About Intersight Managed Mode

About Intersight Managed Mode

Cisco Intersight™ is a management platform delivered as a service with embedded analytics for your Cisco and 3rd party IT infrastructure. Intersight Managed Mode (IMM) is a new architecture that manages the UCS Fabric Interconnected systems through a Redfish-based standard model. Intersight Managed Mode unifies the capabilities of the UCS Systems and the cloud-based flexibility of Intersight, thus unifying the management experience for the standalone and Fabric Interconnect attached systems. Intersight Management Model standardizes policy and operation management for UCS-FI-6454, UCS-FI-64108, UCS-FI-6536, UCSX-S9108-100G, and UCS-FI-6664 Fabric Interconnects and Cisco UCS B-Series (M5, M6), Cisco UCS C-Series (M5, M6, M7, M8), and Cisco UCS X-Series (M6, M7, M8) servers.

You can choose between the native UCSM Managed Mode (UMM) or Intersight Managed Mode (IMM) for the Fabric attached UCS Systems during initial setup of the Fabric Interconnects. If you choose to switch back between UMM and IMM, you must erase the present configuration and start from initial setup.


Note


Before erasing the configuration, you must ensure to unclaim the device from Intersight and decommission all rack servers.


  • Before you set up Intersight Managed Mode, please review the system requirements, supported hardware and software, and the steps required to migrate from UMM to IMM.

  • For latest updates on Intersight features and functionality, see Help Center.

  • Servers in IMM mode require a minimum of Essentials license.

Supported Hardware

Table 1. Supported Hardware Components with Required Minimum Infrastructure Versions

Fabric Components

Model

Component

Sub-Component

Sub-Component Model

Minimum Infrastructure Firmware Versions

UCS-FI-6664

Fabric Interconnect

6.0(1.250198)

UCSX-S9108-100G

Fabric Interconnect

4.3(4.240078)

UCS-FI-6454

Fabric Interconnect

4.1(3b)

UCS-FI-64108

Fabric Interconnect

4.1(3b)

UCS-FI-6536

Fabric Interconnect

4.2(2b)

N20-C6508

UCSB-5108-AC2

Chassis

4.1(3b)

Input/Output Module (IOM)

UCS-IOM-2204XP

UCS-IOM-2208XP

UCS-IOM-2408

4.1(3b)

UCS-IOM-2304

UCS-IOM-2304V2

4.2(3c)

UCSX-9508

Chassis

4.2(1e)

X-Fabric Modules (XFM)

UCSX-F-9416

4.2(2a)

Intelligent Fabric Module (IFM)

UCSX-I-9108-25G

4.2(1e)

UCSX-I-9108-100G

4.2(2a)

Cisco Nexus 2232PP

Fabric Extender (FEX)

4.1(3b)

N9K-C93108YC-FX3

Fabric Extender (FEX)

4.2(2a)


Note


  • The Intersight Managed Mode (IMM) supports up to 20 chassis and 160 servers.

  • Cisco UCS 6454 and 64108 Fabric Interconnects, require the port-based licensing in IMM but will not be enforced until further notice.

    Beginning with UCS software release version 4.2(3), Cisco UCS 6536, Cisco UCS 6664, and UCS X-Direct Fabric Interconnects support a perpetual software license, activating all ports and features.

  • Swapping or moving cable connections on rack network adapters, whether between VIC ports on the same Fabric Interconnect or between different Fabric Interconnects, is not supported while the server is powered on after server discovery. Such actions are only permitted when the server is powered off through a soft shutdown.

  • The minimum supported Infrastructure firmware version for Intersight Managed Mode is 4.1(3).


Supported Servers

The following table lists the server models supported in Intersight Managed Mode across different generations. For more information on specific components of the servers, see (Table 3).

Table 2. Supported Server Models

Server Generation

Supported Model

M8

Cisco UCS X210c M8 Compute Node

Cisco UCS X215c M8 Compute Node

Cisco UCS C220 M8 Server

Cisco UCS C240 M8 Server

Cisco UCS C225 M8 Server

Cisco UCS C245 M8 Server

M7

Cisco UCS X210c M7 Compute Node

Cisco UCS X410c M7 Compute Node

Cisco UCS C220 M7 Server

Cisco UCS C240 M7 Server

M6

Cisco UCS X210c M6 Compute Node

Cisco UCS B200 M6 Server

Cisco UCS C220 M6 Server

Cisco UCS C240 M6 Server

Cisco UCS C225 M6 Server

Cisco UCS C245 M6 Server

M5*

Cisco UCS B200 M5 Server

Cisco UCS B480 M5 Server

Cisco UCS C220 M5 Server

Cisco UCS C240 M5 Server, Cisco UCS C240 SD M5 Server

Cisco UCS C480 M5 Server *

* Cisco UCS C480 ML M5, Cisco UCS C125 M5, and Cisco UCS S3260 M5 servers are not supported in Intersight Managed Mode.

Table 3. Supported Hardware Components with Required Minimum Firmware Versions

Supported Components for Servers

Model

Component

Sub-Component

Sub-Component Model

Minimum Infrastructure Firmware Versions

Minimum Server Firmware Versions

Cisco UCS X210c M8 Compute Node

X-Series Intel M8 Compute Node

  • 6664 FI: 6.0(1.250198)

  • X-Direct FI: 4.3(6.250094)

  • 6400 Series and 6536 FI: 4.3(6.250048)

5.4(0.250037)

Cisco UCS X215c M8 Compute Node

X-Series AMD M8 Compute Node

  • 6664 FI: 6.0(1.250198)

  • X-Direct FI: 4.3(5.240162)

  • 6400 Series and 6536 FI: 4.3(2.230117)

5.3(0.240016)

New Hardware Supported Since Initial Release

CPU

5th Generation AMD EPYC CPU:

  • UCSX-CPU-A9655

  • UCSX-CPU-A9555

  • UCSX-CPU-A9355

  • UCSX-CPU-A9135

  • UCSX-CPU-A95755

Note

 

For more information, see the Cisco UCS X-Series Compute Node Spec Sheet.

Not Applicable 5.3(0.250001)

GPU

UCSC-GPU-MI210

Not Applicable

5.3(0.250001)

DIMMs

DDR5-5600 MT/s:

  • UCSX-MR128G2RG3

DDR5-6400 MT/s:

  • UCS-MRX32G1RE5

  • UCS-MRX64G2RE5

Not Applicable

5.3(0.250001)

Storage Controller

UCSX-X10C-GPUFM

Not Applicable

5.3(0.240016)

Cisco UCS X410c M7 Compute Node

X-Series M7 Server

  • 6664 FI: 6.0(1.250198)

  • X-Direct FI - 4.3(4.240078)

  • 6400 Series and 6536 FI: 4.2(3e)

5.1(1.230052)

CPU

4th Generation Intel® Xeon® Scalable Processors

Note

 

For more information, see the Cisco UCS X410c M7 Compute Node Spec Sheet.

Not Applicable

5.1(1.230052)

DIMMs

UCSX-MRX16G1RE1

UCSX-MRX32G1RE1

UCSX-MRX64G2RE1

UCSX-MR128G4RE1

UCSX-MR256G8RE1

Not Applicable

5.1(1.230052)

UCSX-MRX96G2RF3

Not Applicable

5.2(2.240053)

Adapters

UCSX-ML-V5Q50G (Secure Boot)

UCSX-ME-V5Q50G (Secure Boot)

UCSX-ML-V5D200G

Not Applicable

5.1(1.230052)

UCSX-ML-V5D200GV2 (Secure Boot)

Not Applicable

5.2(0.230061)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

5.1(1.230052)

UCS-TPM-002D

Not Applicable

5.2(2.240053)

Graphics processing unit (GPU)

UCSX-GPU-A16

UCSX-GPU-A40

UCSX-GPU-A100-80

Not Applicable

5.1(1.230052)

UCSX-GPU-H100-80

UCSX-GPU-L40

UCSX-GPU-L4

UCSX-GPU-FLEX140

UCSX-GPU-FLEX170

Not Applicable

5.2(0.230127)

UCSX-GPU-L40S

Not Applicable

5.2(2.240053)

Storage Controller

UCSX-M2-HWRAID

UCSX-X10C-RAIDF

Not Applicable

5.1(1.230052)

UCSX-M2-PT-FPN

Not Applicable

5.2(0.230127)

UCSX-X10C-GPUFM

Not Applicable

5.2(0.230041)

Cisco UCS X210c M7 Compute Node

X-Series M7 Compute Node
  • 6664 FI: 6.0(1.250198)

  • X-Direct FI - 4.3(4.240078)

  • 6400 Series and 6536 FI: 4.2(3b)

5.1(0.230096)

CPU

4th Generation Intel® Xeon® Scalable Processors.

Not Applicable

5.1(0.230096)

5th Generation Intel® Xeon® Scalable Processors

Note

 

For more information, see the Cisco UCS X210c M7 Compute Node Spec Sheet.

Not Applicable

5.2(1.240010)

Additional 5th Generation Intel® Xeon® Scalable Processors:

  • UCSX-CPU-I4510T

  • UCSX-CPU-I4510

  • UCSX-CPU-I4509Y

  • UCSX-CPU-I3508U

Not Applicable

5.2(2.240053)

DIMMs

DDR5-4800MT/s:

  • UCSX-MRX16G1RE1

  • UCSX-MRX32G1RE1

  • UCSX-MRX64G2RE1

  • UCSX-MR128G4RE1

  • UCSX-MR256G8RE1

Not Applicable

5.2(1.240010)

DDR5-5600MT/s:

  • UCSX-MRX16G1RE3

  • UCSX-MRX32G1RE3

  • UCSX-MRX48G1RF3

  • UCSX-MRX64G2RE3

  • UCSX-MRX96G2RF3

  • UCSX-MR128G4RE3

  • UCSX-MR256G8RE3

Not Applicable

5.2(1.240010)

Adapters

UCSX-ML-V5Q50G (Secure Boot)

UCSX-ME-V5Q50G (Secure Boot)

UCSX-ML-V5D200G

Not Applicable

5.1(0.230096)

UCSX-ML-V5D200GV2 (Secure Boot)

Not Applicable

5.2(0.230061)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

5.1(0.230096)

UCS-TPM-002D

Not Applicable

5.2(2.240053)

Graphics Processing Unit (GPU)

UCSX-GPU-T4-MEZZ

UCSX-GPU-A16

UCSX-GPU-A40

Not Applicable

5.1(0.230096)

UCSX-GPU-A100-80

Not Applicable

5.1(0.230096)

UCSX-GPU-H100-80

UCSX-GPU-L40

UCSX-GPU-L4

UCSX-GPU-FLEX140

UCSX-GPU-FLEX170

Not Applicable

5.2(0.230127)

UCSX-GPU-L40S

Not Applicable

5.2(2.240053)

UCSX-GPU-H100-NVL

Not Applicable

5.3(0.240016)

UCSX-GPU-L4-Mezz

Not Applicable

UCSX-GPU-FLX140MZ

Not Applicable

5.2(2.240053)

Storage Controller

UCSX-X10C-PT4F

UCSX-X10C-RAIDF

UCSX-M2-HWRAID

Not Applicable

5.1(0.230096)

UCSX-M2-PT-FPN

Not Applicable

5.2(0.230041)

UCSX-X10C-GPUFM

Not Applicable

5.3(0.250021)

Cisco UCS X210c M6 Compute Node

X-Series M6 Server

  • X-Direct FI - 4.3(4.240078)

  • 6400 Series and 6536 FI: 4.2(1a)

5.0(1b)

Adapters

UCSX-V4-Q25GML

UCSX-V4-Q25GME

Not Applicable

5.0(1b)

UCSX-ML-V5Q50G (Secure Boot)

UCSX-ME-V5Q50G (Secure Boot)

Not Applicable

5.1(0.230054)

UCSX-ML-V5D200G

Not Applicable

5.0(2b)

UCSX-ML-V5D200GV2 (Secure Boot)

Not Applicable

5.2(0.230061)

Rear Mezzanine Adapters

UCSX-V4-PCIME

Not Applicable

5.0(2d)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

5.0(1b)

UCS-TPM-002D

Not Applicable

4.3(4.240152)

Graphics processing unit (GPU)

UCSX-GPU-A100-80

Not Applicable

5.0(2e)

UCSX-GPU-T4-MEZZ

UCSX-GPU-T4-16

UCSX-GPU-A16

UCSX-GPU-A40

Not Applicable

5.0(2d)

Storage Controller

UCSX-X10C-PT4F

UCSX-X10C-RAIDF

UCSX-M2-HWRAID

Not Applicable

5.0(4b)

UCSX-X10C-GPUFM

Not Applicable

5.2(0.230040)

Cisco UCS B200 M6 Server

B-Series M6 Server

6400 Series and 6536 FI: 4.1(3b)

4.2(1d)

Adapters

UCSB-ML-V5Q10G

Not Applicable

4.2(1d)

UCSB-MLOM-40G-04

UCSB-VIC-M84-4P

4.1(3b)

4.2(1d)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

4.2(1d)

UCS-TPM-002D

Not Applicable

4.3(4.240152)

Storage Controller

UCS-M2-HWRAID

UCSB-RAID12G-M6

UCSB-MSTOR-M6

UCSB-LSTOR-PT-M6

Not Applicable

4.2(1d)

Cisco UCS B200 M5 Server

Cisco UCS B480 M5 Server

B-Series M5 Server

6400 Series and 6536 FI: 4.1(3b)

4.1(3b)

Adapters

UCSB-MLOM-40G-03

UCSB-VIC-M83-8P

4.1(3b)

4.2(2e)

UCSB-MLOM-40G-04

UCSB-VIC-M84-4P

4.1(3b)

4.1(3b)

UCSB-MLOM-PT-01

4.1(3b)

Not Applicable

Trusted Platform Module (TPM)

UCSX-TPM2-001

UCSX-TPM2-002

Not Applicable

4.1(3b)

Storage Controller

UCS-M2-HWRAID

UCSB-MRAID12G

UCSB-MRAID12G-HE

UCSB-LSTOR-PT

Not Applicable

4.1(3c)

Cisco UCS C220 M8 Server

C-Series Intel M8 Server

  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.3(6.250048)

4.3(6.250039)

Cisco UCS C240 M8 Server

C-Series Intel M8 Server

  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.3(6.250048)

4.3(6.250039)

Storage Controller

UCSC-RAID-M1L16

  • 6400 Series, 6536, 6664, and X-Direct FI: 6.0(1.250198)

6.0(1.250127)

Cisco UCS C225 M8 Server

C-Series AMD M8 Server

  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.2(3b)

4.3(5.240021)

New Hardware Supported Since Initial Release

CPU

5th Generation AMD EPYC CPU:

  • UCS-CPU-A9655P

  • UCS-CPU-A9555P

  • UCS-CPU-A9355

  • UCS-CPU-A9135

  • UCS-CPU-A9575F

Note

 

For more information, see the Cisco UCS C225 M8 Server Spec Sheet.

Not Applicable

4.3(5.250001)

Storage Controller

UCSC-RAID-M1L16

UCSC-RAID-MP1L32

4.2(3b)

4.3(5.250001)

UCSC-HBA-M1L16

4.2(3b)

4.3(5.250001)

DIMMs

DDR5-5600 MT/s:

  • UCS-MR128G2RG3

DDR5-6400 MT/s

  • UCS-MRX32G1RE5

  • UCS-MRX64G2RE5

Not Applicable

4.3(5.250001)

Cisco UCS C245 M8 Server

C-Series AMD M8 Server
  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.2(3b)

4.3(4.241014)

New Hardware Supported Since Initial Release

Graphics processing unit (GPU)

UCSC-GPU-H100-NVL

Not Applicable

4.3(5.240021)

UCSC-GPU-MI210

Not Applicable

4.3(5.250001)

CPU

5th Generation AMD EPYC CPU:

  • UCS-CPU-A9655

  • UCS-CPU-A9555

  • UCS-CPU-A9355

  • UCS-CPU-A9135

  • UCS-CPU-A9575F

Note

 

For more information, see the Cisco UCS C245 M8 Spec Sheet.

Not Applicable

4.3(5.250001)

Storage Controller

UCSC-RAID-M1L16

UCSC-RAID-MP1L32

4.2(3b)

4.3(5.250001)

UCSC-HBA-M1L16

4.2(3b)

4.3(5.250001)

DIMMs

DDR5-5600 MT/s:

  • UCS-MR128G2RG

DDR5-6400 MT/s:

  • UCS-MRX32G1RE5

  • UCS-MRX64G2RE5

  • UCS-MRX96G2RF5

Not Applicable

4.3(5.250001)

Cisco UCS C220 M7 Server

C-Series M7 Server

  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.2(3b)

4.3(1.230097)

CPU

4th Generation Intel® Xeon® Scalable Processors.

Not Applicable

4.3(1.230097)

5th Generation Intel® Xeon® Scalable Processors

Note

 

For more information, see the Cisco UCSC C220 M7 SFF Rack Server Spec Sheet.

Not Applicable

4.3(3.240022)

Additional 5th Generation Intel® Xeon® Scalable Processors:

  • UCS-CPU-I4510T

  • UCS-CPU-I4510

  • UCS-CPU-I4509Y

  • UCS-CPU-I3508U

Not Applicable

4.3(4.240152)

DIMMs

DDR5-4800MT/s:

  • UCS-MRX16G1RE1

  • UCS-MRX32G1RE1

  • UCS-MRX64G2RE1

  • UCS-MR128G4RE1

Not Applicable

4.3(3.240022)

DDR5-5600MT/s:

  • UCS-MRX16G1RE3

  • UCS-MRX32G1RE3

  • UCS-MRX48G1RF3

  • UCS-MRX64G2RE3

  • UCS-MRX96G2RF3

  • UCS-MR128G4RE3

Note

 

48GB and 96GB memory DIMMs are not supported on UCS-CPU-I3508U, UCS-CPU-I4509Y, UCS-CPU-I4510, UCS-CPU-I4510T

Not Applicable

4.3(3.240022)

Adapters

UCSC-M-V5Q50G

UCSC-M-V5D200G

Not Applicable

4.3(1.230097)

UCSC-P-V5D200G (Secure Boot)

UCSC-P-V5Q50G (Secure Boot)

4.3(2.230117)

4.3(2.230184)

UCSC-M-V5D200GV2 (Secure Boot)

UCSC-M-V5Q50GV2 (Secure Boot)

Not Applicable

4.3(2.230258)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

4.3(1.230097)

UCS-TPM-002D

Not Applicable

4.3(4.240152)

Graphics processing unit (GPU)

UCSC-GPU-A16

UCSC-GPU-A100-80

Not Applicable

4.3(1.230097)

UCSC-GPU-L4

UCSC-GPU-FLEX140

Not Applicable

4.3(2.230207)

Storage Controller

UCS-M2-NVRAID

4.3(2.230117)

4.3(2.230207)

UCSC-RAID-M1L16

4.3(2.230117)

4.3(4.242038)

UCSC-HBA-M1L16

4.3(2.230117)

4.3(4.242038)

Virtual Drives

UCS-SD16TKA3X-EP

UCS-SD32TKA3X-EP

UCS-SD16TBKANK9

UCS-SD19TKA1X-EV

UCS-SD38TKA1X-EV

UCS-SD76TKA1X-EV

UCS-SD15TKA1X-EV

UCS-SD38TBKANK9

UCS-SD76TBKANK9

4.3(2.230117)

4.3(2.230207)

Cisco UCS C240 M7 Server

C-Series M7 Server

  • 6664 and X-Direct FI: 6.0(1.250198)

  • 6400 Series and 6536 FI: 4.2(3b)

4.3(1.230097)

CPU

4th Generation Intel® Xeon® Scalable Processors.

Not Applicable

4.3(1.230097)

5th Generation Intel® Xeon® Scalable Processors

Note

 

For more information, see the Cisco UCS C240 M7 SFF Rack Server Spec Sheet.

Not Applicable

4.3(3.240022)

Additional 5th Generation Intel® Xeon® Scalable Processors:

  • UCS-CPU-I4510T

  • UCS-CPU-I4510

  • UCS-CPU-I4509Y

  • UCS-CPU-I3508U

Not Applicable

4.3(4.240152)

DIMMs

DDR5-4800MT/s:

  • UCS-MRX16G1RE1

  • UCS-MRX32G1RE1

  • UCS-MRX64G2RE1

  • UCS-MR128G4RE1

  • UCS-MR256G8RE1

Not Applicable

4.3(3.240022)

DDR5-5600MT/s:

  • UCS-MRX16G1RE3

  • UCS-MRX32G1RE3

  • UCS-MRX48G1RF3

  • UCS-MRX64G2RE3

  • UCS-MRX96G2RF3

  • UCS-MR128G4RE3

  • UCS-MR256G8RE3

Not Applicable

4.3(3.240022)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

4.3(1.230097)

UCS-TPM-002D

Not Applicable

4.3(4.240152)

Adapters

UCSC-M-V5Q50G

UCSC-M-V5D200G

Not Applicable

4.3(1.230097)

UCSC-P-V5D200G (Secure Boot)

UCSC-P-V5Q50G (Secure Boot)

4.3(2.230117)

4.3(2.230184)

UCSC-M-V5D200GV2 (Secure Boot)

UCSC-M-V5Q50GV2 (Secure Boot)

Not Applicable

4.3(2.230258)

Graphics processing unit (GPU)

UCSC-GPU-A16

UCSC-GPU-A100-80

Not Applicable

4.3(1.230097)

UCSC-GPU-H100-80

UCSC-GPU-L40

UCSC-GPU-L4

UCSC-GPU-FLEX140

UCSC-GPU-FLEX170

Not Applicable

4.3(2.230207)

UCSC-GPU-L40S

Not Applicable

4.3(4.240152)

UCSC-GPU-H100-NVL

Not Applicable

4.3(5.240021)

Storage Controller

UCS-M2-NVRAID

4.3(2.230117)

4.3(2.230207)

UCSC-RAID-M1L32

4.3(2.230117)

4.3(4.242038)

UCSC-HBA-M1L16

4.3(2.230117)

4.3(4.242038)

Virtual Drives

UCS-SD16TKA3X-EP

UCS-SD32TKA3X-EP

UCS-SD16TBKANK9

UCS-SD19TKA1X-EV

UCS-SD38TKA1X-EV

UCS-SD76TKA1X-EV

UCS-SD15TKA1X-EV

UCS-SD38TBKANK9

UCS-SD76TBKANK9

4.3(2.230117)

4.3(2.230207)

Cisco UCS C220 M6 Server

Cisco UCS C240 M6 Server

C-Series M6 Server

6400 Series and 6536 FI: 4.1(3b)

4.2(1e)

Adapters

UCSC-PCIE-C25Q-04

UCSC-PCIE-C100-04

4.1(3b)

4.2(1e)

UCSC-M-V100-04

UCSC-M-V25-04

4.1(3b)

4.2(1e)

UCSC-M-V5D200G

Not Applicable

4.2(2f)

UCSC-M-V5Q50G

Not Applicable

4.2(2b)

UCSC-P-V5D200G (Secure Boot)

UCSC-P-V5Q50G (Secure Boot)

4.3(2.230117)

4.3(2.230184)

UCSC-M-V5D200GV2 (Secure Boot)

UCSC-M-V5Q50GV2 (Secure Boot)

Not Applicable

4.3(2.230258)

Trusted Platform Module (TPM)

UCSX-TPM-002C

Not Applicable

4.2(1e)

UCS-TPM-002D

Not Applicable

4.3(4.240152)

Graphics processing unit (GPU)

UCSC-GPU-A16

UCSC-GPU-A100-80

Not Applicable

4.2(3b)

UCSC-GPU-L4

Not Applicable

4.3(4.240152)

Storage Controller

UCS-M2-HWRAID

UCSC-RAID-M6T

UCSC-RAID-M6SD

UCSC-RAID-M6HD

UCSC-SAS-M6HD

UCSC-SAS-M6T

Not Applicable

4.2(1e)

Cisco UCS C245 M6 Server

Cisco UCS C225 M6 Server

C-Series M6 Server

6400 Series and 6536 FI: 4.1(3b)

4.2(1e)

Adapters

UCSC-PCIE-C25Q-04

UCSC-PCIE-C100-04

4.1(3b)

4.2(1e)

UCSC-M-V100-04

UCSC-M-V25-04

4.1(3b)

4.2(1e)

UCSC-M-V5D200G

Not Applicable

4.2(2f)

UCSC-M-V5Q50G

Not Applicable

4.2(2b)

UCSC-P-V5D200G (Secure Boot)

UCSC-P-V5Q50G (Secure Boot)

4.3(2.230117)

4.3(2.230184)

UCSC-M-V5D200GV2 (Secure Boot)

UCSC-M-V5Q50GV2 (Secure Boot)

Not Applicable

4.3(2.230258)

Trusted Platform Module (TPM)

UCSX-TPM2-002B-C

Not Applicable

4.2(1e)

UCS-TPM2-002D

Not Applicable

4.3(4.240152)

Graphics processing unit (GPU)

UCSC-GPU-A16

UCSC-GPU-A100-80

Not Applicable

4.2(3b)

Storage Controller

UCS-M2-HWRAID

UCSC-RAID-M6T

UCSC-RAID-M6SD

UCSC-RAID-M6HD

UCSC-SAS-M6HD

UCSC-SAS-M6T

Not Applicable

4.2(1e)

Cisco UCS C220 M5 Server

Cisco UCS C240 M5 Server

Cisco UCS C480 M5 Server

C-Series M5 Server

6400 Series and 6536 FI: 4.1(3b)

4.1(3b)

Adapters

UCSC-MLOM-C40Q-03

UCSC-PCIE-C40Q-03

4.1(3b)

4.2(2g)

UCSC-PCIE-C25Q-04

UCSC-MLOM-C25Q-04

UCSC-PCIE-C100-04

UCSC-MLOM- C100-04

4.1(3b)

4.1(3b)

Trusted Platform Module (TPM)

UCSX-TPM2-001

UCSX-TPM2-002

Not Applicable

4.1(3b)

Graphics processing unit (GPU)

UCSC-GPU-A100-80

Not Applicable

4.2(3b)

Storage Controller

UCS-M2-HWRAID

UCSC-RAID-M5HD

UCSC-RAID-M5

UCSC-SAS-M5,

UCSC-SAS-M5HD

UCSC-SAS12GHBA

UCSC-9400-8E

Not Applicable

4.1(3b)


Note


Change in Firmware Version Schema :

  • X-Series M6 Server Firmware Bundle: Post server firmware release 5.0(4g), the version number is in a number format instead of a letter format.

  • C-Series M5 and M6 Server Firmware Bundle: Post server firmware release 4.2(3m), the version number is in a number format instead of a letter format.

  • B-Series M5 and M6 Server Firmware Bundle: Post server firmware release 4.2(3j), the version number is in the 5.x series and in a number format instead of a letter format.

  • Infrastructure Firmware Bundle: With infra firmware release 4.3(2) and later, the version number is in a number format instead of a letter format.

For example: 4.3(2.230117) , where 23 represents year, 0117 shows the incremental build number.​


For more information on Cisco Intersight Infrastructure Firmware release notes, Server Firmware release notes, and Release Bundle Content document see Release Notes.

Table 4. Supported Combination of Hardware Components in IMM

Component

Supported Combination

Cisco UCS X-Series Direct

  • Integrated FI: UCSX-S9108-100G

  • Cisco UCS X-Series Direct supports all components that are compatible with Cisco UCS X-Series modular system.

  • Starting with Infrastructure firmware release 6.0(1.250198):

    • Secondary chassis is supported.

    • Rack servers are supported.

  • UCS X-Series Direct currently does not support Fabric Extender.

Topologies

Direct-Attached Racks through 10G/25G/100G connections

Break-out port configuration through 10G/25G connections

FEX-Attached Racks through 10GE connections

Chassis through 10G/25G/100G connections

N9K-C93108YC-FX3 FEX through 10G/25G connections

Fabric Interconnects

  • UCS-FI-6536 and direct-attached rack server are supported at 40G and 100G on Cisco UCS 1400 and 15000 series VIC adapters.

  • Cisco UCS 6664 FI is supported with the UCSX-9508 chassis using UCSX-I-9108-25G and UCSX-I-9108-100G IFMs.

Input/Output Module (IOM)

  • UCS-IOM-2204XP and UCS-IOM-2208XP are not supported on Cisco UCS 6500 Series Fabric Interconnects.

  • UCS-IOM-2304 and UCS-IOM-2304V2 are supported only with Cisco UCS 6500 series Fabric Interconnect.

  • When there is a mixed IOM configuration, Access Policy deployment can fail resulting in Server Profile deployment failure. It will recover once both the IOMs are replaced.

X-Fabric Modules (XFM)

UCS 9416 X-Fabric module is supported only on UCSX-9508 chassis and required for Peripheral Component Interconnect Express (PCIe) node and GPU discovery or inventory support in IMM.

Fabric Extender (FEX)

Cisco Nexus 2232PP is not supported on Cisco UCS 6500 Series Fabric Interconnects.

Rear Mezzanine Adapters

  • UCS PCI mezz card for X‐Fabric connectivity.

  • The UCSX-210C Compute Node must include a UCSX-V4-PCIME or a supported mezz card when paired with a X440p PCIe node.

Adapters

  • UCSX-X10C-GPUFM is an adapter that supports the GPU, UCSX-GPU-T4-MEZZ. For more information, see Cisco UCS X10c Front Mezzanine GPU Module Installation and Service Guide.

  • UCSX-V4-Q25GME is a mezz card requires UCS VIC 14000 bridge connector (UCSX-V4-BRIDGE) and UCSX-V4-Q25GML mLOM support in the X210c Compute Node. For more information, see Cisco UCS X210c M6 Compute Node.

  • The UCSX-210C Compute Node must include a UCSX-V4-PCIME or a supported mezz card when paired with a X440p PCIe node.

  • UCSX-ML-V5D200G adapter is supported on Cisco UCS 6500 series Fabric Interconnect at 40G and 100G speed, as well as on Cisco UCS 6400 series Fabric Interconnect at 25G speed.

  • Cisco UCS C-Series and X-Series M7 servers support only Cisco UCS 15000 series VIC adapters.

  • UCSX-ME-V5Q50G is a mezz card that requires UCS VIC 15000 bridge connector (UCSX-V5-BRIDGE) and UCSX-ML-V5Q50G mLOM support in the X210c Compute Node. However, this mezz adapter is not supported with UCSX-ML-V5D200G mLOM.

    • On a B-series server, installing a combination of Cisco UCS 1400 and UCS 15000 series VIC adapters is not supported.

    • Cisco UCS VIC 1300 Series adapters are supported on B-Series and C-Series M5 servers with the following combination.

      • UCS-FI-6454 and UCS-IOM-2408

      • UCS-FI-6536 and UCS-IOM-2408

      • UCS-FI-6454 and UCS-IOM-2204XP

      • UCS-FI-6454 and UCS-IOM-2208XP

      • UCS-FI-6536 and direct-attached rack server at 40G

      • UCS-FI-6454 and rack server connected through FEX

      • UCS-FI-6454 and direct-attached rack server with 10G QSA

      • UCS-FI-6536 and UCS-IOM-2304 or UCS-IOM-2304V2

      • UCS-FI-64108 and UCS-IOM-2408

      • UCS-FI-64108 and UCS-IOM-2204XP

      • UCS-FI-64108 and UCS-IOM-2208XP

      • UCS-FI-64108 and direct-attached rack server

      • UCS-FI-64108 and rack server connected through FEX

    • UCSC-M-V100-04, UCSC-PCIE-C100-04, UCSC-MLOM-C100-04 are supported only on Cisco UCS 6500 Series Fabric Interconnects.

  • The following combinations are not supported on UCS C series M6 servers:

    • 1400 Series MLOM adapters with 15000 Series PCIE adapters

    • UCSC-M-V5Q50GV2 and UCSC-M-V5D200GV2 are not supported with 14xx PCIE adapters

  • Ensure that you have upgraded servers to the VIC supported release versions before installing the VIC adapters into the server. If you install VIC adapters on servers running an earlier release and later decide to upgrade the servers to the supported version, you need to perform A/C power cycle for the servers to enable the adapters.

Graphics processing unit (GPU)