicate a duplex mismatch. |
| Input Errors |
This includes runts, giants, no buffer, CRC, frame, overrun, and ignored counts. Other input-related errors can also increase the input errors count. |
| Output Errors |
Output errors can increase when the output queue is undersized or when the interface is oversubscribed. |
| Total output drops |
Output drops are generally the result of interface oversubscription caused by many-to-one traffic patterns or a 10 Gbps to 1 Gbps transfer. Interface buffers are a limited resource and can absorb a burst only up to a point. After that point, packets start to drop. Buffers can be tuned to provide some cushion, but they cannot guarantee zero output drops. |
| Unknown protocol drops |
Unknown protocol drops occur when the receiving interface is not configured for that protocol or when the switch does not recognize the protocol. For example, if two switches are connected and Cisco Discovery Protocol (CDP) is disabled on one switch interface, unknown protocol drops occur on that interface. The CDP packets are no longer recognized, and the switch drops them. |
The history command allows an interface to maintain utilization history in a graphical format similar to CPU history. History can be maintained as either bits per second (bps) or packets per second (pps), as shown in this example:
Switch(config-if)#history ?
bps Maintain history in bits/second
pps Maintain history in packets/second
Along with the rate, various interface counters can be monitored:
Switch(config-if)#history [bps|pps] ?
all Include all counters
babbles Include ethernet output babbles - Babbl
crcs Include CRCs - CRCs
deferred Include ethernet output deferred - Defer
dribbles Include dribbles - Dribl
excessive-collisions Include ethernet excessive output collisions -
ExCol
flushes Include flushes - Flush
frame-errors Include frame errors - FrErr
giants Include giants - Giant
ignored Include ignored - Ignor
input-broadcasts Include input broadcasts - iBcst
input-drops Include input drops - iDrop
input-errors Include input errors - iErr
interface-resets Include interface resets - IRset
late-collisions Include ethernet late output collisions - LtCol
lost-carrier Include ethernet output lost carrier - LstCr
multi-collisions Include ethernet multiple output collisions -
MlCol
multicast Include ethernet input multicast - MlCst
no-carrier Include ethernet output no-carrier - NoCarr
output-broadcasts Include output broadcasts - oBcst
output-buffer-failures Include output buffer failures - oBufF
output-buffers-swapped-out Include output buffers swapped out - oBSwO
output-drops Include output drops - oDrop
output-errors Include output errors - oErr
output-no-buffer Include output no buffer - oNoBf
overruns Include overruns - OvrRn
pause-input Include ethernet input pause - PsIn
pause-output Include ethernet output pause - PsOut
runts Include runts - Runts
single-collisions Include ethernet single output collisions - SnCol
throttles Include throttles - Thrtl
underruns Include underruns - UndRn
unknown-protocol-drops Include unknown protocol drops - Unkno
watchdog Include ethernet output watchdog - Wtchdg
<cr> <cr>
SW_1(config-if)#
As with CPU history, graphs are available for the last 60 seconds, the last 60 minutes, and the last 72 hours. Separate graphs are maintained for input and output histograms:
Switch#show interfaces gigabitEthernet 1/0/2 history ?
60min Display 60 minute histograms only
60sec Display 60 second histograms only
72hour Display 72 hour histograms only
all Display all three histogram intervals
both Display both input and output histograms
input Display input histograms only
output Display output histograms only
| Output modifiers
<cr> <cr>
------ Sample output ---------
Switch#show interfaces tenGigabitEthernet 1/0/9 history 60sec
10
9
8
7
6
5
4
3
2
1
0....5....1....1....2....2....3....3....4....4....5....5....6
0 5 0 5 0 5 0 5 0 5 0
TenGigabitEthernet1/0/9 input rate(mbits/sec) (last 60 seconds)
10
9
8
7
6
5
4
3
2
1
0....5....1....1....2....2....3....3....4....4....5....5....6
0 5 0 5 0 5 0 5 0 5 0
TenGigabitEthernet1/0/9 output rate(mbits/sec) (last 60 seconds)
Use the show controllers ethernet-controller interface {interface{interface-number}} command to display per-interface (Transmit and Receive) traffic counters and error statistics read from the hardware. Use the phy keyword to display the interface internal registers. Use the port-info keyword to display information about the port application-specific integrated circuit (ASIC).
This is an example of output from the show controllers ethernet-controller for a specific interface:
Switch#show controllers ethernet-controller tenGigabitEthernet 2/0/1
Transmit TenGigabitEthernet2/0/1 Receive
61572 Total bytes 282909 Total bytes
0 Unicast frames 600 Unicast frames
0 Unicast bytes 38400 Unicast bytes
308 Multicast frames 3163 Multicast frames
61572 Multicast bytes 244509 Multicast bytes
0 Broadcast frames 0 Broadcast frames
0 Broadcast bytes 0 Broadcast bytes
0 System FCS error frames 0 IpgViolation frames
0 MacUnderrun frames 0 MacOverrun frames
0 Pause frames 0 Pause frames
0 Cos 0 Pause frames 0 Cos 0 Pause frames
0 Cos 1 Pause frames 0 Cos 1 Pause frames
0 Cos 2 Pause frames 0 Cos 2 Pause frames
0 Cos 3 Pause frames 0 Cos 3 Pause frames
0 Cos 4 Pause frames 0 Cos 4 Pause frames
0 Cos 5 Pause frames 0 Cos 5 Pause frames
0 Cos 6 Pause frames 0 Cos 6 Pause frames
0 Cos 7 Pause frames 0 Cos 7 Pause frames
0 Oam frames 0 OamProcessed frames
0 Oam frames 0 OamDropped frames
193 Minimum size frames 3646 Minimum size frames
0 65 to 127 byte frames 1 65 to 127 byte frames
0 128 to 255 byte frames 0 128 to 255 byte frames
115 256 to 511 byte frames 116 256 to 511 byte frames
0 512 to 1023 byte frames 0 512 to 1023 byte frames
0 1024 to 1518 byte frames 0 1024 to 1518 byte frames
0 1519 to 2047 byte frames 0 1519 to 2047 byte frames
0 2048 to 4095 byte frames 0 2048 to 4095 byte frames
0 4096 to 8191 byte frames 0 4096 to 8191 byte frames
0 8192 to 16383 byte frames 0 8192 to 16383 byte frames
0 16384 to 32767 byte frame 0 16384 to 32767 byte frame
0 > 32768 byte frames 0 > 32768 byte frames
0 Late collision frames 0 SymbolErr frames <-- Usually indicates Layer 1 issues. Large amounts of symbol errors can indicate a bad device, cable, or hardware.
0 Excess Defer frames 0 Collision fragments <-- If this counter increments, this is an indication that the ports are configured at half-duplex.
0 Good (1 coll) frames 0 ValidUnderSize frames
0 Good (>1 coll) frames 0 InvalidOverSize frames
0 Deferred frames 0 ValidOverSize frames
0 Gold frames dropped 0 FcsErr frames <-- Are the result of collisions at half-duplex, a duplex mismatch, bad hardware (NIC, cable, or port)
0 Gold frames truncated
0 Gold frames successful
0 1 collision frames
0 2 collision frames
0 3 collision frames
0 4 collision frames
0 5 collision frames
0 6 collision frames
0 7 collision frames
0 8 collision frames
0 9 collision frames
0 10 collision frames
0 11 collision frames
0 12 collision frames
0 13 collision frames
0 14 collision frames
0 15 collision frames
0 Excess collision frames
LAST UPDATE 22622 msecs AGO
Use the show platform pm interface-flaps {interface{interface-number}} command to display the number of times an interface goes down:
This is an example of output from the show platform pm interface-flaps {interface{interface-number}} for a specific interface:
Switch#show platform pm interface-flaps tenGigabitEthernet 2/0/1 Field AdminFields OperFields =============================================================== Access Mode Static Static Access Vlan Id 1 0 Voice Vlan Id 4096 0 VLAN Unassigned 0 ExAccess Vlan Id 32767 Native Vlan Id 1 Port Mode dynamic access Encapsulation 802.1Q Native disl auto Media unknown DTP Nonegotiate 0 0 Port Protected 0 0 Unknown Unicast Blocked 0 0 Unknown Multicast Blocked 0 0 Vepa Enabled 0 0 App interface 0 0 Span Destination 0 Duplex auto full Default Duplex auto Speed auto 1000 Auto Speed Capable 1 1 No Negotiate 0 0 No Negotiate Capable 1024 1024 Flow Control Receive ON ON Flow Control Send Off Off Jumbo 0 0 saved_holdqueue_out 0 saved_input_defqcount 2000 Jumbo Size 1500 Forwarding Vlans : none Current Pruned Vlans : none Previous Pruned Vlans : none Sw LinkNeg State : LinkStateUp No.of LinkDownEvents : 12 <-- Number of times the interface flapped XgxsResetOnLinkDown(10GE): Time Stamp Last Link Flapped(U) : Aug 19 14:58:00.154 <-- Last time the interface flapped LastLinkDownDuration(sec) 192 <-- Time in seconds the interface stayed down during the last flap event LastLinkUpDuration(sec): 2277 <-- Time in seconds the interface stayed up before the last flap event
Use this section for fiber links when optical health must be verified. Use the show idprom interface {interface-number} command to display the IDPROM information for the transceiver installed in the specified interface. Use the detail keyword to display detailed hexadecimal IDPROM fields.
This example shows output from the show idprom {interface{interface-number}} command for a specific interface. The High and Low Warning|Alarm thresholds values listed in this command output are the normal operational optical transceiver parameters. These values can be verified in the data sheet for the specific optic. Refer to the Cisco Optics Transceiver Modules Documentation.
Switch#show idprom interface Twe1/0/1
IDPROM for transceiver TwentyFiveGigE1/0/1 :
Description = SFP or SFP+ optics (type 3)
Transceiver Type: = GE CWDM 1550 (107)
Product Identifier (PID) = CWDM-SFP-1550 <--
Vendor Revision = A
Serial Number (SN) = SERIALNUMBER
Vendor Name = CISCO-FINISAR
Vendor OUI (IEEE company ID) = 00.90.65 (36965)
Common Language Equipment Identifier (CLEI) code = CNTRV14FAB
Cisco part number = 10-1879-03
Device State = Enabled.
Date code (yy/mm/dd) = 14/12/22
Connector type = LC.
Encoding = 8B10B (1)
Nominal bitrate = OTU-1 (2700 Mbits/s)
Minimum bit rate as % of nominal bit rate = not specified
Maximum bit rate as % of nominal bit rate = not specified
The transceiver type is 107
Link reach for 9u fiber (km) = LR-2(80km) (80)
LR-3(80km) (80)
ZX(80km) (80)
Link reach for 9u fiber (m) = IR-2(40km) (255)
LR-1(40km) (255)
LR-2(80km) (255)
LR-3(80km) (255)
DX(40KM) (255)
HX(40km) (255)
ZX(80km) (255)
VX(100km) (255)
Link reach for 50u fiber (m) = SR(2km) (0)
IR-1(15km) (0)
IR-2(40km) (0)
LR-1(40km) (0)
LR-2(80km) (0)
LR-3(80km) (0)
DX(40KM) (0)
HX(40km) (0)
ZX(80km) (0)
VX(100km) (0)
1xFC, 2xFC-SM(10km) (0)
ESCON-SM(20km) (0)
Link reach for 62.5u fiber (m) = SR(2km) (0)
IR-1(15km) (0)
IR-2(40km) (0)
LR-1(40km) (0)
LR-2(80km) (0)
LR-3(80km) (0)
DX(40KM) (0)
HX(40km) (0)
ZX(80km) (0)
VX(100km) (0)
1xFC, 2xFC-SM(10km) (0)
ESCON-SM(20km) (0)
Nominal laser wavelength = 1550 nm.
DWDM wavelength fraction = 1550.0 nm.
Supported options = Tx disable
Tx fault signal
Loss of signal (standard implementation)
Supported enhanced options = Alarms for monitored parameters
Diagnostic monitoring = Digital diagnostics supported
Diagnostics are externally calibrated
Rx power measured is "Average power"
Transceiver temperature operating range = -5 C to 75 C (commercial)
Minimum operating temperature = 0 C
Maximum operating temperature = 70 C
High temperature alarm threshold = +90.000 C
High temperature warning threshold = +85.000 C
Low temperature warning threshold = +0.000 C
Low temperature alarm threshold = -4.000 C
High voltage alarm threshold = 3600.0 mVolts
High voltage warning threshold = 3500.0 mVolts
Low voltage warning threshold = 3100.0 mVolts
Low voltage alarm threshold = 3000.0 mVolts
High laser bias current alarm threshold = 84.000 mAmps
High laser bias current warning threshold = 70.000 mAmps
Low laser bias current warning threshold = 4.000 mAmps
Low laser bias current alarm threshold = 2.000 mAmps
High transmit power alarm threshold = 7.4 dBm
High transmit power warning threshold = 4.0 dBm
Low transmit power warning threshold = -1.7 dBm
Low transmit power alarm threshold = -8.2 dBm
High receive power alarm threshold = -3.0 dBm
Low receive power alarm threshold = -33.0 dBm
High receive power warning threshold = -7.0 dBm
Low receive power warning threshold = -28.2 dBm
External Calibration: bias current slope = 1.000
External Calibration: bias current offset = 0
This table lists the commands that can be used to troubleshoot link flaps. Recommended order of use: show logging, show interfaces, show controllers ethernet-controller, show platform pm interface-flaps, and then fiber-specific or copper-specific commands as applicable.
| Command |
Purpose |
| show interfaces counters errors |
Displays the interface error counters. |
| show interfaces capabilities |
Displays the capabilities of the specific interface. |
| show interface transceivers (fiber or SFP specific) |
Displays information about the optical transceivers that have digital optical monitoring (DOM) enabled. |
| show interface link |
Displays link level information. |
| show interface {interface{interface-number}} platform |
Displays interface platform information. |
| show controllers ethernet-controller {interface{interface-number}} port-info |
Displays additional port information. |
| show controllers ethernet-controller {interface{interface-number}} link status detail |
Displays link status. |
| show errdisable flap-values |
Displays the number of flaps that are allowed to occur before the errdisable status. |
| clear counters |
Use this command to zero the traffic and error counters so that you can see if the problem is only temporary, or if the counters continue to increment. |
| clear controllers ethernet-controller |
Use this command to clear the hardware Transmit and Receive counters. |
The Time Domain Reflectometer (TDR) feature allows you to determine if a cable is OPEN or SHORT when it is at fault. With TDR, you can check the status of copper cables for the ports on the Catalyst 9000 Series Switches. TDR detects a cable fault with a signal that is sent through the cable and read the signal that is reflected back. All or part of the signal can be reflected back due to defects in the cable
Use the test cable-diagnostics tdr {interface{interface-number} } to start the TDR test, then use the show cable-diagnostics tdr {interfaceinterface-number}.
The example shows a TDR test result for interface Tw2/0/10:
Switch#show cable-diagnostics tdr interface tw2/0/10
TDR test last run on: November 05 02:28:43
Interface Speed Local pair Pair length Remote pair Pair status
--------- ----- ---------- ------------------ ----------- --------------------
Tw2/0/10 1000M Pair A 1 +/- 5 meters Pair A Impedance Mismatch
Pair B 1 +/- 5 meters Pair B Impedance Mismatch
Pair C 1 +/- 5 meters Pair C Open
Pair D 3 +/- 5 meters Pair D Open
These guidelines apply to the use of TDR:
Digital Optical Monitoring (DOM) is an industry wide standard, intended to define a digital interface to access real-time parameters such as:
The table list the commands you can used to turn on/off DOM for all transceivers type in the system:
| Steps |
Command or Action |
Purpose |
| Step 1 |
enable Example: switch > enable |
Enables the physical EXEC mode. Enter your password if prompted. |
| Step 2 |
configure terminal Example: switch#configure terminal |
Enters Global configuration mode. |
| Step 3 |
transceiver type all Example: switch(config)#transceiver type all |
Enters the Transceiver type configuration mode. |
| Step 4 |
monitoring Example: switch(config)#monitoring |
Enables monitoring of all optical transceivers. |
Use the show interfaces {interface{interface-number}} transceiver detail command to display transceiver information:
Switch#show interfaces hundredGigE 1/0/25 transceiver detail
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
--------- ----------------- ---------- --------- --------- ---------
Hu1/0/25 28.8 75.0 70.0 0.0 -5.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
--------- ----------------- ---------- --------- --------- ---------
Hu1/0/25 3.28 3.63 3.46 3.13 2.97
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port Lane (milliamperes) (mA) (mA) (mA) (mA)
--------- ---- --------------- ---------- --------- --------- ---------
Hu1/0/25 N/A 6.2 10.0 8.5 3.0 2.6
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port Lane (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ---- --------------- ---------- --------- --------- ---------
Hu1/0/25 N/A -2.2 1.7 -1.3 -7.3 -11.3
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port Lane (dBm) (dBm) (dBm) (dBm) (dBm)
--------- ---- --------------- ---------- --------- --------- ---------
Hu1/0/25 N/A -16.7 2.0 -1.0 -9.9 -13.9
This section describes the most relevant threshold violation syslog messages:
Temperature Levels of SFP optics
%SFF8472-3-THRESHOLD_VIOLATION: Te7/3: Temperature high alarm; Operating value: 88.7 C, Threshold value: 74.0 C.
%SFF8472-3-THRESHOLD_VIOLATION: Fo1/1/1: Temperature low alarm; Operating value: 0.0 C, Threshold value: 35.0 C.
Voltage Levels of SFP Optics
%SFF8472-3-THRESHOLD_VIOLATION: Gi1/1/3: Voltage high warning; Operating value: 3.50 V, Threshold value: 3.50 V.
%SFF8472-5-THRESHOLD_VIOLATION: Gi1/1: Voltage low alarm; Operating value: 2.70 V, Threshold value: 2.97 V.
Light Levels of SFP Optics
%SFF8472-3-THRESHOLD_VIOLATION: Gi1/0/1: Rx power high warning; Operating value: -2.7 dBm, Threshold value: -3.0 dBm.
%SFF8472-5-THRESHOLD_VIOLATION: Te1/1: Rx power low warning; Operating value: -13.8 dBm, Threshold value: -9.9 dBm.
FEC is a technique used to detect and correct a certain number of errors in a bitstream and appends redundant bits and error-checking code to the message block before transmission. As a module manufacturer, Cisco takes care to design our transceivers to comply with specifications. When the optical transceiver is operated in a Cisco host platform, the FEC is enabled by default based on the optical module type that the host software detects (See this downloadable table). In the vast majority of cases, the FEC implementation is dictated by the industry standard that the optic type supports.
For certain custom specifications, FEC implementations vary. Refer to Understanding FEC and its Implementation in Cisco Optics document for detailed information.
The example shows how to configure FEC and some of the available options:
switch(config-if)#fec? auto Enable FEC Auto-Neg cl108 Enable clause108 with 25G cl74 Enable clause74 with 25G off Turn FEC off
Use the show interface command to verify FEC configuration:
TwentyFiveGigE1/0/13 is up, line protocol is up (connected)
Hardware is Twenty Five Gigabit Ethernet, address is 3473.2d93.bc8d (bia 3473.2d93.bc8d)
MTU 9170 bytes, BW 25000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full-duplex, 25Gb/s, link type is force-up, media type is SFP-25GBase-SR
Fec is auto < -- The configured setting for FEC is displayed here
input flow-control is on, output flow-control is off
ARP type: ARPA, ARP Timeout 04:00:00
--snip--
This table lists the various commands that can be used to debug Port Flaps
| Command | Purpose |
| debug pm | Port Manager debugging |
| debug pm port | Port related events |
| debug platform pm | NGWC Platform Port Manager Debug Info |
| debug platform pm l2-control | NGWC L2 Control Infra debug |
| debug platform pm link-status | Interface link detection events |
| debug platform pm pm-vectors | Port Manager Vector Functions |
| debug condition interface <interface name> | Selectively enable debugs for specific interface |
| debug interface state | States transitions |
This is a partial sample output example of the debug commands listed in the table:
SW_2#sh debugging
PM (platform):
L2 Control Infra debugging is on <-- debug platform pm l2-control
PM Link Status debugging is on <-- debug platform pm link-status
PM Vectors debugging is on <-- debug platform pm pm-vectors
Packet Infra debugs:
Ip Address Port
------------------------------------------------------|----------
Port Manager:
Port events debugging is on <-- debug pm port
Condition 1: interface Te1/0/2 (1 flags triggered)
Flags: Te1/0/2
------ Sample output ---------
*Aug 25 20:01:05.791: link up/down event : link-down on Te1/0/2
*Aug 25 20:01:05.791: pm_port 1/2: during state access, got event 5(link_down) <-- Link down event (day/time)
*Aug 25 20:01:05.791: @@@ pm_port 1/2: access -> pagp
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Vp Disable: pd=0x7F1E797914B0 dpidx=10 Te1/0/2
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:05.792: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:05.792: Maintains count of VP per Interface:delete, pm_vp_counter[0]: 14, pm_vp_counter[1]: 14
*Aug 25 20:01:05.792: *** port_modechange: 1/2 mode_none(10)
*Aug 25 20:01:05.792: @@@ pm_port 1/2: pagp -> dtp
*Aug 25 20:01:05.792: stop flap timer : Te1/0/2 pagp
*Aug 25 20:01:05.792: *** port_bndl_stop: 1/2 : inform yes
*Aug 25 20:01:05.792: @@@ pm_port 1/2: dtp -> present
*Aug 25 20:01:05.792: *** port_dtp_stop: 1/2
*Aug 25 20:01:05.792: stop flap timer : Te1/0/2 pagp
*Aug 25 20:01:05.792: stop flap timer : Te1/0/2 dtp
*Aug 25 20:01:05.792: stop flap timer : Te1/0/2 unknown
*Aug 25 20:01:05.792: *** port_linkchange: reason_link_change(3): link_down(0)1/2 <-- State link change
*Aug 25 20:01:05.792: pm_port 1/2: idle during state present
*Aug 25 20:01:05.792: @@@ pm_port 1/2: present -> link_down <-- State of the link
*Aug 25 20:01:06.791: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/2, changed state to down
*Aug 25 20:01:07.792: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/2, changed state to down
*Aug 25 20:01:11.098: IOS-FMAN-PM-DEBUG-LINK-STATUS: Received LINKCHANGE in xcvr message, if_id 10 (TenGigabitEthernet1/0/2)
*Aug 25 20:01:11.098: IOS-FMAN-PM-DEBUG-LINK-STATUS: if_id 0xA, if_name Te1/0/2, link up <-- Link became up
*Aug 25 20:01:11.098: link up/down event: link-up on Te1/0/2
*Aug 25 20:01:11.098: pm_port 1/2: during state link_down, got event 4(link_up)
*Aug 25 20:01:11.098: @@@ pm_port 1/2: link_down -> link_up
*Aug 25 20:01:11.098: flap count for link type : Te1/0/2 Linkcnt = 0
*Aug 25 20:01:11.099: pm_port 1/2: idle during state link_up
*Aug 25 20:01:11.099: @@@ pm_port 1/2: link_up -> link_authentication
*Aug 25 20:01:11.099: pm_port 1/2: during state link_authentication, got event 8(authen_disable)
*Aug 25 20:01:11.099: @@@ pm_port 1/2: link_authentication -> link_ready
*Aug 25 20:01:11.099: *** port_linkchange: reason_link_change(3): link_up(1)1/2
*Aug 25 20:01:11.099: pm_port 1/2: idle during state link_ready
*Aug 25 20:01:11.099: @@@ pm_port 1/2: link_ready -> dtp
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Set pm vp mode attributes for Te1/0/2 vlan 1
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.099: pm_port 1/2: during state dtp, got event 13(dtp_complete)
*Aug 25 20:01:11.099: @@@ pm_port 1/2: dtp -> dtp
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Set pm vp mode attributes for Te1/0/2 vlan 1
*Aug 25 20:01:11.099: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.099: DTP flapping: flap count for dtp type: Te1/0/2 Dtpcnt = 0
*Aug 25 20:01:11.099: pm_port 1/2: during state dtp, got event 110(dtp_done)
*Aug 25 20:01:11.099: @@@ pm_port 1/2: dtp -> pre_pagp_may_suspend
*Aug 25 20:01:11.099: pm_port 1/2: idle during state pre_pagp_may_suspend
*Aug 25 20:01:11.099: @@@ pm_port 1/2: pre_pagp_may_suspend -> pagp_may_suspend
*Aug 25 20:01:11.099: pm_port 1/2: during state pagp_may_suspend, got event 33(pagp_continue)
*Aug 25 20:01:11.099: @@@ pm_port 1/2: pagp_may_suspend -> start_pagp
*Aug 25 20:01:11.099: pm_port 1/2: idle during state start_pagp
*Aug 25 20:01:11.099: @@@ pm_port 1/2: start_pagp -> pagp
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Set pm vp mode attributes for Te1/0/2 vlan 1
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: *** port_bndl_start: 1/2
*Aug 25 20:01:11.100: stop flap timer : Te1/0/2 pagp
*Aug 25 20:01:11.100: pm_port 1/2: during state pagp, got event 34(dont_bundle)
*Aug 25 20:01:11.100: @@@ pm_port 1/2: pagp -> pre_post_pagp
*Aug 25 20:01:11.100: pm_port 1/2: idle during state pre_post_pagp
*Aug 25 20:01:11.100: @@@ pm_port 1/2: pre_post_pagp -> post_pagp
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: pm_port 1/2: during state post_pagp, got event 14(dtp_access)
*Aug 25 20:01:11.100: @@@ pm_port 1/2: post_pagp -> access
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Set pm vp mode attributes for Te1/0/2 vlan 1
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.100: Maintains count of VP per Interface:add, pm_vp_counter[0]: 15, pm_vp_counter[1]: 15
*Aug 25 20:01:11.100: IOS-FMAN-PM-DEBUG-PM-VECTORS: vlan vp enable for port(Te1/0/2) and vlan:1
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: VP ENABLE: vp_pvlan_port_mode:access for Te1/0/2
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: VP Enable: vp_pvlan_native_vlanId:1 for Te1/0/2
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.101: *** port_modechange: 1/2 mode_access(1)
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: The operational mode of Te1/0/2 in set all vlans is 1
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: vp_pvlan port_mode:access vlan:1 for Te1/0/2
*Aug 25 20:01:11.101: IOS-FMAN-PM-DEBUG-PM-VECTORS: vp_pvlan port_mode:access native_vlan:1 for Te1/0/2
*Aug 25 20:01:11.102: IOS-FMAN-PM-DEBUG-PM-VECTORS: Success sending PM tdl message
*Aug 25 20:01:13.098: %LINK-3-UPDOWN: Interface TenGigabitEthernet1/0/2, changed state to up
*Aug 25 20:01:14.098: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/2, changed state to up
| Cisco Bug ID |
Description |
| Cisco bug ID CSCvu13029 |
Intermittent Link Flaps on mGig Cat9300 switches to mGig capable endpoints. |
| Cisco bug ID CSCvt50788 |
Cat9400 mGig interop issues with other mGig devices causes link flaps. |
| Cisco bug ID CSCvu92432 |
CAT9400: Mgig interface Flaps with Mgig APs. |