System Specifications
This appendix lists the technical specifications for the Cisco UCS S3260 Storage Server and includes the following sections:
The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This appendix lists the technical specifications for the Cisco UCS S3260 Storage Server and includes the following sections:
Table A-1 lists the physical specifications for the system.
|
Description |
Specification |
|---|---|
|
Height |
6.88 in (174 mm) |
|
Width |
17.46 in (444 mm) |
|
Length (including front handles) Length (including front handles and slide rails with CMA) |
33.54 in (852 mm) 40.30 in (1024 mm) |
|
Weight (maximum configuration) |
195 lbs (88 kg) |
Table A-2 lists the environmental specifications for the system.
|
Description |
Specification |
|---|---|
|
Temperature, operating |
5oC to 35oC (41oF to 95oF) |
|
Temperature, nonoperating |
–40oC to 65oC (–40oF to 149oF) |
| Humidity, operating |
10% to 90% non-condensing |
|
Humidity, nonoperating |
5% to 93% non-condensing |
|
Altitude, operating Derated 1oC for each 305 m |
0 m to 3048 m (0 ft to 10,000 ft) |
|
Altitude, nonoperating |
0 m to 12,192 m (0 ft to 40,000 ft) |
|
Acoustic noise, operating |
LWAd 5.4 Bel LpAm 38 dBA |
The power specifications for the power supply options are listed in the following sections:
1050 W AC Power Supply (UCSC-PSU1-1050W), page A-3
1050 W DC Power Supply (UCSC-PSUV2-1050DC), page A-4
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
http://ucspowercalc.cisco.com
Note |
Do not mix power supply types in the server. Both power supplies must be identical. |
Note |
The voltage sensor reading via PMBus for the power supplies in all UCS servers has +/- 5% tolerance. |
The following table lists the specifications for each 1050 W AC power supply (Cisco part number UCSC-PSU1-1050W).
|
Description |
Specification |
|---|---|
|
DC input voltage range |
Nominal range: –48 to –60 VDC nominal (Range: –40 to –72 VDC) |
|
Maximum DC input current |
32 A at –40 VDC |
|
Maximum input W |
1234 W |
|
Maximum output power per PSU |
1050 W on 12 VDC main power 36 W on 12 VDC standby power |
|
Maximum inrush current |
35 A (sub-cycle duration) |
|
Maximum hold-up time |
5 ms at 100% load (1050 W main and 36 W standby) |
|
Power supply output voltage |
12 VDC |
|
Power supply standby voltage |
12 VDC |
|
Efficiency rating |
≥ 92% at 50% load |
|
Form factor |
RSP2 |
|
Input connector |
Fixed 3-wire block |
The following table lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).
|
Description |
Specification |
|---|---|
|
DC input voltage range |
Nominal range: –48 to –60 VDC nominal (Range: –40 to –72 VDC) |
|
Maximum DC input current |
32 A at –40 VDC |
|
Maximum input W |
1234 W |
|
Maximum output power per PSU |
1050 W on 12 VDC main power 36 W on 12 VDC standby power |
|
Maximum inrush current |
35 A (sub-cycle duration) |
|
Maximum hold-up time |
5 ms at 100% load (1050 W main and 36 W standby) |
|
Power supply output voltage |
12 VDC |
|
Power supply standby voltage |
12 VDC |
|
Efficiency rating |
≥ 92% at 50% load |
|
Form factor |
RSP2 |
|
Input connector |
Fixed 3-wire block |