Contents
- Upgrading the Firmware from Release 1.2(1) to Release 1.4(1)
- Required Order of Steps When Upgrading from Release 1.2(1)
- Required Order of Steps for Adding a Cisco UCS B230 Server
- Required Order of Steps for Integrating a Cisco UCS Rack-Mount Server
- Disabling Call Home
- Updating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
- Activating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
- Activating the Board Controller Firmware on a Server to Release 1.4(1)
- Activating the Cisco UCS Manager Software to Release 1.4(1)
- Activating the Fabric Interconnect Firmware for a Cluster Configuration
- Activating the Firmware on a Subordinate Fabric Interconnect to Release 1.4(1)
- Activating the Firmware on a Primary Fabric Interconnect to Release 1.4(1)
- Activating the Firmware on a Standalone Fabric Interconnect to Release 1.4(1)
- Updating a Host Firmware Package to Release 1.4(1)
- Enabling Call Home
Upgrading the Firmware from Release 1.2(1) to Release 1.4(1)
This chapter includes the following sections:
- Required Order of Steps When Upgrading from Release 1.2(1)
- Disabling Call Home
- Updating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
- Activating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
- Activating the Board Controller Firmware on a Server to Release 1.4(1)
- Activating the Cisco UCS Manager Software to Release 1.4(1)
- Activating the Fabric Interconnect Firmware for a Cluster Configuration
- Activating the Firmware on a Standalone Fabric Interconnect to Release 1.4(1)
- Updating a Host Firmware Package to Release 1.4(1)
- Enabling Call Home
Required Order of Steps When Upgrading from Release 1.2(1)
When you upgrade from Cisco UCS, Release 1.2(1), upgrade the components in the following order. If you do not follow this order, the firmware upgrade may fail and the servers may experience communication issues with Cisco UCS Manager. In addition, the order of steps in this document and the recommended options minimize the disruption to data traffic.
(Optional) Call Home—If the Cisco UCS instance includes Call Home or Smart Call Home, disable Call Home if you do not want to receive unnecessary alerts when Cisco UCS Manager restarts components to complete the firmware activation.
Adapter—If you plan to upgrade the adapters directly, perform this step first. However, if you prefer or if the adapters require it, you can omit this step and upgrade the adapters as part of the last step, in a host firmware package.
BMC—If you upgrade the adapters in the host firmware package, perform this step first.
Cisco UCS Manager.
I/O module—Activate with Set Startup Version only.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the subordinate fabric interconnect first.
Fabric interconnect—If you are upgrading a system with a cluster configuration, activate the primary fabric interconnect second
Host firmware package—Must be the last step in the upgrade process. We recommend that you upgrade the board controller firmware during this step to avoid an additional reboot of the server. You must upgrade the following firmware in a host firmware package:
(Optional) Call Home—If you disabled Call Home before the upgrading the firmware, enable Call Home.
Note
In Release 1.3(1) the BMC was renamed to CIMC Controller. After you upgrade from this release, Cisco UCS Manager no longer uses the term BMC. Because this document is aimed at upgrading to the current release, the term CIMC is sometimes used rather than BMC.
- Required Order of Steps for Adding a Cisco UCS B230 Server
- Required Order of Steps for Integrating a Cisco UCS Rack-Mount Server
Required Order of Steps for Adding a Cisco UCS B230 Server
When you add the first B230 server, you must perform the steps in the following order to add support in Cisco UCS Manager for the server:
If you have not already done so, upgrade the Cisco UCS instance to Release 1.4(1).
Insert the blade server into the chassis as described in the server installation guide.
Wait for Cisco UCS Manager to discover the new server. If server discovery does not begin within a few minutes, acknowledge the server.
Note
You do not need to update the Management Extensions or Capability Catalog to add a B230 server. The required support is included in the Cisco UCS, Release 1.4(1) infrastructure bundle.
Required Order of Steps for Integrating a Cisco UCS Rack-Mount Server
After you complete the upgrade of the existing Cisco UCS components, you can integrate a Cisco UCS rack-mount server. When you integrate a rack-mount server, you must perform the steps in the following order:
If you have not already done so, configure the rack server discovery policy in Cisco UCS Manager.
Follow the instructions in the server installation guide for installing and integrating a rack-mount server in a system managed by Cisco UCS Manager.
Wait for Cisco UCS Manager to discover the new server. If server discovery does not begin within a few minutes, acknowledge the server.
Disabling Call Home
ProcedureThis step is optional.
When you upgrade a Cisco UCS instance, Cisco UCS Manager restarts the components to complete the upgrade process. This restart causes events that are identical to service disruptions and component failures that trigger Call Home alerts to be sent. If you do not disable Call Home before you begin the upgrade, you can ignore the alerts generated by the upgrade-related component restarts.
Updating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
Procedure
Caution
Do not remove the hardware that contains the endpoint or perform any maintenance on it until the update process has completed. If the hardware is removed or otherwise unavailable due to maintenance, the firmware update fails. This failure may corrupt the backup partition. You cannot update the firmware on an endpoint with a corrupted backup partition.
Step 1 In the Navigation pane, click the Equipment tab. Step 2 On the Equipment tab, click the Equipment node. Step 3 In the Work pane, click the Firmware Management tab. Step 4 On the Installed Firmware subtab, click Update Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 5 In the Update Firmware dialog box, do the following:
Cisco UCS Manager copies the selected firmware image to the backup memory partition and verifies that the image is not corrupt. The image remains as the backup version until you explicitly activate it. Cisco UCS Manager begins all updates at the same time. However, some updates may complete at different times.
The update is complete when the Update Firmware dialog box displays ready in the Update Status column for all updated endpoints.
Step 6 When all updates are completed, click OK.
What to Do Next
Activate the firmware.
Activating the Firmware on the Adapters, BMCs, and IOMs to Release 1.4(1)
ProcedureThis procedure ensures that the firmware activation for these endpoints causes minimal disruption to data traffic. If you do not activate the endpoints in the following order with the correct options configured, the endpoints may reboot and cause a temporary disruption in data traffic.
Caution
Do not select ALL from the Filter drop-down list in the Activate Firmware dialog box to activate all endpoints simultaneously. Many firmware releases and patches have dependencies that require the endpoints to be activated in a specific order for the firmware update to succeed. This order can change depending upon the contents of the release or patch. Activating all endpoints does not guarantee that the updates occur in the required order and can disrupt communications between the endpoints, the fabric interconnects, and Cisco UCS Manager. For information about the dependencies in a specific release or patch, see the release notes provided with that release or patch.
This procedure continues directly from the previous one and assumes you are on the Firmware Management tab.
Step 1 In the Installed Firmware tab, choose Activate Firmware. If one or more of the selected endpoints are not configured with the desired version as the backup version, Cisco UCS Manager GUI does not display that version in the Set Version drop-down list. You must select the version from the Startup Version column for each individual endpoint.
Step 2 If the adapter firmware is not updated through a host firmware package in a service profile, do the following in the Activate Firmware dialog box to activate the adapter firmware:
Step 3 If the BMC firmware is not updated through a management firmware package in a service profile, do the following in the Activate Firmware dialog box to activate the BMC firmware:
Step 4 To activate the IOM firmware, do the following in the Activate Firmware dialog box:
Step 5 Click OK.
Activating the Board Controller Firmware on a Server to Release 1.4(1)
ProcedureOnly certain servers, such as the Cisco UCS B440 High Performance blade server and the Cisco UCS B230 blade server, have board controller firmware. The board controller firmware controls many of the server functions, including eUSBs, LEDs, and I/O connectors.
This procedure continues from the previous one and assumes that you are on the Installed Firmware tab.
Note
This activation procedure causes the server to reboot. Depending upon whether or not the service profile associated with the server includes a maintenance policy, the reboot can occur immediately. To reduce the number of times a server needs to be rebooted during the upgrade process, we recommend that you upgrade the board controller firmware through the host firmware package in the service profile.
Step 1 On the Installed Firmware subtab, click Activate Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 2 From the Filter drop-down list on the menu bar of the Activate Firmware dialog box, select Board Controller. Cisco UCS Manager GUI displays all servers that have board controllers in the Activate Firmware dialog box.
Step 3 From the Set Version drop-down list on the menu bar of the Activate Firmware dialog box, choose the board controller firmware version included in the Release 1.4(1) firmware bundle. Step 4 Check the Ignore Compatibility Check check box. Step 5 Click OK.
Activating the Cisco UCS Manager Software to Release 1.4(1)
ProcedureThis procedure continues directly from the previous one and assumes you are on the Firmware Management tab.
Step 1 On the Installed Firmware subtab, click Activate Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 2 From the Filter drop-down list, choose UCS Manager. Step 3 On the UCS Manager row of the Activate Firmware dialog box, do the following: Step 4 Click OK. Cisco UCS Manager disconnects all active sessions, logs out all users, and activates the software. When the upgrade is complete, you are prompted to log back in.
Activating the Firmware on a Subordinate Fabric Interconnect to Release 1.4(1)
Before You BeginProcedureDetermine which fabric interconnect in the cluster is the subordinate fabric interconnect. For more information, see Verifying the High Availability Status and Roles of a Cluster Configuration.
Step 1 In the Navigation pane, click the Equipment tab. Step 2 On the Equipment tab, click the Equipment node. Step 3 In the Work pane, click the Firmware Management tab. Step 4 On the Installed Firmware subtab, click Activate Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 5 From the Filter drop-down list on the menu bar, choose Fabric Interconnects. Step 6 On the menu bar, check the Ignore Compatibility Check check box. Step 7 On the row of the Activate Firmware dialog box for the subordinate fabric interconnect, do the following: Step 8 Click Apply. Cisco UCS Manager updates and activates the firmware and reboots the fabric interconnect and any I/O module in the data path to that fabric interconnect, disrupting data traffic to and from that fabric interconnect. However, assuming the Cisco UCS instance is configured to permit traffic and port failover, data traffic fails over to the primary fabric interconnect and is not disrupted.
Step 9 Verify the high availability status of the subordinate fabric interconnect.
Note If the High Availability Details area for the fabric interconnect does not show the following values, contact Cisco Technical Support immediately. Do not continue to update the primary fabric interconnect.
What to Do Next
If the high availability status of the subordinate fabric interconnect contains the required values, update and activate the primary fabric interconnect.
Activating the Firmware on a Primary Fabric Interconnect to Release 1.4(1)
ProcedureThis procedure continues directly from the previous one and assumes you are on the Firmware Management tab.
Step 1 On the Installed Firmware subtab, click Activate Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 2 From the Filter drop-down list on the menu bar, choose Fabric Interconnects. Step 3 On the menu bar, check the Ignore Compatibility Check check box. Step 4 On the row of the Activate Firmware dialog box for the primary fabric interconnect, do the following: Step 5 Click Apply. Cisco UCS Manager updates and activates the firmware and reboots the fabric interconnect and any I/O module in the data path to that fabric interconnect, disrupting data traffic to and from that fabric interconnect. However, assuming the Cisco UCS instance is configured to permit traffic and port failover, data traffic fails over to the other fabric interconnect, which becomes the primary. When it comes back up, this fabric interconnect is the subordinate fabric interconnect.
Step 6 Verify the high availability status of the fabric interconnect.
Note If the High Availability Details area for the fabric interconnect does not show the following values, contact Cisco Technical Support immediately.
Activating the Firmware on a Standalone Fabric Interconnect to Release 1.4(1)
ProcedureFor a standalone configuration with a single fabric interconnect, you can minimize the disruption to data traffic when you perform a direct firmware upgrade of the endpoints. However, you must reboot the fabric interconnect to complete the upgrade and, therefore, cannot avoid disrupting traffic.
Step 1 In the Navigation pane, click the Equipment tab. Step 2 On the Equipment tab, click the Equipment node. Step 3 In the Work pane, click the Firmware Management tab. Step 4 On the Installed Firmware subtab, click Activate Firmware. Cisco UCS Manager GUI opens the Update Firmware dialog box and verifies the firmware versions for all endpoints in the Cisco UCS instance. This step may take a few minutes, depending upon the number of chassis and servers.
Step 5 From the Filter drop-down list, choose Fabric Interconnects. Step 6 On the menu bar, check the Ignore Compatibility Check check box. Step 7 On the row of the Activate Firmware dialog box for the fabric interconnect, do the following: Step 8 Click OK.
Cisco UCS Manager activates the firmware and reboots the fabric interconnect and any I/O module in the data path to that fabric interconnect. For a standalone fabric interconnect, this disrupts all data traffic in the Cisco UCS instance.
Updating a Host Firmware Package to Release 1.4(1)
You must upgrade the BIOS and storage controller firmware through the host firmware package when you upgrade to Release 1.4(1). If you do not upgrade those packages, the servers may experience communication issues with Cisco UCS Manager and the CIMC.
Caution
If the policy is included in one or more service profiles associated with a server and those service profiles do not include maintenance policies, Cisco UCS Manager updates and activates the firmware in the server and adapter with the new versions and reboots the server as soon as you save the host firmware package policy.
This procedure assumes that the host firmware package already exists and that you have upgraded Cisco UCS Manager to Release 1.4(1). For information on how to create a host firmware package or on how to update an existing one in a previous release , see the appropriate Cisco UCS Manager GUI Configuration Guide for the release that Cisco UCS Manager is running.
Before You BeginProcedureBefore you update a host firmware package, do the following:
Upgrade Cisco UCS Manager and the fabric interconnects.
Determine an appropriate maintenance window to reduce the impact of the disruption of data traffic when the server reboots.
Ensure you know the 1.4(1) firmware version and model number (PID) for the servers or servers.
Step 1 In the Navigation pane, click the Servers tab. Step 2 On the Servers tab, expand . Step 3 Expand the node for the organization that includes the policy you want to update. If the system does not include multi-tenancy, expand the root node.
Step 4 Expand Host Firmware Packages and choose the policy you want to update. Step 5 On each subtab of the General tab, do the following for each type of firmware you want to include in the package:
Step 6 Click Save Changes. Cisco UCS Manager verifies the model numbers and vendor against all servers associated with service profiles that include this policy. If the model numbers and vendor match a firmware version in the policy, Cisco UCS Manager updates the firmware according to the settings in the maintenance policies included in the service profiles.
What to Do Next
Verify that the firmware on the endpoints included in the host firmware package has been updated to release 1.4(1). If the firmware has not been updated, check the model numbers and vendors in the host firmware package against those on the endpoints that were not updated.
Enabling Call Home
ProcedureThis step is optional. You only need to enable Call Home if you disabled it before you began the firmware upgrades.
Step 1 In the Navigation pane, click the Admin tab. Step 2 In the Admin tab, expand . Step 3 Click Call Home. Step 4 In the Work pane, click the General tab. Step 5 In the Admin area, click on in the State field.
Note If this field is set to on, Cisco UCS Manager GUI displays the rest of the fields on this tab.
Step 6 Click Save Changes.